977 resultados para Air passenger seat capacity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During autumn 2003, several thousand European starlings (Sturnus vulgaris) began roosting on exposed I-beams in a newly constructed, decorative glass canopy that covered the passenger pick-up area at the terminal building for Cleveland Hopkins International Airport, Ohio. The use of lethal control or conventional dispersal techniques, such as pyrotechnics and fire hoses, were not feasible in the airport terminal area. The design and aesthetics of the structure precluded the use of netting and other exclusion materials. In January 2004, an attempt was made to disperse the birds using recorded predator and distress calls broadcast from speakers installed in the structure. This technique failed to disperse the birds. In February 2004, we developed a technique using compressed air to physically and audibly harass the birds. We used a trailer-mounted commercial air compressor producing 185 cubic feet per minute of air at 100 pounds per square inch pressure and a 20-foot long, 1-inch diameter PVC pipe attached to the outlet hose. One person slowly (< 5 mph) drove a pick-up truck through the airport terminal at dusk while the second person sat on a bench in the truck bed and directed the compressed air from the pipe into the canopy to harass starlings attempting to enter the roost site. After 5 consecutive nights of compressed-air harassment, virtually no starlings attempted to roost in the canopy. Once familiar with the physical effects of the compressed air, the birds dispersed at the sound of the air. Only occasional harassment at dusk was needed through the remainder of the winter to keep the canopy free of starlings. Similar harassment with the compressor was conducted successfully in autumn 2004 with the addition of a modified leaf blower, wooden clappers, and laser. In conclusion, we found compressed air to be a safe, unobtrusive, and effective method for dispersing starlings from an urban roost site. This technique would likely be applicable for other urban-roosting species such as crows, house sparrows, and blackbirds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RAMOS RT, MATTOS DA, REBOUCAS ITS, RANVAUD RD. Space and motion perception and discomfort in air travel. Aviat Space Environ Med 2012; 83:1162-6. Introduction: The perception of comfort during air trips is determined by several factors. External factors like cabin design and environmental parameters (temperature, humidity, air pressure, noise, and vibration) interact with individual characteristics (anxiety traits, fear of flying, and personality) from arrival at the airport to landing at the destination. In this study, we investigated the influence of space and motion discomfort (SMD), fear of heights, and anxiety on comfort perception during all phases of air travel. Methods: We evaluated 51 frequent air travelers through a modified version of the Flight Anxiety Situations Questionnaire (FAS), in which new items were added and where the subjects were asked to report their level of discomfort or anxiety (not fear) for each phase of air travel (Chronbach's alpha = 0.974). Correlations were investigated among these scales: State-Trait Anxiety Inventory (STAB, Cohen's Acrophobia Questionnaire, and the Situational Characteristics Questionnaire (SitQ, designed to estimate SMD levels). Results: Scores of SitQ correlated with discomfort in situations involving space and movement perception (Pearson's rho = 0.311), while discomfort was associated with cognitive mechanisms related to scores in the anxiety scales (Pearson's rho = 0.375). Anxiety traits were important determinants of comfort perception before and after flight, while the influence of SMD was more significant during the time spent in the aircraft cabin. Discussion: SMD seems to be an important modulator of comfort perception in air travel. Its influence on physical well being and probably on cognitive performance, with possible effects on flight safety, deserves further investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN] Hypoxia-induced hyperventilation is critical to improve blood oxygenation, particularly when the arterial Po2 lies in the steep region of the O2 dissociation curve of the hemoglobin (ODC). Hyperventilation increases alveolar Po2 and, by increasing pH, left shifts the ODC, increasing arterial saturation (Sao2) 6 to 12 percentage units. Pulmonary gas exchange (PGE) is efficient at rest and, hence, the alveolar-arterial Po2 difference (Pao2-Pao2) remains close to 0 to 5mm Hg. The (Pao2-Pao2) increases with exercise duration and intensity and the level of hypoxia. During exercise in hypoxia, diffusion limitation explains most of the additional Pao2-Pao2. With altitude, acclimatization exercise (Pao2-Pao2) is reduced, but does not reach the low values observed in high altitude natives, who possess an exceptionally high DLo2. Convective O2 transport depends on arterial O2 content (Cao2), cardiac output (Q), and muscle blood flow (LBF). During whole-body exercise in severe acute hypoxia and in chronic hypoxia, peak Q and LBF are blunted, contributing to the limitation of maximal oxygen uptake (Vo2max). During small-muscle exercise in hypoxia, PGE is less perturbed, Cao2 is higher, and peak Q and LBF achieve values similar to normoxia. Although the Po2 gradient driving O2 diffusion into the muscles is reduced in hypoxia, similar levels of muscle O2 diffusion are observed during small-mass exercise in chronic hypoxia and in normoxia, indicating that humans have a functional reserve in muscle O2 diffusing capacity, which is likely utilized during exercise in hypoxia. In summary, hypoxia reduces Vo2max because it limits O2 diffusion in the lung.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The subject of this thesis is the development of a Gaschromatography (GC) system for non-methane hydrocarbons (NMHCs) and measurement of samples within the project CARIBIC (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container, www.caribic-atmospheric.com). Air samples collected at cruising altitude from the upper troposphere and lowermost stratosphere contain hydrocarbons at low levels (ppt range), which imposes substantial demands on detection limits. Full automation enabled to maintain constant conditions during the sample processing and analyses. Additionally, automation allows overnight operation thus saving time. A gas chromatography using flame ionization detection (FID) together with the dual column approach enables simultaneous detection with almost equal carbon atom response for all hydrocarbons except for ethyne. The first part of this thesis presents the technical descriptions of individual parts of the analytical system. Apart from the sample treatment and calibration procedures, the sample collector is described. The second part deals with analytical performance of the GC system by discussing tests that had been made. Finally, results for measurement flight are assessed in terms of quality of the data and two flights are discussed in detail. Analytical performance is characterized using detection limits for each compound, using uncertainties for each compound, using tests of calibration mixture conditioning and carbon dioxide trap to find out their influence on analyses, and finally by comparing the responses of calibrated substances during period when analyses of the flights were made. Comparison of both systems shows good agreement. However, because of insufficient capacity of the CO2 trap the signal of one column was suppressed due to breakthroughed carbon dioxide so much that its results appeared to be unreliable. Plausibility tests for the internal consistency of the given data sets are based on common patterns exhibited by tropospheric NMHCs. All tests show that samples from the first flights do not comply with the expected pattern. Additionally, detected alkene artefacts suggest potential problems with storing or contamination within all measurement flights. Two last flights # 130-133 and # 166-169 comply with the tests therefore their detailed analysis is made. Samples were analyzed in terms of their origin (troposphere vs. stratosphere, backward trajectories), their aging (NMHCs ratios) and detected plumes were compared to chemical signatures of Asian outflows. In the last chapter a future development of the presented system with focus on separation is drawn. An extensive appendix documents all important aspects of the dissertation from theoretical introduction through illustration of sample treatment to overview diagrams for the measured flights.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Das wichtigste Oxidationsmittel für den Abbau flüchtiger Kohlenwasserstoffverbindungen (VOC, engl.: volatile organic compounds) in der Atmosphäre ist das Hydroxylradikal (OH), welches sich in einem schnellen chemischen Gleichgewicht mit dem Hydroperoxylradical (HO2) befindet. Bisherige Messungen und Modellvergleiche dieser Radikalspezies in Waldgebieten haben signifikante Lücken im Verständnis der zugrundeliegenden Prozesse aufgezeigt.rnIm Rahmen dieser Doktorarbeit wurden Messungen von OH- und HO2-Radikalen mittelsrnlaserinduzierten Fluoreszensmesstechnik (LIF, engl.: laser-induced fluorescence) in einem Nadelwald in Süd-Finnland während der Messkampagne HUMPPA–COPEC–2010 (Hyytiälä United Measurements of Photochemistry and Particles in Air – Comprehensive Organic Precursor Emission and Concentration study) im Sommer 2010 durchgeführt. Unterschiedliche Komponenten des LIF-Instruments wurden verbessert. Eine modifizierte Methode zur Bestimmung des Hintergrundsignals (engl.: InletPreInjector technique) wurde in den Messaufbaurnintegriert und erstmals zur Messung von atmosphärischem OH verwendet. Vergleichsmessungen zweier Instrumente basierend auf unterschiedlichen Methoden zur Messung von OH-Radikalen, chemische Ionisationsmassenspektrometrie (CIMS - engl.: chemical ionization mass spectrometry) und LIF-Technik, zeigten eine gute Übereinstimmung. Die Vergleichsmessungen belegen das Vermögen und die Leistungsfähigkeit des modifizierten LIF-Instruments atmosphärische OH Konzentrationen akkurat zu messen. Nachfolgend wurde das LIF-Instrument auf der obersten Plattform eines 20m hohen Turmes positioniert, um knapp oberhalb der Baumkronen die Radikal-Chemie an der Schnittstelle zwischen Ökosystem und Atmosphäre zu untersuchen. Umfangreiche Messungen - dies beinhaltet Messungen der totalen OH-Reaktivität - wurden durchgeführt und unter Verwendung von Gleichgewichtszustandsberechnungen und einem Boxmodell, in welches die gemessenen Daten als Randbedingungen eingehen, analysiert. Wenn moderate OH-Reaktivitäten(k′(OH)≤ 15 s−1) vorlagen, sind OH-Produktionsraten, die aus gemessenen Konzentrationen von OH-Vorläuferspezies berechnet wurden, konsistent mit Produktionsraten, die unter der Gleichgewichtsannahme von Messungen des totalen OH Verlustes abgeleitet wurden. Die primären photolytischen OH-Quellen tragen mit einem Anteil von bis zu einem Drittel zur Gesamt-OH-Produktion bei. Es wurde gezeigt, dass OH-Rezyklierung unter Bedingungen moderater OH-Reaktivität hauptsächlich durch die Reaktionen von HO2 mit NO oder O3 bestimmt ist. Während Zeiten hoher OH-Reaktivität (k′(OH) > 15 s−1) wurden zusätzliche Rezyklierungspfade, die nicht über die Reaktionen von HO2 mit NO oder O3, sondern direkt OH bilden, aufgezeigt.rnFür Hydroxylradikale stimmen Boxmodell-Simulationen und Messungen gut übereinrn(OHmod/OHobs=1.04±0.16), während HO2-Mischungsverhältnisse in der Simulation signifikant unterschätzt werden (HO2mod/HO2obs=0.3±0.2) und die simulierte OH-Reaktivität nicht mit der gemessenen OH-Reaktivität übereinstimmt. Die gleichzeitige Unterschätzung der HO2-Mischungsverhältnisse und der OH-Reaktivität, während OH-Konzentrationen von der Simulation gut beschrieben werden, legt nahe, dass die fehlende OH-Reaktivität in der Simulation eine noch unberücksichtigte HO2-Quelle darstellt. Zusätzliche, OH-unabhängigernRO2/HO2-Quellen, wie z.B. der thermische Zerfall von herantransportiertem peroxyacetylnitrat (PAN) und die Photolyse von Glyoxal sind indiziert.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today the use of concrete ties is on the rise in North America as they become an economically competitive alternative to the historical industry standard wood ties, while providing performance which exceeds its competition in terms of durability and capacity. Similarly, in response to rising energy costs, there is increased demand for efficient and sustainable transportation of people and goods. One source of such transportation is the railroad. To accommodate the increased demand, railroads are constructing new track and upgrading existing track. This update to the track system will increase its capacity while making it a more reliable means of transportation compared to other alternatives. In addition to increasing the track system capacity, railroads are considering an increase in the size of the typical freight rail car to allow larger tonnage. An increase in rail car loads will in turn affect the performance requirements of the track. Due to the increased loads heavy haul railroads are considering applying to their tracks, current designs of prestressed concrete railroad ties for heavy haul applications may be undersized. In an effort to maximize tie capacity while maintaining tie geometry, fastening systems and installation equipment, a parametric study to optimize the existing designs was completed. The optimization focused on maximizing the capacity of an existing tie design through an investigation of prestressing quantity, configuration, stress levels and other material properties. The results of the parametric optimization indicate that the capacity of an existing tie can be increased most efficiently by increasing the diameter of the prestressing and concrete strength. However, researchers also found that current design specifications and procedures do not include consideration of tie behavior beyond the current tie capacity limit of cracking to the first layer of prestressing. In addition to limiting analysis to the cracking limit, failure mechanisms such as shear in deep beams at the rail seat or pullout failure of the prestressing due to lack of development length were absent from specified design procedures, but discussed in this project.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study will look at the passenger air bag (PAB) performance in a fix vehicle environment using Partial Low Risk Deployment (PLRD) as a strategy. This development will follow test methods against actual baseline vehicle data and Federal Motor Vehicle Safety Standards 208 (FMVSS 208). FMVSS 208 states that PAB compliance in vehicle crash testing can be met using one of three deployment methods. The primary method suppresses PAB deployment, with the use of a seat weight sensor or occupant classification sensor (OCS), for three-year old and six-year old occupants including the presence of a child seat. A second method, PLRD allows deployment on all size occupants suppressing only for the presents of a child seat. A third method is Low Risk Deployment (LRD) which allows PAB deployment in all conditions, all statures including any/all child seats. This study outlines a PLRD development solution for achieving FMVSS 208 performance. The results of this study should provide an option for system implementation including opportunities for system efficiency and other considerations. The objective is to achieve performance levels similar too or incrementally better than the baseline vehicles National Crash Assessment Program (NCAP) Star rating. In addition, to define systemic flexibility where restraint features can be added or removed while improving occupant performance consistency to the baseline. A certified vehicles’ air bag system will typically remain in production until the vehicle platform is redesigned. The strategy to enable the PLRD hypothesis will be to first match the baseline out of position occupant performance (OOP) for the three and six-year old requirements. Second, improve the 35mph belted 5th percentile female NCAP star rating over the baseline vehicle. Third establish an equivalent FMVSS 208 certification for the 25mph unbelted 50th percentile male. FMVSS 208 high-speed requirement defines the federal minimum crash performance required for meeting frontal vehicle crash-test compliance. The intent of NCAP 5-Star rating is to provide the consumer with information about crash protection, beyond what is required by federal law. In this study, two vehicles segments were used for testing to compare and contrast to their baseline vehicles performance. Case Study 1 (CS1) used a cross over vehicle platform and Case Study 2 (CS2) used a small vehicle segment platform as their baselines. In each case study, the restraints systems were from different restraint supplier manufactures and each case contained that suppliers approach to PLRD. CS1 incorporated a downsized twins shaped bag, a carryover inflator, standard vents, and a strategic positioned bag diffuser to help disperse the flow of gas to improve OOP. The twin shaped bag with two segregated sections (lobes) to enabled high-speed baseline performance correlation on the HYGE Sled. CS2 used an A-Symmetric (square shape) PAB with standard size vents, including a passive vent, to obtain OOP similar to the baseline. The A-Symmetric shape bag also helped to enabled high-speed baseline performance improvements in HYGE Sled testing in CS2. The anticipated CS1 baseline vehicle-pulse-index (VPI) target was in the range of 65-67. However, actual dynamic vehicle (barrier) testing was overshadowed with the highest crash pulse from the previous tested vehicles with a VPI of 71. The result from the 35mph NCAP Barrier test was a solid 4-Star (4.7 Star) respectfully. In CS2, the vehicle HYGE Sled development VPI range, from the baseline was 61-62 respectively. Actual NCAP test produced a chest deflection result of 26mm versus the anticipated baseline target of 12mm. The initial assessment of this condition was thought to be due to the vehicles significant VPI increase to 67. A subsequent root cause investigation confirmed a data integrity issue due to the instrumentation. In an effort to establish a true vehicle test data point a second NCAP test was performed but faced similar instrumentation issues. As a result, the chest deflect hit the target of 12.1mm; however a femur load spike, similar to the baseline, now skewed the results. With noted level of performance improvement in chest deflection, the NCAP star was assessed as directional for 5-Star capable performance. With an actual rating of 3-Star due to instrumentation, using data extrapolation raised the ratings to 5-Star. In both cases, no structural changes were made to the surrogate vehicle and the results in each case matched their perspective baseline vehicle platforms. These results proved the PLRD is viable for further development and production implementation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The airliner cabin environment and its effects on occupant health have not been fully characterized. This dissertation is: (1) A review of airliner environmental control systems (ECSs) that modulate the ventilation, temperature, relative humidity (RH), and barometric pressure (PB) of the cabin environment---variables related to occupant comfort and health. (2) A review and assessment of the methods and findings of key cabin air quality (CAQ) investigations. Several significant deficiencies impede the drawing of inferences about CAQ, e.g., lack of detail about investigative methods, differences in methods between investigations, limited assessment of CAQ variables, small sample sizes, and technological deficiencies of data collection. (3) A comprehensive evaluation of the methods used in the subsequent NIOSH-FAA Airliner CAQ Exposure Assessment Feasibility Study (STUDY) in which this author participated. A number of problems were identified which limit the usefulness of the data. (4) An analysis of the reliable 10-flight STUDY data. Univariate and multivariate methods applied to CO2 (a surrogate for air contaminants), temperature, RH, and PB, in association with percent passenger load, ventilation system, flight duration, airliner body type, and measurement location within the cabin, revealed neither the measured values nor their variability exceeded established health-based exposure limits. Regression analyses suggest CO2, temperature, and RH were affected by percent passenger load. In-flight measurements of CO2 and RH were relatively independent of ventilation system type or flight duration. Cabin temperature was associated with percent passenger load, ventilation system type, and flight duration. (5) A synthesis of the implications of the airliner ECS and cabin O2 environment on occupant health. A model was developed to predict consequences of the airliner cabin pressure altitude 8,000 ft limit and resulting model-estimated PO2 on cardiopulmonary status. Based on the PB, altitude, and environmental data derived from the 10 STUDY flights, the predicted PaO2 of adults with COPD, or elderly adults with or without COPD, breathing ambient cabin air could be < 55 mm Hg (SaO2 < 88%). Reduction in cabin PB found in the STUDY flights could aggravate various medical conditions and require the use of in-flight supplemental O2. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study examines sublethal effects of near-future (year 2100) ocean acidification (OA) on regenerative capacity, biochemical composition, and behavior of the sea star Luidia clathrata, a predominant predator in sub-tropical soft-bottom habitats. Two groups of sea stars, each with two arms excised, were maintained on a formulated diet in seawater bubbled with air alone (pH 8.2, approximating a pCO2 of 380 µatm) or with a controlled mixture of air/C02 (pH 7.8, approximating a pCO2 of 780 µatm). Arm length, total body wet weight, and righting responses were measured weekly. After 97 days, a period of time sufficient for 80% arm regeneration, pyloric caecal indices, and protein, carbohydrate, lipid, and ash levels were determined for body wall and pyloric caecal tissues of intact and regenerating arms of individuals held in both seawater pH treatments. The present study indicates that predicted near-term levels of ocean acidification (seawater pH 7.8) do not significantly impact whole animal growth, arm regeneration rates, biochemical composition, or righting behavior in this common soft bottom sea star.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ocean acidification is expected to lower the net accretion of coral reefs yet little is known about its effect on coral photophysiology. This study investigated the effect of increasing CO2 on photosynthetic capacity and photoprotection in Acropora formosa. The photoprotective role of photorespiration within dinoflagellates (genus Symbiodinium) has largely been overlooked due to focus on the presence of a carbon-concentrating mechanism despite the evolutionary persistence of a Form II Rubisco. The photorespiratory fixation of oxygen produces phosphoglycolate that would otherwise inhibit carbon fixation though the Calvin cycle if it were not converted to glycolate by phosphoglycolate phosphatase (PGPase). Glycolate is then either excreted or dealt with by enzymes in the photorespiratory glycolate and/or glycerate pathways adding to the pool of carbon fixed in photosynthesis. We found that CO2 enrichment led to enhanced photoacclimation (increased chlorophyll a per cell) to the subsaturating light levels. Light-enhanced dark respiration per cell and xanthophyll de-epoxidation increased, with resultant decreases in photosynthetic capacity (Pnmax) per chlorophyll. The conservative CO2 emission scenario (A1B; 600-790 ppm) led to a 38% increase in the Pnmax per cell whereas the 'business-as-usual' scenario (A1F1; 1160-1500 ppm) led to a 45% reduction in PGPase expression and no change in Pnmax per cell. These findings support an important functional role for PGPase in dinoflagellates that is potentially compromised under CO2 enrichment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increase in atmospheric CO2 due to anthropogenic activity results in an acidification of the surface waters of the oceans. The impact of these chemical changes depends on the considered organisms. In particular, it depends on the ability of the organism to control the pH of its inner fluids. Among echinoderms, this ability seems to differ significantly according to species or taxa. In the present paper, we investigated the buffer capacity of the coelomic fluid in different echinoderm taxa as well as factors modifying this capacity. Euechinoidea (sea urchins except Cidaroidea) present a very high buffer capacity of the coelomic fluid (from 0.8 to 1.8 mmol/kg SW above that of seawater), while Cidaroidea (other sea urchins), starfish and holothurians have a significantly lower one (from -0.1 to 0.4 mmol/kg SW compared to seawater). We hypothesize that this is linked to the more efficient gas exchange structures present in the three last taxa, whereas Euechinoidea evolved specific buffer systems to compensate lower gas exchange abilities. The constituents of the buffer capacity and the factors influencing it were investigated in the sea urchin Paracentrotus lividus and the starfish Asterias rubens. Buffer capacity is primarily due to the bicarbonate buffer system of seawater (representing about 63% for sea urchins and 92% for starfish). It is also partly due to coelomocytes present in the coelomic fluid (around 8% for both) and, in P. lividus only, a compound of an apparent size larger than 3 kDa is involved (about 15%). Feeding increased the buffer capacity in P. lividus (to a difference with seawater of about 2.3 mmol/kg SW compared to unfed ones who showed a difference of about 0.5 mmol/kg SW) but not in A. rubens (difference with seawater of about 0.2 for both conditions). In P. lividus, decreased seawater pH induced an increase of the buffer capacity of individuals maintained at pH 7.7 to about twice that of the control individuals and, for those at pH 7.4, about three times. This allowed a partial compensation of the coelomic fluid pH for individuals maintained at pH 7.7 but not for those at pH 7.4.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Changes in seawater pH, temperature and salinity are expected to occur in the near future, which can be a threat to aquatic systems, mainly for marine coastal areas, and their inhabiting species. Hence, the present study proposes to evaluate the effects of temperature shifts, pH decrease and salinity changes in the tissue's regenerative capacity of the polychaete Diopatra neapolitana. This study evidenced that D. neapolitana individuals exposed to lower pH exhibited a significantly lower capacity to regenerate their body, while with the increase of temperature individuals showed a higher capacity to regenerate their tissues. Furthermore, the present work demonstrated that individuals exposed to salinities 28 and 35 did not present significant differences between them, while salinities 21 and 42 negatively influenced the regenerative capacity of D. neapolitana. At the end of regeneration, comparing all conditions, high salinity (42) seemed to have a greater impact on the regenerative capacity of individuals than the other factors, since under this condition individuals took longer to completely regenerate. Overall, this study demonstrated that variations in abiotic factors can strongly affect D. neapolitana's performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims to identify the magnitude of energy efficiency improvement, which has been promoted through energy efficiency labeling and the Minimum Energy Performance Standard, and to compare this against the increase in the number of products and the average increase in cooling capacity. Air conditioners (ACs) are one of the major contributors to energy consumption in a household. To assess the magnitude of this factor, we developed a formula to decompose total energy consumption from ACs into the number of ACs, their average cooling capacity, and energy efficiency. In the case of ACs in Thailand, energy efficiency improvement has offset the increase in the average AC cooling capacity. However, energy consumption from ACs increases with the number of ACs.