957 resultados para Analyze space


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fentanyl is used in obstetrical practice to promote analgesia and anesthesia during labor and in cesarean delivery, with rapid and short-term effects. To determine fentanyl concentrations in maternal plasma, in the placental intervillous space, and in the umbilical artery and vein in term pregnant women. Ten healthy pregnant women underwent epidural anesthesia with fentanyl plus bupivacaine and lidocaine, and fentanyl concentrations were determined in the various maternal and fetal compartments, including the placental intervillous space, which has not been previously studied in the literature. The ratios of fentanyl concentrations in the various maternal and fetal compartments revealed an 86% rate of placental fentanyl transfer. The highest fentanyl concentrations were detected in the placental intervillous space, being 2.19 times higher than in maternal plasma, 2.8 times higher than in the umbilical vein and 3.6 times higher than in the umbilical artery, with no significant differences between the umbilical vein and artery, demonstrating that there was no drug uptake by fetal tissues nor metabolism of the drug by the fetus despite the high rates of placental transfer. The present study demonstrated that the placental intervillous space acted as a site of fentanyl deposit, a fact that may be explained by two hypotheses: (1) the blood collected from the placental intervillous space is arterial and, according to some investigators, the arterial plasma concentrations of the drugs administered to patients undergoing epidural anesthesia are higher than the venous concentrations, and (2) a possible role of P-glycoprotein (P-gp).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to determine the concentrations of lidocaine and its metabolite, monoethylglycine xylidide (MEGX), and of the enantiomers of bupivacaine in maternal and fetal compartments. Ten healthy pregnant women were submitted to epidural anesthesia. Drug concentrations were determined in the maternal vein, fetal umbilical artery and vein, and the placental intervillous space. The highest concentrations of the bupivacaine enantiomers lidocaine and of lidocaine and of its MEGX metabolite were detected in maternal plasma and in the placental intervillous space. The placental transfer was 33% for the (+)-(R)-bupivacaine enantiomer and 31% for the (-)-(S)-bupivacaine enantiomer. For lidocaine and its MEGX metabolite, respective placental transfers were 60% and 43%. Lidocaine concentration in the fetal umbilical vein was 1.46 times higher than in the fetal umbilical artery. The highest concentrations of lidocaine and its metabolite and of the enantiomers of bupivacaine were detected in the placental intervillous space. The higher lidocaine concentrations in the fetal umbilical vein than in the fetal umbilical artery suggest that there was tissue uptake of the drug or drug metabolization by the fetus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the effect of rapid maxillary expansion (RME) on the dimension of the nasopharyngeal space and its relation to nasal airway resistance. Methods: Twenty-five school-age children (from 7 to 10 year-old) with mouth and/or mixed breathing, with mixed dentition and uni- or bilateral posterior crossbite involving the deciduous canines and the first permanent molars, were evaluated. RME was placed and remained during 90 days. Rhinomanometry and orthodontic documentation were performed at four different times, i.e., before (T(1)), immediately after (T(2)), 90 days (T(3)) and 30 months (T(4)) after RME. Results: Differences in nasopharyngeal area and in nasal airway resistance were observed only 30 months after RME, and could be explained by facial growth, and not because of the orthodontic procedure. Conclusion: RME does not influence on nasopharyngeal area or nasal airway resistance in long-term evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Puncture of the atrial appendage may provide access to the pericardial space. The aim of this study was to evaluate the feasibility of epicardial mapping and ablation through an endocardial transatrial access in a swine model. Methods and Results-An 8-F Mullins sheath was used to perforate the right (n=16) or left (n=1) atrial appendage in 17 pigs (median weight, 27.5 kg; first and third quartiles [Q1, Q3], 25.2, 30.0 kg). A 7-F ablation catheter was introduced into the pericardial space to perform epicardial mapping and deliver radiofrequency pulses on the atria. The pericardial space was entered in all 17 animals. In 15 (88%) animals, there was no hemodynamic instability (mean blood pressure monitoring, initial median, 80 mm Hg; Q1, Q3, 70, 86 mm Hg; final median, 88 mm Hg; Q1, Q3, 80, 96 mm Hg; P=0.426). In these 15, a mild hemorrhagic pericardial effusion was identified and aspirated (median, 20 mL; Q1, Q3, 15, 30 mL) during the procedure, and postmortem gross analysis revealed that the atrial perforation was closed in these animals. In 2 (12%) of the 17 animals, there was major pericardial bleeding with hemodynamic collapse. On gross examination, it was found that pericardial space was accessed through right ventricular perforation in 1 animal and the tricuspid annulus in the other. After the initial study, we used an occlusion device in 3 other animals to attempt to seal the puncture (2 at the right atrial appendage and 1 at the right ventricle). These 3 animals had no significant pericardial bleeding. Conclusions-Transatrial endovascular right atrial appendage puncture may provide a potential alternative route for pericardial access. Further studies are needed to evaluate its safety with longer and more-complex procedures before being applied in clinical settings. (Circ Arrhythm Electrophysiol. 2011;4:331-336.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To analyze the microhardness of four dual-cure resin cements used for cementing fiber-reinforced posts under the following conditions: after 7 days of storage in water, after additional 24 h of immersion in 75% ethanol, and after 3 months of storage in water. Hardness measurements were taken at the cervical, middle and apical thirds along the cement line. Methods. Root canals of 40 bovine incisors were prepared for post space. Fibrekor (R) glass fiber-reinforced posts (Jeneric/Pentron) of 1 mm in diameter were cemented using Panavia F 2.0 (Kuraray), Variolink (Ivoclar-Vivadent), Rely X Unicem (3M ESPE) or Duolink (Bisco) (N = 10). After 7 days of water storage at 37 degrees C, half the sample (N = 5) was longitudinally sectioned and the initial microhardness measured along the cement line from cervical to apex. These same samples were further immersed in 75% ethanol for 24 h and reassessed. The remaining half (N = 5) was kept unsectioned in deionized water at 37 degrees C for 3 months, followed by sectioning and measuring. Data were analyzed by a series of two-way ANOVA and Tukey tests at alpha = 5%. Results. Statistically significant differences were identified among the cements, thirds and conditions. Significant interactions were also observed between cements and thirds and between cements and conditions. Panavia F exhibited significantly higher initial microhardness than the other three cements, which showed no statistical difference among themselves. Variolink and Duolink showed significantly higher microhardness values in the cervical third, without significant difference among the thirds for the other cements. Immersion in ethanol significantly reduced the hardness values for all cements, regardless of the thirds. Storage in water for 3 months had no influence on the hardness of most of the cements, with the exception of Unicem that showed a significant increase in the hardness values after this period. Results showed heterogeneity in the microhardness of the cements inside the canal. All cements presented some degree of softening after ethanol treatment, which suggests instability of the polymer. The quality of curing of resin cements in the root canal environment seems unpredictable and highly material dependent. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the cement thickness around oval and circular posts luted in oval post spaces prepared with different drills/tips. Methods: Extracted premolars were endodontically treated and obturated, then randomly divided into three groups (n = 5) according to the tips/drills used for post-space preparation and to the type of fiber post luted: medium grit oval tip + oval posts, fine grit oval tip + oval posts, Mtwo Post File drill + circular posts. The specimens were sectioned in horizontal slices; one slice per canal third was chosen for each post-space, resulting in three slices for each specimen. The distances between the canal wall and the post perimeter were measured on SEM images of each slice. Results: The fine grit tip + oval post group obtained statistically significant lower cement thicknesses than the other groups (P < 0.05), in particular in the apical third. The MtwoPF + circular post group showed the highest cement thickness, comparable to that of the medium tip + oval post group. A good post fitting in oval-shaped canals can be obtained using a fine grit oval tip combined with oval posts. (Am J Dent 2009;22:290-294).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluates the effect on post space debridement in oval-shaped canals of an experimental ultrasonic tip with oval section (Satelec) compared with a circular ultrasonic tip (KaVo). Thirty teeth with an oval-shaped canal were endodontically treated and obturated and then randomly divided into 3 groups (n = 10) according to the procedure used for post space debridement: Satelec tip, Largo #2 drill + KaVo file, and Largo #2 drill + water. Debris and dentin tubules were evaluated by assigning scores to scanning electron microscope post spaces images; lower scores corresponded to fewer debris and higher number of open tubules. The Satelec group showed significantly lower debris and open tubules scores than KaVo group (p < .05) and control group (p < .05), which differed significantly between each other (p < .05). Also the debris and open tubules scores in different post space regions differed significantly among the experimental groups (p < .001). The oval ultrasonic tip resulted in a better post space debridement than a circular ultrasonic tip in oval-shaped canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the effect of two drills and five cleaning regimens on post space debridement. One hundred extracted premolars were instrumented and obturated with warm vertical compaction of gutta percha. The teeth were divided into two groups according to the drill used to remove gutta percha/sealer and for post space preparation: a Largo drill (Largo; Dentsply, St Quentin en Yvelines, France) or a MTwo-PF drill (Sweden&Martina, Due Carrare, Padova, Italy). The following cleaning regimens were used: EDTA, ultrasonics, ultrasonics + EDTA, phosphoric acid, and distilled water. Scanning electron microscopic images of the post spaces were taken, and the presence of debris and of open dentin tubules were evaluated. The ultrasonics + EDTA, phosphoric acid, and EDTA groups were comparable in open tubules scores for both drills and in debris scores after the use of MTwo-PF (p > 0.05). The ultrasonics and control groups performed significantly worse (p < 0.05). The MTwo-PF drill resulted as effective as the Largo drill in obtaining a good post space cleaning, especially when followed by ultrasonics + EDTA irrigant regimen.

Relevância:

20.00% 20.00%

Publicador: