993 resultados para Bauru Aquifer System


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In October 1979, a period of heavy rainfall along the French Riviera was followed by the collapse of the Ligurian continental slope adjacent to the airport of Nice, France. A body of slope sediments, which was shortly beforehand affected by construction work south of the airport, was mobilized and traveled hundreds of kilometers downslope into the Var submarine canyon and, eventually, into the deep Ligurian basin. As a direct consequence, the construction was destroyed, seafloor cables were torn, and a small tsunami hit Antibes shortly after the failure. Hypotheses regarding the trigger mechanism include (i) vertical loading by construction of an embankment south of the airport, (ii) failure of a layer of sensitive clay within the slope sequence, and (iii) excess pore fluid pressures from charged aquifers in the underground. Over the previous decades, both the sensitive clay layers and the permeable sand and gravel layers were sampled to detect freshened waters. In 2007, the landslide scar and adjacent slopes were revisited for high-resolution seafloor mapping and systematic sampling. Results from half a dozen gravity and push cores in the shallow slope area reveal a limited zone of freshening (i.e. groundwater influence). A 100-250 m wide zone of the margin shows pore water salinities of 5-50% SW concentration and depletion in Cl, SO4, but Cr enrichment, while cores east or west of the landslide scar show regular SW profiles. Most interestingly, the three cores inside the landslide scar hint towards a complex hydrological system with at least two sources for groundwater. The aquifer system also showed strong freshening after a period of several months without significant precipitation. This freshening implies that charged coarse-grained layers represent a permanent threat to the slope's stability, not just after periods of major rainfall such as in October 1979.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La subsidencia del terreno constituye un riesgo geotécnico capaz de afectar a amplias zonas del territorio. Este fenómeno puede producirse por la consolidación de los suelos finos de un sistema acuífero, disolución y colapso de materiales yesíferos, actuaciones humanes, etc. Muchas regiones del mundo, y gran parte de la geografía peninsular, pueden verse afectadas de manera significativa por este fenómeno. En este proyecto se pretende crear una metodología de trabajo que se pueda aplicar en cualquier ámbito geográfico para el control de las subsidencias. Para la realización de esta metodología se han tomado tres técnicas de auscultación de subsidencias, nivelación geométrica de precisión, nivelación GPS y DinSAR, y comparado sus pros y contras, así como las precisiones esperadas y el organigrama de trabajo. Para que se vea mejor la funcionalidad del sistema, se ha procedido a la implantación teórica del mismo en una localización al Norte de la ciudad de Madrid con un escenario realista. Abstract Subsidence is a geotechnical risk which can affect large countryside areas. This phenomenon may be produced by the consolidation of an aquifer system fine soils, dissolution and collapse of gypsum materials, human actions, etc. Many regions of the world, and much of the Iberian Peninsula, may be significantly affected by this condition. This project aims to create a methodology that can be applied in any geographical area to control subsidence. For this purpose, three subsidence monitoring techniques have been studied. Those are precision geometric leveling, GPS leveling and DInSAR. During the project, pros and cons as well as the precisions expected and work schedule have been studied and compared. The subsidence auscultation system has been theoretically implemented in a location. This location is a realistic stage located north of Madrid

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Subsidence is a natural hazard that affects wide areas in the world causing important economic costs annually. This phenomenon has occurred in the metropolitan area of Murcia City (SE Spain) as a result of groundwater overexploitation. In this work aquifer system subsidence is investigated using an advanced differential SAR interferometry remote sensing technique (A-DInSAR) called Stable Point Network (SPN). The SPN derived displacement results, mainly the velocity displacement maps and the time series of the displacement, reveal that in the period 2004–2008 the rate of subsidence in Murcia metropolitan area doubled with respect to the previous period from 1995 to 2005. The acceleration of the deformation phenomenon is explained by the drought period started in 2006. The comparison of the temporal evolution of the displacements measured with the extensometers and the SPN technique shows an average absolute error of 3.9±3.8 mm. Finally, results from a finite element model developed to simulate the recorded time history subsidence from known water table height changes compares well with the SPN displacement time series estimations. This result demonstrates the potential of A-DInSAR techniques to validate subsidence prediction models as an alternative to using instrumental ground based techniques for validation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A twenty-year period of severe land subsidence evolution in the Alto Guadalentín Basin (southeast Spain) is monitored using multi-sensor SAR images, processed by advanced differential interferometric synthetic aperture radar (DInSAR) techniques. The SAR images used in this study consist of four datasets acquired by ERS-1/2, ENVISAT, ALOS and COSMO-SkyMed satellites between 1992 and 2012. The integration of ground surface displacement maps retrieved for different time periods allows us to quantify up to 2.50 m of cumulated displacements that occurred between 1992 and 2012 in the Alto Guadalentín Basin. DInSAR results were locally compared with global positioning system (GPS) data available for two continuous stations located in the study area, demonstrating the high consistency of local vertical motion measurements between the two different surveying techniques. An average absolute error of 4.6 ± 4 mm for the ALOS data and of 4.8 ± 3.5 mm for the COSMO-SkyMed data confirmed the reliability of the analysis. The spatial analysis of DInSAR ground surface displacement reveals a direct correlation with the thickness of the compressible alluvial deposits. Detected ground subsidence in the past 20 years is most likely a consequence of a 100–200 m groundwater level drop that has persisted since the 1970s due to the overexploitation of the Alto Guadalentín aquifer system. The negative gradient of the pore pressure is responsible for the extremely slow consolidation of a very thick (> 100 m) layer of fine-grained silt and clay layers with low vertical hydraulic permeability (approximately 50 mm/h) wherein the maximum settlement has still not been reached.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La prima parte di questo lavoro di tesi tratta dell’interazione tra un bacino di laminazione e il sottostante acquifero: è in fase di progetto, infatti, la costruzione di una cassa di espansione sul torrente Baganza, a monte della città di Parma. L’obiettivo di tale intervento è di ridurre il rischio di esondazione immagazzinando temporaneamente, in un serbatoio artificiale, la parte più pericolosa del volume di piena che verrebbe rilasciata successivamente con portate che possono essere agevolmente contenute nel tratto cittadino del torrente. L’acquifero è stato preliminarmente indagato e monitorato permettendone la caratterizzazione litostratigrafica. La stratigrafia si può riassumere in una sequenza di strati ghiaioso-sabbiosi con successione di lenti d’argilla più o meno spesse e continue, distinguendo due acquiferi differenti (uno freatico ed uno confinato). Nel presente studio si fa riferimento al solo acquifero superficiale che è stato modellato numericamente, alle differenze finite, per mezzo del software MODFLOW_2005. L'obiettivo del presente lavoro è di rappresentare il sistema acquifero nelle condizioni attuali (in assenza di alcuna opera) e di progetto. La calibrazione è stata condotta in condizioni stazionarie utilizzando i livelli piezometrici raccolti nei punti d’osservazione durante la primavera del 2013. I valori di conducibilità idraulica sono stati stimati per mezzo di un approccio geostatistico Bayesiano. Il codice utilizzato per la stima è il bgaPEST, un software gratuito per la soluzione di problemi inversi fortemente parametrizzati, sviluppato sulla base dei protocolli del software PEST. La metodologia inversa stima il campo di conducibilità idraulica combinando osservazioni sullo stato del sistema (livelli piezometrici nel caso in esame) e informazioni a-priori sulla struttura dei parametri incogniti. La procedura inversa richiede il calcolo della sensitività di ciascuna osservazione a ciascuno dei parametri stimati; questa è stata valutata in maniera efficiente facendo ricorso ad una formulazione agli stati aggiunti del codice in avanti MODFLOW_2005_Adjoint. I risultati della metodologia sono coerenti con la natura alluvionale dell'acquifero indagato e con le informazioni raccolte nei punti di osservazione. Il modello calibrato può quindi essere utilizzato come supporto alla progettazione e gestione dell’opera di laminazione. La seconda parte di questa tesi tratta l'analisi delle sollecitazioni indotte dai percorsi di flusso preferenziali causati da fenomeni di piping all’interno dei rilevati arginali. Tali percorsi preferenziali possono essere dovuti alla presenza di gallerie scavate da animali selvatici. Questo studio è stato ispirato dal crollo del rilevato arginale del Fiume Secchia (Modena), che si è verificato in gennaio 2014 a seguito di un evento alluvionale, durante il quale il livello dell'acqua non ha mai raggiunto la sommità arginale. La commissione scientifica, la cui relazione finale fornisce i dati utilizzati per questo studio, ha attribuito, con molta probabilità, il crollo del rilevato alla presenza di tane di animali. Con lo scopo di analizzare il comportamento del rilevato in condizioni integre e in condizioni modificate dall'esistenza di un tunnel che attraversa il manufatto arginale, è stato realizzato un modello numerico 3D dell’argine mediante i noti software Femwater e Feflow. I modelli descrivono le infiltrazioni all'interno del rilevato considerando il terreno in entrambe le porzioni sature ed insature, adottando la tecnica agli elementi finiti. La tana è stata rappresentata da elementi con elevata permeabilità e porosità, i cui valori sono stati modificati al fine di valutare le diverse influenze sui flussi e sui contenuti idrici. Per valutare se le situazioni analizzate presentino o meno il verificarsi del fenomeno di erosione, sono stati calcolati i valori del fattore di sicurezza. Questo è stato valutato in differenti modi, tra cui quello recentemente proposto da Richards e Reddy (2014), che si riferisce al criterio di energia cinetica critica. In ultima analisi è stato utilizzato il modello di Bonelli (2007) per calcolare il tempo di erosione ed il tempo rimanente al collasso del rilevato.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An integrated surface-subsurface hydrological model of Everglades National Park (ENP) was developed using MIKE SHE and MIKE 11 modeling software. The model has a resolution of 400 meters, covers approximately 1050 square miles of ENP, includes 110 miles of drainage canals with a variety of hydraulic structures, and processes hydrological information, such as evapotranspiration, precipitation, groundwater levels, canal discharges and levels, and operational schedules. Calibration was based on time series and probability of exceedance for water levels and discharges in the years 1987 through 1997. Model verification was then completed for the period of 1998 through 2005. Parameter sensitivity in uncertainty analysis showed that the model was most sensitive to the hydraulic conductivity of the regional Surficial Aquifer System, the Manning's roughness coefficient, and the leakage coefficient, which defines the canal-subsurface interaction. The model offers an enhanced predictive capability, compared to other models currently available, to simulate the flow regime in ENP and to forecast the impact of topography, water flows, and modifying operation schedules.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The concentrations of tritium (3H) and helium isotopes (3He and4He) were used as tracers of groundwater flow in the surficial aquifer system (SAS) beneath Everglades National Park (ENP), south Florida. From ages determined by 3H/3He dating techniques, groundwater within the upper 28 m originated within the last 30 years. Below 28 m, waters originated prior to 30 years before present with evidence of mixing at the interface. Interannual variation of the 3H/3He ages within the upper 28 m was significant throughout the 3 year investigation, corresponding with varying hydrologic conditions. In the region of Taylor Slough Bridge, younger groundwater was consistently detected below older groundwater in the Biscayne Aquifer, suggesting preferential flow to the lower part of the aquifer. An increase in 4He with depth in the SAS indicated that radiogenic 4He produced in the underlying Hawthorn Group migrates into the SAS by diffusion. Higher Δ4He values in brackish groundwaters compared to fresh waters from similar depths suggested a possible enhanced vertical transport of4He in the seawater mixing zone. Groundwater salinity measurements indicated the presence of a wide (6–28 km) seawater mixing zone. Comparison of groundwater levels with surface water levels in this zone indicated the potential for brackish groundwater discharge to the overlying Everglades surface water.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Increasing dependence on groundwater in the Wakal River basin, India, jeopardizes water supply sustainability. A numerical groundwater model was developed to better understand the aquifer system and to evaluate its potential in terms of quantity and replenishment. Potential artificial recharge areas were delineated using landscape and hydrogeologic parameters, Geographic Information System (GIS), and remote sensing. Groundwater models are powerful tools for recharge estimation when transmissivity is known. Proper recharge must be applied to reproduce field-measured heads. The model showed that groundwater levels could decline significantly if there are two drought years in every four years that result in reduced recharge, and groundwater withdrawal is increased by 15%. The effect of such drought is currently uncertain however, because runoff from the basin is unknown. Remote sensing and GIS revealed areas with slopes less than 5%, forest cover, and Normalized Difference Vegetative Index greater than 0.5 that are suitable recharge sites.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study area is within the Pirangi River Basin, eastern sector of Rio Grande do Norte state, where is located of the Parnamirim city. It has an area of approximately 370 km². Urbanization has developed much fast without an appropriate infrastructure, mainly by the lack of sewage systems, with risks of contamination of groundwater that may cause serious damage to the health of the population. The Barreiras Aquifer System groundwater in the area represents the main source of water supply for urban and rural populations. The use of groundwater occurs without adequate planning and therefore, important recharge areas are being occupied. This study was conducted to quantify the use and evaluation of the potential of groundwater, in order to increase good water quality supply and lower risks of being affected by polluting activities. With these objectives, the following activities were carried out: 268 points of water have been registered; characterization of the lithological, thickness and hydrogeological structure of the Barreiras aquifer, based on the correlation of well logs; and evaluation of hydrodynamic parameters of the aquifer, from the interpretation of results well pumping tests. It was found that the saturated thickness increases from west to east towards the sea, with values ranging from 15,47-56,5 m with an average of 32,45 m. The hydrodynamic parameters using Cooper-Jacob method were: average transmissivity of 5,9x10-3 m²/s and average hydraulic conductivity 2,82x10-4 m/s. The effective porosity is of 15%, obtained by applying Biecinski equation. The potentiometric map shows the main direction of groundwater flow, from west to east, and identifies the recharge areas corresponding to the region of the tablelands of the "Barreiras". The river valleys refer to the discharge areas of the aquifer system. The Recharge was estimated at 253 mm/year, which corresponds to the 16.4% rate of infiltration.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study area is within the Pirangi River Basin, eastern sector of Rio Grande do Norte state, where is located of the Parnamirim city. It has an area of approximately 370 km². Urbanization has developed much fast without an appropriate infrastructure, mainly by the lack of sewage systems, with risks of contamination of groundwater that may cause serious damage to the health of the population. The Barreiras Aquifer System groundwater in the area represents the main source of water supply for urban and rural populations. The use of groundwater occurs without adequate planning and therefore, important recharge areas are being occupied. This study was conducted to quantify the use and evaluation of the potential of groundwater, in order to increase good water quality supply and lower risks of being affected by polluting activities. With these objectives, the following activities were carried out: 268 points of water have been registered; characterization of the lithological, thickness and hydrogeological structure of the Barreiras aquifer, based on the correlation of well logs; and evaluation of hydrodynamic parameters of the aquifer, from the interpretation of results well pumping tests. It was found that the saturated thickness increases from west to east towards the sea, with values ranging from 15,47-56,5 m with an average of 32,45 m. The hydrodynamic parameters using Cooper-Jacob method were: average transmissivity of 5,9x10-3 m²/s and average hydraulic conductivity 2,82x10-4 m/s. The effective porosity is of 15%, obtained by applying Biecinski equation. The potentiometric map shows the main direction of groundwater flow, from west to east, and identifies the recharge areas corresponding to the region of the tablelands of the "Barreiras". The river valleys refer to the discharge areas of the aquifer system. The Recharge was estimated at 253 mm/year, which corresponds to the 16.4% rate of infiltration.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"*GPO:2008--339-126/80035."

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar cenários de níveis freáticos extremos, em bacia hidrográfica, por meio de métodos de análise espacial de dados geográficos. Avaliou-se a dinâmica espaço‑temporal dos recursos hídricos subterrâneos em área de afloramento do Sistema Aquífero Guarani. As alturas do lençol freático foram estimadas por meio do monitoramento de níveis em 23 piezômetros e da modelagem das séries temporais disponíveis de abril de 2004 a abril de 2011. Para a geração de cenários espaciais, foram utilizadas técnicas geoestatísticas que incorporaram informações auxiliares relativas a padrões geomorfológicos da bacia, por meio de modelo digital de terreno. Esse procedimento melhorou as estimativas, em razão da alta correlação entre altura do lençol e elevação, e agregou sentido físico às predições. Os cenários apresentaram diferenças quanto aos níveis considerados extremos - muito profundos ou muito superficiais - e podem subsidiar o planejamento, o uso eficiente da água e a gestão sustentável dos recursos hídricos na bacia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study evaluates the spatial variability of saturated hydraulic conductivity in the soil in an area of 51,850 ha at the headwaters of the Araguaia River MT/GO. This area is highly vulnerable because it is a location of recharging through natural water infiltration of the Guarani Aquifer System and an area of intense increases in agriculture since its adoption by growers in the last 30 years. Soil samples were collected at 383 points, geographically located by GPS. The samples were collected from depths of 0 - 20 cm and 60 - 80 cm. Exploratory statistics and box-plot were used in the descriptive analysis and semivariogram were constructed to determine the spatial model. The exploratory analysis showed that the mean hydraulic conductivity in the superficial layer was less than at the level of 60-80 cm; however, the greatest variability evaluated with a coefficient of variation also was from this layer. Data tended towards a normal distribution. These results can be explained by the greater soil compaction in the superficial layer. The semivariogram models, adjusted for the two layers, were exponential and demonstrated moderate and strong dependence, with ranges of 5000 and 3000 utm respectively. It was concluded that soil use is influencing the spatial distribution model of the hydraulic conductivity in the region.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The problem of pumping an aquifer in an aquifer-water table aquitard system is considered, accounting for the elastic properties of both the aquifer and the aquitard, the gravity drainage in the aquitard and treating the water table as an unknown boundary. The coupled partial differential equations are nondimensionalised, yielding three principal parameters governing the problem. The numerical solution of these equations is obtained for a wide range of parameter values. Type curves are generated and their use is illustrated through a field application.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Anomalous concentrations of Cr(VI) occur in groundwaters of the Adamantina Aquifer, in a large region in the western state of Sao Paulo, sometimes exceeding the potability limit (0.05 mg L(-1)). To identify the possible geochemical reactions responsible for the occurrence of Cr in groundwater in Urania, borehole rock samples were collected in order to carry out mineralogical and chemical analyses. In addition, multilevel monitoring wells were installed and groundwater samples were analyzed. Analyses of the borehole rock samples show the occurrence of a geochemical anomaly of Cr in the quartzose sandstones (average concentrations of 221 ppm). Chrome-diopside is one of the main minerals contributing to this anomaly, having an average Cr content of 1505 ppm. Sequential extraction experiments indicated weakly adsorbed Cr in the order of 0.54 ppm, and this quantity is enough to provide the Cr concentrations observed in groundwater. Groundwaters from the monitoring wells proved to be stratified, with the highest concentrations of Cr(VI) (0.13 mg L(-1)) being associated with high redox and pH values (over 10) and high concentrations of Na. Geochemical reactions that may explain the release of Cr from the solid phase to groundwater involve the release of Cr(III) from minerals (like chrome-diopside and Cr-Fe hydroxide), followed by oxidation of Cr(III) to Cr(VI), probably related to the reduction of Mn oxides present in the aquifer. Then cation exchange occurs and dissolution of carbonates which increases the pH of groundwater, resulting in the desorption and mobilization of Cr(VI) into groundwater. (C) 2011 Elsevier Ltd. All rights reserved.