876 resultados para ALDITOL ACETATE STANDARDS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research project aimed the following goal: promote the creation, use and disclosure of OER in a Group of Schools, involving schools and teachers from different learning levels, expecting to test and validate the use of OER, in a learning-teaching model towards curricular innovation. Defining as a starting point different subjects and teachers from distinct academic areas, we have implemented a set of activities leading to the creation of OER supported, when possible, in FLOSS tools. We adopted an action research methodology with a dual purpose: to act within a community of teachers and students, while increasing at the same time their knowledge, as well as the researcher's. The activity was developed cooperatively in order to process a certain reality of the teaching-learning process, through practical/reflective action towards it and inducing its implementation by others in the Portuguese School System, based on the production and sharing OER.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatographic separation of highly polar basic drugs with ideal ionspray mass spectrometry volatile mobile phases is a difficult challenge. A new quantification procedure was developed using hydrophilic interaction chromatography-mass spectrometry with turbo-ionspray ionization in the positive mode. After addition of deuterated internal standards and simple clean-up liquid extraction, the dried extracts were reconstituted in 500 microL pure acetonitrile and 5 microL was directly injected onto a Waters Atlantis HILIC 150- x 2.1-mm, 3-microm column. Chromatographic separations of cocaine, seven metabolites, and anhydroecgonine were obtained by linear gradient-elution with decreasing high concentrations of acetonitrile (80-56% in 18 min). This high proportion of organic solvent makes it easier to be coupled with MS. The eluent was buffered with 2 mM ammonium acetate at pH 4.5. Except for m-hydroxy-benzoylecgonine, the within-day and between-day precisions at 20, 100, and 500 ng/mL were below 7 and 19.1%, respectively. Accuracy was also below +/- 13.5% at all tested concentrations. The limit of quantification was 5 ng/mL (%Diff < 16.1, %RSD < 4.3) and the limit of detection below 0.5 ng/mL. This method was successfully applied to a fatal overdose. In Switzerland, cocaine abuse has dramatically increased in the last few years. A 45-year-old man, a known HIV-positive drug user, was found dead at home. According to relatives, cocaine was self-injected about 10 times during the evening before death. A low amount of cocaine (0.45 mg) was detected in the bloody fluid taken from a syringe discovered near the corpse. Besides injection marks, no significant lesions were detected during the forensic autopsy. Toxicological investigations showed high cocaine concentrations in all body fluids and tissues. The peripheral blood concentrations of cocaine, benzoylecgonine, and methylecgonine were 5.0, 10.4, and 4.1 mg/L, respectively. The brain concentrations of cocaine, benzoylecgonine, and methylecgonine were 21.2, 3.8, and 3.3 mg/kg, respectively. The highest concentrations of norcocaine (about 1 mg/L) were measured in bile and urine. Very high levels of cocaine were determined in hair (160 ng/mg), indicating chronic cocaine use. A low concentration of anhydroecgonine methylester was also found in urine (0.65 mg/L) suggesting recent cocaine inhalation. Therapeutic blood concentrations of fluoxetine (0.15 mg/L) and buprenorphine (0.1 microg/L) were also discovered. A relatively high concentration of Delta(9)-THC was measured both in peripheral blood (8.2 microg/L) and brain cortex (13.5 microg/kg), suggesting that the victim was under the influence of cannabis at the time of death. In addition, fluoxetine might have enhanced the toxic effects of cocaine because of its weak pro-arrhythmogenic properties. Likewise, combination of cannabinoids and cocaine might have increase detrimental cardiovascular effects. Altogether, these results indicate a lethal cocaine overdose with a minor contribution of fluoxetine and cannabinoids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the plurality of institutional environments in which standards for the service sector are expected to support the rise of a global knowledge-based economy. Despite the careful wording of the World Trade Organization (WTO), a whole range of international bodies still have the capacity to define technical specifications affecting how services are expected to be traded on worldwide basis. The analysis relies on global political economy approaches to extend to the area of service standards the assumption that the process of globalization is not opposing states and markets, but a joint expression of both of them including new patterns and agents of structural change through formal and informal power and regulatory practices. It analyses on a cross-institutional basis patterns of authority in the institutional setting of service standards in the context of the International Organisation for Standardisation (ISO), the European Union, and the United States. In contrast to conventional views opposing the American system to the ISO/European framework, the paper questions the robustness of this opposition by showing that institutional developments of service standards are likely to face trade-offs and compromises across those systems and between two opposing models of standardisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gastrointestinal stromal tumours (GIST), despite being rare, pose a relevant medical problem from the viewpoint of diagnosis and management. GIST are fragile, liable to metastasize and often located in delicate structures. Surgical options, therefore, are limited. In the last decade an improved understanding of the molecular mechanisms of the disease has resulted in novel modes of treatment. The introduction of systemic tyrosine kinase inhibitor therapy with imatinib has significantly improved the outcome of the disease and prolonged the survival of GIST patients. For many patients the acute threat of a deadly cancer has been transformed into a manageable chronic condition. Drug safety, tolerability and compliance, subjects of concern in all long-term therapies, have proven to be acceptable for the tyrosine kinase inhibitor imatinib. The present paper provides a compact overview of the epidemiology, pathophysiology and morphology of GIST, with special reference to the underlying molecular biology. Relevant aspects of diagnosis, therapy and monitoring of the disease are reviewed with particular emphasis on the available clinical evidence and recent guidelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Acetate metabolism in skeletal muscle is regulated by acetylCoA synthetase (ACS). The main function of ACS is to provide cells with acetylCoA, a key molecule for numerous metabolic pathways including fatty acid and cholesterol synthesis and the Krebs cycle. METHODS: Hyperpolarized [1-(13)C]acetate prepared via dissolution dynamic nuclear polarization was injected intravenously at different concentrations into rats. The (13)C magnetic resonance signals of [1-(13)C]acetate and [1-(13)C]acetylcarnitine were recorded in vivo for 1min. The kinetic rate constants related to the transformation of acetate into acetylcarnitine were deduced from the 3s time resolution measurements using two approaches, either mathematical modeling or relative metabolite ratios. RESULTS: Although separated by two biochemical transformations, a kinetic analysis of the (13)C label flow from [1-(13)C]acetate to [1-(13)C]acetylcarnitine led to a unique determination of the activity of ACS. The in vivo Michaelis constants for ACS were KM=0.35±0.13mM and Vmax=0.199±0.031μmol/g/min. CONCLUSIONS: The conversion rates from hyperpolarized acetate into acetylcarnitine were quantified in vivo and, although separated by two enzymatic reactions, these rates uniquely defined the activity of ACS. The conversion rates associated with ACS were obtained using two analytical approaches, both methods yielding similar results. GENERAL SIGNIFICANCE: This study demonstrates the feasibility of directly measuring ACS activity in vivo and, since the activity of ACS can be affected by various pathological states such as cancer or diabetes, the proposed method could be used to non-invasively probe metabolic signatures of ACS in diseased tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess the effectiveness of glatiramer acetate (GA) compared to other multiple sclerosis (MS) therapies in routine clinical practice. MATERIALS AND METHODS Observational cohort study carried out in MS patients treated with GA (GA cohort) or other MS therapies -switched from GA- (non-GA cohort). Study data were obtained through review of our MS patient database. The primary endpoint was the Expanded Disability Status Scale (EDSS) scores reached at the end of treatment/last check-up. RESULTS A total of 180 patients were included: GA cohort n = 120, non-GA cohort n = 60. Patients in the GA cohort showed better EDSS scores at the end of treatment/last check-up (mean ± SD, 2.8 ± 1.8 vs. 3.9 ± 2.2; P = 0.001) and were 1.65 times more likely to show better EDSS scores compared to the non-GA cohort (odds ratio, 0.606; 95%CI, 0.436-0.843; P = 0.003). Patients in the GA cohort showed longer mean time to reach EDSS scores of 6 (209.1 [95%CI, 187.6-230.6] vs. 164.3 [95% CI, 137.0-191.6] months; P = 0.004) and slower disability progression (hazard ratio, 0.415 [95%CI, 0.286-0.603]; P < 0.001). The annualized relapse rate was lower in the GA cohort (mean ± SD, 0.5 ± 0.5 vs. 0.8 ± 0.5; P = 0.001) and patients' quality of life was improved in this study cohort compared to the non-GA cohort (mean ± SD, 0.7 ± 0.1 vs. 0.6 ± 0.2; P = 0.01). CONCLUSIONS GA may slow down the progression of EDSS scores to a greater extent than other MS therapies, as well as achieving a greater reduction in relapses and a greater improvement in patients' quality of life. Switching from GA to other MS therapies has not proved to entail a better response to treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The COSMIN checklist is a tool for evaluating the methodological quality of studies on measurement properties of health-related patient-reported outcomes. The aim of this study is to determine the inter-rater agreement and reliability of each item score of the COSMIN checklist (n = 114). Methods: 75 articles evaluating measurement properties were randomly selected from the bibliographic database compiled by the Patient-Reported Outcome Measurement Group, Oxford, UK. Raters were asked to assess the methodological quality of three articles, using the COSMIN checklist. In a one-way design, percentage agreement and intraclass kappa coefficients or quadratic-weighted kappa coefficients were calculated for each item. Results: 88 raters participated. Of the 75 selected articles, 26 articles were rated by four to six participants, and 49 by two or three participants. Overall, percentage agreement was appropriate (68% was above 80% agreement), and the kappa coefficients for the COSMIN items were low (61% was below 0.40, 6% was above 0.75). Reasons for low inter-rater agreement were need for subjective judgement, and accustom to different standards, terminology and definitions.Conclusions: Results indicated that raters often choose the same response option, but that it is difficult on item level to distinguish between articles. When using the COSMIN checklist in a systematic review, we recommend getting some training and experience, completing it by two independent raters, and reaching consensus on one final rating. Instructions for using the checklist are improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability), the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs), i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist.Method: An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1) a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2) an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written) Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will subsequently be field-tested by assessing the inter-rater reproducibility of the checklist.Discussion: Since the study will mainly be anonymous, problems that are commonly encountered in face-to-face group meetings, such as the dominance of certain persons in the communication process, will be avoided. By performing a Delphi study and involving many experts, the likelihood that the checklist will have sufficient credibility to be accepted and implemented will increase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several superstructure design methodologies have been developed for low volume road bridges by the Iowa State University Bridge Engineering Center. However, to date no standard abutment designs have been developed. Thus, there was a need to establish an easy to use design methodology in addition to generating generic abutment standards and other design aids for the more common substructure systems used in Iowa. The final report for this project consists of three volumes. The first volume (this volume) summarizes the research completed in this project. A survey of the Iowa County Engineers was conducted from which it was determined that while most counties use similar types of abutments, only 17 percent use some type of standard abutment designs or plans. A literature review revealed several possible alternative abutment systems for future use on low volume road bridges in addition to two separate substructure lateral load analysis methods. These consisted of a linear and a non-linear method. The linear analysis method was used for this project due to its relative simplicity and the relative accuracy of the maximum pile moment when compared to values obtained from the more complex non-linear analysis method. The resulting design methodology was developed for single span stub abutments supported on steel or timber piles with a bridge span length ranging from 20 to 90 ft and roadway widths of 24 and 30 ft. However, other roadway widths can be designed using the foundation design template provided. The backwall height is limited to a range of 6 to 12 ft, and the soil type is classified as cohesive or cohesionless. The design methodology was developed using the guidelines specified by the American Association of State Highway Transportation Officials Standard Specifications, the Iowa Department of Transportation Bridge Design Manual, and the National Design Specifications for Wood Construction. The second volume introduces and outlines the use of the various design aids developed for this project. Charts for determining dead and live gravity loads based on the roadway width, span length, and superstructure type are provided. A foundation design template was developed in which the engineer can check a substructure design by inputting basic bridge site information. Tables published by the Iowa Department of Transportation that provide values for estimating pile friction and end bearing for different combinations of soils and pile types are also included. Generic standard abutment plans were developed for which the engineer can provide necessary bridge site information in the spaces provided. These tools enable engineers to design and detail county bridge substructures more efficiently. The third volume provides two sets of calculations that demonstrate the application of the substructure design methodology developed in this project. These calculations also verify the accuracy of the foundation design template. The printouts from the foundation design template are provided at the end of each example. Also several tables provide various foundation details for a pre-cast double tee superstructure with different combinations of soil type, backwall height, and pile type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several superstructure design methodologies have been developed for low volume road bridges by the Iowa State University Bridge Engineering Center. However, to date no standard abutment designs have been developed. Thus, there was a need to establish an easy to use design methodology in addition to generating generic abutment standards and other design aids for the more common substructure systems used in Iowa. The final report for this project consists of three volumes. The first volume summarizes the research completed in this project. A survey of the Iowa County Engineers was conducted from which it was determined that while most counties use similar types of abutments, only 17 percent use some type of standard abutment designs or plans. A literature review revealed several possible alternative abutment systems for future use on low volume road bridges in addition to two separate substructure lateral load analysis methods. These consisted of a linear and a non-linear method. The linear analysis method was used for this project due to its relative simplicity and the relative accuracy of the maximum pile moment when compared to values obtained from the more complex non-linear analysis method. The resulting design methodology was developed for single span stub abutments supported on steel or timber piles with a bridge span length ranging from 20 to 90 ft and roadway widths of 24 and 30 ft. However, other roadway widths can be designed using the foundation design template provided. The backwall height is limited to a range of 6 to 12 ft, and the soil type is classified as cohesive or cohesionless. The design methodology was developed using the guidelines specified by the American Association of State Highway Transportation Officials Standard Specifications, the Iowa Department of Transportation Bridge Design Manual, and the National Design Specifications for Wood Construction. The second volume introduces and outlines the use of the various design aids developed for this project. Charts for determining dead and live gravity loads based on the roadway width, span length, and superstructure type are provided. A foundation design template was developed in which the engineer can check a substructure design by inputting basic bridge site information. Tables published by the Iowa Department of Transportation that provide values for estimating pile friction and end bearing for different combinations of soils and pile types are also included. Generic standard abutment plans were developed for which the engineer can provide necessary bridge site information in the spaces provided. These tools enable engineers to design and detail county bridge substructures more efficiently. The third volume (this volume) provides two sets of calculations that demonstrate the application of the substructure design methodology developed in this project. These calculations also verify the accuracy of the foundation design template. The printouts from the foundation design template are provided at the end of each example. Also several tables provide various foundation details for a pre-cast double tee superstructure with different combinations of soil type, backwall height, and pile type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several superstructure design methodologies have been developed for low volume road bridges by the Iowa State University Bridge Engineering Center. However, to date no standard abutment designs have been developed. Thus, there was a need to establish an easy to use design methodology in addition to generating generic abutment standards and other design aids for the more common substructure systems used in Iowa. The final report for this project consists of three volumes. The first volume summarizes the research completed in this project. A survey of the Iowa County Engineers was conducted from which it was determined that while most counties use similar types of abutments, only 17 percent use some type of standard abutment designs or plans. A literature review revealed several possible alternative abutment systems for future use on low volume road bridges in addition to two separate substructure lateral load analysis methods. These consisted of a linear and a non-linear method. The linear analysis method was used for this project due to its relative simplicity and the relative accuracy of the maximum pile moment when compared to values obtained from the more complex non-linear analysis method. The resulting design methodology was developed for single span stub abutments supported on steel or timber piles with a bridge span length ranging from 20 to 90 ft and roadway widths of 24 and 30 ft. However, other roadway widths can be designed using the foundation design template provided. The backwall height is limited to a range of 6 to 12 ft, and the soil type is classified as cohesive or cohesionless. The design methodology was developed using the guidelines specified by the American Association of State Highway Transportation Officials Standard Specifications, the Iowa Department of Transportation Bridge Design Manual, and the National Design Specifications for Wood Construction. The second volume (this volume) introduces and outlines the use of the various design aids developed for this project. Charts for determining dead and live gravity loads based on the roadway width, span length, and superstructure type are provided. A foundation design template was developed in which the engineer can check a substructure design by inputting basic bridge site information. Tables published by the Iowa Department of Transportation that provide values for estimating pile friction and end bearing for different combinations of soils and pile types are also included. Generic standard abutment plans were developed for which the engineer can provide necessary bridge site information in the spaces provided. These tools enable engineers to design and detail county bridge substructures more efficiently. The third volume provides two sets of calculations that demonstrate the application of the substructure design methodology developed in this project. These calculations also verify the accuracy of the foundation design template. The printouts from the foundation design template are provided at the end of each example. Also several tables provide various foundation details for a pre-cast double tee superstructure with different combinations of soil type, backwall height, and pile type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Head and neck squamous cell carcinomas are frequently diagnosed at an advanced stage. Their treatment remains controversial, and has to be multidisciplinary. External beam radiotherapy is a recognized treatment option after radical curative surgery in order to improve local control. Different adjuvant treatment options have been studied in order to improve the outcome of these patients. We review in this paper the different prognostic factors indicating an adjuvant treatment and the interest of treatment intensification in bad prognostic patients.