881 resultados para Active and reactive power control
Resumo:
This work proposes a new three-phase multipulse rectifier based on the delta autotransformer connection with DC-DC Boost stages and constant hysteresis control which has the objective of providing a reliable DC bus for on-board applications, electric motor drives and similars, always considering power quality issues. Thus, the proposal presents 0.99 power factor, 6% harmonic distortions in the currents from the mains and enhanced magnetic core utilization, which results in low weight and volume for the overall converter. The proposed control technique uses the simple constant hysteresis concept, thus leading to a low-cost but effective and reliable strategy. © 2011 IEEE.
Resumo:
Deterministic Optimal Reactive Power Dispatch problem has been extensively studied, such that the demand power and the availability of shunt reactive power compensators are known and fixed. Give this background, a two-stage stochastic optimization model is first formulated under the presumption that the load demand can be modeled as specified random parameters. A second stochastic chance-constrained model is presented considering uncertainty on the demand and the equivalent availability of shunt reactive power compensators. Simulations on six-bus and 30-bus test systems are used to illustrate the validity and essential features of the proposed models. This simulations shows that the proposed models can prevent to the power system operator about of the deficit of reactive power in the power system and suggest that shunt reactive sourses must be dispatched against the unavailability of any reactive source. © 2012 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Nesta tese e realizada a investigação experimental de uma estratégia de controle LPV (do inglês, linear parameter varying) aplicada ao amortecimento de oscilações eletromecânicas em sistemas elétricos de potencia. O estudo foi realizado em um modelo de sistema de potencia em escala reduzida de 10kVA, cuja configuração e do tipo maquina interligada a uma barra infinita, alem de testes em campo em uma unidade geradora de 350 MVA da Usina Hidrelétrica de Tucuruvi. Primeiramente, foi desenvolvido e testado computacionalmente um conjunto de rotinas para analise e síntese de controlador amortecedor do tipo LPV, bem como para identificação de modelos LPV da planta. Os coeficientes do controlador amortecedor LPV, no caso um Estabilizador de Sistemas de Potencia (ESP), dependem do valor de uma variável de operação selecionada que, neste estudo, foram as potencias ativa (P) e reativa (Q) nos terminais da unidade geradora. Para fins de projeto, a dinâmica da planta foi representada através de um modelo ARX LPV, o qual foi estimado a partir de dados coletados experimentalmente na planta, para uma ampla faixa de condições operacionais. A partir do modelo LPV da planta, os valores dos parâmetros do ESP LPV foram determinados via um problema de otimização convexa, na forma de uma LMI parametrizada (PLMI). A solução da PLMI e obtida a partir de uma relaxação via decomposição em soma de quadrados. O ESP LPV foi projetado de modo a garantir a estabilidade e o desempenho do sistema para uma ampla faixa de condições operacionais da planta, o que geralmente não e possível de obter com controladores convencionais a parâmetros fixos. A lei de controle amortecedor do ESP LPV foi implementada em um sistema embarcado baseado em um controlador digital de sinais. Os resultados experimentais mostraram um excelente desempenho do ESP LPV no amortecimento de oscilações eletromecânicas, tanto no sistema de potencia em escala reduzida, quanto em uma unidade geradora da UHE de Tucurui.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper, the optimal reactive power planning problem under risk is presented. The classical mixed-integer nonlinear model for reactive power planning is expanded into two stage stochastic model considering risk. This new model considers uncertainty on the demand load. The risk is quantified by a factor introduced into the objective function and is identified as the variance of the random variables. Finally numerical results illustrate the performance of the proposed model, that is applied to IEEE 30-bus test system to determine optimal amount and location for reactive power expansion.
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
This paper shows how the detailed examination of active and nonactive power components may produce new information for modern smart meters. For this purpose, a prototype of electronic power meter has been implemented and applied to the evaluation of the Conservative Power Theory (CPT). Considering five sorts of loads, under four different operating conditions, the experimental results indicate that the CPT is able to provide a good methodology for load characterization, which could possibly benefits consumers and power utilities in several different ways. The results also show that depending on the situation, the analysis of nonactive power terms may be more important than the observation of traditional power quality indices, such as total harmonic distortion, unbalance factors or the fundamental positive sequence power factor.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work it is discussed the performance of the reactive power demand in three-leg transformer core and three-phase transformer bank, under different conditions of AC/DC double excitation. In order to analyse the influence of double excitation in reactive power theoretically a mathematical model was developed considering the mutual coupling between phases and the magnetic nonlinearity. The validity of the proposed model is verified by means of the experimental and simulated results.
Resumo:
A new approach called the Modified Barrier Lagrangian Function (MBLF) to solve the Optimal Reactive Power Flow problem is presented. In this approach, the inequality constraints are treated by the Modified Barrier Function (MBF) method, which has a finite convergence property: i.e. the optimal solution in the MBF method can actually be in the bound of the feasible set. Hence, the inequality constraints can be precisely equal to zero. Another property of the MBF method is that the barrier parameter does not need to be driven to zero to attain the solution. Therefore, the conditioning of the involved Hessian matrix is greatly enhanced. In order to show this, a comparative analysis of the numeric conditioning of the Hessian matrix of the MBLF approach, by the decomposition in singular values, is carried out. The feasibility of the proposed approach is also demonstrated with comparative tests to Interior Point Method (IPM) using various IEEE test systems and two networks derived from Brazilian generation/transmission system. The results show that the MBLF method is computationally more attractive than the IPM in terms of speed, number of iterations and numerical conditioning. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND: Genetically modified MON 87701 X MON 89788 soybean (Glycine max), which expresses the Cry1Ac and EPSP-synthase proteins, has been registered for commercial use in Brazil. To develop an Insect Resistance Management (IRM) program for this event, laboratory and field studies were conducted to assess the high-dose concept and level of control it provides against Anticarsia gemmatalis and Pseudoplusia includens. RESULTS: The purified Cry1Ac protein was more active against A. gemmatalis [LC50 (FL 95%) = 0.23 (0.150.34) mu g Cry1Ac mL-1 diet] than P. includens [LC50 (FL 95%) = 3.72 (2.654.86) mu g Cry1Ac mL-1 diet]. In bioassays with freeze-dried MON 87701X MON 89788 soybean tissue diluted 25 times in an artificial diet, there was 100% mortality of A. gemmatalis and up to 95.79% mortality for P. includens. In leaf-disc bioassays and under conditions of high artificial infestation in the greenhouse and natural infestation in the field, MON 87701X MON 89788 soybean showed a high level of efficacy against both target pests. CONCLUSIONS: The MON 87701X MON 89788 soybean provides a high level of control against A. gemmatalis and P. includes, but a high-dose event only to A. gemmatalis. Copyright (c) 2012 Society of Chemical Industry