897 resultados para Air in literature


Relevância:

100.00% 100.00%

Publicador:

Resumo:

XAFS (EXAFS and XANES) at Eu-L-3 edge were used to determine the local structure and the valences of europium in CaBPO5:Eu prepared in air. The results of EXAFS showed that the doped europium atoms were nine-coordinated by oxygen atoms and the distances of bond Eu-O were 2.39 Angstrom in the host lattice. XANES at Eu-L-3 edge exhibited that Eu2+ and Eu3+ coexisted in the matrix. The luminescent spectrum of the material excited by VUV at 147 nm presented a similar spectrum with that excited by f-f transition of Eu2+ at 396 nm and f-d transition of Eu2+ at 312 nm. The broad emission band due to both 4f(6)5d - 4f(7) transition of EU2+ and f - f transition of Eu3+ could be observed in emission spectra, which indicated that the trivalent europium ions were reduced in air in the matrix at high temperature by the defects [V-Cn]" formed by aliovalent substitution between Ca2+ and Eu3+ ions. The UV excitation spectrum showed the typical f-f transition of Eu3+ and f-d transition of Eu2+. The bands with the maxima at about 113 and 158 nm in VUV excitation spectrum were assigned to originate from the absorption of the host lattice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In most applications helium-based plasma jets operate in an open-air environment. The presence of humid air in the plasma jet will influence the plasma chemistry and can lead to the production of a broader range of reactive species. We explore the influence of humid air on the reactive species in radio frequency (rf)-driven atmospheric-pressure helium-oxygen mixture plasmas (He-O, helium with 5000 ppm admixture of oxygen) for wide air impurity levels of 0-500 ppm with relative humidities of from 0% to 100% using a zero-dimensional, time-dependent global model. Comparisons are made with experimental measurements in an rf-driven micro-scale atmospheric pressure plasma jet and with one-dimensional semi-kinetic simulations of the same plasma jet. These suggest that the plausible air impurity level is not more than hundreds of ppm in such systems. The evolution of species concentration is described for reactive oxygen species, metastable species, radical species and positively and negatively charged ions (and their clusters). Effects of the air impurity containing water humidity on electronegativity and overall plasma reactivity are clarified with particular emphasis on reactive oxygen species. © 2013 IOP Publishing Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Memory Mixed with Desire: A preliminary study of Philosophy and Literature in the works of Friedrich Nietzsche and Milan Kundera Robert Spinelli Brock University, Department of Philosophy This thesis studies intertextuality in the works of Friedrich Nietzsche and Milan Kundera through the primary themes of memory and forgetting. The thesis starts with two introductory chapters that delineate memory according to Nietzsche and Kundera respectively. From here, I move into a discussion of Nietzsche's Ubermensch as an example of the type of forgetting that Nietzsche sees as a cure for the overabundance of memory that has led to Christian morality. Next, I explore the Kunderan concept of kitsch as the polar opposite of what Nietzsche has sought in his philosophy, finishing the chapter by tying the two thinkers together in a Kunderan critique of Nietzsche. The thesis ends with a chapter devoted to the Eternal Return beginning with an exegesis of Nietzsche's idea and ending with a similar exegesis of Kundera's treatment of this thought. What I suggest in this chapter is that the Eternal Return might itself be a form of kitsch even in its attempt to revalue existence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le benzo-a-pyrène (BaP) est un cancérogène reconnu pour l'homme, contaminant présent dans notre environnement. Il cause des dommages à l'ADN que nous avons mesurés dans les lymphocytes exposés à de faibles concentrations de BaP, provenant de 20 jeunes volontaires non fumeurs et en santé. Suite à l’exposition, la fréquence des micronoyaux (MN) augmente significativement et décrit une courbe dose-réponse non linéaire, suggérant le déclenchement du processus de détoxification et la réparation de l’ADN. Des différences entre les individus et entre les sexes sont présentes dans la réponse génotoxique produite par le BaP. Le test des aberrations chromosomiques montre que le pourcentage de chromosomes cassés augmente significativement dans les cellules exposées au BaP. Combinés avec l'augmentation de la fréquence des MN, nos résultats confirment l'effet clastogène du BaP déjà rapporté dans la littérature. L’hybridation in situ en fluorescence (FISH) des MN avec une sonde pancentromérique est aussi utilisée pour établir leur mécanisme de formation. La FISH révèle que la majorité des MN formés après une exposition au BaP contient un centromère et plus, ce qui est significativement différent de la condition non exposée. Plus précisément, dans nos conditions expérimentales, les MN induits par le BaP contiennent surtout trois centromères et plus, indiquant également la présence d'un effet aneugène. L'effet clastogène du BaP est relié à son rôle d'initiateur dans la cancérogenèse, alors que l'effet aneugène le relierait à l'étape de progression. Ces résultats sont importants puisque l'exposition aux composés de la classe du BaP est de longue durée (cigarette, air pollué).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. II, Reading, UK, 2000. p. 1013-18; [13] Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive feature of the system is its full utilization of cooling capacity and freshness of outdoor air in the transition period of the year round. On the basis of the obtain of the dynamic cooling loads of the typical shopping malls in different four cities located in cold climates in China with the aid of DOE-2, the possibility of increasing the amount of outdoor air volume of CVAV system in the transition period instead of operating the water chillers was confirmed. Moreover, a new concept, Direct Outdoor Air Cooling Efficiency (DOACE), was defined as the ratio of cooling capacity of outdoor air to the water chiller, indicating the degree of outdoor air’s utilization. And the DOACE of the CVAV was calculated and compared with that of conventional all-air constant volume air-conditioning systems, the results showed that CVAV bear much more energy saving potential with the 10%~19% higher DOACE and it is a kind of energy efficient systems and can improve the indoor air quality as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cultura da batata possui grande expressão econômica dentro do cenário agrícola. Para isso, equipamentos e técnicas de aplicação de produtos fitossanitários vêm sendo desenvolvidos visando melhorar o rendimento econômico da cultura. Neste sentido, experimentos foram conduzidos no delineamento em blocos ao acaso na cultura da batata cv. Ágata. Objetivando avaliar o efeito da assistência de ar combinada a diferentes ângulos de aplicação sobre a deposição da pulverização, bem como as perdas da calda para o solo utilizou-se um pulverizador com e sem assistência de ar junto à barra de pulverização posicionada a +30º, 0º e -30º (sinal + a favor e - contrário ao deslocamento) em relação a vertical. O volume de calda foi 400 L ha-1 utilizando-se pontas de jato cônico vazio JA-4 na pressão de 633 kPa. Para a avaliação dos depósitos utilizou-se um traçador cúprico. Os depósitos foram removidos dos folíolos por lavagem com água destilada, em ambas as superfícies foliares, nas posições superior e inferior das plantas de batata e quantificados por espectrofotometria de absorção atômica. As perdas da pulverização foram avaliadas em coletores plásticos colocados nas entrelinhas das parcelas experimentais. Os níveis dos depósitos do traçador cúprico nas diferentes posições da planta foram analisados pelo teste estatístico T² de Hotteling. Os maiores depósitos foram obtidos com a barra posicionada a 0º e +30º, em presença da assistência de ar, tanto na posição superior quanto inferior da planta. A presença do ar, além de propiciar maiores depósitos na parte inferior das plantas, possibilitou maior uniformidade na distribuição deles. As perdas da pulverização ficaram abaixo de 4%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was conducted to determine the effect of the air temperature variation on the mean surface temperature (MST) of 7-to 35-day-old broiler chickens using infrared thermometry to estimate MST, and to study surface temperature variation of the wings, head, legs, back and comb as affected by air temperature and broiler age. One hundred Cobb(R) broilers were used in the experiment. Starting on day 7, 10 birds were weekly selected at random, housed in an environmental chamber and reared under three distinct temperatures (18, 25 and 32 degrees C) to record their thermal profile using an infrared thermal camera. The recorded images were processed to estimate MST by selecting the whole area of the bird within the picture and comparing it with the values obtained using selected equations in literature, and to record the surface temperatures of the body parts. The MST estimated by infrared images were not statistically different (p > 0.05) from the values obtained by the equations. MST values significantly increased (p < 0.05) when the air temperature increased, but were not affected by bird age. However, age influenced the difference between MST and air temperature, which was highest on day 14. The technique of infrared thermal image analysis was useful to estimate the mean surface temperature of broiler chickens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Throughout history, women have often been perceived as hysterical and weak. This perception has been reflected through the representation of women in literature which has resulted in a limited scope of female normality and morality creating characteristics fundamentally different than male characters. Though these characteristics have been contributed as natural female characteristics, the theories of Jeremy Bentham, a 18th and 19th century Englishman, can be applied as a possible reason for these reactions. Bentham’s Panopticon, the theory of punishment wherein a constant unseen gaze peers at inmates theoretically creating paranoia and psychological breakdown, creates characteristics similar to those that women in literature seem to exhibit. In this paper, I will outline the characteristics of three various characters in novels. First, I will review the Panoptic literature that has been written on The Woman in Charlotte Perkins Gilman’s The Yellow Wallpaper, then I will conduct my own analysis on The Governess in Henry James’ The Turn of the Screw and Jane Eyre in Charlotte Bronte’s Jane Eyre . In this analysis, I will consider the “gaze,” the symbolic Panopticon implemented by society, and argue how characteristics present in stereotypical representations of women are not inherent in women due to gender or sex, but because women are most objectified and thereby most affected by the Panoptic gaze of society.