This paper presents simulation and experimental studies on the characterization of ultra wideband antennas for imaging applications. Various configurations of antennas were simulated for their time and frequency domain characteristics with special emphasis on flat responses for group delay and gain versus frequency. Parametric studies reported here showed that locating the capacitive feed strip near the vertex of the triangle gave better response in these respects. An antenna with operating frequency from 2.9GHz to 4.1GHz was fabricated and measured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Facet-based sentiment analysis involves discovering the latent facets, sentiments and their associations. Traditional facet-based sentiment analysis algorithms typically perform the various tasks in sequence, and fail to take advantage of the mutual reinforcement of the tasks. Additionally,inferring sentiment levels typically requires domain knowledge or human intervention. In this paper, we propose aseries of probabilistic models that jointly discover latent facets and sentiment topics, and also order the sentiment topics with respect to a multi-point scale, in a language and domain independent manner. This is achieved by simultaneously capturing both short-range syntactic structure and long range semantic dependencies between the sentiment and facet words. The models further incorporate coherence in reviews, where reviewers dwell on one facet or sentiment level before moving on, for more accurate facet and sentiment discovery. For reviews which are supplemented with ratings, our models automatically order the latent sentiment topics, without requiring seed-words or domain-knowledge. To the best of our knowledge, our work is the first attempt to combine the notions of syntactic and semantic dependencies in the domain of review mining. Further, the concept of facet and sentiment coherence has not been explored earlier either. Extensive experimental results on real world review data show that the proposed models outperform various state of the art baselines for facet-based sentiment analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mathematical model for diffuse fluorescence spectroscopy/imaging is represented by coupled partial differential equations (PDEs), which describe the excitation and emission light propagation in soft biological tissues. The generic closed-form solutions for these coupled PDEs are derived in this work for the case of regular geometries using the Green's function approach using both zero and extrapolated boundary conditions. The specific solutions along with the typical data types, such as integrated intensity and the mean time of flight, for various regular geometries were also derived for both time-and frequency-domain cases. (C) 2013 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical microscopy is a versatile and robust tool used for the diagnosis of a plethora of diseases. However, due to various reasons, it remains inaccessible in resource limited settings. In this paper, we present an automated and cost-effective alternative to microscopy for use in clinical diagnostics. With the use of custom optics and microfluidics, we demonstrate a field-portable imaging flow cytometry system. Using the presented system, we have been able to image 586 cells per second. We demonstrate the clinical relevance of the proposed system by differentiating between suspensions of healthy and sphered RBCs based on high-throughput morphometric analysis. The instrument presented here is a major advancement in the domain of field portable diagnostics as it enables fast and robust quantitative diagnostic testing at the point-of-care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cells in the lateral intraparietal cortex (LIP) of rhesus macaques respond vigorously and in spatially-tuned fashion to briefly memorized visual stimuli. Responses to stimulus presentation, memory maintenance, and task completion are seen, in varying combination from neuron to neuron. To help elucidate this functional segmentation a new system for simultaneous recording from multiple neighboring neurons was developed. The two parts of this dissertation discuss the technical achievements and scientific discoveries, respectively.

Technology. Simultanous recordings from multiple neighboring neurons were made with four-wire bundle electrodes, or tetrodes, which were adapted to the awake behaving primate preparation. Signals from these electrodes were partitionable into a background process with a 1/f-like spectrum and foreground spiking activity spanning 300-6000 Hz. Continuous voltage recordings were sorted into spike trains using a state-of-the-art clustering algorithm, producing a mean of 3 cells per site. The algorithm classified 96% of spikes correctly when tetrode recordings were confirmed with simultaneous intracellular signals. Recording locations were verified with a new technique that creates electrolytic lesions visible in magnetic resonance imaging, eliminating the need for histological processing. In anticipation of future multi-tetrode work, the chronic chamber microdrive, a device for long-term tetrode delivery, was developed.

Science. Simultaneously recorded neighboring LIP neurons were found to have similar preferred targets in the memory saccade paradigm, but dissimilar peristimulus time histograms, PSTH). A majority of neighboring cell pairs had a difference in preferred directions of under 45° while the trial time of maximal response showed a broader distribution, suggesting homogeneity of tuning with het erogeneity of function. A continuum of response characteristics was present, rather than a set of specific response types; however, a mapping experiment suggests this may be because a given cell's PSTH changes shape as well as amplitude through the response field. Spike train autocovariance was tuned over target and changed through trial epoch, suggesting different mechanisms during memory versus background periods. Mean frequency-domain spike-to-spike coherence was concentrated below 50 Hz with a significant maximum of 0.08; mean time-domain coherence had a narrow peak in the range ±10 ms with a significant maximum of 0.03. Time-domain coherence was found to be untuned for short lags (10 ms), but significantly tuned at larger lags (50 ms).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heterodimerization of integrin Mac-1 (alpha(M) beta(2)) Subunits plays important role on regulating leukocytes adhesion to extracellular matrix or endothelial cells. Here, using total internal reflection microscopy, we investigated the heterodimerization of integrin Mac-1 subunits at the single-molecule level in live cells. Individual alpha(M) subunit fused to the enhanced yellow fluorescent protein (eYFP) was imaged at the basal plasma membrane of live Chinese hamster ovary (CHO) cells. Through analysis of mean square displacement (MSD), diffusion coefficient, the size of restricted domain and fraction of molecules undergoing restricted diffusion, we found that as compared with the diffusion in the absence of beta(2) subunit, the diffusion of single-molecule of alpha(M)-YFP was suppressed significantly in the presence of beta(2) subunit. Thus, based on the oligomerization-induced trapping model, we suggested that in the presence of beta(2) subunit, the am subunit may form heterodimer with it. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray phase imaging with illumination by a partially coherent source with a setup similar to in-line holography is considered. Using the optical transform function, we consider the effects of partial coherence on this x-ray phase imaging for a weak phase object. The optimal contrast and the resolution of phase imaging are analyzed. As the coherence decreases, the imaging contrast and the optimal contrast frequency decrease, and the resolution degrades. It is shown that this contrast-enhanced phase-imaging method can be regarded as a linear bandpass filter and that the bandwidth and the image contrast are changeable. The frequency property of the imaging system can be improved if an incoherent x-ray source with the proper shape is used. (C) 1999 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The resolution and classical noise in ghost imaging with a classical thermal light are investigated theoretically. For ghost imaging with a Gaussian Schell model source, the dependences of the resolution and noise on the spatial coherence of the source and the aperture in the imaging system are discussed and demonstrated by using numerical simulations. The results show that an incoherent source and a large aperture will lead to a good image quality and small noise.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A grating-lens combination unit is developed to form a scaling self-transform function that can self-image on scale. Then an array of many such grating-lens units is used for the optical interconnection of a two-dimensional neural network, and experiments are carried out. We find that our idea is feasible, the optical interconnection system is simple, and optical adjustment is easy. (C) 1998 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ambiguity function was employed as a merit function to design an optical system with a high depth of focus. The ambiguity function with the desired enlarged-depth-of-focus characteristics was obtained by using a properly designed joint filter to modify the ambiguity function of the original pupil in the phase-space domain. From the viewpoint of the filter theory, we roughly propose that the constraints of the spatial filters that are used to enlarge the focal depth must be satisfied. These constraints coincide with those that appeared in the previous literature on this topic. Following our design procedure, several sets of apodizers were synthesized, and their performances in the defocused imagery were compared with each other and with other previous designs. (c) 2005 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We quantitatively study the domain inversion in a RuO2:LiNbO3 crystal wafer by the digital holographic interferometry. The crystal wafer is placed into one arm of a Mach-Zehnder-type interferometer to record a series of holograms. Making use of the angular spectrum backward propagation algorithm, we reconstruct the optical wave field in the crystal plane. The extracted phase difference from the reconstructed optical wave field is a well linear function of the applied external voltage. We deduce that the linear electro-optic coefficient of the detected RuO2:LiNbO3 crystal sample is 9.1x10(-12) m/V. An unexpected phase contrast at the antiparallel domain wall is observed and the influence of the applied external voltage on it is studied in detail. Also the built-in internal field is quantitatively measured as 0.72 kV/mm. (c) 2006 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

提出一种基于正弦相位调制的频域光学相干层析成像,利用正弦相位调制干涉术探测复频域干涉条纹的实部和虚部,重建复频域干涉条纹。对该复频域干涉条纹作逆傅里叶变换后,消除了频域光学相干层析成像中存在的复共轭镜像以及直流背景和自相干噪声。对玻璃片样品进行了层析成像实验。实验结果表明,采用正弦相位调制的频域光学相干层析成像,将可利用的成像深度范围扩大到原来的2倍,实现了全深度探测的频域光学相干层析成像。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As distinct from coated photonic crystals, in this paper we propose a novel one that is made of dielectric tubes arranged in a close-packet square lattice. Without metallic cores, this structure is low-loss and convenient to fabricate. A left-handed frequency region is found in the second band by dispersion characteristic analysis. Without inactive modes for the transverse electric mode, negative refraction and subwavelength imaging are demonstrated by the finite-difference time-domain simulations with two symmetrical interfaces, i.e. Gamma X and Gamma M.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

IMPORTANCE: Forward models predict the sensory consequences of planned actions and permit discrimination of self- and non-self-elicited sensation; their impairment in schizophrenia is implied by an abnormality in behavioral force-matching and the flawed agency judgments characteristic of positive symptoms, including auditory hallucinations and delusions of control. OBJECTIVE: To assess attenuation of sensory processing by self-action in individuals with schizophrenia and its relation to current symptom severity. DESIGN, SETTING, AND PARTICIPANTS: Functional magnetic resonance imaging data were acquired while medicated individuals with schizophrenia (n = 19) and matched controls (n = 19) performed a factorially designed sensorimotor task in which the occurrence and relative timing of action and sensation were manipulated. The study took place at the neuroimaging research unit at the Institute of Cognitive Neuroscience, University College London, and the Maudsley Hospital. RESULTS: In controls, a region of secondary somatosensory cortex exhibited attenuated activation when sensation and action were synchronous compared with when the former occurred after an unexpected delay or alone. By contrast, reduced attenuation was observed in the schizophrenia group, suggesting that these individuals were unable to predict the sensory consequences of their own actions. Furthermore, failure to attenuate secondary somatosensory cortex processing was predicted by current hallucinatory severity. CONCLUSIONS AND RELEVANCE: Although comparably reduced attenuation has been reported in the verbal domain, this work implies that a more general physiologic deficit underlies positive symptoms of schizophrenia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new concept of frequency coherence in the frequency-time domain to describe the field correlations between two lightwaves with different frequencies. The coherence properties of the modulated beams from lightwave sources with different spectral widths and the modes of Fabry-Wrot (FP) laser are investigated. It is shown that the lightwave and its corresponding sidebands produced by the optical intensity modulation are perfectly coherent. The measured linewidth of the beat signal is narrow and almost identical no matter how wide the spectral width of the beam is. The frequency spacing of the adjacent FP modes is beyond the operation frequency range of the measurement instruments. In our experiment, optical heterodyne technique is used to investigate the frequency coherence of the modes of FP laser by means of the frequency shift induced by the optical intensity modulation. Experiments show that the FP modes are partially coherent and the mode spacing is relatively fixed even when the wavelength changes with ambient temperature, bias current and other factors. Therefore, it is possible to generate stable and narrow-linewidth signals at frequencies corresponding to several mode intervals of the laser.