989 resultados para Artificial satellites, American
Resumo:
Climate variability in the African Soudano-Sahel savanna zone has attracted much attention because of the persistence of anomalously low rainfall. Past efforts to monitor the climate of this region have focused on rainfall and vegetation conditions, while land surface temperature (LST) has received less attention. Remote sensing of LST is feasible and possible at global scale. Most remotely sensed estimates of LST are based on the National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR) that are limited in their ability to capture the full diurnal cycle. Although more frequent observations are available from past geostationary satellites, their spatial resolution is coarser than that of polar orbiting satellites. In this study, the improved capabilities of the Spinning Enhanced Visible and Infrared Imager (SEVIRI) on the METEOSAT Second Generation (MSG) instrument are used to remotely sense the LST in the African Soudano-Sahel savanna zone at a resolution of 3 km and 15 minutes. In support of the Radiative Atmospheric Divergence using the ARM Mobile Facility (AMF), GERB and AMMA Stations (RADAGAST) project, African Monsoon Multidisciplinary Analyses (AMMA) project and the Department of Energy's Atmospheric Radiation Measurement (ARM) program, the ARM Mobile Facility was deployed during 2006 in this climatically sensitive region, thereby providing a unique opportunity to evaluate remotely sensed algorithms for deriving LST.
Resumo:
Two experiments examined the claim for distinct implicit and explicit learning modes in the artificial grammar-learning task (Reber, 1967, 1989). Subjects initially attempted to memorize strings of letters generated by a finite-state grammar and then classified new grammatical and nongrammatical strings. Experiment 1 showed that subjects' assessment of isolated parts of strings was sufficient to account for their classification performance but that the rules elicited in free report were not sufficient. Experiment 2 showed that performing a concurrent random number generation task under different priorities interfered with free report and classification performance equally. Furthermore, giving different groups of subjects incidental or intentional learning instructions did not affect classification or free report.
Resumo:
NOAA's National Environmental Satellite, Data, and Information Service (NESDIS) has generated sea surface temperature (SST) products from Geostationary Operational Environmental Satellite (GOES)-East (E) and GOES-West (W) on an operational basis since December 2000. Since that time, a process of continual development has produced steady improvements in product accuracy. Recent improvements extended the capability to permit generation of operational SST retrievals from the Japanese Multifunction Transport Satellite (MTSAT)-1R and the European Meteosat Second Generation (MSG) satellite, thereby extending spatial coverage. The four geostationary satellites (at longitudes of 75°W, 135°W, 140°E, and 0°) provide high temporal SST retrievals for most of the tropics and midlatitudes, with the exception of a region between 60° and 80°E. Because of ongoing development, the quality of these retrievals now approaches that of SST products from the polar-orbiting Advanced Very High Resolution Radiometer (AVHRR). These products from GOES provide hourly regional imagery, 3-hourly hemispheric imagery, 24-h merged composites, a GOES SST level 2 preprocessed product every 1/2 h for each hemisphere, and a match-up data file for each product. The MTSAT and the MSG products include hourly, 3-hourly, and 24-h merged composites. These products provide the user community with a reliable source of SST observations, with improved accuracy and increased coverage in important oceanographic, meteorological, and climatic regions.
Resumo:
This article presents SPARE-ICE, the Synergistic Passive Atmospheric Retrieval Experiment-ICE. SPARE-ICE is the first Ice Water Path (IWP) product combining infrared and microwave radiances. By using only passive operational sensors, the SPARE-ICE retrieval can be used to process data from at least the NOAA 15 to 19 and MetOp satellites, obtaining time series from 1998 onward. The retrieval is developed using collocations between passive operational sensors (solar, terrestrial infrared, microwave), the CloudSat radar, and the CALIPSO lidar. The collocations form a retrieval database matching measurements from passive sensors against the existing active combined radar-lidar product 2C-ICE. With this retrieval database, we train a pair of artificial neural networks to detect clouds and retrieve IWP. When considering solar, terrestrial infrared, and microwave-based measurements, we show that any combination of two techniques performs better than either single-technique retrieval. We choose not to include solar reflectances in SPARE-ICE, because the improvement is small, and so that SPARE-ICE can be retrieved both daytime and nighttime. The median fractional error between SPARE-ICE and 2C-ICE is around a factor 2, a figure similar to the random error between 2C-ICE ice water content (IWC) and in situ measurements. A comparison of SPARE-ICE with Moderate Resolution Imaging Spectroradiometer (MODIS), Pathfinder Atmospheric Extended (PATMOS-X), and Microwave Surface and Precipitation Products System (MSPPS) indicates that SPARE-ICE appears to perform well even in difficult conditions. SPARE-ICE is available for public use.
Resumo:
Objective: To evaluate the effect of artificial oocyte activation (AOA) on intracytoplasmic sperm injection (ICSI) cycles using surgically retrieved sperm.Design: Laboratory study.Setting: Fertility/assisted fertilization center.Patient(s): Couples undergoing surgical sperm retrieval for ICSI (n = 204).Intervention(s): Application of calcium ionophore A23187 for AOA.Main Outcome Measure(s): Cycles were divided into experimental groups according to the origin of the sperm used for injection and the type of azoospermia: [1] testicular sperm aspiration in nonobstructive-azoospermic patients (TESA-NOA group, n = 58), [2] TESA in obstructive-azoospermic patients (TESA-OA group, n = 48), [3] and percutaneous epididymal sperm aspiration in obstructive-azoospermic patients (PESA-OA, n = 98). For each experimental group, cycles where AOA was applied (subgroup: activation) were compared with cycles in which AOA was not applied (Subgroup: control). The fertilization, high-quality embryo, implantation, and pregnancy rates were compared among the subgroups.Result(s): For patients undergoing TESA, AOA did not improve ICSI outcomes for either type of azoospermia. However, for cases in which the injected sperm were retrieved from the epididymis, a statistically significantly increased rate of high-quality embryos was observed with AOA.Conclusion(s): Artificial oocyte activation may improve ICSI outcomes in azoospermic patients when epididymal, but not testicular spermatozoa, are injected. (Fertil Steril (R) 2009;92:131-6. (C)2009 by American Society for Reproductive Medicine.)
Resumo:
In this work, we focus our attention to the expansion of the disturbing function (R) which governs the dynamics of a satellite (natural or artificial) in the Neptune-Triton system. What makes this problem quite unusual, is the fact that a small inner satellite can be strongly disturbed by Triton which is moving in a highly inclined and retrograde orbit. These features are unique in our solar system. Although a lot of retrograde satellites are currently known, all of them have negligible mass and the), do not offer almost any perturbation on the others satellites. However, in the case of the inner satellites of Neptune, Triton is an interesting exception. In a highly inclined orbit, the perturbation it exerts on the neighbouring satellites of Neptune cannot be ignored even for the present scenario. However, in the future, this perturbation will be much more important because due to the tides, the orbit of Triton is contracting, whereas the semi major axes of the remaining inner satellites of Neptune will remain almost unaffected by the tides. In this work we first obtain the disturbing function in the retrograde case. After that, we generalize R for arbitrary inclination. Several numerical tests are presented and a possible future case of resonant configuration is briefly discussed as well. (c) 2005 COSPAR. Published by Elsevier Ltd. All rights reserved.
Resumo:
Data were collected and analysed from seven field sites in Australia, Brazil and Colombia on weather conditions and the severity of anthracnose disease of the tropical pasture legume Stylosanthes scabra caused by Colletotrichum gloeosporioides. Disease severity and weather data were analysed using artificial neural network (ANN) models developed using data from some or all field sites in Australia and/or South America to predict severity at other sites. Three series of models were developed using different weather summaries. of these, ANN models with weather for the day of disease assessment and the previous 24 h period had the highest prediction success, and models trained on data from all sites within one continent correctly predicted disease severity in the other continent on more than 75% of days; the overall prediction error was 21.9% for the Australian and 22.1% for the South American model. of the six cross-continent ANN models trained on pooled data for five sites from two continents to predict severity for the remaining sixth site, the model developed without data from Planaltina in Brazil was the most accurate, with >85% prediction success, and the model without Carimagua in Colombia was the least accurate, with only 54% success. In common with multiple regression models, moisture-related variables such as rain, leaf surface wetness and variables that influence moisture availability such as radiation and wind on the day of disease severity assessment or the day before assessment were the most important weather variables in all ANN models. A set of weights from the ANN models was used to calculate the overall risk of anthracnose for the various sites. Sites with high and low anthracnose risk are present in both continents, and weather conditions at centres of diversity in Brazil and Colombia do not appear to be more conducive than conditions in Australia to serious anthracnose development.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The present work introduces a new strategy of induction machines speed adjustment using an adaptive PID (Proportional Integral Derivative) digital controller with gain planning based on the artificial neural networks. This digital controller uses an auxiliary variable to determine the ideal induction machine operating conditions and to establish the closed loop gain of the system. The auxiliary variable value can be estimated from the information stored in a general-purpose artificial neural network based on CMAC (Cerebellar Model Articulation Controller).
Resumo:
This study aims to inventory and assess the aquatic macroinvertebrates fauna in two artificial reservoirs into conservation units with differences regarding conservation level and to anthropogenic impacts. The samplings were carried out in Caetetus Ecological Station and Bauru City Zoological Park, where some physical and chemical variables also were measured. The results obtained indicated that the Caetetus Ecological Station is more effective in the conservation of the diversity of aquatic macroinvertebrates compared to Bauru City Zoological Park. These results can be attributed to the strong anthropogenic impact suffered by the reservoir in Bauru and demonstrate the importance of these areas in maintaining the diversity of aquatic macroinvertebrates community.
Resumo:
Semen cryopreservation is still considered suboptimal due to lower fertility when compared to fresh semen. The reasons for the loss of fertility are various and related to irreversible damage caused to the cells during the freeze-thaw process. An alternative to conventional cryopreservation represents the use of chilled bull semen, preventing the damage associated with freezing, thereby guaranteeing greater sperm viability. The aim of this study was to describe the use of cooled bull semen as a strategy to increase the pregnancy for Fixed-Time Artificial Insemination (FTAI) of Nellore (Bos indicus) cows. One ejaculate of a select Nellore bull obtained by electroejaculation was used; the semen sample was fractioned into two aliquots: one diluted in Botu-Bov® extender containing 6.4% glycerol for cryopreservation (BB-F, frozen group) and one diluted in the same extender, free from cryoprotectants and used for cooling (BB-C, cooled semen group). The samples in the BB-C group were chilled to 5°C using an isothermic box and maintained for 24 h prior to use. A total of 349 lactating Nellore cows (70-90 days after birth) were synchronized by the insertion of a progesterone releasing device (1.0 g) and estradiol benzoate (2.0 mg i.m.) on a random day of the estrous cycle (Day 0); FTAI was performed 44-48 h after the removal of the device. The pregnancy rates were 45.71 and 61.49% (P<0.05), respectively, for the cryopreserved or chilled bovine semen groups. In conclusion, the use of bull semen cooled for 24 h represents an alternative to conventionally cryopreserved semen, as determined by the increase the pregnancy per artificial insemination in bovine herds. © 2012 Science Publication.
Resumo:
Objectives were to investigate progesterone concentrations and fertility comparing 2 different intervals from PGF2α treatment and induced ovulation in an estrogen-based ovulation synchronization protocol for timed artificial insemination (TAI) or timed embryo transfer (TET) in lactating dairy cows. A total of 1,058 lactating Holstein cows [primiparous (n=371) and multiparous (n=687)], yielding 34.1±0.33 kg of milk/d at various days in milk were randomly assigned to receive treatment with PGF2α on either d 7 or 8 of the following protocol: d 0: 2mg of estradiol benzoate + controlled internal drug release device; d 8: controlled internal drug release device removal + 1.0mg of estradiol cypionate; d 10: TAI or d 17: TET. Only cows with a corpus luteum at d 17 received an embryo and all cows received GnRH at TET. Pregnancy diagnoses were performed by detection (transrectal ultrasonography) of an embryo on d 28 or a fetus on d 60. Fertility [pregnancy per artificial insemination (P/AI) or pregnancy per embryo transfer (P/ET)] was affected by breeding technique (AI vs. ET) and time of PGF2α treatment (d 7 vs. 8) at the 28-d pregnancy diagnosis for TAI [32.9% (238) vs. 20.6% (168)] and TET cows [47% (243) vs. 40.7% (244)] and at the 60-d pregnancy diagnosis for TAI [30% (238) vs. 19.2% (168)] and TET cows [37.9% (243) vs. 33.5% (244)]. The progesterone (P4) concentration at d 10 altered fertility in TAI cows, with higher P/AI in cows with P4 concentration <0.1 ng/mL compared with cows with P4 concentration ≥0.1 ng/mL, and in ET cows, with higher P/ET in cows with P4 concentration <0.22 ng/mL compared with cows with P4 concentration ≥0.22 ng/mL. Prostaglandin F2α treatment at d 7 increased the percentage of cows with P4 <0.1 ng/mL on d 10 [39.4 (85) vs. 23.2 (54)]. Reducing the period between PGF2α and TAI from 72 to 48h in dairy cows resulted in a clear reduction in fertility in cows bred by TAI and a subtle negative effect in cows that received TET. The earlier PGF2α treatment benefits are most likely mediated through gamete transport, fertilization, or early embryo development and a more subtle effect of earlier PGF2α treatment that may be mediated through changes in the uterine or hormonal environment that manifests itself after ET on d 7. © 2013 American Dairy Science Association.
Resumo:
The objective of this study was to compare a GnRH-based to an estrogen/progesterone (E2/P4)-based protocol for estrous cycle synchronization and fixed timed artificial insemination (TAI), both designed for synchronization of ovulation and to reduce the period from follicular emergence until ovulation in cows with a synchronized follicular wave. A total of 1,190 lactating Holstein cows (primiparous: n = 685 and multiparous: n = 505) yielding 26.5 ± 0.30 kg of milk/d at 177 ± 5.02 d in milk were randomly assigned to receive one of the following programs: 5-d Cosynch protocol [d -8: controlled internal drug release (CIDR) + GnRH; d -3: CIDR removal + PGF2α; d -2: PGF2α; d 0: TAI + GnRH] or E2/P4 protocol (d -10: CIDR + estradiol benzoate; d -3: PGF2α; d -2: CIDR removal + estradiol cypionate; d 0: TAI). Rectal temperature and circulating progesterone (P4) were measured on d -3, -2, 0 (TAI), and 7. The estrous cycle was considered to be synchronized when P4 was ≥1.0 ng/mL on d 7 in cows that had luteolysis (P4 ≤0.4 ng/mL on d 0). To evaluate the effects of heat stress, cows were classified by number of heat stress events: 0, 1, and 2-or-more measurements of elevated body temperature (≥39.1°C). Pregnancy success (pregnancy per artificial insemination, P/AI) was determined at d 32 and 60 after TAI. The cows in the 5-d Cosynch protocol had increased circulating P4 at the time of PGF2α injection (2.66 ± 0.13 vs. 1.66 ± 0.13 ng/mL). The cows in the E2/P4 protocol were more likely to be detected in estrus (62.8 vs. 43.4%) compared with the cows in the 5-d Cosynch protocol, and expression of estrus improved P/AI in both treatments. The cows in the 5-d Cosynch protocol had greater percentage of synchronized estrous cycle (78.2%), compared with cows in the E2/P4 protocol (70.7%). On d 60, the E2/P4 protocol tended to improve P/AI (20.7 vs. 16.7%) and reduced pregnancy loss from 32 to 60 d (11.0 vs. 19.6%), compared with the 5-d Cosynch protocol. In cows with their estrous cycle synchronized, the E2/P4 protocol had greater P/AI (25.6 vs. 17.7%) on d 60 and lower pregnancy loss from 32 to 60 d (6.7 vs. 21.7%) compared with cows in the 5-d Cosynch protocol. Follicle diameter affected pregnancy loss from 32 to 60 d only in the cows in the 5-d Cosynch protocol, with smaller follicles resulting in greater pregnancy loss. Pregnancy per AI at d 60 was different between protocols in the cows with 2 or more measurements of heat stress (5-d Cosynch = 12.2% vs. E2/P4 = 22.8%), but not in the cows without or with 1 heat stress measurement. In conclusion, the 5-d Cosynch protocol apparently produced better estrous cycle synchronization than the E2/P4 protocol but did not improve P/AI. The potential explanation for these results is that increased E2 concentrations during the periovulatory period can improve pregnancy success and pregnancy maintenance, and this effect appears to be greatest in heat-stressed cows when circulating E2 may be reduced. © 2013 American Dairy Science Association.