940 resultados para Carpal Bones


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To identify the occurrence, types, and severity of associated injuries outside the facial region among patients diagnosed with facial fractures, and to analyze whether there are any factors related to associated injuries. MATERIALS AND METHODS: This was a cross-sectional study of 401 patients diagnosed with facial fractures during the 2-year period from 2003 to 2004. RESULTS: Associated injuries were observed in 101 patients (25.2%). The most common type of injury was a limb injury (13.5%), followed by brain (11.0%), chest (5.5%), spine (2.7%), and abdominal (0.8%) injuries. Multiple associated injuries were observed in 10% and polytrauma in 7.5%. The mortality rate was 0.2%. The occurrence of associated injury correlated significantly with trauma mechanism and fracture type; high-speed accidents and severe facial fractures were significant predictors of associated injury. CONCLUSIONS: Associated injuries are frequent among patients who have sustained facial fractures. The results underscore the importance of multiprofessional collaboration in diagnosis and sequencing of treatment, but also the importance of arranging appropriate clinical rotations for maxillofacial residents in training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To compare changes in the largest cross-sectional area (CSA) of the median nerve in wrists undergoing surgical decompression with changes in wrists undergoing non-surgical treatment of carpal tunnel syndrome (CTS). Methods This study was a prospective cohort study in 55 consecutive patients with 78 wrists with established CTS, including 60 wrists treated with surgical decompression and 18 wrists with non-surgical treatment. A sonographic examination was scheduled before and 4 months after initiation of treatment. We compared changes in CSA of the median nerve between wrists with surgical treatment and wrists with non-surgical treatment using linear regression models. Results Decreases in CSA of the median nerve were more pronounced in wrists with CTS release than in wrists undergoing nonsurgical treatment (difference in means, 1.0 mm2; 95% confidence interval, 0.3–1.8 mm2). Results were robust to the adjustment for age, gender, and neurological severity at baseline. Among wrists with CTS release, those with postoperative CSA of 10 mm2 or less tended to have better clinical outcomes than those with postoperative CSA of greater than 10 mm2 (p=.055). Postoperative sonographic workup in the 3 patients with unfavorable outcome or recurrence identified likely causes for treatment failure in 2 patients. Conclusions In this observational study, surgical decompression was associated with a greater decrease in median nerve CSA than was nonsurgical treatment. Smaller postoperative CSAs may be associated with better clinical outcomes. Additional randomized trials are necessary to determine the optimal treatment strategy in different subgroups of patients with CTS. Type of study/level of evidence Therapeutic III.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution ultrasound is becoming increasingly important in the diagnosis of carpal tunnel syndrome (CTS). Most studies define cut-off values of the cross-sectional area (CSA) of the median nerve in different locations. The individual range of nerve swelling, the size of the nerve, and its CSA are not addressed. The aim of the study is to define the intra- and interobserver reliability of diagnostic ultrasound using two different cross-sectional areas of the median nerve at the carpal tunnel in predefined locations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The objective of this study was to assess three-dimensional bone geometry and density at the epiphysis and shaft of the third meta-carpal bone of rheumatoid arthritis (RA) patients in comparison to healthy controls with the novel method of peripheral quantitative computed tomography (pQCT). Methods PQCT scans were performed in 50 female RA patients and 100 healthy female controls at the distal epiphyses and shafts of the third metacarpal bone, the radius and the tibia. Reproducibility was determined by coefficient of varia-tion. Bone densitometric and geometric parameters were compared between the two groups and correlated to disease characteristics. Results Reproducibility of different pQCT parameters was between 0.7% and 2.5%. RA patients had 12% to 19% lower trabecular bone mineral density (BMD) (P ≤ 0.001) at the distal epiphyses of radius, tibia and metacarpal bone. At the shafts of these bones RA patients had 7% to 16% thinner cortices (P ≤ 0.03). Total cross-sectional area (CSA) at the metacarpal bone shaft of pa-tients was larger (between 5% and 7%, P < 0.02), and relative cortical area was reduced by 13%. Erosiveness by Ratingen score correlated negatively with tra-becular and total BMD at the epiphyses and shaft cortical thickness of all measured bones (P < 0.04). Conclusions Reduced trabecular BMD and thinner cortices at peripheral bones, and a greater bone shaft diameter at the metacarpal bone suggest RA spe-cific bone alterations. The proposed pQCT protocol is reliable and allows measuring juxta-articular trabecular BMD and shaft geometry at the metacarpal bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of giant cell tumor of bone (GCT) often is complicated by local recurrence. Intralesional curettage is the standard of care for primary GCTs. However, there is controversy whether intralesional curettage should be preferred over wide resection in recurrent GCTs.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A life-size mechanical middle ear model and human temporal bones were used to evaluate three different middle ear transducers for implantable hearing aids: the driving rod transducer (DRT), the floating mass transducer (FMT) or vibrant sound bridge, and the contactless transducer (CLT). Results of the experiments with the mechanical model were within the range of the results for human temporal bones. However, results with the mechanical model showed better reproducibility. The handling of the mechanical model was considerably simpler and less time-consuming. Systematic variations of mounting parameters showed that the angle of the rod has virtually no effect on the output of the DRT, the mass loading on the cable of the FMT has a larger impact on the output than does the tightness of crimping, and the output level of the CLT can be increased by 10 dB by optimizing the mounting parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to evaluate the results of fasciocutaneous posterior interosseous artery island flaps in the treatment of recurrent or persistent carpal tunnel compression syndrome (CTS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent clinical trials have reported favorable early results for transpedicular vertebral cement reinforcement of osteoporotic vertebral insufficiencies. There is, however, a lack of basic data on the application, safety and biomechanical efficacy of materials such as polymethyl-methacrylate (PMMA) and calciumphospate (CaP) cements. The present study analyzed 33 vertebral pairs from five human cadaver spines. Thirty-nine vertebrae were osteoporotic (bone mineral density < 0.75 g/cm2), 27 showed nearly normal values. The cranial vertebra of each pair was augmented with either PMMA (Palacos E-Flow) or experimental brushite cement (EBC), with the caudal vertebra as a control. PMMA and EBC were easy to inject, and vertebral fillings of 20-50% were achieved. The maximal possible filling was inversely correlated to the bone mineral density (BMD) values. Cement extrusion into the spinal canal was observed in 12% of cases. All specimens were subjected to axial compression tests in a displacement-controlled mode. From load-displacement curves, the stiffness, S, and the maximal force before failure, Fmax, were determined. Compared with the native control vertebrae, a statistically significant increase in vertebral stiffness and Fmax was observed by the augmentation. With PMMA the stiffness increased by 174% (P = 0.018) and Fmax by 195% (P = 0.001); the corresponding augmentation with EBC was 120% (P = 0.03) and 113% (P = 0.002). The lower the initial BMD, the more pronounced was the augmentation effect. Both PMMA and EBC augmentation reliably and significantly raised the stiffness and maximal tolerable force until failure in osteoporotic vertebral bodies. In non-porotic specimens, no significant increase was achieved.