916 resultados para Biomedical Image Processing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reconstruction of the cell lineage tree of early zebrafish embryogenesis requires the use of in-vivo microscopy imaging and image processing strategies. Second (SHG) and third harmonic generation (THG) microscopy observations in unstained zebrafish embryos allows to detect cell divisions and cell membranes from 1-cell to 1K-cell stage. In this article, we present an ad-hoc image processing pipeline for cell tracking and cell membranes segmentation enabling the reconstruction of the early zebrafish cell lineage tree until the 1K-cell stage. This methodology has been used to obtain digital zebrafish embryos allowing to generate a quantitative description of early zebrafish embryogenesis with minute temporal accuracy and μm spatial resolution

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hoy en día las técnicas de adquisición de imágenes tridimensionales son comunes en diversas áreas, pero cabe destacar la relevancia que han adquirido en el ámbito de la imagen biomédica, dentro del cual encontramos una amplia gama de técnicas como la microscopía confocal, microscopía de dos fotones, microscopía de fluorescencia mediante lámina de luz, resonancia magnética nuclear, tomografía por emisión de positrones, tomografía de coherencia óptica, ecografía 3D y un largo etcétera. Un denominador común de todas esas aplicaciones es la constante necesidad por aumentar la resolución y la calidad de las imágenes adquiridas. En algunas de dichas técnicas de imagen tridimensional se da una interesante situación: aunque que cada volumen adquirido no contiene información suficiente para representar el objeto bajo estudio dentro de los parámetros de calidad requeridos por algunas aplicaciones finales, el esquema de adquisición permite la obtención de varios volúmenes que representan diferentes vistas de dicho objeto, de tal forma que cada una de las vistas proporciona información complementaria acerca del mismo. En este tipo de situación es posible, mediante la combinación de varias de esas vistas, obtener una mejor comprensión del objeto que a partir de cada una de ellas por separado. En el contexto de esta Tesis Doctoral se ha propuesto, desarrollado y validado una nueva metodología de proceso de imágenes basada en la transformada wavelet disc¬reta para la combinación, o fusión, de varias vistas con información complementaria de un mismo objeto. El método de fusión propuesto aprovecha la capacidad de descom¬posición en escalas y orientaciones de la transformada wavelet discreta para integrar en un solo volumen toda la información distribuida entre el conjunto de vistas adquiridas. El trabajo se centra en dos modalidades diferentes de imagen biomédica que per¬miten obtener tales adquisiciones multi-vista. La primera es una variante de la micro¬scopía de fluorescencia, la microscopía de fluorescencia mediante lámina de luz, que se utiliza para el estudio del desarrollo temprano de embriones vivos en diferentes modelos animales, como el pez cebra o el erizo de mar. La segunda modalidad es la resonancia magnética nuclear con realce tardío, que constituye una valiosa herramienta para evaluar la viabilidad del tejido miocárdico en pacientes con diversas miocardiopatías. Como parte de este trabajo, el método propuesto ha sido aplicado y validado en am¬bas modalidades de imagen. En el caso de la aplicación a microscopía de fluorescencia, los resultados de la fusión muestran un mejor contraste y nivel de detalle en comparación con cualquiera de las vistas individuales y el método no requiere de conocimiento previo acerca la función de dispersión puntual del sistema de imagen. Además, los resultados se han comparado con otros métodos existentes. Con respecto a la aplicación a imagen de resonancia magnética con realce tardío, los volúmenes fusionados resultantes pre-sentan una mejora cuantitativa en la nitidez de las estructuras relevantes y permiten una interpretación más sencilla y completa de la compleja estructura tridimensional del tejido miocárdico en pacientes con cardiopatía isquémica. Para ambas aplicaciones los resultados de esta tesis se encuentran actualmente en uso en los centros clínicos y de investigación con los que el autor ha colaborado durante este trabajo. Además se ha puesto a libre disposición de la comunidad científica la implementación del método de fusión propuesto. Por último, se ha tramitado también una solicitud de patente internacional que cubre el método de visualización desarrollado para la aplicación de Resonancia Magnética Nuclear. Abstract Nowadays three dimensional imaging techniques are common in several fields, but es-pecially in biomedical imaging, where we can find a wide range of techniques including: Laser Scanning Confocal Microscopy, Laser Scanning Two Photon Microscopy, Light Sheet Fluorescence Microscopy, Magnetic Resonance Imaging, Positron Emission To-mography, Optical Coherence Tomography, 3D Ultrasound Imaging, etc. A common denominator of all those applications being the constant need for further increasing resolution and quality of the acquired images. Interestingly, in some of the mentioned three-dimensional imaging techniques a remarkable situation arises: while a single volume does not contain enough information to represent the object being imaged within the quality parameters required by the final application, the acquisition scheme allows recording several volumes which represent different views of a given object, with each of the views providing complementary information. In this kind of situation one can get a better understanding of the object by combining several views instead of looking at each of them separately. Within such context, in this PhD Thesis we propose, develop and test new image processing methodologies based on the discrete wavelet transform for the combination, or fusion, of several views containing complementary information of a given object. The proposed fusion method exploits the scale and orientation decomposition capabil¬ities of the discrete wavelet transform to integrate in a single volume all the available information distributed among the set of acquired views. The work focuses in two different biomedical imaging modalities which provide such multi-view datasets. The first one is a particular fluorescence microscopy technique, Light-Sheet Fluorescence Microscopy, used for imaging and gaining understanding of the early development of live embryos from different animal models (like zebrafish or sea urchin). The second is Delayed Enhancement Magnetic Resonance Imaging, which is a valuable tool for assessing the viability of myocardial tissue on patients suffering from different cardiomyopathies. As part of this work, the proposed method was implemented and then validated on both imaging modalities. For the fluorescence microscopy application, the fusion results show improved contrast and detail discrimination when compared to any of the individual views and the method does not rely on prior knowledge of the system’s point spread function (PSF). Moreover, the results have shown improved performance with respect to previous PSF independent methods. With respect to its application to Delayed Enhancement Magnetic Resonance Imaging, the resulting fused volumes show a quantitative sharpness improvement and enable an easier and more complete interpretation of complex three-dimensional scar and heterogeneous tissue information in ischemic cardiomyopathy patients. In both applications, the results of this thesis are currently in use in the clinical and research centers with which the author collaborated during his work. An imple¬mentation of the fusion method has also been made freely available to the scientific community. Finally, an international patent application has been filed covering the visualization method developed for the Magnetic Resonance Imaging application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose to directly process 3D + t image sequences with mathematical morphology operators, using a new classi?cation of the 3D+t structuring elements. Several methods (?ltering, tracking, segmentation) dedicated to the analysis of 3D + t datasets of zebra?sh embryogenesis are introduced and validated through a synthetic dataset. Then, we illustrate the application of these methods to the analysis of datasets of zebra?sh early development acquired with various microscopy techniques. This processing paradigm produces spatio-temporal coherent results as it bene?ts from the intrinsic redundancy of the temporal dimension, and minimizes the needs for human intervention in semi-automatic algorithms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel algorithm for performing registration of dynamic contrast-enhanced (DCE) MRI data of the breast is presented. It is based on an algorithm known as iterated dynamic programming originally devised to solve the stereo matching problem. Using artificially distorted DCE-MRI breast images it is shown that the proposed algorithm is able to correct for movement and distortions over a larger range than is likely to occur during routine clinical examination. In addition, using a clinical DCE-MRI data set with an expertly labeled suspicious region, it is shown that the proposed algorithm significantly reduces the variability of the enhancement curves at the pixel level yielding more pronounced uptake and washout phases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ACM Computing Classification System (1998): I.7, I.7.5.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary goal of this dissertation is to develop point-based rigid and non-rigid image registration methods that have better accuracy than existing methods. We first present point-based PoIRe, which provides the framework for point-based global rigid registrations. It allows a choice of different search strategies including (a) branch-and-bound, (b) probabilistic hill-climbing, and (c) a novel hybrid method that takes advantage of the best characteristics of the other two methods. We use a robust similarity measure that is insensitive to noise, which is often introduced during feature extraction. We show the robustness of PoIRe using it to register images obtained with an electronic portal imaging device (EPID), which have large amounts of scatter and low contrast. To evaluate PoIRe we used (a) simulated images and (b) images with fiducial markers; PoIRe was extensively tested with 2D EPID images and images generated by 3D Computer Tomography (CT) and Magnetic Resonance (MR) images. PoIRe was also evaluated using benchmark data sets from the blind retrospective evaluation project (RIRE). We show that PoIRe is better than existing methods such as Iterative Closest Point (ICP) and methods based on mutual information. We also present a novel point-based local non-rigid shape registration algorithm. We extend the robust similarity measure used in PoIRe to non-rigid registrations adapting it to a free form deformation (FFD) model and making it robust to local minima, which is a drawback common to existing non-rigid point-based methods. For non-rigid registrations we show that it performs better than existing methods and that is less sensitive to starting conditions. We test our non-rigid registration method using available benchmark data sets for shape registration. Finally, we also explore the extraction of features invariant to changes in perspective and illumination, and explore how they can help improve the accuracy of multi-modal registration. For multimodal registration of EPID-DRR images we present a method based on a local descriptor defined by a vector of complex responses to a circular Gabor filter.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work discusses the determination of the breathing patterns in time sequence of images obtained from magnetic resonance (MR) and their use in the temporal registration of coronal and sagittal images. The registration is made without the use of any triggering information and any special gas to enhance the contrast. The temporal sequences of images are acquired in free breathing. The real movement of the lung has never been seen directly, as it is totally dependent on its surrounding muscles and collapses without them. The visualization of the lung in motion is an actual topic of research in medicine. The lung movement is not periodic and it is susceptible to variations in the degree of respiration. Compared to computerized tomography (CT), MR imaging involves longer acquisition times and it is preferable because it does not involve radiation. As coronal and sagittal sequences of images are orthogonal to each other, their intersection corresponds to a segment in the three-dimensional space. The registration is based on the analysis of this intersection segment. A time sequence of this intersection segment can be stacked, defining a two-dimension spatio-temporal (2DST) image. The algorithm proposed in this work can detect asynchronous movements of the internal lung structures and lung surrounding organs. It is assumed that the diaphragmatic movement is the principal movement and all the lung structures move almost synchronously. The synchronization is performed through a pattern named respiratory function. This pattern is obtained by processing a 2DST image. An interval Hough transform algorithm searches for synchronized movements with the respiratory function. A greedy active contour algorithm adjusts small discrepancies originated by asynchronous movements in the respiratory patterns. The output is a set of respiratory patterns. Finally, the composition of coronal and sagittal image pairs that are in the same breathing phase is realized by comparing of respiratory patterns originated from diaphragmatic and upper boundary surfaces. When available, the respiratory patterns associated to lung internal structures are also used. The results of the proposed method are compared with the pixel-by-pixel comparison method. The proposed method increases the number of registered pairs representing composed images and allows an easy check of the breathing phase. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a novel algorithm to successfully achieve viable integrity and authenticity addition and verification of n-frame DICOM medical images using cryptographic mechanisms. The aim of this work is the enhancement of DICOM security measures, especially for multiframe images. Current approaches have limitations that should be properly addressed for improved security. The algorithm proposed in this work uses data encryption to provide integrity and authenticity, along with digital signature. Relevant header data and digital signature are used as inputs to cipher the image. Therefore, one can only retrieve the original data if and only if the images and the inputs are correct. The encryption process itself is a cascading scheme, where a frame is ciphered with data related to the previous frames, generating also additional data on image integrity and authenticity. Decryption is similar to encryption, featuring also the standard security verification of the image. The implementation was done in JAVA, and a performance evaluation was carried out comparing the speed of the algorithm with other existing approaches. The evaluation showed a good performance of the algorithm, which is an encouraging result to use it in a real environment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An efficient representation method for arbitrarily shaped image segments is proposed. This method includes a smart way to select wavelet basis to approximate the given image segment, with improved image quality and reduced computational load.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Three-dimensional (3D) synthetic aperture radar (SAR) imaging via multiple-pass processing is an extension of interferometric SAR imaging. It exploits more than two flight passes to achieve a desired resolution in elevation. In this paper, a novel approach is developed to reconstruct a 3D space-borne SAR image with multiple-pass processing. It involves image registration, phase correction and elevational imaging. An image model matching is developed for multiple image registration, an eigenvector method is proposed for the phase correction and the elevational imaging is conducted using a Fourier transform or a super-resolution method for enhancement of elevational resolution. 3D SAR images are obtained by processing simulated data and real data from the first European Remote Sensing satellite (ERS-1) with the proposed approaches.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pectus carinatum (PC) is a chest deformity caused by a disproportionate growth of the costal cartilages compared to the bony thoracic skeleton, pulling the sternum towards, which leads to its protrusion. There has been a growing interest on using the ‘reversed Nuss’ technique as minimally invasive procedure for PC surgical correction. A corrective bar is introduced between the skin and the thoracic cage and positioned on top of the sternum highest protrusion area for continuous pressure. Then, it is fixed to the ribs and kept implanted for about 2–3 years. The purpose of this work was to (a) assess the stresses distribution on the thoracic cage that arise from the procedure, and (b) investigate the impact of different positioning of the corrective bar along the sternum. The higher stresses were generated on the 4th, 5th and 6th ribs backend, supporting the hypothesis of pectus deformities correction-induced scoliosis. The different bar positioning originated different stresses on the ribs’ backend. The bar position that led to lower stresses generated on the ribs backend was the one that also led to the smallest sternum displacement. However, this may be preferred, as the risk of induced scoliosis is lowered.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fluorescent protein microscopy imaging is nowadays one of the most important tools in biomedical research. However, the resulting images present a low signal to noise ratio and a time intensity decay due to the photobleaching effect. This phenomenon is a consequence of the decreasing on the radiation emission efficiency of the tagging protein. This occurs because the fluorophore permanently loses its ability to fluoresce, due to photochemical reactions induced by the incident light. The Poisson multiplicative noise that corrupts these images, in addition with its quality degradation due to photobleaching, make long time biological observation processes very difficult. In this paper a denoising algorithm for Poisson data, where the photobleaching effect is explicitly taken into account, is described. The algorithm is designed in a Bayesian framework where the data fidelity term models the Poisson noise generation process as well as the exponential intensity decay caused by the photobleaching. The prior term is conceived with Gibbs priors and log-Euclidean potential functions, suitable to cope with the positivity constrained nature of the parameters to be estimated. Monte Carlo tests with synthetic data are presented to characterize the performance of the algorithm. One example with real data is included to illustrate its application.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Once in a digital form, a radiographic image may be processed in several ways in order to turn the visualization an act of improved diagnostic value. Practitioners should be aware that, depending on each clinical context, digital image processing techniques are available to help to unveil visual information that is, in fact, carried by the bare digital radiograph and may be otherwise neglected. The range of visual enhancement procedures includes simple techniques that deal with the usual brightness and contrast manipulation up to much more elaborate multi-scale processing that provides customized control over the emphasis given to the relevant finer anatomical details. This chapter is intended to give the reader a practical understanding of image enhancement techniques that might be helpful to improve the visual quality of the digital radiographs and thus to contribute to a more reliable and assertive reporting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Measurements in civil engineering load tests usually require considerable time and complex procedures. Therefore, measurements are usually constrained by the number of sensors resulting in a restricted monitored area. Image processing analysis is an alternative way that enables the measurement of the complete area of interest with a simple and effective setup. In this article photo sequences taken during load displacement tests were captured by a digital camera and processed with image correlation algorithms. Three different image processing algorithms were used with real images taken from tests using specimens of PVC and Plexiglas. The data obtained from the image processing algorithms were also compared with the data from physical sensors. A complete displacement and strain map were obtained. Results show that the accuracy of the measurements obtained by photogrammetry is equivalent to that from the physical sensors but with much less equipment and fewer setup requirements. © 2015Computer-Aided Civil and Infrastructure Engineering.