976 resultados para ABSOLUTE DEVIATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let I be an ideal in a local Cohen-Macaulay ring (A, m). Assume I to be generically a complete intersection of positive height. We compute the depth of the Rees algebra and the form ring of I when the analytic deviation of I equals one and its reduction number is also at most one. The formu- las we obtain coincide with the already known formulas for almost complete intersection ideals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using head-mounted eye tracker material, we assessed spatial recognition abilities (e.g., reaction to object permutation, removal or replacement with a new object) in participants with intellectual disabilities. The "Intellectual Disabilities (ID)" group (n=40) obtained a score totalling a 93.7% success rate, whereas the "Normal Control" group (n=40) scored 55.6% and took longer to fix their attention on the displaced object. The participants with an intellectual disability thus had a more accurate perception of spatial changes than controls. Interestingly, the ID participants were more reactive to object displacement than to removal of the object. In the specific test of novelty detection, however, the scores were similar, the two groups approaching 100% detection. Analysis of the strategies expressed by the ID group revealed that they engaged in more systematic object checking and were more sensitive than the control group to changes in the structure of the environment. Indeed, during the familiarisation phase, the "ID" group explored the collection of objects more slowly, and fixed their gaze for a longer time upon a significantly lower number of fixation points during visual sweeping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT. A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Skew deviation is a vertical ocular misalignment of prenuclear origin. Although well described in the literature, it is still probably underdiagnosed. Natural history of skew deviation is not well described in the literature. PURPOSE: To describe the clinical presentations, etiologies and follow-up of skew deviation. METHODS: Retrospective study of 29 patients diagnosed with skew deviation between 1993 and 1996. RESULTS: The commonest cause was cerebrovascular accident (12/29) and the commonest localisation was mesencephalic (9/29). Other causes included surgery (7/29), tumor (4/29), trauma (3/29), degeneration (3/29), inflammatory (2/29), increased intracranial pressure (1/29). Other localisations included cerebellum (5/29), ponto-mesencephalic (3/29), and medulla (2/29). Vertical diplopia was always accompanied by other neuro-ophthalmologic abnormalities. 69.2% (18/26) patients were totally asymptomatic after 7.5 months. 30.8% (8/26) were still symptomatic (diplopia). One patient required surgery, three patients were relieved with prisms, one patient needed monocular occlusion. One patient died during follow-up and precise data were lacking in two symptomatic patients. CONCLUSION: Skew deviation is not so rare, 10% of the cases referred to us for diplopia in 3 years. The diagnosis of skew deviation should be entertained when vertical diplopia cannot be explained by pathology of extraocular muscles, peripheral or central cranial nerve III or IV palsies, myasthenia, or orbital pathology. Prognosis for recovery in patients with skew deviation is good. 70% will recover, after a median time of 7.5 months. Surgery should be postponed at least for 12 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Workgroup diversity can be conceptualized as variety, separation, or disparity. Thus, the proper operationalization of diversity depends on how a diversity dimension has been defined. Analytically, the minimal diversity must be obtained when there are no differences on an attribute among the members of a group, however maximal diversity has a different shape for each conceptualization of diversity. Previous work on diversity indexes indicated maximum values for variety (e.g., Blau"s index and Teachman"s index), separation (e.g., standard deviation and mean Euclidean distance), and disparity (e.g., coefficient of variation and the Gini coefficient of concentration), although these maximum values are not valid for all group characteristics (i.e., group size and group size parity) and attribute scales (i.e., number of categories). We demonstrate analytically appropriate upper boundaries for conditional diversity determined by some specific group characteristics, avoiding the bias related to absolute diversity. This will allow applied researchers to make better interpretations regarding the relationship between group diversity and group outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new paint testing device was built to determine the resistance of paints to darkening due to road grime being tracked onto them. The device consists of a tire rotating on a sample drum. Soil was applied to the tire and then tracked onto paint samples which were attached to the drum. A colorimeter was used to measure the lightness of the paints after being tracked. Lightness is measured from 0 (absolute black) to 100 (absolute white). Four experiments were run to determine the optimum time length to track a sample, the reproducibility, the effects of different soils, and the maximum acceptable level for darkening of a paint. The following conclusions were reached: 1) the optimum tracking time was 10 minutes; 2) the reproducibility had a standard deviation of 1.5 lightness units; 3) different soils did not have a large effect on the amount of darkening on the paints; 4) a maximum acceptable darkness could not be established based on the limited amount of data; and 5) a correlation exists between the paints which were darkening in the field and the paints which were turning the darkest on the tracking wheel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The overeruption of upper molars due to the premature loss of antagonist teeth can be treated with the help of miniscrews. The aim of this study was to evaluate the movement of a typodont molar according to the biomechanical approach used with miniscrews. Study design: The study was conducted with four plaster models filled with typodont wax. In each model we used one absolute anchorage on the palatal side and another on the buccal side in different positions, thus generating four different biomechanical systems. A force of 150 g was applied to each side of the resin tooth. Periapical radiographs were taken preintrusion and immediately after completion of the intrusion. Photographs were taken in both the sagittal and occlusal planes every 3 min. The radiographic films and photographs were measured and compared. Results: A vertical movement of the molar was observed in all the models, with system 4 showing the greatest movement. Rotation in the occlusal plane only occurred in system 2, while in system 1 there was a change in the axial axis of 37 degrees. Conclusions: The anchorage site and the combination of forces applied may determine the resulting tooth movement

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena oli arvioida UPM-Kymmene Oyj, Kaukaan sellutehtaan havukuitulinjan uuden valkaisusäätömenetelmän, kompensoidun kappakerroinsäädön, ja vaaleusanalysaattoreiden käyttöönoton vaikutukset klooridioksidikulutukseen ja sellun laatuun. Kirjallisuusosassa esitelläänvalkaisun tärkeimpiä on-line ja in-line mittalaitteita sekä niitä hyödyntäviä säätöratkaisuja. Tiettävästi paras saatavilla oleva säätömenetelmä, kompensoitu kappakerroinsäätö määrittää klooridioksidiannoksen vaiheeseen tulevan massan kappaluvun tai vaaleuden perusteella. Valkaisukemikaaliannos optimoidaan jatkuvatoimisten vaaleus- ja jäännösmittausten sekä vaiheen jälkeisen saavutetun kappaluvuntai vaaleuden takaisinkytkennällä. Kokeellisessa osassa arvioitiin havulinjan valkaisusäätömenetelmän käyttöönoton vaikutukset klooridioksidikulutuksiin ja sellun laatuun vertailemalla uuden ja vanhan säätömenetelmän aikaisia kemikaalikulutuksia sekä välikappaluvun ja loppuvaaleuden itseisarvopoikkeamia tavoitteistaan. Lisäksi selvitettiin annossäätöön ja kompensoituun vaaleussäätöön perustuvan vanhan sekä kompensoitua kappakerroinsäätöä soveltavan uuden säätömenetelmän toimintaperiaatteet. Työssä kartoitettiin myös valkaisulinjan tarpeet uusille mittalaitteille sekä analysaattorin mittausten vertailukelpoisuus laboratorioanalyysien kanssa. Edelleen työssä arvioitiin tehtaan X koivuvalkaisulinjan uuden säätömenetelmän toimivuus. Kompensoidun kappakerroinsäädön käyttöönoton myötä valkaisun klooridioksidikulutukset pienenivät sekä välikappaluku ja loppuvaaleus saatiin pidettyä lähempänä tavoitteittaan. Säätömenetelmän toimivuuttaedisti vaaleusanalysaattoreiden mittausten korreloivuus laboratorioanalyysien kanssa. Vastaavat vaikutukset kemikaalikulutuksiin ja sellun laatuun havaittiin myös tehtaan X valkaisusäädön käyttöönotosta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Belt-drive systems have been and still are the most commonly used power transmission form in various applications of different scale and use. The peculiar features of the dynamics of the belt-drives include highly nonlinear deformation,large rigid body motion, a dynamical contact through a dry friction interface between the belt and pulleys with sticking and slipping zones, cyclic tension of the belt during the operation and creeping of the belt against the pulleys. The life of the belt-drive is critically related on these features, and therefore, amodel which can be used to study the correlations between the initial values and the responses of the belt-drives is a valuable source of information for the development process of the belt-drives. Traditionally, the finite element models of the belt-drives consist of a large number of elements thatmay lead to computational inefficiency. In this research, the beneficial features of the absolute nodal coordinate formulation are utilized in the modeling of the belt-drives in order to fulfill the following requirements for the successful and efficient analysis of the belt-drive systems: the exact modeling of the rigid body inertia during an arbitrary rigid body motion, the consideration of theeffect of the shear deformation, the exact description of the highly nonlinear deformations and a simple and realistic description of the contact. The use of distributed contact forces and high order beam and plate elements based on the absolute nodal coordinate formulation are applied to the modeling of the belt-drives in two- and three-dimensional cases. According to the numerical results, a realistic behavior of the belt-drives can be obtained with a significantly smaller number of elements and degrees of freedom in comparison to the previously published finite element models of belt-drives. The results of theexamples demonstrate the functionality and suitability of the absolute nodal coordinate formulation for the computationally efficient and realistic modeling ofbelt-drives. This study also introduces an approach to avoid the problems related to the use of the continuum mechanics approach in the definition of elastic forces on the absolute nodal coordinate formulation. This approach is applied to a new computationally efficient two-dimensional shear deformable beam element based on the absolute nodal coordinate formulation. The proposed beam element uses a linear displacement field neglecting higher-order terms and a reduced number of nodal coordinates, which leads to fewer degrees of freedom in a finite element.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimuksen kohteena olleen UPM-Kymmene Oyj Kajaanin tehtaan PK3:n laatusäätöjärjestelmä ja mittapalkki uusittiin, jolloin haluttiin selvittää uusinnan vaikutuksia laatusäätöjen suorituskykyyn ja paperin laatuun. Työn kirjallisessa osassa perehdyttiin paperinvalmistusprosessin osiin kyseisen sanomalehtipaperikoneen tapauksessa sekä keskeisimpiin paperin laatuominaisuuksiin liittyviin mittaus- ja säätölaitteisiin sekä niiden toimintaan. Seurattaviksi paperin laatusuureiksi valittiin neliömassa, kuivamassa, kosteus ja paksuus, jotka ovat sanomalehtipaperin tärkeimpiä online-mitattavia ominaisuuksia. Paperin laatusuureiden seurantaan käytetään erilaisia tunnuslukuja ja työkaluja, joita on esitelty tässä työssä. Laatusuureiden konesuuntaisen ja poikkisuuntaisen seurannan tunnusluvuksi valittiin yleisesti käytössä oleva 2σ-keskiarvohajonta. Säätöjen suorituskykyä seurattiin suorituskykykolmion ohjausmatkaindeksien (CTI) ja erosuureen integraalien (IAE) avulla. Kokeellisessa osassa kerättiin mittaustietoja sekä vanhan että uuden laatusäätöjärjestelmän aikana. Seurattavat ajotilanteet paperikoneella jaettiin stabiiliin ajoon ja muutostilanteisiin, jotka käsittävät katkot ja lajinvaihtotilanteet. Stabiilin ajon aikana selvitettiin laatusuureiden hajontojen ja säätöjen suorituskykyindeksien normaaleissa tasoissa tapahtuneet muutokset. Muutostilanteiden osalta haluttiin selvittää, nopeuttaako järjestelmäuusinta katkoista toipumista ja lajinvaihtoaikaa. Stabiilin ajon seurannasta saatujen tulosten perusteella neliömassan ja kuivamassan konesuuntaiset hajonnat kasvoivat järjestelmäuusinnan myötä, mutta kosteuden konesuuntaiset hajonnat pienenivät. Laatusuureiden poikkisuuntaisista hajonnoista neliömassan sekä kuivamassan hajonnat kasvoivat ja kosteuden sekä paksuuden hajonnat pienenivät joidenkin lajien osalta. Poikkisuuntaisten laatusuureiden, etenkin paksuuden, toipuminen katkon jälkeen nopeutui. Myös lajinvaihtoon kuluva aika lyheni poikkisuuntaisilla laatusuureilla. Muutostilanteiden konesuuntaisten hajontojen asettumisajat eivät juuri parantuneet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers) used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI) estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI) procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.