975 resultados para Aneurysm, false


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Attorney General’s Consumer Protection Division receives hundreds of calls and consumer complaints every year. Follow these tips to avoid unexpected expense and disappointments. This record is about: Con-artists cash in on people's false hopes and wishful thinking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under the influence of intelligence-led policing models, crime analysis methods have known of important developments in recent years. Applications have been proposed in several fields of forensic science to exploit and manage various types of material evidence in a systematic and more efficient way. However, nothing has been suggested so far in the field of false identity documents.This study seeks to fill this gap by proposing a simple and general method for profiling false identity documents which aims to establish links based on their visual forensic characteristics. A sample of more than 200 false identity documents including French stolen blank passports, counterfeited driving licenses from Iraq and falsified Bulgarian driving licenses was gathered from nine Swiss police departments and integrated into an ad hoc developed database called ProfID. Links detected automatically and systematically through this database were exploited and analyzed to produce strategic and tactical intelligence useful to the fight against identity document fraud.The profiling and intelligence process established for these three types of false identity documents has confirmed its efficiency, more than 30% of documents being linked. Identity document fraud appears as a structured and interregional criminality, against which material and forensic links detected between false identity documents might serve as a tool for investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stent implantation was performed on two patients to treat chronic dissecting aneurysms of the upper cervical internal carotid artery. Treatment was decided because of the youth of the patients, their medical history of subarachnoid hemorrhage, and the angiographic findings associated with the dissection. Normal arteriographic morphology was obtained after deployment of a single self-expandable stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report our results of endovascular aneurysm repair (EVAR) over a 10-year period using systematic preoperative collateral artery embolization. METHODS: From 1999 until 2009, 124 patients (117 men; mean age 70.8 years) with abdominal aortic aneurysm (AAA) underwent embolization of patent lumbar and/or inferior mesenteric arteries prior to elective EVAR procedures. Embolization was systematically attempted and, whenever possible, performed using microcoils and a coaxial technique. Follow-up included computed tomography and/or magnetic resonance imaging and abdominal radiography. RESULTS: The technical success for EVAR was 96% (119/124), with 4 patients dying within 30 days (3.2% perioperative mortality) and 1 type III endoleak accounting for the failures. Collateral arteries were occluded spontaneously or by embolization in 60 (48%) of 124 patients. The endoleak rate was 50.9% (74 in 61 patients), most of which were type II (19%). Over a mean clinical follow-up of 60.5±34.1 months (range 1-144), aneurysm sac dimensions decreased in 66 patients, increased in 19 patients, and were stable in 35. The endoleak rate was significantly higher in the patients with increasing sac diameter (p<0.001). Among the patients with patent collateral arteries, 38/64 (59.3%) developed 46 leaks, while 28 leaks appeared in 23 (41%) of 56 patients with collateral artery occlusion (p=0.069). The type II endoleak rate significantly differed between these two groups (47.8% vs. 3.6%, p<0.001). CONCLUSION: Preoperative collateral embolization seems to be a valid method of reducing the incidence of type II endoleak, improving the long-term outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Primary venous aneurysm is a rare, but essential consideration in the differential diagnosis of an inguinal and femoral hernia. METHODS: We report a case of a 43-year-old man who was referred for evaluation and treatment of a femoral hernia. RESULTS: The patient presented with a 3-month history of an asymptomatic tumor on his right upper inner thigh. Physical examination noted a non-tender, non-indurated tumor. CONCLUSION: Surgical exploration demonstrated a primary venous aneurysm of the proximal saphenous vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Because of denervation supersensitivity, a miotic pupil in a sympathetically-denervated eye dilates in response to a dilute or weak alpha-1-agonist drug. A reversal of anisocoria after topical apraclonidine is considered as a positive test result that diagnoses a unilateral Horner syndrome. HISTORY AND SIGNS: Two women aged 34 and 46 years with a cocaine-confirmed oculosympathetic defect (Horner syndrome) were tested with 1 % topical apraclonidine on separate days. THERAPY AND OUTCOME: In one patient, her miotic Horner pupil dilated marginally but not enough to reverse the baseline anisocoria. Additionally, the upper lid on the same side retracted. There was no discernable effect of apraclonidine on the normal, contralateral eye. In the second patient, there was no pupillary response to apraclonidine but there was resolution of her ptosis. CONCLUSIONS: Neither patient demonstrated a reversal of anisocoria, the current criterion for diagnosing a Horner syndrome using apraclonidine. Thus, these two patients with an established oculosympathetic defect were said to have a "negative test" for Horner syndrome. Yet both women showed subtle pupil and/or lid changes in response to apraclonidine that were consistent with sympathetic denervation supersensitivity. Reversal of anisocoria following topical apraclonidine does not occur in all patients with a unilateral oculosympathetic defect and more specific parameters for defining a positive test result might optimize apraclonidine's utility as a diagnostic test for Horner syndrome

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Management of ischemic stroke in the presence of aneurysmal brain disease is controversial. Recent retrospective evidence suggests that in selected patients, intravenous thrombolysis (IVT) remains a safe approach for reperfusion. METHODS: We document a case of post-thrombolysis aneurysmal rupture. Supported by additional scientific literature we postulate that acute aneurysmal thrombosis leading to stroke in the culprit artery may be an ominous sign of rupture and should be considered separately from fortuitously discovered distant aneurysmal disease. RESULTS: A 71-year-old female presented with an acute right middle cerebral artery stroke syndrome. IVT allowed vessel reperfusion and revealed a previously concealed, juxtaposed non-giant M1 segment saccular aneurysm. Secondary aneurysmal rupture ensued. The aneurysm was secured by surgical clipping. Postoperative course was uneventful. CONCLUSIONS: This case shows that despite reports of thrombolysis safety in the presence of brain aneurysms, thrombolysis remains potentially hazardous and hints toward an increased risk when the stroke arises on the parent vessel itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-delà de la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a series of experiments on patient JB, a man with memory difficulties following damage to the left frontal lobe. The primary characteristic of JB's recognition memory impairment is a high level of false recognition together with a normal hit rate. The hypothesis that JB's false recognition reflects an over-reliance on familiarity is considered, but discounted on the basis that the false alarm rate is not affected by increasing the similarity between distracters and targets, and remains high when nonword stimuli are used. It is suggested, instead, that JB relies on a poorly focused memory description, which lacks item-specific detail but contains more general, low-level properties of the target items-these properties being held by many distracter items as well. This deficit is considered to arise because of damage to frontally mediated control processes involved in the selection of elements for memory encoding. An encoding deficit is supported by the fact that JB's false recognition is significantly reduced by orienting instructions, and is eliminated when his remote memory is subjected to recognition testing. In contrast, it is shown that manipulations at the level of retrieval (e.g. restricting the number of "old" responses) have little effect on his false recognition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

False identity documents constitute a potential powerful source of forensic intelligence because they are essential elements of transnational crime and provide cover for organized crime. In previous work, a systematic profiling method using false documents' visual features has been built within a forensic intelligence model. In the current study, the comparison process and metrics lying at the heart of this profiling method are described and evaluated. This evaluation takes advantage of 347 false identity documents of four different types seized in two countries whose sources were known to be common or different (following police investigations and dismantling of counterfeit factories). Intra-source and inter-sources variations were evaluated through the computation of more than 7500 similarity scores. The profiling method could thus be validated and its performance assessed using two complementary approaches to measuring type I and type II error rates: a binary classification and the computation of likelihood ratios. Very low error rates were measured across the four document types, demonstrating the validity and robustness of the method to link documents to a common source or to differentiate them. These results pave the way for an operational implementation of a systematic profiling process integrated in a developed forensic intelligence model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five years of experience with endovascular infrarenal aneurysm repair at our institution is reviewed. Implantation of endoprostheses in 88 patients has been performed by surgeons using exclusively intravascular ultrasound (IVUS) and fluoroscopy. IVUS identified the target site of deployment in all cases. In-hospital morbidity was 22% (19/88). Two percent mortality (2/88) and 5% early conversion (4/88) as a consequence of type I endoleaks were noted only in the first 53 patients with early devices (NS). Early endoleaks were present in 36% (32/88) including twenty-two type I, five type II and five type III endoleaks. Proximal endoleaks were associated with early devices (P<0.001), and technical difficulties with deployment. Tube grafts used in the beginning, performed poorly with 54% (7/13) type I endoleaks. Endoleaks diminished to 10% (9/88) by spontaneous closure and secondary endovascular procedures that were necessary in 24% (21/88) and consisted of coil embolization/cuff extension (9), late conversion (6), and limb recanalization or femoral cross-over bypass (6). Endovascular aneurysm repair using IVUS is a valid alternative technique. Improved devices and systematic use of bifurcated endoprostheses for infrarenal aneurysms reduce the occurrence of type I endoleaks.