Resumo:
Textile industry has been a cause of environmental pollution, mainly due to the generation of large volumes of waste containing high organic loading and intense color. In this context, this study evaluated the electrochemical degradation of synthetic effluents from textile industry containing Methylene Blue (AM) dye, using Ti/IrO2-Ta2O5 and Ti/Pt anodes, by direct and indirect (active chlorine) electrooxidation. We evaluated the influence of applied current density (20, 40 and 60 mA/cm2 ), and the presence of different concentrations of electrolyte (NaCl and Na2SO4), as well as the neutral and alkaline pH media. The electrochemical treatment was conducted in a continuous flow reactor, in which the electrolysis time of the AM 100 ppm was 6 hours. The performance of electrochemical process was evaluated by UV-vis spectrophotometry, chemical oxygen demand (COD) and total organic carbon (TOC). The results showed that with increasing current density, it was possible to obtain 100 % of color removal at Ti/IrO2-Ta2O5 and Ti/Pt electrodes. Regarding the color removal efficiency, increasing the concentration of electrolyte promotes a higher percentage of removal using 0,02 M Na2SO4 and 0,017 M NaCl. Concerning to the aqueous medium, the best color removal results were obtained in alkaline medium using Ti/Pt. In terms of organic matter, 86 % was achieved in neutral pH medium for Ti/Pt; while a 30 % in an alkaline medium. To understand the electrochemical behavior due to the oxygen evolution reaction, polarization curves were registered, determining that the presence of NaCl in the solution favored the production of active chlorine species. The best results in energy consumption and cost were obtained by applying lower current density (20 mA/cm2 ) in 6 hours of electrolysis.
Resumo:
This work was performing effluent degradation studies by electrochemical treatment. The electrochemical oxidation (EO) hydroquinone (H2Q) was carried out in acid medium, using PbO2 electrode by galvanostatic electrolysis, applying current densities of 10 and 30 mA/cm2 . The concentration of H2Q was monitored by differential pulse voltammetry (DPV). The experimental results showed that the galvanostatic electrolysis process performance significantly depends on the applied current density, achieving removal efficiencies of 100% and 80 % and 10 applying 30 mA/cm2 , respectively. Furthermore, the electroanalytical technique was effective in H2Q be used as a detection method. In order to test the efficiency of PbO2 electrode, the electrochemical treatment was conducted in an actual effluent, leachate from a landfill. The liquid waste leachate (600ml effluent) was treated in a batch electrochemical cell, with or without addition of NaCl by applying 7 mA/cm2 . The efficiency of EO was assessed against the removal of thermo-tolerant coliforms, total organic carbon (TOC), total phosphorus and metals (copper, cobalt, chromium, iron and nickel). These results showed that efficient removal of coliforms was obtained (100%), and was further decrease the concentration of heavy metals by the cathode processes. However, results were not satisfactory TOC, achieving low total removal of dissolved organic load. Because it is considered an effluent complex were developed other tests with this effluent to monitor a larger number of decontamination parameters (Turbidity, Total Solids, Color, Conductivity, Total Organic Carbon (TOC) and metals (barium, chromium, lithium, manganese and Zinc), comparing the efficiency of this type of electrochemical treatment (EO or electrocoagulation) using a flow cell. In this assay was compared to electro streaming. In the case of the OE, Ti/IrO2-TaO5 was used as the anode, however, the electrocoagulation process, aluminum electrodes were used; applying current densities of 10, 20 and 30 mA/cm2 in the presence and absence of NaCl as an electrolyte. The results showed that EO using Ti/IrO2–TaO5 was anode as efficient when Cl- was present in the effluent. In contrast, the electrocoagulation flow reduces the dissolved organic matter in the effluent, under certain experimental conditions.
Resumo:
Electrochemical technologies have been proposed as a promising alternative for the treatment of effluents and contaminated soils. Therefore, the objective of this work was to study the treatment of contaminated soils and wastewaters using electrochemical technologies. Thus, the study regarding the scale-up of the electrochemical system with continuous flow treatment of wastewater of the petrochemical industry was investigated using platinum electrodes supported on titanium (Ti / Pt), and boron-doped diamond (BDD). The results clearly showed that under the operating conditions studied and electrocatalytic materials employed, the better removal efficiency was achieved with BDD electrode reducing the chemical oxygen demand (COD) from 2746 mg L-1 to 200 mg L-1 in 5 h consuming 56.2 kWh m-3 . The decontamination of soils and effluents by petrochemical products was evaluated by studying the effects of electrokinetic remediation for removal of total petroleum hydrocarbons (HTP) from contaminated soil with diesel. The efficiency of this process was dependent on the electrolyte used Na2SO4 (96.46%), citric acid (81.36%) and NaOH (68.03%) for 15 days. Furthermore, the effluent after treatment of the soil was treated by electrochemical oxidation, achieving a good elimination of the organic polluting load dissolved. Depending on the physical behavior of wastewater contaminated with oil (emulsified state); atrazine emulsified effluents were investigated. The main characteristics of the effluent produced during the washing of contaminated soil were studied, being dependent on the surfactant dosage used; which determined its electrolytic treatment with BDD. The electrochemical oxidation of emulsified effluent of atrazine was efficient, but the key to the treatment is reducing the size of micelles.
Resumo:
The treatment of wastewater is essential to human health. One of the most important steps is the disinfection treatment which uses chlorine to eliminate bacteria as required by environmental agencies. However, the identification of potentially toxic byproducts generated by this method, such as trihalomethanes, has stimulated the development of new alternative disinfection technologies. Among them, heterogeneous photocatalysis, TiO2 photocatalysis and electrochemical disinfection are considered suitable alternatives to the chlorination method. Thus, the present dissertation analyzes the evolution of active chlorine species in a synthetic NaCl solution and it is tested to treat a synthetic solution of the dye Reactive Blue 19 using boron-doped diamond (BDD) and ruthenium oxide (Ti/Ru0.3Ti0.7O2) as anodes. The indirect electrochemical process was discussed in terms of mineralization of the total organic load and percentage of color removal in order to evaluate the applicability of electrochemical technology. Electrochemical experiments were carried out with different current densities (25, 50 and 75 mA.cm-2) during 120 minutes. On the other hand, other important parameter in this study was the influence of the proportion sp3/sp2 on BDD anode on the performance of the evolution of active chlorine species which was investigated by electrolytic techniques (linear polarization), with the intention of determining the related training oxidizing species and consumption energy to chemical or electrochemical reactions. From the results, it can be noted that the BDD electrode showed better efficiency throughout the electrochemical process.
Resumo:
The treatment of wastewater is essential to human health. One of the most important steps is the disinfection treatment which uses chlorine to eliminate bacteria as required by environmental agencies. However, the identification of potentially toxic byproducts generated by this method, such as trihalomethanes, has stimulated the development of new alternative disinfection technologies. Among them, heterogeneous photocatalysis, TiO2 photocatalysis and electrochemical disinfection are considered suitable alternatives to the chlorination method. Thus, the present dissertation analyzes the evolution of active chlorine species in a synthetic NaCl solution and it is tested to treat a synthetic solution of the dye Reactive Blue 19 using boron-doped diamond (BDD) and ruthenium oxide (Ti/Ru0.3Ti0.7O2) as anodes. The indirect electrochemical process was discussed in terms of mineralization of the total organic load and percentage of color removal in order to evaluate the applicability of electrochemical technology. Electrochemical experiments were carried out with different current densities (25, 50 and 75 mA.cm-2) during 120 minutes. On the other hand, other important parameter in this study was the influence of the proportion sp3/sp2 on BDD anode on the performance of the evolution of active chlorine species which was investigated by electrolytic techniques (linear polarization), with the intention of determining the related training oxidizing species and consumption energy to chemical or electrochemical reactions. From the results, it can be noted that the BDD electrode showed better efficiency throughout the electrochemical process.
Resumo:
En este trabajo se presenta la descripción e investigación en la evaluación de vetiver (Chrysopogon zizanioides) y la elefanta (Pennisetum purpureum) en el diseño de humedales artificiales. Para el tratamiento de aguas residuales de origen doméstico, siendo la vegetación uno de los principales componentes de estos sistemas de tratamientos no convencionales. Muchos \sistemas naturales" están siendo considerados con el propósito del tratamiento del agua residual y control de la contaminación del agua, debido a su alta fiabilidad ambiental y los bajos costos de construcción y mantenimiento, es el caso de los humedales artificiales. El interés en los sistemas naturales está basado en la conservación de los recursos asociados con estos sistemas como opuesto al proceso de tratamiento convencional de aguas residuales que es intensivo respecto al uso de energía y químicos. Los wetlands o humedales artificiales constituyen una alternativa de tratamiento debido a su alta eficiencia de remoción de contaminantes, a su bajo costo de instalación y mantenimiento y a su alta fiabilidad ambiental, generalmente un humedal artificial esta constituido por un medio de soporte el cual generalmente es arena o grava, vegetación y microorganismos o biopelícula los cuales llevan los diferentes procesos bioquímicos para remover los contaminantes del afluente. El objetivo general de este trabajo ha sido: Evaluar la eficiencia de remoción de materia orgánica, sólidos, nitrógeno y fósforo total de dos especies de plantas: vetiver (Chrysopogon zizanioides) y la elefanta (Pennisetum purpureum), en el diseño de humedales artificiales para el tratamiento de aguas residuales de origen doméstico. Los humedales artificiales o sistemas pilotos, se encuentran ubicados en la universidad de Medellín y reciben una preparación de agua sintética, que asemeja a las características de un agua residual de origen doméstico. En el presente trabajo se evalúa el porcentaje de remoción de la carga orgánica de aguas residuales, en un sistema de tratamiento por humedales artificiales con dos especies vegetales. El sistema fue diseñado con tres módulos instalados de manera adjunta. En el primero no se integra ninguna especie vegetal, solo el medio de sustrato el cual constituye el blanco (-), en el segundo se integraron organismos de la especie vetiver (Chrysopogon zizanioides), en el tercer sistema piloto, organismos de la especie elefanta (Pennisetum purpureum) y en el cuarto organismos de la especie papiro japones (Cyperus alternifolius), los cuales constituyen el control positivo (+). Los módulos experimentales fueron limpiados, cortados y adecuados acorde al montaje inicial de las plantas y al espacio requerido para su disposición. A cada sistema piloto se le agrega medio de soporte constituido por grava (5 a 10 cm) y arena (15 a 20 cm), el sustrato es evaluado y caracterizado por su diámetro nominal, posterior en cada sistema se siembran las especies en un área de 3x3 y cada humedal por dos semanas se adecua bajo la solución de Hoagland y Arnon y régimen de humedad. En el agua sintética se analizaron los siguientes parámetros: pH, sólidos totales, sólidos suspendido totales, sólidos disueltos totales, demanda química de oxígeno (DQO), demanda bioquímica de oxígeno (DBO5), nitrógeno total (NTK) y fosforo total (PT). También se realizó la determinación del crecimiento de las plantas a partir del incremento de biomasa, porosidad de la raíz y de igual forma se determina NTK y PT. Los resultados demostraron que el sistema es una opción para la remoción de la carga orgánica y de nutrientes en aguas residuales de origen doméstico, de bajo costo de operación y mantenimiento, especialmente se observa que las plantas que crecen en sistemas de régimen de humedad ácuico y ústico, tienden a tener una mayor recepción y adaptación en los humedales artificiales pilotos, es el caso de la elefanta (Pennisetum purpureum), el cual presenta las más altas tasas de remoción de contaminantes y nutrientes en el afluente, seguido por el papiro japonés (Cyperus alternifolius) y el vetiver (Chrysopogon zizanioides), respecto a tasas de remoción. La remoción de contaminantes que se presentan más altos respectivamente, constituyen sólidos en primera instancia, seguido por la demanda bioquímica de oxigeno (DBO5), demanda química de oxígeno (DQO), nitrógeno total (NTK) y fósforo total (PT), estos últimos presentan una baja tasa de remoción, debido a la naturaleza misma del contaminante, a los organismos que realizan la remoción y absorción y al tiempo de retención que se elige, el cual influye en la tasa de remoción del contaminante siendo menor en la concentración de fósforo, pero se encuentranen el rango esperado para estos sistemas de tratamiento no convencionales.
Resumo:
Dissertação composta por 2 artigos.
Resumo:
Untreated effluents that reach surface water affect the aquatic life and humans. This study aimed to evaluate the wastewater s toxicity (municipal, industrial and shrimp pond effluents) released in the Estuarine Complex of Jundiaí- Potengi, Natal/RN, through chronic quantitative e qualitative toxicity tests using the test organism Mysidopsis Juniae, CRUSTACEA, MYSIDACEA (Silva, 1979). For this, a new methodology for viewing chronic effects on organisms of M. juniae was used (only renewal), based on another existing methodology to another testorganism very similar to M. Juniae, the M. Bahia (daily renewal).Toxicity tests 7 days duration were used for detecting effects on the survival and fecundity in M. juniae. Lethal Concentration 50% (LC50%) was determined by the Trimmed Spearman-Karber; Inhibition Concentration 50% (IC50%) in fecundity was determined by Linear Interpolation. ANOVA (One Way) tests (p = 0.05) were used to determinate the No Observed Effect Concentration (NOEC) and Low Observed Effect Concentration (LOEC). Effluents flows were measured and the toxic load of the effluents was estimated. Multivariate analysis - Principal Component Analysis (PCA) and Correspondence Analysis (CA) - identified the physic-chemical parameters better explain the patterns of toxicity found in survival and fecundity of M. juniae. We verified the feasibility of applying the only renewal system in chronic tests with M. Juniae. Most efluentes proved toxic on the survival and fecundity of M. Juniae, except for some shrimp pond effluents. The most toxic effluent was ETE Lagoa Aerada (LC50, 6.24%; IC50, 4.82%), ETE Quintas (LC50, 5.85%), Giselda Trigueiro Hospital (LC50, 2.05%), CLAN (LC50, 2.14%) and COTEMINAS (LC50, IC50 and 38.51%, 6.94%). The greatest toxic load was originated from ETE inefficient high flow effluents, textile effluents and CLAN. The organic load was related to the toxic effects of wastewater and hospital effluents in survival of M. Juniae, as well as heavy metals, total residual chlorine and phenols. In industrial effluents was found relationship between toxicity and organic load, phenols, oils and greases and benzene. The effects on fertility were related, in turn, with chlorine and heavy metals. Toxicity tests using other organisms of different trophic levels, as well as analysis of sediment toxicity are recommended to confirm the patterns found with M. Juniae. However, the results indicate the necessity for implementation and improvement of sewage treatment systems affluent to the Potengi s estuary
Resumo:
The textile industry generates a large volume of high organic effluent loading whoseintense color arises from residual dyes. Due to the environmental implications caused by this category of contaminant there is a permanent search for methods to remove these compounds from industrial waste waters. The adsorption alternative is one of the most efficient ways for such a purpose of sequestering/remediation and the use of inexpensive materials such as agricultural residues (e.g., sugarcane bagasse) and cotton dust waste (CDW) from weaving in their natural or chemically modified forms. The inclusion of quaternary amino groups (DEAE+) and methylcarboxylic (CM-) in the CDW cellulosic structure generates an ion exchange capacity in these formerly inert matrix and, consequently, consolidates its ability for electrovalent adsorption of residual textile dyes. The obtained ionic matrices were evaluated for pHpcz, the retention efficiency for various textile dyes in different experimental conditions, such as initial concentration , temperature, contact time in order to determine the kinetic and thermodynamic parameters of adsorption in batch, turning comprehensive how does occur the process, then understood from the respective isotherms. It was observed a change in the pHpcz for CM--CDW (6.07) and DEAE+-CDW (9.66) as compared to the native CDW (6.46), confirming changes in the total surface charge. The ionized matrices were effective for removing all evaluated pure or residual textile dyes under various tested experimental conditions. The kinetics of the adsorption process data had best fitted to the model a pseudosecond order and an intraparticle diffusion model suggested that the process takes place in more than one step. The time required for the system to reach equilibrium varied according to the initial concentration of dye, being faster in diluted solutions. The isotherm model of Langmuir was the best fit to the experimental data. The maximum adsorption capacity varied differently for each tested dye and it is closely related to the interaction adsorbent/adsorbate and dye chemical structure. Few dyes obtained a linear variation of the balance ka constant due to the inversion of temperature and might have influence form their thermodynamic behavior. Dyes that could be evaluated such as BR 18: 1 and AzL, showed features of an endothermic adsorption process (ΔH° positive) and the dye VmL presented exothermic process characteristics (ΔH° negative). ΔG° values suggested that adsorption occurred spontaneously, except for the BY 28 dye, and the values of ΔH° indicated that adsorption occurred by a chemisorption process. The reduction of 31 to 51% in the biodegradability of the matrix after the dye adsorption means that they must go through a cleaning process before being discarded or recycled, and the regeneration test indicates that matrices can be reused up to five times without loss of performance. The DEAE+-CDW matrix was efficient for the removal of color from a real textile effluent reaching an UV-Visible spectral area decrease of 93% when applied in a proportion of 15 g ion exchanger matrix L-1 of colored wastewater, even in the case of the parallel presence of 50 g L-1 of mordant salts in the waste water. The wide range of colored matter removal by the synthesized matrices varied from 40.27 to 98.65 mg g-1 of ionized matrix, obviously depending in each particular chemical structure of the dye upon adsorption.
Resumo:
Untreated effluents that reach surface water affect the aquatic life and humans. This study aimed to evaluate the wastewater s toxicity (municipal, industrial and shrimp pond effluents) released in the Estuarine Complex of Jundiaí- Potengi, Natal/RN, through chronic quantitative e qualitative toxicity tests using the test organism Mysidopsis Juniae, CRUSTACEA, MYSIDACEA (Silva, 1979). For this, a new methodology for viewing chronic effects on organisms of M. juniae was used (only renewal), based on another existing methodology to another testorganism very similar to M. Juniae, the M. Bahia (daily renewal).Toxicity tests 7 days duration were used for detecting effects on the survival and fecundity in M. juniae. Lethal Concentration 50% (LC50%) was determined by the Trimmed Spearman-Karber; Inhibition Concentration 50% (IC50%) in fecundity was determined by Linear Interpolation. ANOVA (One Way) tests (p = 0.05) were used to determinate the No Observed Effect Concentration (NOEC) and Low Observed Effect Concentration (LOEC). Effluents flows were measured and the toxic load of the effluents was estimated. Multivariate analysis - Principal Component Analysis (PCA) and Correspondence Analysis (CA) - identified the physic-chemical parameters better explain the patterns of toxicity found in survival and fecundity of M. juniae. We verified the feasibility of applying the only renewal system in chronic tests with M. Juniae. Most efluentes proved toxic on the survival and fecundity of M. Juniae, except for some shrimp pond effluents. The most toxic effluent was ETE Lagoa Aerada (LC50, 6.24%; IC50, 4.82%), ETE Quintas (LC50, 5.85%), Giselda Trigueiro Hospital (LC50, 2.05%), CLAN (LC50, 2.14%) and COTEMINAS (LC50, IC50 and 38.51%, 6.94%). The greatest toxic load was originated from ETE inefficient high flow effluents, textile effluents and CLAN. The organic load was related to the toxic effects of wastewater and hospital effluents in survival of M. Juniae, as well as heavy metals, total residual chlorine and phenols. In industrial effluents was found relationship between toxicity and organic load, phenols, oils and greases and benzene. The effects on fertility were related, in turn, with chlorine and heavy metals. Toxicity tests using other organisms of different trophic levels, as well as analysis of sediment toxicity are recommended to confirm the patterns found with M. Juniae. However, the results indicate the necessity for implementation and improvement of sewage treatment systems affluent to the Potengi s estuary
Resumo:
A química do solo vem estudando o comportamento da fração mineral dos solos tropicais intemperizados, incluindo a eletroquímica, o desenvolvimento de cargas e o fenômeno de adsorção. Por causa do amplo espectro a ser coberto no entendimento do comportamento da fração mineral, somado às dificuldades metodológicas, o estudo da complexa fração orgânica dos solos foi relativamente menos desenvolvido. A atual proposta revisita os primeiros trabalhos referentes à química de solos tropicais, buscando relacioná-los com dados de eletroquímica dos estoques de carbono do solo. O objetivo deste trabalho foi revisar aspectos de eletroquímica de solos, determinar e relacionar os pontos de carga zero, por diferentes métodos, os potenciais da dupla camada elétricae a eletroquímica do húmus de solos modais brasileiros, em uma sequência típica de intemperismo, visando a gerar informações para o seu manejo e conservação. Os métodos de estimativa dos ponto de carga zero dos solos apresentam resultados variados, mas com a mesma tendência entre os solos. Há predomínio de cargas negativas em ambas as camadas dos solos estudados. As cargas negativas dos coloides estão diretamente associadas à disponibilidade de elétrons do húmus e ambas diminuem com o estádio de intemperismo do solo.
Resumo:
RESUMO Objetivo Identificar os fatores associados à carga de trabalho de enfermagem no cuidado a pacientes no pós-operatório de cirurgia cardíaca. Método Estudo de coorte prospectivo, conduzido com 187 pacientes da Unidade de Terapia Intensiva Cirúrgica (UTI) do Instituto do Coração. Os dados foram coletados nas primeiras 24 e 72 horas do paciente na UTI. A variável dependente foi a carga de trabalho calculada por meio do Nursing Activities Score (NAS) e as independentes foram de natureza demográfico-clínicas e escores de morbimortalidade. Para análise dos dados utilizou-se os testes de Wilcoxon-Mann-Whitney e de correlação de Spearman, e a regressão linear com modelo de efeitos mistos. Resultados A maioria dos pacientes era do sexo masculino (59,4%), com média de idade de 61 anos (±12,7) e 43,9% desenvolveram algum tipo de complicação no pós-operatório. Nas 24 horas, a carga de trabalho foi de 82,4% (±3,4) e foi de 58,1% (±3,4) nas 72 horas. Os fatores associados ao aumento do NAS foram: tempo de internação do paciente na UTI (p=0,036) e a presença de complicações (p<0,001). Conclusão A gravidade do paciente nas 24 horas, em oposição a inúmeros estudos, não influenciou no aumento da carga de trabalho, a qual se mostrou associada ao tempo de internação e às complicações.
Resumo:
Um Latossolo Vermelho-Amarelo com mineralogia predominantemente gibbsítica e com caráter eletropositivo foi utilizado para estudos de propriedades eletroquímicas e mecanismos de dispersão, diante da adição de matéria orgânica. Foram utilizadas duas fontes orgânicas, caracterizadas como material não humificado (esterco) e humificado (ácido húmico extraído de turfa). Porções de solo foram incubadas com doses de 0; 7,5; 15,0; 22,5; e 30,0 g kg-1 dos adubos orgânicos. Foram analisados argila dispersa em água, condutividade elétrica, pH em água e em KCl, bem como determinados o ponto de efeito salino nulo (PESN) e o potencial elétrico superficial (Ψo). Observou-se comportamento distinto entre os tratamentos com esterco e com ácidos húmicos em relação à dispersão de argilas. A adição de esterco provocou aumento da dispersão, o que pode estar relacionado com o aumento da condutividade elétrica pela presença de sais. Por outo lado, a adição de ácido húmico promoveu a floculação das argilas, em decorrência, provavelmente, da formação de complexos argilo-húmicos. O PESN decresceu linearmente com a adição dos adubos orgânicos, principalmente nos tratamentos com ácido húmico. A floculação não esteve obrigatoriamente associada a uma condição de baixo módulo de Ψo. Nos tratamentos com doses mais elevadas de ácido húmico, foi observada carga negativa, apesar de não se observar dispersão de argila, provavelmente pelo fato de os ácidos húmicos apresentarem propriedades eletroquímicas distintas da matriz mineral, em função da sua condição de polieletrólito e da possibilidade de alteração na configuração da macromolécula.
Resumo:
O Estado de Minas Gerais é o maior produtor de café do Brasil, com mais de 50 % da produção total, sendo grande parte da área cultivada originalmente ocupada por vegetação de cerrado. Essa região é destaque na cafeicultura em razão da alta tecnologia empregada na mecanização, que submete o solo ao tráfego de máquinas, tornando preocupante a possibilidade de disseminação da compactação do solo. Objetivou-se com este estudo: (a) propor modelos de capacidade de suporte de carga de um Latossolo Amarelo distrófico típico (LAd) cultivado com cafeeiro em função da pressão de preconsolidação e da umidade, (b) determinar, com o uso destes modelos, em três profundidades e em duas épocas de amostragem, a influência das operações de manejo na estrutura do Latossolo Amarelo nas estações: seca e chuvosa. As amostragens foram realizadas em três camadas (0-3, 10-13 e 25-28 cm), sendo 30 amostras coletadas no local onde não houve tráfego e 10 amostras na linha de tráfego para cada equipamento, coletadas nos meses de agosto de 2002 e março de 2003 para quantificar seu efeito na estrutura do solo nas duas épocas: seca e chuvosa, respectivamente. As amostras indeformadas foram utilizadas nos ensaios de compressão uniaxial. Foram determinados também granulometria, matéria orgânica, densidade de partículas, limite de contração e limite de plasticidade do solo. O modelo de capacidade de suporte de carga do LAd é expresso pela equação sigmap = 10(2,72-1,17U), em que sigmap significa a pressão de preconsolidação e U a umidade. Os efeitos das operações mecanizadas na lavoura cafeeira foram quantificados com o modelo de capacidade de suporte de carga e com o seu uso foi possível quantificar a influência das operações de manejo na estrutura do Latossolo Amarelo distrófico típico.
Resumo:
A eletroquímica e a concentração de matéria orgânica nos horizontes superficiais de Latossolos correlacionam-se estreitamente. No presente trabalho, avaliaram-se as propriedades eletroquímicas do horizonte superficial de sete Latossolos brasileiros após a remoção das substâncias húmicas em meio alcalino. Os solos foram separados em dois grupos, segundo sua mineralogia, caulinítica e oxídica. O extrator NaOH 0,1 mol L-1 solubilizou substâncias húmicas correspondentes a menos de 3 % da MO total, indicando forte adsorção específica do material orgânico à fração mineral. A extração de ácidos húmicos e fúlvicos foi capaz de inverter o sinal de carga da superfície; no entanto, o efeito mais acentuado da retirada das substâncias húmicas solúveis foi a perda da capacidade-tampão das cargas do solo. A capacidade da dupla camada elétrica, uma medida indireta desse poder-tampão, aumentou de 3 a 15 vezes depois da extração das substâncias húmicas alcalino-solúveis. Solos com mineralogia predominantemente oxídica apresentaram maiores valores do ponto de efeito salino nulo, da capacidade da dupla camada elétrica, além da diminuição na capacidade de troca de cátions do que aqueles de natureza caulinítica.