994 resultados para BLASTOCYST IMPLANTATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implantation of a phakic iris claw intraocular lens is a common, effective and safe procedure to correct high myopia, hyperopia and astigmatism [2]. Due to the nature of its fixation on the iris using claws, chronic irritation and inflammation have remained a major concern with the Artisan® lens since its market introduction in 1998. Following iris claw implantation, monitoring of postoperative inflammation is mandatory [4][7]. Usually, signs of inflammation can be detected in the anterior chamber during the early postoperative period. We present here the first case of late-onset inflammation after implantation of an iris claw lens triggered by an iris varix. The iris varix is a rare benign iris vascular abnormality, with a low prevalence as a solitary primary lesion in the general population and little is known about its clinical characteristics [1][5][6]. This report shows that an iris varix could be a cause of a late onset and chronic inflammation after phakic Artisan® lens implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microstructural analysis of silicon-on-insulator samples obtained by high dose oxygen ion implantation was performed by Raman scattering. The samples analyzed were obtained under different conditions thus leading to different concentrations of defects in the top Si layer. The samples were implanted with the surface covered with SiO2 capping layers of different thicknesses. The spectra measured from the as-implanted samples were fitted to a correlation length model taking into account the possible presence of stress effects in the spectra. This allowed quantification of both disorder effects, which are determined by structural defects, and residual stress in the top Si layer before annealing. These data were correlated to the density of dislocations remaining in the layer after annealing. The analysis performed corroborates the existence of two mechanisms that generate defects in the top Si layer that are related to surface conditions during implantation and the proximity of the top Si/buried oxide layer interface to the surface before annealing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-delà de la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transapical aortic valve implantation is indicated in high-risk patients with aortic stenosis and peripheral vascular disease requiring aortic valve replacement. Minimally invasive direct coronary artery bypass grafting is also a valid, minimally invasive option for myocardial revascularization in patients with critical stenosis on the anterior descending coronary artery. Both procedures are performed through a left minithoracotomy, without cardiopulmonary bypass, aortic cross-clamping, and cardioplegic arrest. We describe a successful combined transapical aortic valve implantation and minimally invasive direct coronary bypass in a high-risk patient with left anterior descending coronary artery occlusion and severe aortic valve stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the efficacy and safety of Baerveldt shunt (BS) implantation compared to combined phacoemulsification and Baerveldt shunt implantation (PBS). This study was designed to detect a difference in IOP reduction of 20% (~4mmHg) between groups with 90% power. Methods: Sixty patients with medically uncontrolled glaucoma, prospectively underwent either or BS implantation with phacoemulsification (Group PBS; n=30) or BS implantation alone (group BS; n=30, pseudophakic eyes only). Groups were matched for age, glaucoma subtype and length of follow-up. Pre and post-operative measures recorded included patient demographics, visual acuity, IOP, number of glaucoma medications (GMs) and all complications. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline with or without GMs. Results: Age of PBS and BS groups was 61 vs 62 years respectively (p=0.72*). There were no significant differences in preoperative baseline characteristics: PBS vs PB, mean IOP =25.5mmHg (standard deviation (SD); ±10.3mmHg) vs 26.1mmHg (SD ±10.6mmHg), p=0.81*; mean GMs=3.0 (SD ±1.1) vs 3.1 (SD ±1.0), p=0.83*; mean VA=0.3 vs 0.3, p=0.89*. At year one there were no significant differences observed between groups in post-operative IOP, GMs or VA, mean IOP =14.1mmHg (SD ±5.4mmHg) vs 11.5 mmHg (SD ±4.2mmHg), p=0.12*; mean GMs=1.6 (SD ±1.4) vs 1.1 (SD ±1.1), p=0.23*; mean VA=0.5 vs 0.4, p=0.46*. Complication rates were similar between the two groups (7% vs 14%). Success rate was lower in eyes with PBS (71%) than with BS (88%), however this did not reach statistical significance (p=0.95, log-rank test). * two-sample t-test Conclusions: There were no significant differences at year one in success or complication rates between PBS and BS groups suggesting that simultaneous phacoemulsification does not have a marked (difference of >4mmHg) effect on tube function. IOP reduction and success were less in the PBS group, a larger sample (n=120) would be required to investigate if there is a 10% difference in IOP reduction between groups, however it is unclear if this would be a clinically significant difference to justify separate surgeries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transapical transcatheter aortic valve implantation is an emerging technique for high-risk patients with symptomatic aortic valve stenosis, peripheral vascular disease, and severe concomitant comorbidities. However, a previous major surgical intervention involving the left hemithorax and the lung has always been considered a technical surgical challenge or even a potential contraindication for this minimally invasive procedure. With this report, we demonstrate, for the first time, that a previous left pneumonectomy followed by mediastinal radiotherapy does not affect the feasibility of transapical transcatheter aortic valve implantation, and we discuss the preoperative workup and the peculiar intraoperative cardiac imaging and surgical assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylatebased nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (a=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.