945 resultados para Calculated Partial Charges


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Functional brain variability has been scarcely investigated in cognitively healthy elderly subjects, and it is currently debated whether previous findings of regional metabolic variability are artifacts associated with brain atrophy. The primary purpose of this study was to test whether there is regional cerebral age-related hypometabolism specifically in later stages of life. MATERIALS AND METHODS: MR imaging and FDG-PET data were acquired from 55 cognitively healthy elderly subjects, and voxel-based linear correlations between age and GM volume or regional cerebral metabolism were conducted by using SPM5 in images with and without correction for PVE. To investigate sex-specific differences in the pattern of brain aging, we repeated the above voxelwise calculations after dividing our sample by sex. RESULTS: Our analysis revealed 2 large clusters of age-related metabolic decrease in the overall sample, 1 in the left orbitofrontal cortex and the other in the right temporolimbic region, encompassing the hippocampus, the parahippocampal gyrus, and the amygdala. The division of our sample by sex revealed significant sex-specific age-related metabolic decrease in the left temporolimbic region of men and in the left dorsolateral frontal cortex of women. When we applied atrophy correction to our PET data, none of the above-mentioned correlations remained significant. CONCLUSIONS: Our findings suggest that age-related functional brain variability in cognitively healthy elderly individuals is largely secondary to the degree of regional brain atrophy, and the findings provide support to the notion that appropriate PVE correction is a key tool in neuroimaging investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To assess the cost effectiveness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in patients with Hodgkin`s lymphoma (HL) with unconfirmed complete remission (CRu) or partial remission (PR) after first-line treatment. Patients and Methods One hundred thirty patients with HL were prospectively studied. After treatment, all patients with CRu/PR were evaluated with FDG-PET. In addition, PET-negative patients were evaluated with standard follow-up, and PET-positive patients were evaluated with biopsies of the positive lesions. Local unit costs of procedures and tests were evaluated. Cost effectiveness was determined by evaluating projected annual economic impact of strategies without and with FDG-PET on HL management. Results After treatment, CRu/PR was observed in 50 (40.0%) of the 127 patients; the sensitivity, specificity, and positive and negative predictive values of FDG-PET were 100%, 92.0%, 92.3%, and 100%, respectively (accuracy of 95.9%). Local restaging costs without PET were $350,050 compared with $283,262 with PET, a 19% decrease. The incremental cost-effectiveness ratio is -$3,268 to detect one true case. PET costs represented 1% of total costs of HL treatment. Simulated costs in the 974 patients registered in the 2008 Brazilian public health care database showed that the strategy including restaging PET would have a total program cost of $56,498,314, which is $516,942 less than without restaging PET, resulting in a 1% cost saving. Conclusion FDG-PET demonstrated 95.9% accuracy in restaging for patients with HL with CRu/PR after first-line therapy. Given the observed probabilities, FDG-PET is highly cost effective and would reduce costs for the public health care program in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sotos syndrome (MIM #117550) is an autosomal dominant condition characterized by pre and postnatal overgrowth, macrocephaly and typical facial gestalt with frontal bossing, hypertelorism, antimongoloid slant of the palpebral fissures, prominent jaw and high and narrow palate. This syndrome is also frequently associated with brain, cardiovascular, and urinary anomalies and is occasionally accompanied by malignant lesions such as Wilms turnout and hepatocarcinoma. The syndrome is known to be caused by mutations or deletions of the NSD1 gene. To detect both 5q35 microdeletions and partial NSD1 gene deletions we screened 30 Brazilian patients with clinical diagnosis of Sotos syndrome by multiplex ligation dependent probe amplification. We identified one patient with a total deletion of NSD1 and neighbouring FGFR4, other with missing NSD1 exons 13-14 and another with a deletion involving FGFR4 and spanning up to NSD1 exon 17. All deletions were de novo. The two NSD1 partial deletions have not been previously reported. The clinical features of the three patients included a typical facial gestalt with frontal bossing, prominent jaw and high anterior hairline; macrocephaly, dolichocephaly, large hands; neonatal hypotonia and jaundice. All presented normal growth at birth but postnatal overgrowth. Two patients with NSD1 and FGFR4 gene deletions presented congenital heart anomalies. (C) 2009 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatic ischemia followed by reperfusion (IR) results in mild to severe remote organ injury. Oxidative stress and nitric oxide (NO) seem to be involved in the IR injury. Our aim was to investigate the effects of liver I/R on hepatic function and lipid peroxidation, leukocyte infiltration and NO synthase (NOS) immunostaining in the lung and the kidney. We randomized 24 male Wistar rats into 3 groups: 1) control; 2) 60 minutes of partial (70%) liver 1 and 2 hours of global liver R; and 3) 60 minutes of partial (70%) liver I and 6 hours of global liver R. Groups 2 and 3 showed significant increases in plasma alanine and aspartate aminotransferase levels and in tissue malondialdehyde and myeloperoxidase contents. In the kidney, positive endothelial NOS (eNOS) staining was significantly decreased in group 3 compared with group 1. However, staining for inducible NOS (iNOS) and neuronal NOS (nNOS) did not differ among the groups. In the lung, the staining for eNOS and iNOS did not show significant differences among the groups; no positive nNOS staining was observed in any group. These results suggested that partial liver I followed by global liver R induced liver, kidney, and lung injuries characterized by neutrophil sequestration and increased oxidative stress. In addition, we supposed that the reduced NO formation via eNOS may be implicated in the moderate impairment of renal function, observed by others at 24 hours after liver I/R.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the role of arterial baroreceptors in arterial pressure (AP) and pulse interval (PI) regulation in conscious C57BL mice. Male animals, implanted with catheters in a femoral artery and a jugular vein, were submitted to sino-aortic (SAD), aortic (Ao-X) or carotid sinus denervation (Ca-X), 5 daysprior to the experiments. After basal recording of AP, the lack of reflex bradycardia elicited by administration of phenylephrine was used to confirm the efficacy of SAD, and cardiac autonomic blockade with methylatropine and propranolol was performed. The AP and PI variability were calculated in the time and frequency domains (spectral analysis/fast Fourier transform) with the spectra quantified in low-(LF; 0.25-1Hz) and high-frequency bands (HF; 1-5Hz). Basal AP and AP variability were higher after SAD, Ao-X or Ca-X than in intact mice. Pulse interval was similar among the groups, whereas PI variability was lower after SAD. Atropine elicited a slight tachycardia in control mice but did not change PI after total or partial denervation. The bradycardia caused by propranolol was higher after SAD, Ao-X or Ca-X compared with intact mice. The increase in the variability of AP was accompanied by a marked increase in the LF and HF power of the AP spectra after baroreceptor denervation. The LF and HF power of the PI were reduced by SAD and by Ao-X or Ca-X. Therefore, both sino-aortic and partial baroreceptor denervation in mice elicits hypertension and a remarkable increase in AP variability and cardiac sympathetic tonus. Spectral analysis showed an important contribution of the baroreflex in the power of LF oscillations of the PI spectra. Both sets of baroreceptors seem to be equally important in the autonomic regulation of the cardiovascular system in mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whenever the surgeon uses the stomach as an esophageal substitute, either one of two techniques is generally performed: total gastric transposition or gastric tube esophagoplasty. No existing reports compare the complications associated with these two surgical procedures. The purpose of this study is to review the authors` experience with total gastric transposition and verify whether this technique is superior to gastric tube esophagoplasty in children by comparing the main complications with those reported in the publications of gastric tubes esophagoplasties in the English language literature published in the last 38 years. A total of 35 children underwent total gastric transposition according to the classical technique. Most of these patients (27, or 77.1%) had long gap esophageal atresia. The most frequently observed complications were compared to those reported in nine studies of gastric tube esophagoplasty comprising 184 patients. Mortality and graft failure rates were also compared. Seven patients (20.0%) presented with leaks, all of which closed spontaneously. Six children were reoperated, three experienced gastric outlet obstruction secondary to axial torsion of the stomach placed in the retrosternal space and the other three experienced delayed gastric emptying that required revision of the piloroplasty. There were two deaths (5.7%) and no graft failure. Strictures were observed in five patients (14.2%) and all of these were resolved with endoscopic dilatations. Six patients had diarrhea that spontaneously resolved. In the late follow-up period, all patients were on full feed and thriving well. The comparisons with gastric tube patients demonstrated that the total gastric transposition group presented with significantly less leaks and strictures (P = 0.0001 and 0.001, respectively). The incidence of death and graft failure was not statistically different. In conclusion, gastric transposition is as a simple technical procedure for esophageal replacement in children with satisfactory results, and is superior to gastric tube esophagoplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of Aspergillus niveus with 30 mu g tunicamycin/ml did not interfere with alpha-glucosidase production, secretion, or its catalytic properties. Fully- and under-glycosylated forms of the enzyme had similar molecular masses, similar to 56 kDa. Moreover, the absence of N-glycans did not affect either pH optimum (6.0) or temperature optimum (65A degrees C). The K(m) and V(max) values of under- and fully-glycosylated forms of alpha-glucosidase were similar when assessed for hydrolysis of starch (similar to 0.6 mg/ml, similar to 350 mu mol glucose per min per ml), maltose (similar to 0.54 mu mol, similar to 330 mu mol glucose per min per ml) and p-nitrophenyl-alpha-d-glucopyranoside (similar to 0.54 mu mol, similar to 8.28 mu mol p-nitrophenol per min per ml). However, the under-glycosylated form was sensitive to high temperatures probably because, in addition to stabilizing the protein conformation, glycosylation may also prevent unfolded or partially folded proteins from aggregating. Binding assays clearly showed that the under-glycosylated protein did not bind to concanavalin A but has conserve its jacalin-binding property, suggesting that only O-glycans might be intact on the tunicamycin treated form of the enzyme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feline immunodeficiency virus (FIV) causes a slow progressive degeneration of the immune system which eventually leads to a disease comparable to acquired immune deficiency syndrome (AIDS) in humans. FIV has extensive sequence variation, a typical feature of lentiviruses. Sequence analysis showed that diversity was not evenly distributed throughout the genome, but was greatest in the envelope gene, env. The virus enters host cells via a sequential interaction, initiated by the envelope glycoprotein (env) binding the primary receptor molecule CD134 and followed by a subsequent interaction with chemokine co-receptor CXCR4. The purpose of this study was to isolate and characterize isolates of FIV from an open shelter in Sao Paulo, Brazil. The separated PBMC from 11 positive cats were co-cultured with MYA-1 cells. Full-length viral env glycoprotein genes were amplified and determined. Chimeric feline x human CD134 receptors were used to investigate the receptor utilization of 17 clones from Brazilian isolates of Fly. Analyses of the sequence present of molecular clones showed that all clones grouped within subtype B. In contrast to the virulent primary isolate FIV-GL8, expression of the first cysteine-rich domain (CRD1) of feline CD134 in the context of human CD134 was sufficient for optimal receptor function for all Brazilian FIV isolates tested. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Swallowed prostheses have been described in the literature, and in some cases, the diagnosis can be challenging, especially if the partial or complete denture is metal-free. This article presents a case of a swallowed partial denture and points to the importance of early diagnosis. A man was admitted to the emergency room complaining of progressive breathing difficulty while presenting with an extra volume in his neck. After inconclusive image examinations, endoscopy under sedation was used to identify and retrieve the foreign object, which was a metal-free acrylic partial denture. Early diagnosis and the correct treatment can avoid serious sequelae, such as edematous reactions, mucosal infection, and necrosis. Patients should be scheduled for regular recall visits for evaluation of prosthesis fit and retention, condition of the abutments, and nocturnal wear. Int J Prosthodont 2010;23:339-341.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.