951 resultados para Ankle-foot prosthesis
Resumo:
Introduction: Changes in gait cadence caused by challenging situations in daily life might induce higher demand for strength and propulsion in diabetic neuropathic (DN) subjects. Methods: Forty-six subjects (healthy and DN) walked at two cadences (self-selected and 25% higher). Kinematic and electromyographic data were obtained from lower limbs and compared across the gait cycle. Results: DN subjects showed a delayed peak in plantarflexor activity along the whole cycle (irrespective of cadence) compared with healthy subjects. However, during the imposed cadence, DN individuals showed reduced ankle range of motion along the entire cycle compared with the self-selected condition and healthy individuals walking at both cadences (P = 0.002). Conclusions: These findings suggest that when diabetic individuals face a new challenging situation that induces a higher demand for muscle strength and propulsion, the necessary range of motion and neuromuscular control around distal joints are insufficient. Muscle Nerve 44: 258-268, 2011
Resumo:
Background. We aimed at investigating the influence of diabetic neuropathy and previous history of plantar ulcers on electromyography (EMG) of the thigh and calf and on vertical ground reaction forces during gait. Methods. This study involved 45 adults divided into three groups: a control group (n = 16), diabetic neuropathic group (n = 19) and diabetic neuropathic group with previous history of plantar ulceration (it = 10). EMG of the right vastus lateralis, lateral gastrocnemius and tibialis anterior were studied during the stance phase. The peaks and time of peak occurrence were determined and a co-activation index between tibialis anterior and lateral gastrocnemius. In order to represent the effect of the changes in EMG, the first and second peaks and the minimum value of the vertical ground reaction force were also determined. Inter-group comparisons of the electromyographical and ground reaction forces variables were made using three MANCOVA (peaks and times of EMG and peaks of force) and one ANCOVA (co-activation index). Findings. The ulcerated group presented a delayed in the time of the lateral gastrocnemius and vastus lateralis peak occurrence in comparison to control`s. The lateral gastrocnemius delay may be related to the lower second vertical peak in diabetic subjects. However, the delay of the vastus lateralis did not cause any significant change on the first vertical peak. Interpretations. The vastus lateralis and lateral gastrocnemius delay demonstrate that ulcerated diabetic neuropathic patients have a motor deficit that could compromise their ability to walk, which was partially confirmed by changes on ground reaction forces during the push-off phase. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Objective: The purpose of this study was to analyze the range of movement of the ankle and the vertical ground reaction force involved in gait among diabetic patients with and without peripheral neuropathy. Sample and Method: 36 individuals were divided into three groups: Control group - CG: 10 individuals without diabetes, Diabetic group - DG: 10 individuals with diabetes without peripheral neuropathy and Neuropathy, and Diabetic neuropathic group - DNG: 16 individuals with diabetes and peripheral diabetic neuropathy. Gait - AMTI (R) OR6/6m and range of tibiotarsal joint movement - System Vicom 640 (R) was carried out in all the participants. Results: The first and second vertical ground reaction force peaks were statistically higher in the neuropathy group, and the range of ankle motion was lower in the Diabetes and Neuropathy groups. Conclusion: The range of movement of the tibiotarsal joint is lower in diabetics, regardless of the presence or absence of peripheral neuropathy, and diabetics with peripheral neuropathy show an increase in the first and second vertical ground reaction force peaks during walking.
Resumo:
Objective: The aim was to compare there ulcer classification systems as predictors of the outcome of diabetic foot ulcers; the Wagner, the University of Texas (UT) and the size (area, depth), sepsis, arteriopathy, denervation system (S(AD)SAD) systems in specialist clinic in Brazil. Methods: Ulcer area, depth, appearance, infection and associated ischaemia and neuropathy were recorded in a consecutive series of 94 subjects. A novel score, the S(AD)SAD score, was derived from the sum of individual items of the S(AD)SAD system, and was evaluated. Follow-up was for at least 6 months. The primary outcome measure was the incidence of healing. Results: Mean age was 57.6 years; 57 (60.6%) were made. Forty-eight ulcers (51.1%) healed without surgery; 11 (12.2%) subjects underwent minor amputation. Significant differences in terms of healing were observed for depth (P = 0.002), infection (P = 0.006) and denervation (P = 0.002) using the S(AD)SAD system, for UT grade (P = 0.002) and stage (P = 0.032) and for Wagner grades (P = 0.002). Ulcers with an S(AD)SAD score of <= 9 (total possible 15) were 7.6 times more likely to heal than scores >= 10 (P < 0.001). Conclusions: All three systems predicted ulcer outcome. The S(AD)SAD score of ulcer severity could represent a useful addition to routine clinical practice. The association between outcome and ulcer depth confirms earlier reports. The association with infection was stronger than that reported from the centres in Europe or North America. The very strong association with neuropathy has only previously been observed in Tanzania. Studies designed to compare the outcome in different countries should adopt systems of classification, which are valid for the populations studied.
Resumo:
The purpose of this study is to characterize the structure of the beak of Toco Toucan (Ramphastos toco) and to investigate means for arresting fractures in the rhinotheca using acrylic resin. The structure of the rhamphastid bill has been described as a sandwich structured composite having a thin exterior comprised of keratin and a thick foam core constructed of mineralized collagenous rods (trabeculae). The keratinous rhamphotheca consists of superposed polygonal scales (approximately 50 pm in diameter and 1 mu m in thickness). In order to simulate the orientation of loading to which the beak is subjected during exertion of bite force, for example, we conducted flexure tests on the dorso-ventral axis of the maxilla. The initially intact (without induced fracture) beak fractured in the central portion when subjected to a force of 270 N, at a displacement of 23 mm. The location of this fracture served as a reference for the fractures induced in other beaks tested. The second beak was fractured and repaired by applying resin on both lateral surfaces. The repaired maxilla sustained a force of 70 N with 6.5 mm deflection. The third maxilla was repaired similarly except that it was conditioned in acid for 60s prior to fixation with resin. It resisted a force of up to 63 N at 6 mm of deflection. The experimental results were compared with finite element calculations for unfractured beak in bending configuration. The repaired specimens were found to have strength equal to only one third of the intact beak. Finite element simulations allow visualization of how the beak system (sandwich shell and cellular core) sustains high flexural strength. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objectives: The aim of this study was to determine the precision of the measurements of 2 craniometric anatomic points-glabella and anterior nasal spine-in order to verify their possibility as potential locations for placing implants aimed at nasal prostheses retention. Methods: Twenty-six dry human skulls were scanned in a high-resolution spiral tomography with 1-mm axial slice thickness and 1-mm interval reconstruction using a bone tissue filter. Images obtained were stored and transferred to an independent workstation containing e-film imaging software. The measurements (in the glabella and anterior nasal fossa) were made independently by 2 observers twice for each measurement. Data were submitted to statistical analysis (parametric t test). Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements (P > .05). The standard error was found to be between 0.49 mm and 0.84 mrn for measurements in bone protocol, indicating a high /eve/ of precision. Conclusions: The measurements obtained in anterior nasal spine and glabella were considered precise and reproducible. Mean values of such measurements pointed to the possibility of implant placement in these regions, particularly in the anterior nasal spine.
Implant-supported prosthesis following Branemark protocol on electromyography of masticatory muscles
Resumo:
This research evaluated the effects of Branemark protocol on electromyography of the masseter and temporal muscles. The patients were divided into two groups: Group 1: patients who wore an implant-supported prosthesis in the mandibular arch following Branemark protocol, and maxillary removable complete dentures; Group II: dentate individuals (control). Electromyography was carried out at rest, right (RL) and left (LL) laterality, protrusion and maximum voluntary contraction (MVC). Data were compared by t-test. At rest, a higher electromyographic (EMG) activity was observed in Group I, and the values were significant in the right masseter and left temporal muscles. In RL, there were statistically significant differences for right masseter (P < 0.01), left masseter and temporal muscles and for the left temporal muscle in LL (P < 0.05). In protrusion, Group I presented a higher EMG activity, and there was a statistically significant difference for the right masseter muscle (RM) (P < 0.05). In MVC, the EMG values were higher in Group II (control), but significant just for the right temporal muscle (P < 0.05). In conclusion, individuals with mandibular fixed dentures supported according to the Branemark protocol and maxillary removable complete dentures showed a higher activity of masticatory muscles during the mandibular postural clinical conditions examined; however, in the MVC, Group I presented lower values when compared to dentate group. Despite presenting different EMG values in all of the clinical conditions, both groups showed similar EMG patterns of muscle activation which demonstrates that the proposed treatment can be considered as a good option for oral rehabilitation.
Resumo:
Denture stomatitis is a primarily oral disease that affects denture wearers. The presence of Candida albicans in the palatal mucosa, on the internal surface of the maxillary denture, and in the blood of patients with denture stomatitis was evaluated. Although the results did not show C albicans in the bloodstream of patients, a strong relationship between denture stomatitis and Candida sp was confirmed for both the palatal mucosa and maxillary denture. Int J Prosthodont 2010;23:158-159.
Resumo:
Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.
Resumo:
In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.