292 resultados para ADC


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to determine the nutritional value of different protein sources for "dourado" (Salminus brasiliensis). Thirty juveniles per group (33.51±1.4 g) were hand fed on a reference diet (70%) added of tested ingredients (30%) and chromium oxide III (0.1%). Apparent digestibility coefficients of the gross energy (ADC GE), crude protein (ADC CP) and amino acids of the tested ingredients were evaluated. Corn gluten meal yielded the best results for ADC GE and ADC CP (95.7 and 96.9%, respectively) amongst plant ingredients. Spray-dried blood meal yielded the best values of ADC GE and ADC CP amongst animal ingredients (94.1 and 96.3%, respectively). Wheat bran yielded poorest ADCs coefficients (77 for ADC GE and 88.2% for ADC CP).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine the frequency of recent skin injuries in children with neuromotor disabilities and its association with disability. DESIGN: Cross-sectional study of 168 children with neuromotor disabilities aged 2-16 years. SETTING: Two outpatient child rehabilitation centres. MAIN OUTCOME MEASURES: Children were classified as unrestricted walkers, restricted walkers or wheelchair dependent. Each participant's body surface was systematically examined for recent skin injuries with the exception of the anal-genital area. RESULTS: The mean age of our sample was 7.8 (SD 3.7) years with a 3:2 male/female ratio. Overall, 64% had cerebral palsy, 17% a neuromuscular disease and 19% other motor disabilities. Participants had on average 5.3 (SD 4.5) recent skin injuries (max 19), of which 2.5 were bruises (SD 3.3, max 16), 2.4 were abrasions, scratches or cuts (SD 3.0, max 16) and 0.4 were pressure lesions (SD 0.8, max 4). There was a significant decrease in the frequency of recent skin injuries and of bruises with increasing severity of motor disability. Most of this variation was accounted for by injuries to the lower limbs. There were no significant effects of gender, learning disabilities or other comorbidities. CONCLUSIONS: Children with neuromotor disabilities present a progressive reduction in the number of skin injuries with decreasing mobility. Therefore, recent skin injuries in this population which are unusual by their number, appearance or distribution, should raise at least the same level of suspicion for physical abuse as in children without disabilities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three commonly used pain scales, the visual analogue scale, the Wong-Baker Faces Pain Scale, and the Faces Pain Scale Revised were administered to 122 Thai children, of whom half were HIV infected, in order to assess their validity. These scales presented moderate to good correlation and moderate agreement, sufficient for valid use in Thai children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

WE USED A MURINE MODEL OF TRANSIENT FOCAL CEREBRAL ISCHEMIA TO STUDY: 1) in vivo DTI long-term temporal evolution of the apparent diffusion coefficient (ADC) and diffusion fractional anisotropy (FA) at days 4, 10, 15 and 21 after stroke 2) ex vivo distribution of a plasticity-related protein (GAP-43) and its relationship with the ex vivo DTI characteristics of the striato-thalamic pathway (21 days). All animals recovered motor function. In vivo ADC within the infarct was significantly increased after stroke. In the stroke group, GAP-43 expression and FA values were significantly higher in the ipsilateral (IL) striatum and contralateral (CL) hippocampus compared to the shams. DTI tractography showed fiber trajectories connecting the CL striatum to the stroke region, where increased GAP43 and FA were observed and fiber tracts from the CL striatum terminating in the IL hippocampus.Our data demonstrate that DTI changes parallel histological remodeling and recovery of function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Urinary lithogenic and inhibitory factors were studied in 27 preterm infants; 16 had total parenteral nutrition (TPN) and 11 had breastmilk with an additional glucose-sodium chloride infusion. Urines were collected for 24 hours on day 2 (period A), day 3 (B), and once between days 4 and 10 (C). Urinary calcium oxalate saturation was calculated by the computer program EQUIL 2. Renal ultrasonography was performed every second week until discharge. The calcium/creatinine ratio increased in infants on TPN (A 0.91; C 1.68 mol/mol) and was significantly higher at period C than that in infants on breastmilk/infusion (A 0.52; C 0.36). The oxalate/creatinine ratio was persistently higher with TPN (203 mmol/mol) than with breastmilk/infusion (98; 137). The citrate/creatinine remained constant with TPN (0.44 mol/mol), whereas it increased significantly with breastmilk/infusion (0.26; 0.49). Calcium/citrate rose considerably with TPN, but decreased with breastmilk/infusion to a significantly lower level than with TPN. The urinary calcium oxalate saturation increased with TPN (2.4; 4.5) and decreased with breastmilk/infusion (2.1; 1.5) to a significantly lower value than with TPN. Nephrocalcinosis developed in two infants on TPN. Mean daily calcium intake was similar in both groups, whereas protein, sodium, and phosphorus intake were significantly higher on TPN. It is concluded that the increase in urinary calcium oxalate saturation observed with TPN is due to the combined effect of an increased urinary calcium excretion and higher urinary oxalate/creatinine and calcium/citrate ratios. The changes observed are likely to be caused by TPN itself, which differs in several respects from breastmilk feeding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare qualitative and quantitative magnetic resonance (MR) imaging characteristics of hepatic hemangiomas in patients with normal, fibrotic and cirrhotic livers. MATERIALS AND METHODS: Retrospective, institutional review board approved study (waiver of informed consent). Eighty-nine consecutive patients with 231 hepatic hemangiomas who underwent liver MR imaging for lesion characterization were included. Lesions were classified into three groups according to the patients' liver condition: no underlying liver disease (group 1), fibrosis (group 2) and cirrhosis (group 3). Qualitative and quantitative characteristics (number, size, signal intensities on T1-, T2-, and DW MR images, T2 shine-through effect, enhancement patterns (classical, rapidly filling, delayed filling), and ADC values) were compared. RESULTS: There were 160 (69%), 45 (20%), and 26 (11%) hemangiomas in groups 1, 2 and 3, respectively. Lesions were larger in patients with normal liver (group 1 vs. groups 2 and 3; P=.009). No difference was found between the groups on T2-weighted images (fat-suppressed fast spin-echo (P=.82) and single-shot (P=.25)) and in enhancement patterns (P=.56). Mean ADC values of hemangiomas were similar between groups 1, 2 and 3 (2.11±.52×10(-3)mm(2)/s, 2.1±.53×10(-3)mm(2)/s and 2.14±.44×10(-3)mm(2)/s, P=87, respectively). T2 shine-through effect was less frequently observed in cirrhosis (P=.02). CONCLUSION: MR imaging characteristics of hepatic hemangioma were similar in patients with normal compared to fibrotic and cirrhotic livers. Smaller lesion size was observed with liver disease and less T2 shine-through effect was seen in hemangiomas developed on cirrhosis, the latter being an important finding to highlight in these patients at risk of developing hepatocellular carcinoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The close relationship between the chlorophyll-meters readings and the total chlorophyll and nitrogen contents in leaves, has allowed their evaluation both in annual and perennial species. Besides, some physiological events such as the CO2 assimilation have also been estimated by chlorophyll meters. This work was carried out aiming to evaluate the gas exchanges of peach palms as a function of the chlorophyll SPAD-Meter readings. Three year-old peach palms from Yurimaguas, Peru were studied in Ubatuba, SP, Brazil, spaced 2 x 1 m in area under a natural gradient of organic matter which allowed four plots to be considered, according to the peach palms leaves colors, from light yellow to dark green. The SPAD readings and the stomatal frequency of leaflets were evaluated. The photosynthetic photon flux density (PPFD, μmol m-2 s-1), the leaf temperature (Tleaf, ºC), the CO2 assimilation (A, μmol m-2 s-1), the stomatal conductance (g s, mol m-2 s-1), the transpiration (E, mmol m-2 s-1) and the intercellular CO2 concentration (Ci, μmol mol-1) were evaluated with a portable infrared gas analyzer (LCA-4, ADC BioScientific Ltd., Great Amwell, U.K.). A linear increase in the CO2 assimilation as a function of the SPAD readings (y = -0.34 + 0.19x, R² = 0.99), indicates that they can be a rapid and cheap complementary method to evaluate in peach palms some important physiological events, such as CO2 assimilation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MR imaging is currently regarded as a pivotal technique for the assessment of a variety of musculoskeletal conditions. Diffusion-weighted MR imaging (DWI) is a relatively recent sequence that provides information on the degree of cellularity of lesions. Apparent diffusion coefficient (ADC) value provides information on the movement of water molecules outside the cells. The literature contains many studies that have evaluated the role of DWI in musculoskeletal diseases. However, to date they yielded conflicting results on the use and the diagnostic capabilities of DWI in the area of musculoskeletal diseases. However, many of them have showed that DWI is a useful technique for the evaluation of the extent of the disease in a subset of musculoskeletal cancers. In terms of tissue characterization, DWI may be an adjunct to the more conventional MR imaging techniques but should be interpreted along with the signal of the lesion as observed on conventional sequences, especially in musculoskeletal cancers. Regarding the monitoring of response to therapy in cancer or inflammatory disease, the use of ADC value may represent a more reliable additional tool but must be compared to the initial ADC value of the lesions along with the knowledge of the actual therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Estudar a utilidade da sequência pesada em difusão na diferenciação das lesões mamárias benignas e malignas. MATERIAIS E MÉTODOS: Quarenta e cinco mulheres (idade média de 46,1 anos) com 52 nódulos de mama foram submetidas a ressonância magnética acrescida da sequência difusão. O coeficiente de difusão aparente (ADC) foi calculado através do mapa de ADC obtido pelo uso de cinco valores de b (0, 250, 500, 750 e 1.000 s/mm²). O valor de ADC médio de cada lesão foi correlacionado com achados de imagem e resultados histopatológicos. Valores de ADC de corte, sensibilidade e especificidade da sequência difusão na diferenciação das lesões benignas e malignas foram calculados. P < 0,05 foi considerado estatisticamente significativo. RESULTADOS: O valor de ADC médio foi significativamente menor para as lesões malignas (0,92 ± 0,26 × 10-3 mm²/s) comparado com as lesões benignas (1,50 ± 0,34 × 10-3 mm²/s) (p < 0,0001). A sequência difusão mostrou altas sensibilidade e especificidade (ambas 92,3%) na diferenciação entre lesões benignas e malignas. CONCLUSÃO: A sequência pesada em difusão representa um recurso potencial como coadjuvante da ressonância magnética das mamas na diferenciação das lesões benignas e malignas. Tal sequência pode ser facilmente inserida no protocolo padrão da ressonância magnética das mamas, sem aumento significativo no tempo de exame.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

DWI é uma técnica totalmente não invasiva que tem sido utilizada com sucesso por muitos anos em imagens do cérebro e recentemente incluída como parte da avaliação de outros sistemas, por exemplo, no abdome e pelve e na cabeça e pescoço. Apesar de a DWI e a medida dos valores de ADC serem capazes de fornecer informações de tipos histológicos específicos de tumores, a maioria dos centros de imagem ainda não os adotaram como parte da rotina na avaliação da cabeça e pescoço. A medida de ADC demonstrou ser útil para discriminar tipos específicos de tumores histológicos, especialmente para diferenciar lesões benignas sólidas de massas malignas, importante na avaliação de linfonodos cervicais, principalmente para diferenciar processos nodais benignos de malignos, para diferenciar as alterações pós-radioterapia de tumor residual e ter uso potencial para predizer sucesso terapêutico. Além disso, DWI/ADC parece ser um método mais seguro e mais acessível, considerando a ausência de radiação ionizante e ao maior custo do FDG-PET na localização de tumores e diferenciar massas benignas de malignas. Com todas essas vantagens e potencialidades, DWI/ADC certamente fará parte da rotina na avaliação por imagem da cabeça e pescoço.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors report a case where a quantitative assessment of the apparent diffusion coefficient (ADC) of liver metastasis in a patient undergoing chemotherapy has shown to be an effective early marker for predicting therapeutic response, anticipating changes in tumor size. A lesion with lower initial ADC value and early increase in such value in the course of the treatment tends to present a better therapeutic response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis concentrates on studying the operational disturbance behavior of machine tools integrated into FMS. Operational disturbances are short term failures of machine tools which are especially disruptive to unattended or unmanned operation of FMS. The main objective was to examine the effect of operational disturbances on reliability and operation time distribution for machine tools. The theoretical part of the thesis covers the fimdamentals of FMS relating to the subject of this study. The concept of FMS, its benefits and operator's role in FMS operation are reviewed. The importance of reliability is presented. The terms describing the operation time of machine tools are formed by adopting standards and references. The concept of failure and indicators describing reliability and operational performance for machine tools in FMSs are presented. The empirical part of the thesis describes the research methodology which is a combination of automated (ADC) and manual data collection. By using this methodology it is possible to have a complete view of the operation time distribution for studied machine tools. Data collection was carried out in four FMSs consisting of a total of 17 machine tools. Each FMS's basic features and the signals of ADC are described. The indicators describing the reliability and operation time distribution of machine tools were calculated according to collected data. The results showed that operational disturbances have a significant influence on machine tool reliability and operational performance. On average, an operational disturbance occurs every 8,6 hours of operation time and has a down time of 0,53 hours. Operational disturbances cause a 9,4% loss in operation time which is twice the amount of losses caused by technical failures (4,3%). Operational disturbances have a decreasing influence on the utilization rate. A poor operational disturbance behavior decreases the utilization rate. It was found that the features of a part family to be machined and the method technology related to it are defining the operational disturbance behavior of the machine tool. Main causes for operational disturbances were related to material quality variations, tool maintenance, NC program errors, ATC and machine tool control. Operator's role was emphasized. It was found that failure recording activity of the operators correlates with the utilization rate. The more precisely the operators record the failure, the higher is the utilization rate. Also the FMS organizations which record failures more precisely have fewer operational disturbances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIU: determinar la qualitat de vida de les persones amb demència ateses en una unitat avaluadora de deteriorament cognitiu. MÈTODE: estudi descriptiu transversal amb una mostra consecutiva no probabilística, formada per 42 persones amb demència tipus Alzheimer lleu o moderada i els seus cuidadors. La Qualitat de Vida (QV) es va avaluar amb el qüestionari QoL-AD (Quality of Life Alzheimer’s Disease) en les versions per al pacient (QoL-ADp) i per al cuidador (QoL-ADc). RESULTATS: la mitjana de puntuació del QoL-ADp va ser de 35,38 punts (DE = 5,24) i del QoL-Adc, de 30,60 (DE 5,33). La diferència entre aquests resultats és significativa (p<0,001). Els pacients amb simptomatologia depressiva i els seus cuidadors van puntuar significativament més baix el QoL-AD (p<0,001). En les freqüències per ítems del QoL-ADp s’observa que: més del 75% van valorar com a bona/excel·lent les condicions de vida, família, matrimoni/relació estreta, vida social, situació financera i vida en general; el 61% valoraren bona/excel·lent la capacitat per realitzar tasques a casa; prop del 50% pensava que l’estat d’ànim, l’energia, la salut física, la capacitat per fer coses per diversió i la visió de si mateixos era dolenta/regular, i el 85,7% opinava que la seva memòria era dolenta/regular. CONCLUSIONS: els resultats obtinguts en el QoL-AD no difereixen dels obtinguts en altres investigacions. Suggereixen que les intervencions que genera l’avaluació de la QV en la pràctica clínica inclouen aspectes centrats pròpiament en la malaltia i aspectes vinculats amb les relacions socials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho apresenta o desenvolvimento e calibração de tensiômetro de leitura automática, sendo o tensiômetro de mercúrio utilizado como padrão de comparação. Os ensaios foram conduzidos no Laboratório de Mecânica e Eletrônica do Departamento de Engenharia Agrícola da UFC. Esse equipamento difere do tensiômetro tradicional por substituir o manômetro de mercúrio por sensor de pressão. Tal dispositivo gera uma saída com valor de até no máximo 4,5 volts. O tensiômetro eletrônico é conectado a uma placa de aquisição de dados (DAQ) contendo um microprocessador, conversor analógico/digital (ADC) e saída serial, sendo tal placa ligada a um microcomputador. A bancada de ensaio constituiu-se de três caixas plásticas preenchidas com solo de textura franco- arenosa. Os dados foram coletados durante um mês e as equações geradas foram do tipo Count = offset + apsim, em que psim representa o potencial matricial fornecido pelo tensiômetro de mercúrio (kPa) e count a saída digial do ADC, com valores adimensionais de 0 a 4.095. Foram obtidos os valores máximo e mínimo de offset de 348,572 e 261,026, e de coeficiente angular de 36,675 kPa-1 e 34,421 kPa-1. Os resultados da regressão linear simples indicaram a existência de regressão a menos de 0,1% de significância e valores de coeficientes de correlação nunca inferiores a 0,9994.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main goal of the present Master’s Thesis project was to create a field-programmable gate array (FPGA) based system for the control of single-electron transistors or other cryoelectronic devices. The FPGA and similar technologies are studied in the present work. The fixed and programmable logic are compared with each other. The main features and limitations of the hardware used in the project are investigated. The hardware and software connections of the device to the computer are shown in detail. The software development techniques for FPGA-based design are described. The steps of design for programmable logic are considered. Furthermore, the results of filters implemented in the software are illustrated.