884 resultados para Colour Removal


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Paradise whiptail (Pentapodus paradiseus) has distinct reflective stripes on its head and body. The reflective stripes contain a dense layer of physiologically active iridophores, which act as multilayer reflectors. The wavelengths reflected by these stripes can change from blue to red in 0.25 s. Transmission electron microscopy revealed that the iridophore cells contain plates that are, on average, 51.4 nm thick. This thickness produces a stack, which acts as an ideal quarter-wavelength multilayer reflector (equal optical thickness of plates and spaces) in the blue, but not the red, region of the spectrum. When skin preparations were placed into hyposmotic physiological saline, the peak wavelength of the reflected light shifted towards the longer (red) end of the visible spectrum. Hyperosmotic saline reversed this effect and shifted the peak wavelength towards shorter (blue/UV) wavelengths. Norepinephrine (100 mumol l(-1)) shifted the peak wavelength towards the longer end of the spectrum, while adenosine (100 mumol l(-1)) reversed the effects of norepinephrine. The results from this study show that the wavelength changes are elicited by a change of similar to70 nm in the distance between adjacent plates in the iridophore cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to meet increasingly stringent European discharge standards, new applications and control strategies for the sustainable removal of ammonia from wastewater have to beimplemented. In this paper we discuss anitrogen removal system based on the processesof partial nitrification and anoxic ammoniaoxidation (anammox). The anammox process offers great opportunities to remove ammonia in fully autotrophic systems with biomass retention. No organic carbon is needed in such nitrogenremoval system, since ammonia is used a selectron donor for nitrite reduction. The nitrite can be produced from ammonia in oxygen-limited biofilm systems or in continuous processes without biomass retention. For successful implementation of the combined processes, accurate biosensors for measuring ammonia and nitrite concentrations, insight inthe complex microbial communities involved, and new control strategies have to be developed and evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complete biological nutrient removal (BNR) in a single tank, sequencing batch reactor (SBR) process, is demonstrated here at full-scale on a typical domestic wastewater. The unique feature of the UniFed process is the introduction of the influent into the settled sludge blanket during the settling and decant periods of the SBR operation. This achieves suitable conditions for denitrification and anaerobic phosphate release which is critical to successful biological phosphorus removal, It also achieves a selector effect, which helps in generating a compact, well settling biomass in the reactor. The results of this demonstration show that it is possible to achieve well over 90% removal of GOD, nitrogen and phosphorus in such a process. Effluent quality achieved over a six-month operating period directly after commissioning was: 29 mg/l GOD, 0.5 mg/l NH4-N, 1.5 mg/l NOx-N and 1.5 mg/l PO4-P (50%-iles of daily samples). During an 8-day, intensive sampling period, the effluent BOD5 was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simultaneous nitrification and denitrification (SND) via the nitrite pathway and anaerobic-anoxic-enhanced biological phosphorus removal (EBPR) are two processes that can significantly reduce the energy and COD demand for nitrogen and phosphorus removal. The combination of these two processes has the potential of achieving simultaneous nitrogen and phosphorus removal with a minimal requirement for COD. A lab-scale sequencing batch reactor (SBR) was operated in alternating anaerobic-aerobic mode with a low dissolved oxygen (DO) concentration (0.5 mg/L) during the aerobic period, and was demonstrated to accomplish nitrification, denitrification, and phosphorus removal. Under anaerobic conditions, COD was taken up and converted to poly-hydroxyalkanoates (PHAs), accompanied by phosphorus release. In the subsequent aerobic stage, PHA was oxidized and phosphorus was taken up to

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two varieties of adzuki beans (Vigna angularis), Bloodwood and Erimo, were stored at temperatures of 10, 20 or 30degreesC, and relative humidities (RH) 40 or 65%, and samples were analysed at 0, 1.5, 3 and 6 months. Storage at 30degreesC for > 1.5 months caused a significant decrease in the a(star) and b(star) colour values and darkening of the seed coat. Beans stored at 65% RH had lower L-star but higher a(star) and b(star) colour values than those stored at 40% RH. Bloodwood and Erimo samples showed similar trends in colour during storage. The best storage conditions for the preservation of the adzuki colour were 10degreesC and 65% RH. The Australian beans had lower L-star, a(star) and b(star) colour values than Japanese Erimo-shouzu beans and storage increased the difference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two terminal optically addressed image processing device based on two stacked sensing/switching p-i-n a-SiC:H diodes is presented. The charge packets are injected optically into the p-i-n sensing photodiode and confined at the illuminated regions changing locally the electrical field profile across the p-i-n switching diode. A red scanner is used for charge readout. The various design parameters and addressing architecture trade-offs are discussed. The influence on the transfer functions of an a-SiC:H sensing absorber optimized for red transmittance and blue collection or of a floating anode in between is analysed. Results show that the thin a-SiC:H sensing absorber confines the readout to the switching diode and filters the light allowing full colour detection at two appropriated voltages. When the floating anode is used the spectral response broadens, allowing B&W image recognition with improved light-to-dark sensitivity. A physical model supports the image and colour recognition process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large area colour imager optically addressed is presented. The colour imager consists of a thin wide band gap p-i-n a-SiC:H filtering element deposited on the top of a thick large area a-SiC:H(-p)/a-Si:H(-i)/a-SiC:H(-n) image sensor, which reveals itself an intrinsic colour filter. In order to tune the external applied voltage for full colour discrimination the photocurrent generated by a modulated red light is measured under different optical and electrical bias. Results reveal that the integrated device behaves itself as an imager and a filter giving information not only on the position where the optical image is absorbed but also on it wavelength and intensity. The amplitude and sign of the image signals are electrically tuneable. In a wide range of incident fluxes and under reverse bias, the red and blue image signals are opposite in sign and the green signal is suppressed allowing blue and red colour recognition. The green information is obtained under forward bias, where the blue signal goes down to zero and the red and green remain constant. Combining the information obtained at this two applied voltages a RGB colour image picture can be acquired without the need of the usual colour filters or pixel architecture. A numerical simulation supports the colour filter analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a double colour laser scanned photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the colour detection process are analysed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a Double Color Laser Scanned Photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the color detection process are analyzed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZnO:Al/p (SiC:H)/i (Si:H)/n (SiC:H) large area image and colour sensor are analysed. Carrier transport and collection efficiency are investigated from dark and illuminated current-voltage (I-V) dependence and spectral response measurements under different optical and electrical bias conditions. Results show that the carrier collection depends on the optical bias and on the applied voltage. By changing the electrical bias around the open circuit voltage it is possible to filter the absorption at a given wavelength and so to tune the spectral sensitivity of the device. Transport and optical modelling give insight into the internal physical process and explain the bias control of the spectral response and the image and colour sensing properties of the devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanofiltration process for the treatment/valorisation of cork processing wastewaters was studied. A DS-5 DK 20/40 (GE Water Technologies) nanofiltration membrane/module was used, having 2.09 m(2) of surface area. Hydraulic permeability was determined with pure water and the result was 5.2 L.h(-1).m(-2).bar(-1). The membrane presents a rejection of 51% and 99% for NaCl and MgSO4 salts, respectively. Two different types of regimes were used in the wastewaters filtration process, total recycling mode and concentration mode. The first filtration regime showed that the most favourable working transmembrane pressure was 7 bar working at 25 degrees C. For the concentration mode experiments it was observed a 30% decline of the permeate fluxes when a volumetric concentration factor of 5 was reached. The permeate COD, BOD5, colour and TOC rejection values remained well above the 90% value, which allows, therefore, the concentration of organic matter (namely the tannin fraction) in the concentrate stream that can be further used by other industries. The permeate characterization showed that it cannot be directly discharged to the environment as it does not fulfil the values of the Portuguese discharge legislation. However, the permeate stream can be recycled to the process (boiling tanks) as it presents no colour and low TOC (< 60 ppm) or if wastewater discharge is envisaged we have observed that the permeate biodegradability is higher than 0.5, which renders conventional wastewater treatments feasible.