950 resultados para CADMIUM TELLURIDE DETECTORS
Resumo:
This work is directed to the study and evaluation of gas diffusion electrodes as detectors in hydrogen sensors. Electrochemical experiments were carried out with rotating disk electrodes with a thin porous coating of the catalyst as a previous step to select useful parameters for the sensor. An experimental arrangement made in the laboratory that simulates the sensor was found appropriate to detect volumetric hydrogen percentages above 0.25% in mixtures H2:N2. The system shows a linear response for volumetric percentages of hydrogen between 0.25 and 2 %.
Resumo:
Stability constant (log beta) and thermodynamic parameters of Cd2+ complexes with sulfonamide and cephapirin were determined by Polarographic technique at pH = 7.30 ± 0.01 and µ = 1.0 M KNO3 at 250°C. The sulfonamides were sulfadiazine, sulfisoxazole, sulfamethaxazole, sulfamethazine, sulfathiazole, sulfacetamide and sulfanilamide used as primary ligands and cephapirin as secondary ligand. Cd2+ formed 1:1:1, 1:2:1 and 1:1:2 complexes. The nature of electrode processes were reversible and diffusion controlled. The stability constants and thermodynamic parameters (deltaG, deltaH and deltaS) were determined. The formation of the metal complexes has been found to be spontaneous, exothermic in nature, and entropically unfavourable at higher temperature.
Resumo:
Voltammetric technique was used to study the binary and ternary complexes of cadmium with L-amino acids and vitamin-C (L-ascorbic acid) at pH =7.30 ± 0.01, µ = 1.0M KNO3 at 25ºC and 35ºC. Cd (II) formed 1:1:1, 1:1:2 and 1:2:1 complexes with L-lysine, L-ornithine, L-threonine, L-serine, L-phenylglycine, L-phenylalanine, L-glutamic acid and L-aspartic acid used as primary ligands and L-ascorbic acid used as secondary ligand. The trend of stability constant of complexes was L-lysine < L-ornithine < L-threonine < L-serine < L-phenylglycine < L-phenylalanine < L-glutamic acid < L-aspartic acid which can be explained on the basis of size, basicity and steric hindrance of ligands. The values of stability constant (log β) varied from 2.23 to11.33 confirm that these drugs i.e. L-amino acids or in combination with L-ascorbic acid or their complexes could be used against Cd (II) toxicity. The study has been carried out at 35ºC also to determine the thermodynamic parameters such as enthalpy change (ΔH), Free energy change (ΔG) and entropy change (ΔS) respectively.
Resumo:
Local features are used in many computer vision tasks including visual object categorization, content-based image retrieval and object recognition to mention a few. Local features are points, blobs or regions in images that are extracted using a local feature detector. To make use of extracted local features the localized interest points are described using a local feature descriptor. A descriptor histogram vector is a compact representation of an image and can be used for searching and matching images in databases. In this thesis the performance of local feature detectors and descriptors is evaluated for object class detection task. Features are extracted from image samples belonging to several object classes. Matching features are then searched using random image pairs of a same class. The goal of this thesis is to find out what are the best detector and descriptor methods for such task in terms of detector repeatability and descriptor matching rate.
Resumo:
Planar, large area, position sensitive silicon detectors are widely utilized in high energy physics research and in medical, computed tomography (CT). This thesis describes author's research work relating to development of such detector components. The key motivation and objective for the research work has been the development of novel, position sensitive detectors improving the performance of the instruments they are intended for. Silicon strip detectors are the key components of barrel-shaped tracking instruments which are typically the innermost structures of high energy physics experimental stations. Particle colliders such as the former LEP collider or present LHC produce particle collisions and the silicon strip detector based trackers locate the trajectories of particles emanating from such collisions. Medical CT has become a regular part of everyday medical care in all developed countries. CT scanning enables x-ray imaging of all parts of the human body with an outstanding structural resolution and contrast. Brain, chest and abdomen slice images with a resolution of 0.5 mm are possible and latest CT machines are able to image whole human heart between heart beats. The two application areas are presented shortly and the radiation detection properties of planar silicon detectors are discussed. Fabrication methods and preamplifier electronics of the planar detectors are presented. Designs of the developed, large area silicon detectors are presented and measurement results of the key operating parameters are discussed. Static and dynamic performance of the developed silicon strip detectors are shown to be very satisfactory for experimental physics applications. Results relating to the developed, novel CT detector chips are found to be very promising for further development and all key performance goals are met.
Resumo:
The European Organization for Nuclear Research (CERN) operates the largest particle collider in the world. This particle collider is called the Large Hadron Collider (LHC) and it will undergo a maintenance break sometime in 2017 or 2018. During the break, the particle detectors, which operate around the particle collider, will be serviced and upgraded. Following the improvement in performance of the particle collider, the requirements for the detector electronics will be more demanding. In particular, the high amount of radiation during the operation of the particle collider sets requirements for the electronics that are uncommon in commercial electronics. Electronics that are built to function in the challenging environment of the collider have been designed at CERN. In order to meet the future challenges of data transmission, a GigaBit Transceiver data transmission module and an E-Link data bus have been developed. The next generation of readout electronics is designed to benefit from these technologies. However, the current readout electronics chips are not compatible with these technologies. As a result, in addition to new Gas Electron Multiplier (GEM) detectors and other technology, a new compatible chip is developed to function within the GEMs for the Compact Muon Solenoid (CMS) project. In this thesis, the objective was to study a data transmission interface that will be located on the readout chip between the E-Link bus and the control logic of the chip. The function of the module is to handle data transmission between the chip and the E-Link. In the study, a model of the interface was implemented with the Verilog hardware description language. This process was simulated by using chip design software by Cadence. State machines and operating principles with alternative possibilities for implementation are introduced in the E-Link interface design procedure. The functionality of the designed logic is demonstrated in simulation results, in which the implemented model is proven to be suitable for its task. Finally, suggestions that should be considered for improving the design have been presented.
Resumo:
Nowadays advanced simulation technologies of semiconductor devices occupies an important place in microelectronics production process. Simulation helps to understand devices internal processes physics, detect new effects and find directions for optimization. Computer calculation reduces manufacturing costs and time. Modern simulation suits such as Silcaco TCAD allow simulating not only individual semiconductor structures, but also these structures in the circuit. For that purpose TCAD include MixedMode tool. That tool can simulate circuits using compact circuit models including semiconductor structures with their physical models. In this work, MixedMode is used for simulating transient current technique setup, which include detector and supporting electrical circuit. This technique was developed by RD39 collaboration project for investigation radiation detectors radiation hard properties.
Resumo:
Regnellidium diphyllum has its distribution restricted to Southern Brazil and adjoining localities in Uruguay and Argentina. Currently it is on the list of threatened species of Rio Grande do Sul. The conversion of wetlands into agricultural areas or soil contamination by the introduction of waste products and fertilizers may compromise the establishment and survival of this species. Among the pollutants are heavy metals, such as cadmium (Cd). Megaspores were germinated in liquid culture medium, with concentrations 0 (control), 0.39; 0.78; 1.56; 3.12; 6.25; 12.5; 25; 50 and 100 mg L-1 of Cd, starting from a standard solution of Titrisol® at 1000 mg L-1. The increase of Cd in the growth medium to 50 mg L-1 resulted in low germinability (58%), and no germination was observed on 100 mg L-1. In apomictical sporophytes, the growth of primary root and leaf was significantly reduced and no secondary leaf was formed at Cd concentrations of 12.5 and higher than this. The results indicated that R. diphyllum is tolerant to the presence of Cd up to considerably higher concentrations (0.78 mg L-1) than that normally found in unpolluted aquatic ecosystems (0.01 mg L-1), although the sensitivity to higher concentrations might endanger the establishment and permanence of this species in habitats exposed to contamination with this metal.
Resumo:
We have previously demonstrated that acute third ventricle injections of both Pb2+ and Cd2+ impair the dipsogenic response elicited by three different situations: dehydration and central cholinergic or angiotensinergic stimulation. ß-Adrenergic activation is part of the multifactorial integrated systems operating in drinking behavior control in the central nervous system. In the present study acute third ventricle injections of Pb2+ (3, 30 and 300 pmol/rat) or Cd2+ (0.3, 3 and 30 pmol/rat) blocked the dipsogenic response induced by third ventricle injections of isoproterenol (ISO; 160 nmol/rat) in a dose-dependent manner. Normohydrated animals receiving ISO + NaAc (sodium acetate) or saline (controls) displayed a high water intake after 120 min (ISO + saline = 5.78 ± 0.54 ml/100 g; ISO + NaAc = 6.00 ± 0.6 ml/100 g). After the same period, animals receiving ISO but pretreated with PbAc at the highest dose employed (300 pmol/rat) drank 0.78 ± 0.23 ml/100 g while those receiving ISO and pretreated with the highest dose of CdCl2 (30 pmol/rat) presented a water intake of 0.7 ± 0.30 ml/100 g. Third ventricle injections of CdCl2 (3 nmol/rat) or PbAc (3 nmol/rat) did not modify food intake in rats deprived of food for 24 h. Thus, general central nervous system depression explaining the antidipsogenic action of the metals can be safely excluded. It is concluded that both Pb2+ and Cd2+ inhibit water intake induced by central ß-adrenergic stimulation
Resumo:
We have previously demonstrated that acute third ventricle injections of both lead and cadmium prevent the dipsogenic response elicited by dehydration or by central injections of dipsogenic agents such as angiotensin II, carbachol and isoproterenol in rats. We have also shown that the antidipsogenic action of cadmium may be due, at least in part, to activation of thirst-inhibitory central serotonergic pathways. In the present paper we show that in Wistar male rats the antidipsogenic effect of both lead acetate (3.0 nmol/rat) and cadmium chloride (3.0 nmol/rat) may be partially dependent on the activation of brain opiatergic pathways since central injections of naloxone (82.5 nmol/rat), a non-selective opioid antagonist, blunt the thirst-inhibiting effect of these metals. One hundred and twenty minutes after the second third ventricle injections, dehydrated animals (14 h overnight) receiving saline + sodium acetate displayed a high water intake (7.90 ± 0.47 ml/100 g body weight) whereas animals receiving saline + lead acetate drank 3.24 ± 0.47 ml/100 g body weight. Animals receiving naloxone + lead acetate drank 6.94 ± 0.60 ml/100 g body weight. Animals receiving saline + saline drank 8.16 ± 0.66 ml/100 g body weight whilst animals receiving saline + cadmium chloride drank 1.63 ± 0.37 ml/100 g body weight. Animals receiving naloxone + cadmium chloride drank 8.01 ± 0.94 ml/100 g body weight. It is suggested that acute third ventricle injections of both lead and cadmium exert their antidipsogenic effect by activating thirst-inhibiting opioid pathways in the brain.
Resumo:
Whole body oxygen consumption and some hemolymph parameters such as pH, partial pressure of gases, level of ions and lactate were measured in the estuarine crab Chasmagnathus granulata after both acute (96 h) and chronic (2 weeks) exposure to cadmium at concentrations ranging from 0.4 to 6.3 mg/l. In all instances, the crabs developed hemolymph acidosis, but no respiratory (increased PCO2) or lactate increases were evident. Hemolymph levels of sodium and calcium were always increased by cadmium exposure. The chronic toxicity of cadmium was enhanced at 12 salinity, even causing a significantly higher mortality in comparison with the higher salinity (30) used. A general metabolic arrest took place at 12 salinity in the crabs chronically exposed to cadmium, as indicated by decreases of oxygen consumption and PCO2, an increase of PO2, along with no changes in lactate levels. These imbalances were associated with severe necrosis and telangiectasia in the respiratory gills, probably leading to respiratory impairment and finally histotoxic hypoxia and death of the animals.
Resumo:
The elements called heavy metals when ingested are not completely eliminated from animal bodies and are responsible for chronic and acute intoxications. Sixty-three samples of beer, produced in the states of São Paulo, Paraná, Rio de Janeiro, Rio Grande do Sul, Minas Gerais, and Pará, were analysed for lead and cadmium content by atomic absorption spectrometry with graphite furnace atomization and Zeeman correction. The concentrations of Pb and Cd of dark differed significantly from light beers, being higher in the former. No significant difference was found between the beers produced in predominantly rural areas and the ones produced in industrialized areas. The concentrations of lead and cadmium in all samples were bellow the maximum accepted by present Brazilian regulations and ranged from not detected to 290mugPb/L and from not detected to 14.3mugCd/L. The average concentrations were 37mugPb/L and 1.6mugCd/L.
Resumo:
The aim of this study was to evaluate the effects of pH, dextrose and yeast extract on the cadmium toxicity on Saccharomyces cerevisiae PE-2. In the first assay, the YED mediums with different pH (2, 3, 4, 5, 6, 7, and 8) containing 0.0 and 0.05 mmol Cd L-1 were inoculated with yeast suspension and incubated at 30 °C for 18 hours. During the anaerobic growth, the biomass concentration was determined. The yeast trehalose content, cell viability, and the growth rate were assessed at the beginning and at the end of the growth stages. In the second assay the YED mediums were diluted to the total, ½, and ¼ content of dextrose and yeast and 0.0 and 0.05 mmol Cd L-1 were added. The pH of the mediums was adjusted to 5. The culture mediums were inoculated and incubated at 30 °C for 18 hours. The yeast growth was not affected by cadmium at high pH, but at low pH the yeast becomes more sensitive to the toxic effect. The yeast susceptibility to cadmium was enhanced by the decrease of yeast extract strength and the increase of dextrose strength.
Resumo:
Pisciculture is an economic activity that is steadily growing in the state of Parana, Brazil, and Nile tilapia (Oreochromis niloticus) is one of the widely cultivated species in this state. Tilapia is not only a very nutritious food, but also an important indicator of environmental contamination. This study aimed to verify contamination by cadmium, copper and lead in tilapia fillets, and to compare the found values to international legislations. Were collected 135 samples of tilapia fillets, between July 2006 and May 2007, in three fish stores located in regions west and north of Paraná State. Samples of tilapia fillet were analyzed in relation to the presence of cadmiun, lead and copper, using atomic absorption spectrophotometry. Lead has not been detected in the analyses. Cadmium has been detected in three samples, on concentrations of 0.012 µg.g-1, 0.011 µg.g-1 and 0.014 µg.g-1. Copper has been detected in all fillets, and the average concentration of each cold storage plant was of 0.122 µg.g-1, 0.106 µg.g-1 and 0.153 µg.g-1. The concentrations found in this study are within the limits allowed by both the European and the Australian legislations.
Resumo:
Many studies have drawn attention to the occurrence and concentration of toxic elements found in the fruiting body of mushrooms. Some edible mushroom species are known to accumulate high levels of inorganic contaminants, mainly cadmium, mercury, and lead. There are about 2,000 known edible mushroom species, but only 25 of them are cultivated and used as food. In Brazil, the most marketed and consumed mushroom species are Agaricus bisporus, known as Paris champignon, Lentinus edodes, or Shitake and Pleurotus sp, also called Shimeji or Hiratake. In this study, the concentration of cadmium was determined in Lentinus edodes mushrooms from different cities in São Paulo state and some samples imported from Japan and China. The analyses were performed by graphite furnace atomic absorption spectrometry after HNO3-H2O2 digestion. The results showed a lower concentration of Cd in the mushrooms cultivated in São Paulo (0.0079 to 0.023 mg.kg-1 in natura) than that of the mushrooms cultivated abroad (0.125 to 0.212 mg.kg-1 in natura). Although there is no tolerance limit for Cd in mushrooms in Brazil, the results show that Lentinus edodes mushrooms can be safely consumed.