988 resultados para Cam
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. This study aimed to investigate the influence of restoration thickness to the fracture resistance of adhesively bonded Lava (TM) Ultimate CAD/CAM, a Resin Nano Ceramic(RNC), and IPS e. max CAD ceramic.Methods. Polished Lava (TM) Ultimate CAD/CAM (Group L), sandblasted Lava (TM) Ultimate CAD/CAM (Group LS), and sandblasted IPS e.max CAD (Group ES) discs (n=8, phi=10 mm) with a thickness of respectively 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm, and 3.0 mm were cemented to corresponding epoxy supporting discs, achieving a final thickness of 3.5 mm. All the 120 specimens were loaded with a universal testing machine at a crosshead speed of 1 mm/min. The load (N) at failure was recorded as fracture resistance. The stress distribution for 0.5 mm restorative discs of each group was analyzed by Finite Element Analysis (FEA). The results of facture resistances were analyzed by one-way ANOVA and regression.Results. For the same thickness of testing discs, the fracture resistance of Group L was always significantly lower than the other two groups. The 0.5 mm discs in Group L resulted in the lowest value of 1028 (112) N. There was no significant difference between Group LS and Group ES when the restoration thickness ranged between 1.0 mm and 2.0 mm. There was a linear relation between fracture resistance and restoration thickness in Group L (R = 0.621, P < 0.001) and in Group ES (R = 0.854, P < 0.001). FEA showed a compressive permanent damage in all groups.Significance. The materials tested in this in vitro study with the thickness above 0.5 mm could afford the normal bite force. When Lava Ultimate CAD/CAM is used, sandblasting is suggested to get a better bonding. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
L’obbiettivo di una ricostruzione micro vascolare di mandibola è quello di assicurare al paziente il miglior risultato estetico e funzionale auspicabile. Ciò può essere conseguito utilizzando il lembo microvascolare di perone/cresta iliaca e una placca ricostruttiva in titanio che funga da guida nella fase di modellamento del lembo per ricreare un contorno parabolico il più possibile simile al profilo mandibolare originario del paziente. Il modellamento manuale ed artigianale intraoperatorio di una placca ricostruttiva è operatore dipendente ed anche in mani molto abili o ricorrendo a modelli anatomici stereolitografici non sempre risulta preciso quanto voluto e spesso non porta ai risultati postoperatori attesi e desiderati. Obbiettivo del nostro studio è stato pertanto, sfruttando le moderne tecnologie CAD-CAM, la produzione di placche ricostruttive “custom -made” progettate direttamente al computer ricreanti il profilo osseo originale del paziente.
Resumo:
In Italia hanno visto stampanti 3D commerciali, e grazie al gruppo di professori e ricercatori della Facoltà di Ingegneria Meccanica dell'Università di Bologna, con cui ho avuto la possibilità di realizzare questa tesi, è nato il progetto di una stampante 3D ibrida, dotata sia di una fresatrice che di un estrusore: una stampante talmente grande che si va a posizionare come la stampante più grande di tutta Italia. Il mio progetto, si chiama PrinterCAD, è in grado infatti di gestire le diverse fasi della stampa 3D ibrida con i necessari parametri di lavorazione e controllo. Questo applicazione è un modulo realizzato in Python e segue la filosofia del MVC; inoltre estende il software opensource FreeCAD.
Resumo:
This in vitro study evaluated the performance of three ceramic and two commonly used polishing methods on two CAD/CAM ceramics. Surface roughness and quality were compared. A glazed group (GLGR) of each ceramic material served as reference. One-hundred and twenty specimens of VITABLOCS Mark II (VITA) and 120 specimens of IPS Empress CAD (IPS) were roughened in a standardized manner. Twenty VITA and 20 IPS specimens were glazed (VITA Akzent Glaze/Empress Universal Glaze). Five polishing methods were investigated (n=20/group): 1) EVE Diacera W11DC-Set (EVE), 2) JOTA 9812-Set (JOTA), 3) OptraFine-System (OFI), 4) Sof-Lex 2382 discs (SOF) and 5) Brownie/Greenie/Occlubrush (BGO). Polishing quality was measured with a surface roughness meter (Ra and Rz values). The significance level was set at alpha=0.05. Kruskal Wallis tests and pairwise Wilcoxon rank sum tests with Bonferroni-Holm adjustment were used. Qualitative surface evaluation of representative specimens was done with SEM. On VITA ceramics, SOF produced lower Ra (p<0.00001) but higher Rz values than GLGR (p=0.003); EVE, JOTA, OFI and BGO yielded significantly higher Ra and Rz values than GLGR. On IPS ceramics, SOF and JOTA exhibited lower Ra values than GLGR (p<0.0001). Equivalent Ra but significantly higher Rz values occurred between GLGR and EVE, OFI or BGO. VITA and IPS exhibited the smoothest surfaces when polished with SOF. Nevertheless, ceramic polishing systems are still of interest to clinicians using CAD/CAM, as these methods are universally applicable and showed an increased durability compared to the investigated silicon polishers.
Resumo:
OBJECTIVES: This study evaluated the initial and the artificially aged push-out bond strength between ceramic and dentin produced by one of five resin cements. METHODS: Two-hundred direct ceramic restorations (IPS Empress CAD) were luted to standardized Class I cavities in extracted human molars using one of four self-adhesive cements (SpeedCEM, RelyX Unicem Aplicap, SmartCem2 and iCEM) or a reference etch-and-rinse resin cement (Syntac/Variolink II) (n=40/cement). Push-out bond strength (PBS) was measured (1) after 24h water storage (non-aged group; n=20/cement) or (2) after artificial ageing with 5000 thermal cycles followed by 6 months humid storage (aged group; n=20/cement). Nonparametrical ANOVA and pairwise Wilcoxon rank-sum tests with Bonferroni-Holm adjustment were applied for statistical analysis. The significance level was set at alpha=0.05. In addition, failure mode and fracture pattern were analyzed by stereomicroscope and scanning electron microscopy. RESULTS: Whereas no statistically significant effect of storage condition was found (p=0.441), there was a significant effect of resin cement (p<0.0001): RelyX Unicem showed significantly higher PBS than the other cements. Syntac/Variolink II showed significantly higher PBS than SmartCEM2 (p<0.001). No significant differences were found between SpeedCEM, SmartCem2, and iCEM. The predominant failure mode was adhesive failure of cements at the dentin interface except for RelyX Unicem which in most cases showed cohesive failure in ceramic. SIGNIFICANCE: The resin cements showed marked differences in push-out bond strength when used for luting ceramic restorations to dentin. Variolink II with the etch-and-rinse adhesive Syntac did not perform better than three of the four self-adhesive resin cements tested.
Resumo:
Objective To determine the prevalence of cam-type deformities on hip magnetic resonance imaging (MRI) in young males. Methods This was a population-based cross-sectional study in young asymptomatic male individuals who underwent clinical examination and completed a self-report questionnaire. A random sample of participants was invited for MRI of the hip. We graded the maximal offset at the femoral head–neck junction on radial sequences using grades from 0 to 3, where 0 = normal, 1 = possible, 2 = definite, and 3 = severe deformity. The prespecified main analyses were based on definite cam-type deformity grades 2 or 3. We estimated the prevalence of the cam-type deformity adjusted for the sampling process overall and according to the extent of internal rotation. Then we determined the location of the deformity on radial MRI sequences. Results A total of 1,080 subjects were included in the study and 244 asymptomatic males with a mean age of 19.9 years attended MRI. Sixty-seven definite cam-type deformities were detected. The adjusted overall prevalence was 24% (95% confidence interval [95% CI] 19–30%). The prevalence increased with decreasing internal rotation (P < 0.001 for trend). Among those with a clinically decreased internal rotation of <30°, the estimated prevalence was 48% (95% CI 37–59%). Sixty-one of 67 cam-type deformities were located in an anterosuperior position. Conclusion Cam-type deformities can be found on MRI in every fourth young asymptomatic male individual and in every second male with decreased internal rotation. The majority of deformities are located in an anterosuperior position.