Background: Evidence demonstrates self-management programs are an effective approach to assist patients with chronic diseases such as type 2 diabetes or cardiac conditions to modify their lifestyle for better managing their conditions. Using information technology (IT) has great potential to support self-management programs and assist patients to fulfill their goals in managing their conditions more efficiently and effectively. Examples of different types of technology used in self-management programs that have limited research support include: text messages, telephone followup, web-based programs, and other internet-assisted education. But little is known about the applicability and feasiability of different forms of technology for patients with chronic diseases such as those with type 2 diabetes and critical cardiac conditions. Furthermore, although there is some evidence of the benefits of using IT in supporting self-management programs, further research on the use of IT in such programs is recommended. Objective: To develop and pilot test an integrated Cardiac- Diabetes Self-Management Program (CDSMP) incorporating telephone and text-message follow-up. Methods: A pilot study using randomised controlled trial is conducted in the coronary care unit (CCU) in a Brisbane metropolitan hospital in Australia to collect data on patients with type 2 diabetes admitted to CCU. The main outcomes included self-efficacy levels, knowledge, and quality of life. Results: Initial results reveal that patients with diabetes admitted to the CCU in the experimental group did improve their self-efficacy, and knowledge levels. Acknowledgements: This Project is funded by QUT Early Career Researcher Research Grant

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Smoking cessation has been shown to be an important intervention for preventing cardiovascular events and improving the health of patients with heart disease. However, unaided quit attempts in these patients often leads to high rates of failure and a return to smoking. Outpatient smoking cessation clinics using face-to-face counseling, ongoing behavioral support, advice on smoking pharmacotherapy and objective monitoring, have been found to be one of the most effective interventions for improving quit smoking rates. An outpatient smoking cessation clinic was trialed within a cardiac rehabilitation service in order to explore its effects on smoking rates for patients with or at risk of heart disease. Attendance rates to the clinic were also monitored. Methods: A descriptive exploratory design was used for this newly developed clinic. Patients who currently smoked tobacco and who had a history of either coronary artery disease, heart failure, atrial fibrillation or those seen under a chest pain assessment service were invited to an outpatient ‘Cardiac Patients Smokers Clinic’. Initially patients were offered up to 10 clinic visits over a 3 month period. Follow-up clinic visits were conducted at 3, 6 and 12 months. A portable carbon monoxide meter was used to objectively measure levels of smoking and validate smoking abstinence. Primary outcomes included rates of attendance. Results: Preliminary findings showed 24 per cent of participants (N = 6) completed all their clinic visits and remained smoke free as measured by their ongoing expired carbon monoxide readings. Clinic attendance rates appeared lowest for those with significant mental health issues such as schizophrenia or substance abuse. However, rates of attendance were improved by having an administration officer make reminder telephone calls prior to clinic visits. Conclusions: Early findings indicate the feasibility of providing a specialist smoking cessation clinic within a cardiac rehabilitation service. Further, that reminder telephone calls prior to appointments improved attendance rates in patients with heart disease to this type of clinic. However, future investigations are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cardiac patients with diabetes are at higher readmission rates (22%) compared to only 6% for those patients without diabetes. Evidence shows benefits of peer support and using information technology to improve chronic illness and achieve better health outcomes. However limited evidence suggests that cardiac or diabetes self-management programs incorporating peer supporters (patients with similar conditions) or telephone and text-messaging, have improved health outcomes and reduce health care utilisations. A multidisciplinary research team approach is crucial to accommodate the complex aspects of delivering intervention programs for these at-risk patients. However, challenges such as the inconsistency in significance of key concepts across research fields, as well as practical and operational issues within different contexts are often experienced. Aims: To develop an effective multidisciplinary team approach to deliver a peer support based cardiac-diabetes self-management program incorporating the preparation of lay personnel to provide telephone and text-messaging follow up support. Methods: The approach was used for a multidisciplinary project using randomised controlled trial. Results: The findings from multidisciplinary team approach reveal the feasibility of a Peer support based cardiac-diabetes self-management program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone for the assessment of osteoporosis follows a parabolic-type dependence with bone volume fraction; having minima values corresponding to both entire bone and entire marrow. Langton has recently proposed that the primary BUA mechanism may be significant phase interference due to variations in propagation transit time through the test sample as detected over the phase-sensitive surface of the receive ultrasound transducer. This fundamentally simple concept assumes that the propagation of ultrasound through a complex solid : liquid composite sample such as cancellous bone may be considered by an array of parallel ‘sonic rays’. The transit time of each ray is defined by the proportion of bone and marrow propagated, being a minimum (tmin) solely through bone and a maximum (tmax) solely through marrow. A Transit Time Spectrum (TTS), ranging from tmin to tmax, may be defined describing the proportion of sonic rays having a particular transit time, effectively describing lateral inhomogeneity of transit time over the surface of the receive ultrasound transducer. Phase interference may result from interaction of ‘sonic rays’ of differing transit times. The aim of this study was to test the hypothesis that there is a dependence of phase interference upon the lateral inhomogenity of transit time by comparing experimental measurements and computer simulation predictions of ultrasound propagation through a range of relatively simplistic solid:liquid models exhibiting a range of lateral inhomogeneities. Methods: A range of test models was manufactured using acrylic and water as surrogates for bone and marrow respectively. The models varied in thickness in one dimension normal to the direction of propagation, hence exhibiting a range of transit time lateral inhomogeneities, ranging from minimal (single transit time) to maximal (wedge; ultimately the limiting case where each sonic ray has a unique transit time). For the experimental component of the study, two unfocused 1 MHz ¾” broadband diameter transducers were utilized in transmission mode; ultrasound signals were recorded for each of the models. The computer simulation was performed with Matlab, where the transit time and relative amplitude of each sonic ray was calculated. The transit time for each sonic ray was defined as the sum of transit times through acrylic and water components. The relative amplitude considered the reception area for each sonic ray along with absorption in the acrylic. To replicate phase-sensitive detection, all sonic rays were summed and the output signal plotted in comparison with the experimentally derived output signal. Results: From qualtitative and quantitative comparison of the experimental and computer simulation results, there is an extremely high degree of agreement of 94.2% to 99.0% between the two approaches, supporting the concept that propagation of an ultrasound wave, for the models considered, may be approximated by a parallel sonic ray model where the transit time of each ray is defined by the proportion of ‘bone’ and ‘marrow’. Conclusions: This combined experimental and computer simulation study has successfully demonstrated that lateral inhomogeneity of transit time has significant potential for phase interference to occur if a phase-sensitive ultrasound receive transducer is implemented as in most commercial ultrasound bone analysis devices.