999 resultados para Audit sampling
Resumo:
A new report by the Healthcare Commission and Audit Commission assesses the impact government policy has had on: narrowing health inequalities; improving sexual and mental health; and reducing smoking, alcohol misuse and obesity.
Health Equity Audit Made Simple: A briefing for Primary Care Trusts and Local Strategic Partnerships
Resumo:
A working/ consultation document outlining the key drivers and steps for undertaking health equity audit as required in the Performance and Planning Framework (PPF) 2003-2006
Resumo:
A briefing aiming to provide guidance to the NHS and local government on undertaking HEA. Aims to increase understanding of the impact of social, economic and environmental influences on health and health inequalities, and to promote effective action.
Resumo:
The Myocardial Infarction Audit Project (MINAP) began in late 1998 when a broadly based steering group developed a dataset for acute myocardial infarction (AMI). This allowed clinicians to examine the management of myocardial infarction within their hospitals against targets specified by the National Service Framework for Coronary Heart Disease (NSF). The audit project produces annual reports "How the NHS manages heart attacks" to show the performance of hospitals, ambulance services and cardiac networks in England and Wales against national standards and targets for the care of heart attack patients. MINAP has recently changed its name from the Myocardial Infarction National Audit Project to the Myocardial Ischaemia National Audit Project to reflect the importance of all acute coronary syndromes.
Resumo:
BACKGROUND: Mediastinal lymph-node dissection was compared to systematic mediastinal lymph-node sampling in patients undergoing complete resection for non-small cell lung cancer with respect to morbidity, duration of chest tube drainage and hospitalization, survival, disease-free survival, and site of recurrence. METHODS: A consecutive series of one hundred patients with non-small-cell lung cancer, clinical stage T1-3 N0-1 after standardized staging, was divided into two groups of 50 patients each, according to the technique of intraoperative mediastinal lymph-node assessment (dissection versus sampling). Mediastinal lymph-node dissection consisted of removal of all lymphatic tissues within defined anatomic landmarks of stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side according to the classification of the American Thoracic Society. Systematic mediastinal lymph-node sampling consisted of harvesting of one or more representative lymph nodes from stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side. RESULTS: All patients had complete resection. A mean follow-up time of 89 months was achieved in 92 patients. The two groups of patients were comparable with respect to age, gender, performance status, tumor stage, histology, extent of lung resection, and follow-up time. No significant difference was found between both groups regarding the duration of chest tube drainage, hospitalization, and morbidity. However, dissection required a longer operation time than sampling (179 +/- 38 min versus 149 +/- 37 min, p < 0.001). There was no significant difference in overall survival between the two groups; however, patients with stage I disease had a significantly longer disease-free survival after dissection than after sampling (60.2 +/- 7 versus 44.8 +/- 8 months, p < 0.03). Local recurrence was significantly higher after sampling than after dissection in patients with stage I tumor (12.5% versus 45%, p = 0.02) and in patients with nodal tumor negative mediastinum (N0/N1 disease) (46% versus 13%, p = 0.004). CONCLUSION: Our results suggest that mediastinal lymph-node dissection may provide a longer disease-free survival in stage I non-small cell lung cancer and, most importantly, a better local tumor control than mediastinal lymph-node sampling after complete resection for N0/N1 disease without leading to increased morbidity.
Resumo:
One of the key aspects in 3D-image registration is the computation of the joint intensity histogram. We propose a new approach to compute this histogram using uniformly distributed random lines to sample stochastically the overlapping volume between two 3D-images. The intensity values are captured from the lines at evenly spaced positions, taking an initial random offset different for each line. This method provides us with an accurate, robust and fast mutual information-based registration. The interpolation effects are drastically reduced, due to the stochastic nature of the line generation, and the alignment process is also accelerated. The results obtained show a better performance of the introduced method than the classic computation of the joint histogram
Resumo:
BACKGROUND Preanalytical mistakes (PAMs) in samples usually led to rejection upon arrival to the clinical laboratory. However, PAMs might not always be detected and result in clinical problems. Thus, PAMs should be minimized. We detected PAMs in samples from Primary Health Care Centres (PHCC) served by our central laboratory. Thus, the goal of this study was to describe the number and types of PAMs, and to suggest some strategies for improvement. METHODS The presence of PAMs, as sample rejection criteria, in samples submitted from PHCC to our laboratory during October and November 2007 was retrospectively analysed. RESULTS Overall, 3885 PAMs (7.4%) were detected from 52,669 samples for blood analyses. This included missed samples (n=1763; 45.4% of all PAMs, 3.3% of all samples), haemolysed samples (n=1408; 36.2% and 2.7%, respectively), coagulated samples (n=391; 10% and 0.7%, respectively), incorrect sample volume (n=110; 2.8% and 0.2%, respectively), and others (n=213; 5.5% and 0.4%, respectively). For urine samples (n=18,852), 1567 of the samples were missing (8.3%). CONCLUSIONS We found the proportion of PAMs in blood and urine samples to be 3-fold higher than that reported in the literature. Therefore, strategies for improvement directed towards the staff involved, as well as an exhaustive audit of preanalytical process are needed. To attain this goal, we first implemented a continued education programme, financed by our Regional Health Service and focused in Primary Care Nurses.
Resumo:
BACKGROUNDS AUDIPOC is a nationwide clinical audit that describes the characteristics, interventions and outcomes of patients admitted to Spanish hospitals because of an exacerbation of chronic obstructive pulmonary disease (ECOPD), assessing the compliance of these parameters with current international guidelines. The present study describes hospital resources, hospital factors related to case recruitment variability, patients' characteristics, and adherence to guidelines. METHODOLOGY/PRINCIPAL FINDINGS An organisational database was completed by all participant hospitals recording resources and organisation. Over an 8-week period 11,564 consecutive ECOPD admissions to 129 Spanish hospitals covering 70% of the Spanish population were prospectively identified. At hospital discharge, 5,178 patients (45% of eligible) were finally included, and thus constituted the audited population. Audited patients were reassessed 90 days after admission for survival and readmission rates. A wide variability was observed in relation to most variables, hospital adherence to guidelines, and readmissions and death. Median inpatient mortality was 5% (across-hospital range 0-35%). Among discharged patients, 37% required readmission (0-62%) and 6.5% died (0-35%). The overall mortality rate was 11.6% (0-50%). Hospital size and complexity and aspects related to hospital COPD awareness were significantly associated with case recruitment. Clinical management most often complied with diagnosis and treatment recommendations but rarely (<50%) addressed guidance on healthy life-styles. CONCLUSIONS/SIGNIFICANCE The AUDIPOC study highlights the large across-hospital variability in resources and organization of hospitals, patient characteristics, process of care, and outcomes. The study also identifies resources and organizational characteristics associated with the admission of COPD cases, as well as aspects of daily clinical care amenable to improvement.
Field optimisation of MosquiTRAP sampling for monitoring Aedes aegypti Linnaeus (Diptera: Culicidae)
Resumo:
A sticky trap designed to capture gravid Aedes (Stegomyia) aegypti mosquitoes, MosquiTRAP, has been evaluated for monitoring this species in Brazil. However, the effects of trap densities on the capture rate of Ae. aegypti females and the sensitivity of vector detection are still unknown. After a preliminary study has identified areas of high and low female mosquito abundance, a set of experiments was conducted in four neighbourhoods of Belo Horizonte (state of Minas Gerais, Brazil) using densities of 1, 2, 4, 8, 16, 32 and 64 traps per block. Trap sensitivity (positive MosquiTRAP index) increased significantly when 1-8 MosquiTRAPs were installed per block in both high and low abundance areas. A strong fit was obtained for the total number of mosquitoes captured with increasing trap densities through a non-linear function (Box-Lucas) (r² = 0,994), which likely exhibits saturation towards an equilibrium level. The capacity of the Mean Female Aedes Index to distinguish between areas of high and low Ae. aegypti abundance was also investigated; the achieved differentiation was shown to be dependent on the MosquiTRAP density.
Resumo:
The method of sample recovery for trace detection and identification of explosives plays a critical role in several criminal investigations. After bombing, there can be difficulties in sending big objects to a laboratory for analysis. Traces can also be searched for on large surfaces, on hands of suspects or on surfaces where the explosive was placed during preparatory phases (e.g. places where an IED was assembled, vehicles used for transportation, etc.). In this work, triacetone triperoxide (TATP) was synthesized from commercial precursors following reported methods. Several portions of about 6 mg of TATP were then spread on different surfaces (e.g. floors, tables, etc.) or used in handling tests. Three different swabbing systems were used: a commercial swab, pre-wetted with propan-2-ol (isopropanol) and water (7:3), dry paper swabs, and cotton swabs wetted with propan-2-ol. Paper and commercial swabs were also used to sample a metal plate, where a small charge of about 4 g of TATP was detonated. Swabs were sealed in small glass jars with screw caps and Parafilm® M and sent to the laboratory for analysis. Swabs were extracted and analysed several weeks later by gas chromatography/mass spectrometry. All the three systems gave positive results, but wetted swabs collected higher amounts of TATP. The developed procedure showed its suitability for use in real cases, allowing TATP detection in several simulations, including a situation in which people wash their hands after handling the explosive.
Resumo:
Distribution, abundance, feeding behaviour, host preference, parity status and human-biting and infection rates are among the medical entomological parameters evaluated when determining the vector capacity of mosquito species. To evaluate these parameters, mosquitoes must be collected using an appropriate method. Malaria is primarily transmitted by anthropophilic and synanthropic anophelines. Thus, collection methods must result in the identification of the anthropophilic species and efficiently evaluate the parameters involved in malaria transmission dynamics. Consequently, human landing catches would be the most appropriate method if not for their inherent risk. The choice of alternative anopheline collection methods, such as traps, must consider their effectiveness in reproducing the efficiency of human attraction. Collection methods lure mosquitoes by using a mixture of olfactory, visual and thermal cues. Here, we reviewed, classified and compared the efficiency of anopheline collection methods, with an emphasis on Neotropical anthropophilic species, especially Anopheles darlingi, in distinct malaria epidemiological conditions in Brazil.