971 resultados para Abdominal Aortic-aneurysm


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to perform finite element (FE) analyses of patient-specific abdominal aortic aneurysms, geometries derived from medical images must be meshed with suitable elements. We propose a semi-automatic method for generating conforming hexahedral meshes directly from contours segmented from medical images. Magnetic resonance images are generated using a protocol developed to give the abdominal aorta high contrast against the surrounding soft tissue. These data allow us to distinguish between the different structures of interest. We build novel quadrilateral meshes for each surface of the sectioned geometry and generate conforming hexahedral meshes by combining the quadrilateral meshes. The three-layered morphology of both the arterial wall and thrombus is incorporated using parameters determined from experiments. We demonstrate the quality of our patient-specific meshes using the element Scaled Jacobian. The method efficiently generates high-quality elements suitable for FE analysis, even in the bifurcation region of the aorta into the iliac arteries. For example, hexahedral meshes of up to 125,000 elements are generated in less than 130 s, with 94.8 % of elements well suited for FE analysis. We provide novel input for simulations by independently meshing both the arterial wall and intraluminal thrombus of the aneurysm, and their respective layered morphologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A postal survey was conducted of all hospitals in Australia known to have a department of anaesthesia and an intensive care or high dependency unit. Each hospital was asked to report the anaesthetic and postoperative analgesic techniques used for the last ten cases of four common major surgical procedures-aorto-femoral bypass, repair of an abdominal aortic aneurysm, hemicolectomy and anterior resection of the rectum. Half of 76 hospitals sent a survey form completed and returned it. Responding hospitals were larger on average, than non-responding ones, but otherwise typical of them in terms of university affiliation and metropolitan versus rural location. For each of the procedures studied the proportion of cases in which epidural block was used intra- or postoperatively varied from 0% to 100%. Depending on the procedure, between 65% and 85% of hospitals used epidural block sometimes, with between 10% and 90% of patients in these hospitals being managed with this technique. There is wide variation in the use of epidural block, intra- and postoperatively, in Australia, variation that is unlikely to be explained by systematic differences between institutions in the patients seen or their suitability for one or other technique. This pattern of practice mirrors the lack of agreement about the proper place for epidural techniques evident in the recent literature. There is a widespread belief among clinicians that this is a question of great importance. Accordingly, we believe that anaesthetists and surgeons share an ethical responsibility to enter suitable patients in an appropriately designed randomized controlled trial in order to resolve this question.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background - Marfan syndrome (MS) is a genetic disorder caused by a mutation in the fibrillin gene FBN1. Bicuspid aortic valve (BAV) is a congenital heart malformation of unknown cause. Both conditions are associated with ascending aortic aneurysm and premature death. This study examined the relationship among the secretion of extracellular matrix proteins fibrillin, fibronectin, tenascin, and vascular smooth muscle cell (VSMC) apoptosis. The role of matrix metalloproteinase (MMP)- 2 in VSMC apoptosis was studied in MS aneurysm. Methods and Results - Aneurysm tissue was obtained from patients undergoing surgery ( MS: 4 M, 1 F, age 27 - 45 years; BAV: 3 M, 2 F, age 28 - 65 years). Normal aorta from subjects with nonaneurysm disease was also collected ( 4 M, 1 F, age 23 - 93 years). MS and BAV aneurysm histology showed areas of cystic medial necrosis (CMN) without inflammatory infiltrate. Immunohistochemical study of cultured MS and BAV VSMC showed intracellular accumulation and reduction of extracellular distribution of fibrillin, fibronectin, and tenascin. Western blot showed no increase in expression of fibrillin, fibronectin, or tenascin in MS or BAV VSMC and increased expression of MMP-2 in MS VSMCs. There was 4-fold increase in loss of cultured VSMC incubated in serum-free medium for 24 hours in both MS ( 27 +/- 8%) and BAV ( 32 +/- 14%) compared with control ( 7 +/- 5%). Conclusions - In MS and BAV there is alteration in both the amount and quality of secreted proteins and an increased degree of VSMC apoptosis. Up-regulation of MMP-2 might play a role in VSMC apoptosis in MS VSMC. The findings suggest the presence of a fundamental cellular abnormality in BAV thoracic aorta, possibly of genetic origin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine if mid-term outcome following endovascular aneurysm repair (EVAR) with the Endurant Stent Graft (Medtronic, Santa Rosa, CA, USA) is influenced by severe proximal neck angulation. METHODS: A retrospective case-control study was performed using data from a prospective multicenter database. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with neck length >15 mm, infrarenal angle (β) >75°, and/or suprarenal angle (α) >60°, or neck length >10 mm with β >60°, and/or α >45° were compared with a matched control group. Primary endpoint was primary clinical success. Secondary endpoints were freedom from rupture, type 1A endoleak, stent fractures, freedom from neck-related reinterventions, and aneurysm-related adverse events. Morphological neck variation over time was also assessed. RESULTS: Forty-five patients were included in the study group and were compared with a matched control group with 65 patients. Median follow-up time was 49.5 months (range 30.5-58.4). The 4-year primary clinical success estimates were 83% and 80% for the angulated and nonangulated groups (p = .42). Proximal neck angulation did not affect primary clinical success in a multivariate model (hazard ratio 1.56, 95% confidence interval 0.55-4.41). Groups did not differ significantly in regard to freedom from rupture (p = .79), freedom from type 1A endoleak (p = .79), freedom from neck-related adverse events (p = .68), and neck-related reinterventions (p = .68). Neck angle reduction was more pronounced in patients with severe proximal neck angulation (mean Δα -15.6°, mean Δβ -30.6°) than in the control group (mean Δα -0.39°, mean Δβ -5.9°) (p < .001). CONCLUSION: Mid-term outcomes following EVAR with the Endurant Stent Graft were not influenced by severe proximal neck angulation in our population. Despite the conformability of the device, moderate aortic neck remodeling was identified in the group of patients with angulated neck anatomy on the first computed tomography scan after implantation with no important further remodeling afterwards. No device integrity failures were encountered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10) and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10). All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background: Configuration of the abdominal aorta is related to healthy aging and a variety of disorders. Objectives: We aimed to assess heritable and environmental effects on the abdominal aortic diameter. Methods: 114 adult (69 monozygotic, 45 same-sex dizygotic) twin pairs (mean age 43.6 ± 16.3 years) underwent abdominal ultrasound with Esaote MyLab 70X ultrasound machine to visualize the abdominal aorta below the level of the origin of the renal arteries and 1-3 cm above the bifurcation. Results: Age- and sex-adjusted heritability of the abdominal aortic diameter below the level of the origin of the renal arteries was 40% [95% confidence interval (CI), 14 to 67%] and 55% above the aortic bifurcation (95% CI, 45 to 70%). None of the aortic diameters showed common environmental effects, but unshared environmental effects were responsible for 60% and 45% of the traits, respectively. Conclusions: Our analysis documents the moderate heritability and its segment-specific difference of the abdominal aortic diameter. The moderate part of variance was explained by unshared environmental components, emphasizing the importance of lifestyle factors in primary prevention. Further studies in this field may guide future gene-mapping efforts and investigate specific lifestyle factors to prevent abdominal aortic dilatation and its complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: : Intravascular ultrasound (IVUS) generates high definition circumferential cross-sectional images and provides real-time readout of vascular dimensions, including visualization of vessel branches. We have used it as an alternative to angiography in the endovascular thoracic aneurysm repair work-up. METHODS: : Out of consecutive 203 patients with descending thoracic aortic aneurysm, 89 (43.8%) received endovascular treatment [mean age, 68 ± 8 years; range, 29-82; male, 79 (88.7%); female, 10 (11.3%)] without using angiography during the endovascular procedure. IVUS (6 F, 12.5 MHz probe or 10 F 9 MHz) coupled with fluoroscopy for the placement of radiopaque markers was used for target site identification, landing zone measurement, device positioning, and assessment of endovascular repair. RESULTS: : Hospital mortality was 4/89 (4.5%). Number of devices implanted in each patient was 1.2 (range, 1-3). X-ray exposure time was 12 ± 8 minutes. Median procedure time was 63 ± 20 minutes. Conversion to open surgery was necessary in one patient (1.1%) because of aortic dissection. In nine patients (10.1%) left subclavian artery was covered because of a short neck. Two patients (2.2%) had vascular access lesions and required surgical repair. One patient developed paraplegia (1.1%). Early endoleak was observed in eight patients (8.9%) and 4 (4.5%) required additional procedures (proximal or distal extensions). Late conversion was necessary in one patient (1.1%). CONCLUSIONS: : IVUS provides all information necessary for device selection, target site identification as well as safe and correct deployment of thoracic endoprostheses and makes periprocedural angiography unnecessary, thus avoiding the risk of renal failure because of contrast medium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate influence of traditional cardiovascular risk factors (CVRF) and subclinical atherosclerosis (ATS) burden on early stages of abdominal aortic diameter (AAD) widening among adults. 2,052 consecutive patients (P) (39 % women), mean age 52 ± 13 years, were prospectively screened for CVRF, ATS, and AAD. B-mode ultrasound was used to evaluate the largest AAD and to detect carotid and femoral atherosclerotic plaques. Mean AAD was 15.2 ± 2.8 mm. Atherosclerotic plaques were detected in 71 % of patients. Significant univariate correlation between AAD, traditional CVRF, and ABS was found. However, multiple regression analysis showed that only seven of them were significantly and weakly correlated with AAD (R² = 0.27, p < 0.001). On the other hand, a multivariate logistic analysis was used to evaluate CVRF impact on enlarged AAD ≥25 mm (EAAD) as compared to those with AAD <25 mm. These factors did not account for more than 30 % of interaction (R² = 0.30, p = 0.001). Furthermore, despite a large proportion of patients with high number of CVRF, and subclinical ATS, rate of patients with AAD ≥25 mm was low (1 %) and scattered regardless their CHD risk score or ATS burden. In conclusion, these results suggest that although some traditional CVRF and presence of ATS are associated with early stages of EAAD, other determinants still need to be identified for a better understanding of abdominal aortic aneurysm pathogenesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: to assess the outcome of endovascular aortic aneurysm repair (EVAR) using intravascular ultrasound (IVUS) without angiography. MATERIALS/METHODS: eighty consecutive patients (median age 69 years (range 25-90): male 72 (90%), female 8 (10%)) underwent endovascular aneurysm repair (AAA 68 (85%), TAA 12 (15%)) using either angiography in 31/80 patients (39%) or IVUS in 49/80 patients (61%) in accordance to the surgeons preference. RESULTS: hospital mortality was 2/80 (3%), 1/68 for AAA (2%), 1/12 for TAA (8%), 2/31 for angiography (7%), and 0/49 for IVUS (0.0%: NS). Median quantity of contrast medium was 190 ml (range: 20-350) for angiography versus 0 ml for IVUS (p<0.01). Median X-ray exposure time 24 min (range 9-65 min) versus 8 min (range 0-60 min) for IVUS (p<0.05). No coverage of renal or suprarenal artery orifices occurred in either group. Conversion to open surgery was necessary in 4/80 patients (5%), 1/31 for angiography (3%) and 3/49 patients for IVUS (6%: NS). Early endoleaks were observed in 13/80 patients (16%): 8/31 patients for angiography (26%) versus 5/49 for IVUS (10%: p<0.05): 5/13 endoleaks resolved spontaneously (39%) whereas 8/13 (61%) required additional procedures. CONCLUSIONS: IVUS is a reliable tool for EVAR. In most cases, perprocedural angiography is not necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abdominal aortic aneurysm reconstruction is usually performed in vascular surgical practice. However, the repair of an abdominal aortic aneurysm associated with a pelvic kidney is rare. Our goal is to present a case report of an abdominal aortic aneurysm associated with two congenital pelvic kidneys wich was treated successfully by aneurysmectomy and inclusion of an aortoaortic graft.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We analyzed the effects of saline infusion for the maintenance of blood volume on pulmonary gas exchange in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. We studied 20 adult mongrel dogs weighing 12 to 23 kg divided into two groups: ischemia-reperfusion group (IRG, N = 10) and IRG submitted to saline infusion for the maintenance of mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, N = 10). All animals were anesthetized and maintained on spontaneous ventilation. After obtaining baseline measurements, occlusion of the supraceliac aorta was performed by the inflation of a Fogarty catheter. After 60 min of ischemia, the balloon was deflated and the animals were observed for another 60 min of reperfusion. The measurements were made at 10 and 45 min of ischemia, and 5, 30, and 60 min of reperfusion. Pulmonary gas exchange was impaired in the IRG-SS group as demonstrated by the increase of the alveolar-arterial oxygen difference (21 ± 14 in IRG-SS vs 11 ± 8 in IRG after 60 min of reperfusion, P = 0.004 in IRG-SS in relation to baseline values) and the decrease of oxygen partial pressure in arterial blood (58 ± 15 in IRG-SS vs 76 ± 15 in IRG after 60 min of reperfusion, P = 0.001 in IRG-SS in relation to baseline values), which was correlated with the highest degree of pulmonary edema in morphometric analysis (0.16 ± 0.06 in IRG-SS vs 0.09 ± 0.04 in IRG, P = 0.03 between groups). There was also a smaller ventilatory compensation of metabolic acidosis after the reperfusion. We conclude that infusion of normal saline worsened the gas exchange induced by pulmonary reperfusion injury in this experimental model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To report a technique to maintain pelvic flow to an internal iliac artery (IIA) with aneurysm in a patient with Marfan syndrome, and previously treated by infrarenal abdominal aortic aneurysm open procedure. Retrograde endovascular hypogastric artery preservation (REHAP) through flexible endograft implantation from external iliac artery (EIA) to internal iliac artery (IIA) was used. REHAP was a reasonable, minimally invasive and elegant alternative (new) to maintain pelvic arterial flow in Marfan syndrome. However, the long-term durability is unknown, and so, it should be used in selected patients.

Relevância:

100.00% 100.00%

Publicador: