962 resultados para Blood Gas Monitoring, Transcutaneous
Resumo:
OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.
Resumo:
OBJECTIVE: Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS: We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mannheim, Germany) in lean (n=15) and obese (n=11) patients. RESULTS: No difference was found in diastolic BP between the two groups, nor between the arm and the wrist. Systolic BP measured at the arm was, however, significantly lower in obese (99+/-9 mmHg, mean+/-SD) than in lean (107+/-14 mmHg; P<0.001) patients, whereas systolic BP determined at the wrist averaged 106 mmHg in both groups. CONCLUSION: The use of validated wrist BP measuring devices appears therefore particularly appealing in obese individuals with a large arm circumference
Resumo:
Self-measurement of blood pressure (SMBP) is increasingly used to assess blood pressure outside the medical setting. A prerequisite for the wide use of SMBP is the availability of validated devices providing reliable readings when they are handled by patients. This is the case today with a number of fully automated oscillometric apparatuses. A major advantage of SMBP is the great number of readings, which is linked with high reproducibility. Given these advantages, one of the major indications for SMBP is the need for evaluation of antihypertensive treatment, either for individual patients in everyday practice or in clinical trials intended to characterize the effects of blood-pressure-lowering medications. In fact, SMBP is particularly helpful for evaluating resistant hypertension and detecting white-coat effect in patients exhibiting high office blood pressure under antihypertensive therapy. SMBP might also motivate the patient and improve his or her adherence to long-term treatment. Moreover, SMBP can be used as a sensitive technique for evaluating the effect of antihypertensive drugs in clinical trials; it increases the power of comparative trials, allowing one to study fewer patients or to detect smaller differences in blood pressure than would be possible with the office measurement. Therefore, SMBP can be regarded as a valuable technique for the follow-up of treated patients as well as for the assessment of antihypertensive drugs in clinical trials.
Resumo:
Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values <0.040). Similar inverse associations were observed for paraxanthine and theophylline. Adjusted night-time systolic blood pressure in the first (lowest), second, third, and fourth (highest) quartile of paraxanthine urinary excretions were 110.3, 107.3, 107.3, and 105.1 mm Hg, respectively (P trend <0.05). No associations of urinary excretions with diastolic blood pressure were generally found, and theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure.
Resumo:
Do we need country-specific blood pressure reference values for children? This question will sound weird for clinicians caring for adult hypertensive patients or researchers working in the domain of adult hypertension. Indeed, there are no country-specific reference values for adults. This contrasts with hypertension in children, for whom there is an increasing number of published sets of country-specific reference values [1-5].
Resumo:
OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.
Resumo:
Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined. OBJECTIVE: To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods. PATIENTS AND METHOD: ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband(®)) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.-10p.m.) and nighttime (10p.m.-7a.m.) periods. RESULTS: Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period. CONCLUSION: Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.
Resumo:
Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.
Resumo:
Short-term exposure to ambient particulate matter with aerodynamic diameters<10 µm were found to be positively associated with blood pressure. Yet, little information exists regarding the association between particles and circadian rhythm of blood pressure. Hence, we analyzed the association of exposure to particulate matter with aerodynamic diameters<10 µm on the day of examination and ≤7 days before with ambulatory blood pressure and with sodium excretion in 359 adults from the general population using multiple linear regression. After controlling for potential confounders, a 10-µg/m3 increase in particulate matter with aerodynamic diameters<10 µm levels was associated with nighttime systolic blood pressure (β=1.32 mm Hg 95% CI, 0.06-2.58 mm Hg at lag 0; P=0.04), nighttime diastolic blood pressure (0.72 mm Hg 95% CI, 0.03-1.42 mm Hg at lag 2; P=0.04), nocturnal systolic blood pressure dipping (-0.96 mm Hg 95% CI, -1.89 to -0.03 mm Hg at lag 0; P=0.044), and daytime urinary sodium excretion (-0.05 log-mmol/min 95% CI, -0.10 to -0.01 log-mmol/min at lag 0; P=0.027) but not with nighttime sodium excretion. The associations with blood pressure rapidly diminished with increasing lag days, and the associations with daytime sodium excretion were maximal with particulate matter with aerodynamic diameters<10 µm in exposures 2 to 5 days before. The associations of short-term increases in particulate matter with aerodynamic diameters<10 µm with higher nighttime blood pressure and blunted systolic blood pressure dipping were preceded by associations with reduced ability of the kidney to excrete sodium during daytime. The underlying mechanism linking air pollution to increased cardiovascular risk may include disturbed circadian rhythms of renal sodium handling and blood pressure.
Resumo:
ABSTRACT: Clinical and complementary analysis are good alternatives to evaluate physiological demand in performance horses. The aim of this study was to assess whether the physical effort variation of the three-day Vaquejada competition (a Brazilian form of bullfighting) reflected in clinical and blood gasometric changes. During the competition eight sprints have been performed on the first day (D1), eight on the second (D2) and three on the last one (D3). Ten horses were evaluated by checking heart and respiratory rates and collecting blood samples for use in portable chemistry analyzer. Through that, it was assessed potential of hydrogen ion (pH), carbon dioxide pressure (pCO2), bicarbonate (HCO3-) and titratable base concentration (cBase). Evaluations were carried with resting of at least twenty hours, before physical activity (D0), as control parameter, and up to thirty minutes after each sprint. Clinical parameters have increased on D1, D2 and D3, when compared to D0, which demonstrated the increased demand for substrate and oxygen to the cells.. Blood gasometric trial showed reductions of all variables, most marked between D1 and D2. It was verified less alteration of all clinical and blood gasometric parameters in D3 against D0. We concluded that the change effort between days of competition influenced the clinical and blood gas parameters, demonstrating appropriate physiological response. The data were presented as mean and standard error of the mean (mean ± SEM) obtained in different days. Normality was confirmed by the Kolmogorov-Sminov test and data were compared by one-way ANOVA, followed by post-test Holm-Sidak (GraphPad Prism 2.6 for Windows, GraphPad Software, San Diego, CA, USA). P≤0.05 was considered as statistically significant.
Resumo:
Metabolic acidosis has profound effects on vascular tone. This study investigated the in vivo effects of acute metabolic acidosis (AMA) and chronic metabolic acidosis (CMA) on hemodynamic parameters and endothelial function. CMA was induced by ad libitum intake of 1% NH4Cl for 7 days, and AMA was induced by a 3-h infusion of 6 M NH4Cl (1 mL/kg, diluted 1:10). Phenylephrine (Phe) and acetylcholine (Ach) dose-response curves were performed by venous infusion with simultaneous venous and arterial blood pressure monitoring. Plasma nitrite/nitrate (NOx) was measured by chemiluminescence. The CMA group had a blood pH of 7.15±0.03, which was associated with reduced bicarbonate (13.8±0.98 mmol/L) and no change in the partial pressure of arterial carbon dioxide (PaCO2). The AMA group had a pH of 7.20±0.01, which was associated with decreases in bicarbonate (10.8±0.54 mmol/L) and PaCO2 (47.8±2.54 to 23.2±0.74 mmHg) and accompanied by hyperventilation. Phe or ACh infusion did not affect arterial or venous blood pressure in the CMA group. However, the ACh infusion decreased the arterial blood pressure (ΔBP: -28.0±2.35 mm Hg [AMA] to -4.5±2.89 mmHg [control]) in the AMA group. Plasma NOx was normal after CMA but increased after AMA (25.3±0.88 to 31.3±0.54 μM). These results indicate that AMA, but not CMA, potentiated the Ach-induced decrease in blood pressure and led to an increase in plasma NOx, reinforcing the effect of pH imbalance on vascular tone and blood pressure control.
Resumo:
La ventilation unipulmonaire (SLV; Single Lung Ventilation) pendant les chirurgies thoraciques entraîne des altérations cardio-pulmonaires et hémodynamiques importantes. L’objectif de ce projet de recherche consiste à étudier l’impact de la SLV sur l’oxymétrie cérébrale et sa relation avec les complications post opératoires. La première étude inclut vingt patients ayant subi une chirurgie thoracique nécessitant une SLV. L’oxymétrie a été mesurée à l’aide de l’oxymètre cérébral absolu FORESIGHTTM (CASMED, USA) afin d’étudier les changements de la saturation cérébrale absolue (SctO2) tout le long de la chirurgie. La SctO2 ainsi que les paramètres de monitorage standard (BIS, SpO2, pression sanguine, fréquence cardiaque) ont été notés à toutes les cinq minutes à partir de l’induction jusqu’au réveil. Une analyse sanguine (paO2, paCO2, Hb) a été effectuée à toutes les quinze minutes. La deuxième étude effectuée consistait d’étudier la relation entre la désaturation cérébrale en oxygène et les complications post opératoires. Pour cette fin, les scores Clavien et SOFA mesurant l’amplitude des complications, ont été établis pour chaque patient. Les données sont présentées sous forme de moyenne et de la médiane [1er quartile, 3ème quartile; min – max]. Les vingt patients de la première étude ont montré une valeur moyenne absolue de saturation cérébrale absolue (SctO2) de 80% avant l’induction. Durant la SLV, cette valeur a chuté jusqu’à 63% et est remontée à 71% directement après extubation. Tous ces patients ont subi une désaturation durant SLV de plus que 15% comparativement à la valeur de base et 70% ont eu une désaturation de plus de 20%. La désaturation n’a pas été corrélée avec aucun des paramètres de monitorage clinique standard comme la pression artérielle, les analyses des gaz artériels, la saturation périphérique ou la PaO2. La deuxième étude incluant trente autres patients aux vingt premiers, est venue confirmer les résultats de la première étude. De plus, une analyse de corrélation entre les valeurs minimales de SctO2 obtenues durant SLV et les complications post opératoires a été effectuée. Les patients avaient une SctO2 de base de 80%, qui a chuté jusqu’à 64% pendant la SLV pour récupérer à 71% avant la fin de la chirurgie. 82% des patients ont subi des désaturations de plus de 15% des valeurs initiales et 10% ont atteint des valeurs de SctO2 entre 45 et 55%. Les valeurs minimales de SctO2 observées durant la SLV corrélaient avec le score SOFA non respiratoire (R2=0,090, p=0,0287) ainsi qu’avec le score Clavien (R2=0,098, p=0,0201), mais ne corrélait avec aucun des paramètres cliniques standards (ex : SpO¬2, PaO2, PaCO2, Hb). En définissant une valeur seuil de SctO2=65%, le «Odds ratio» d’avoir une défaillance d’organe non respiratoire est de 2.37 (IC 95%=1,18 – 4,39, p=0,043) et d’avoir une complication classifiée supérieure à un score Clavien de 0 est de 3,19 (IC 95%=1,6 – 6,34, p=0,0272). Les chirurgies thoraciques avec une SLV sont associées à des chutes significatives de SctO2, et les valeurs minimales de SctO2 semblent avoir une corrélation positive avec les complications post opératoires.
Resumo:
Introducción. En Colombia, el 80% de los pacientes con enfermedad renal crónica en hemodiálisis tienen fístula arteriovenosa periférica (FAV) que asegura el flujo de sangre durante la hemodiálisis (1), la variabilidad en el flujo de sangre en el brazo de la FAV hacia la parte distal, puede afectar la lectura de la oximetría de pulso (SpO2) (2), llevando a la toma de decisiones equivocadas por el personal de salud. El objetivo de este estudio es aclarar si existe diferencia entre la SpO2 del brazo de la FAV y el brazo contralateral. Materiales y métodos. Se realizó un estudio de correlación entre los valores de SpO2 del brazo con FAV contra el brazo sin FAV, de 40 pacientes que asistieron a hemodiálisis. La recolección de los datos se llevó a cabo, con un formato que incluyó el resultado de la pulsioximetria y variables asociadas, antes, durante y después de la hemodiálisis. Se comparó la mediana de los deltas de las diferencias con pruebas estadísticas T Student – Mann Whitney, aceptando un valor significativo de p < 0,05. Resultados. No se encontraron diferencias estadísticamente significativas de la SpO2 entre el brazo con FAV y el brazo sin FAV, antes, durante y después de la diálisis, sin embargo si se apreció una correlación positiva estadísticamente significativa. Conclusiones. Se encontró correlación positiva estadísticamente significativa, donde no hubo diferencias en el resultado la pulsioximetría entre el brazo con FAV y brazo sin FAV, por lo tanto es válido tomar la pulsioximetría en cualquiera de los brazos.