967 resultados para 60 minute mean
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The reproducibility of the 6-min walking test (6MWT) needs to be more solidly studied. This study aimed to investigate the reproducibility of two 6MWTs performed on subsequent days in a large and representative sample of patients with chronic obstructive pulmonary disease (COPD), and to quantify the learning effect between the two tests, as well as its determinants.In a retrospective observational study, 1,514 patients with COPD performed two 6MWTs on subsequent days. Other measurements included body composition (dual X-ray absorptiometry), dyspnoea (Medical Research Council scale) and comorbidity (Charlson index).Although the 6MWT was reproducible (intraclass correlation coefficient=0.93), patients walked farther in the second test (391 m, 95% CI 155-585 m versus 418 m, 95% CI 185-605 m; p < 0.0001). on average, the second 6MWT increased by 27 m (or 7%), and 82% of patients improved in the second test. Determinants of improvement >= 42 m in the second test (upper limit of the clinically important change) were as follows: first 6MWT < 350 m, Charlson index < 2 and body mass index < 30 kg.m(-2) (OR 2.49, 0.76 and 0.60, respectively).The 6MWT was statistically reproducible in a representative sample of patients with COPD. However, the vast majority of patients improved significantly in the second test by an average learning effect of 27 m.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To evaluate the effect of different resting periods, after induced muscle fatigue, in the quadriceps femoris neuromuscular performance, in healthy subjects. Methods: Sixty-four volunteers, of both genders, with an average of 21,8 ± 1,7 years and mean body mass index of 24,2 ± 3,7 Kg/m2 were randomly assigned into 4 groups: control group (was not induced fatigue); Experimental Group 1 (Exp. 1 1 minute of rest after fatigue); Experimental Group 3 (Exp. 3 3 minutes of rest after fatigue) and Experimental Group 5 (Exp. 5 5 minutes of rest after fatigue). The subjects were evaluated to the knee´s joint position sense (JPS), followed by 5 flexion-extension knee concentric isokinetic contractions at 60°/s, with concomitant recording of median frequency (Fmed) of rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM). Then they underwent a muscle fatigue protocol (30 flexion-extension knee concentric contractions at 60°/s) and were reevaluated on the isokinetic performance, Fmed and JPS. Blood lactate levels were measured before initial assessment, immediately after the fatigue protocol and 5 minutes after the end of the rest period. Results: The adoption of 3 minutes of rest was sufficient to restore the initial conditions for the peak torque normalized by body weight and the VL and VM Fmed. The joint position sense returned to its initial values with 1 minute rest. The lactate concentration remained high regardless of the adopted rest period. Conclusion: The use of 3-minute rest period is sufficient for the reestablishment of the neuromuscular parameters to the pre fatigue values.
Resumo:
Objective-To compare the ability of a sidestream capnograph and a mainstream capnograph to measure end-tidal CO2 (ETCO2) and provide accurate estimates of Paco(2) in mechanically ventilated dogs.Design-Randomized, double Latin square.Animals-6 healthy adult dogs.Procedure-Anesthesia was induced and neuromuscular blockade achieved by IV administration of pancuronium bromide. Mechanical ventilation was used to induce conditions of standard ventilation, hyperventilation, and hypoventilation. While tidal volume was held constant, changes in minute volume ventilation and Paco(2) were made by changing the respiratory rate. Arterial blood gas analysis was performed and ETCO2 measurements were obtained by use of either a mainstream or a sidestream capnographic analyzer.Results-A linear regression model and bias analysis were used to compare Paco(2) and ETCO2 measurements; ETCO2 measurements obtained by both capnographs correlated well with Paco(2). Compared with Paco(2), mainstream ETCO2 values differed by 3.15 +/- 4.89 mm Hg (mean bias +/- SD), whereas the bias observed with the sidestream ETCO2 system was significantly higher (5.65 +/- 5.57 mm Hg). Regardless of the device used to measure ETCO2, bias increased as Paco(2) exceeded 60 mm Hg.Conclusions and Clinical Relevance-Although the mainstream capnograph was slightly more accurate, both methods of ETCO2 measurement correlated well with Paco(2) and reflected changes in the ventilatory status. However, ETCO2 values > 45 mm Hg may inaccurately reflect the severity of hypoventilation as Paco(2) may be underestimated during conditions of hypercapnia (Paco(2) > 60 mm Hg).
Resumo:
Objective To compare the cardiorespiratory changes induced by equipotent concentrations of halothane (HAL), isoflurane (ISO) and sevollurane (SEVO) before and after hemorrhage.Study design. Prospective, randomized clinical trial.Animals. Twenty-four healthy adult dogs weighing 15.4 +/- 3.4 kg (mean +/- SD).Methods. Animals were randomly allocated to one of three groups (n = 8 per group). In each group, anesthesia was maintained with 1.5 minimum alveolar concentration of HAL (1.3%), ISO (1.9%,) and SEVO (3.5%) in oxygen. Controlled ventilation was performed to maintain eucapnia. Cardiorespiratory variables were evaluated at baseline (between 60 and 90 minutes after induction), immediately after and 30 minutes after the withdrawal of 32 mL kg(-1) of blood (400% of the estimated blood volume) over a 30-minute period.Results. During baseline conditions, ISO and SEVO resulted in higher cardiac index (CI) than HAL. Heart rates were higher with SEVO at baseline. while mean arterial pressure (MAP) and mean pulmonary arterial pressure did not differ between groups. Although heart rate values were higher for ISO and SEVO after hemorrhage, only ISO resulted in a higher CI when compared with HAL. In ISO-anesthetized dogs, MAP was higher immediately after hemorrhage, and this was related to better maintenance of CI and to an increase in systemic vascular resistance index from baseline.Conclusions. Although the hemodynamic responses of ISO and SEVO are similar in normovolaemic dogs, ISO results in better maintenance of circulatory function during the early period following a massive blood loss. Clinical relevance Inhaled anesthetics should be used judiciously in animals presented with blood loss. However, if an inhalational agent is to be used under these circumstances, ISO may provide better hemodynamic stability than SEVO or HAL.
Resumo:
O objetivo foi a padronização de modelo experimental de coração isolado parabiótico em coelhos, testando sua estabilidade e durabilidade, para fins de pesquisa cardiovascular. Foram utilizados 66 coelhos raça Norfolk-2000 divididos em grupo doador do coração isolado e animais suporte, totalizando 33 preparações. Mediante auxilio de bombas peristálticas estabeleceu-se suporte circulatório para o coração isolado mantendo-se fluxo constante(16ml/min.). Um balão intraventricular foi inserido no ventrículo esquerdo, sendo ajustado para gerar pressão diastólica de ± 10mmHg. A freqüência foi fixada em 120 batimentos por minuto mediante o uso de marcapasso. Foram avaliadas variáveis hemodinâmicas, laboratoriais e anatomopatológicas. Das 33 preparações, 13 foram excluídas mediante critérios pré-estabelecidos. Das 20 restantes, 10 cumpriram o tempo máximo do protocolo(180 minutos). Com relação ao animal suporte houve deterioração hemodinâmica progressiva c/ queda da pressão arterial média(89,30±6,09mmHg->47,50±6,35mmHg). Com relação ao corações isolado, das 10 preparações que cumpriram os 180 minutos de protocolo, houve estabilidade hemodinâmica. As variáveis laboratoriais mostraram queda progressiva do sódio, potássio e hemoglobina, sendo compatível com hemodiluição. O exame anatomopatológico mostrou espaçamento maior entre fibras, compatível com edema. O presente modelo mostrou estabilidade e atividade de 100% das preparações em 60 minutos, havendo perdas progressivas chegando a 50% das preparações em atividade em 180 minutos. O presente modelo, dentro das limitações estabelecidas é viável para pesquisas cardiovasculares.
Resumo:
We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.
Resumo:
ObjectiveTo investigate the cardiorespiratory, nociceptive and endocrine effects of the combination of propofol and remifentanil, in dogs sedated with acepromazine.Study designProspective randomized, blinded, cross-over experimental trial.AnimalsTwelve healthy adult female cross-breed dogs, mean weight 18.4 +/- 2.3 kg.MethodsDogs were sedated with intravenous (IV) acepromazine (0.05 mg kg-1) followed by induction of anesthesia with IV propofol (5 mg kg-1). Anesthesia was maintained with IV propofol (0.2 mg kg-1 minute-1) and remifentanil, infused as follows: R1, 0.125 mu g kg-1 minute-1; R2, 0.25 mu g kg-1 minute-1; and R3, 0.5 mu g kg-1 minute-1. The same dogs were administered each dose of remifentanil at 1-week intervals. Heart rate (HR), mean arterial pressure (MAP), respiratory rate (f(R)), end tidal CO(2) (Pe'CO(2)), arterial hemoglobin O(2) saturation, blood gases, and rectal temperature were measured before induction, and 5, 15, 30, 45, 60, 75, 90, and 120 minutes after beginning the infusion. Nociceptive response was investigated by electrical stimulus (50 V, 5 Hz and 10 ms). Blood samples were collected for plasma cortisol measurements. Statistical analysis was performed by anova (p < 0.05).ResultsIn all treatments, HR decreased during anesthesia with increasing doses of remifentanil, and increased significantly immediately after the end of infusion. MAP remained stable during anesthesia (72-98 mmHg). Antinociception was proportional to the remifentanil infusion dose, and was considered satisfactory only with R2 and R3. Plasma cortisol concentration decreased during anesthesia in all treatments. Recovery was smooth and fast in all dogs.Conclusions and clinical relevanceInfusion of 0.25-0.5 mu g kg-1 minute-1 remifentanil combined with 0.2 mg kg-1 minute-1 propofol produced little effect on arterial blood pressure and led to a good recovery. The analgesia produced was sufficient to control the nociceptive response applied by electrical stimulation, suggesting that it may be appropriate for performing surgery.
Resumo:
Daily ultrasound examinations were conducted from Days 10 to 60 (ovulation = Day 0) of pregnancy to monitor the conceptus in jennies (n = 12). The embryonic vesicle was first detected on Day 11.5 +/- 0.9 (mean +/- SD; range 10 to 13d) and was mobile until movement ceased (fixation) on Day 15.5 +/- 1.4 (range, 13 to 18d). The vesicle was spherical from Days 10 to 18 (mean growth rate, 3.2 mm/d), non spherical (irregular) with a reduced growth rate (0.5 mm/d) from Days 19 to 29, and then grew at a moderate rate (1.6 mm/d) up to Day 46. on average, detection of the embryo proper (consistently located on the ventral aspect of the yolk sac) and embryonic heartbeat were Days 20.7 +/- 1.2 and 23.5 +/- 1.3, respectively. Formation of the allantoic sac was first detected on Day 24.4 +/- 1.7 and was complete on Day 36.8 +/- 1.6. Descent of the fetus (and formation of the umbilical cord) began on Day 37.9 +/- 1.7 and was complete on Day 44.1 +/- 2.1. Crown-ramp length averaged 3.7, 15.4, 22.7, 37.5 and 59.6 mm on Days 20, 30, 40, 50 and 60, respectively. In general, morphologic features and dates of occurrence were similar to those reported previously in the mare. (C) 1998 by Elsevier B.V.
Resumo:
Male Holtzman rats weighting 200-250 g were anesthetized with zoletil 50 mg/Kg (tiletamine chloridrate 125.0 mg and zolazepan chloridrate 125.0 mg) into quadriceps muscle and stainless steel cannulas were implanted into their supraoptic nucleus (SON). We investigated the effects of the injection into the supraoptic nucleus (SON) of FK 409, a nitric oxide donor, and N(W-)nitro-L-arginine methyl ester (L-NAME), a nitric oxide synthase inhibitor (NOS), on the salivary secretion, arterial blood pressure, sodium excretion and urinary volume induced by pilocarpine, which was injected into SON. The drugs were injected in 0.5 mul volume over 30-60 s. Controls was injected with a similar volume of 0.15 M NaCl. FK 409 and L-NAME were injected at doses of 20 mug/0.5 mul and 40 mug/0.5 mul. respectively. The amount of saliva secretion was studied over a five-minute period after injection of pilocarpine into SON. Injection of pilocarpine (10, 20, 40, 80, 160 mug/mul) into SON produced a dose-dependent increase in salivary secretion. L-NAME was injected into SON prior to the injection of pilocarpine into SON, producing an increase in salivary secretion due to the effect of pilocarpine. FK 409 injected into SON attenuating the increase in salivary secretion induced by pilocarpine. Mean arterial pressure (MAP) increase after injections of pilocarpine into the SON. L-NAME injected into the SON prior to injection of pilocarpine into SON increased the MAP. FK 409 injected into the SON prior to pilocarpine attenuated the effect of pilocarpine on MAP. Pilocarpine (0.5 mumol/0.5 mul) injected into the SON induced an increase in sodium and urinary excretion. L-NAME injected prior to pilocarpine into the SON increased the urinary sodium excretion and urinary volume induced by pilocarpine. FK 409 injected prior to pilocarpine into the SON decreased the sodium excretion and urinary volume induced by pilocarpine. All these roles of pilocarpine depend on the release of nitric oxide into the SON. In summary the present results show: a) SON is involved in pilocarpine-induced salivation; b) that mechanism involves increase in MAP, sodium excretion and urinary volume. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
In the present study we compared the effects produced by moxonidine (alpha(2)-adrenoceptor/imidazoline agonist) injected into the 4th cerebral ventricle and into the lateral cerebral ventricle on mean arterial pressure, heart rate and on renal, mesenteric and hindquarter vascular resistances, as well as the possible action of moxonidine on central alpha(1)- or alpha(2)-adrenoceptors to produce cardiovascular responses. Male Holtzman rats (n = 7-8) anesthetized with urethane (0.5 g/kg, intravenously - i.v.) and alpha-chloralose (60 mg/kg, i.v.) were used. Moxonidine (5, 10 and 20 nmol) injected into the 4th ventricle reduced arterial pressure (-19 +/- 5, -30 +/- 7 and -43 +/- 8 mmHg vs. vehicle: 2 +/- 4 mmHg), heart rate (-10 +/- 6, - 16 +/- 7 and -27 +/- 9 beats per minute - bpm, vs. vehicle: 4 +/- 5 bpm), and renal, mesenteric and hindquarter vascular resistances. Moxonidine (5, 10 and 20 nmol) into the lateral ventricle only reduced renal vascular resistance (-77 +/- 17%, - 85 +/- 13%, -89 +/- 10% vs. vehicle: 3 +/- 4%), without changes on arterial pressure, heart rate and mesenteric and hindquarter vascular resistances. Pre-treatment with the selective alpha(2)-adrenoceptor antagonist yohimbine (80, 160 and 320 nmol) injected into the 4th ventricle attenuated the hypotension (-32 +/- 5, -25 +/- 4 and -12 +/- 6 mmHg), bradycardia (-26 +/- 11, -23 +/- 5 and -11 +/- 6 bpm) and the reduction in renal, mesenteric and hindquarter vascular resistances produced by moxonidine (20 nmol) into the 4th ventricle. Pretreatment with yohimbine (320 nmol) into the lateral ventricle did not change the renal vasodilation produced by moxonidine (20 nmol) into the lateral ventricle. The alpha(1)-adrenoceptor antagonist prazosin (320 nmol) injected into the 4th ventricle did not affect the cardiovascular effects of moxonidine. However, prazosin (80, 160 and 320 nmol) into the lateral ventricle abolished the renal vasodilation (-17 +/- 4, -6 +/- 9 and 2 +/- 11%) produced by moxonidine. The results indicate that the decrease in renal vascular resistance due to moxonidine action in the forebrain is mediated by alpha(1)-adrenoceptors, while the cardiovascular effects produced by moxonidine acting in the brainstern depend at least partially on the activation of coadrenoceptors. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Statement of the problem. In selecting a disinfectant for dental prostheses, compatibility between the disinfectant and the type of denture base material must be considered to avoid adverse effects on the hardness of the acrylic resin.Purpose. This study investigated the hardness of 2 denture base resins after disinfection and long-term water immersion.Material and methods. Thirty-two disk-shaped specimens (13 mm in diameter and 8 mm thick) were fabricated from each resin (Lucitone 550 and QC-20), polished, stored in water at 37degreesC for 48 hours, and submitted to hardness tests (Vickers hardness number [VHN]) before disinfection. Disinfection methods included scrubbing with 4% chlorhexidine gluconate for 1 minute, immersion for 10 minutes in I of the tested disinfectant Solutions (n=8) (3.78% sodium perborate, 4% chlorhexidine gluconate, or 1% sodium hypochorite), and immersion in water for 3 minutes. The disinfection procedures were repeated 4 times, and 12 hardness measurements were made on each specimen. Control specimens (not disinfected) were stored in water for 56 minutes. Hardness tests (VHN) were also performed after 15, 30, 60, 90, and 120 days of storage in water. Statistical analyses of data were conducted with a repeated measures 3-way analysis of variance (ANOVA) and Tukey post-hoc test (alpha=.05).Results. Mean values +/- SD for Lucitone 550 (16.52 +/- 0.94 VHN) and QC-20 (9.61 +/- 0.62 VHN) demonstrated a significant (P<.05) decrease in hardness after disinfection, regardless of material and disinfectant solutions used (Lucitone 550: 15.25 +/- 0.74; QC-20: 8.09 +/- 0.39). However, this effect was reversed after 15 days of storage in water. Both materials exhibited a continuous increase (P<.05) in hardness values for up to 60 days of water storage, after which no significant change was observed.Conclusion. Within the limitations of this in vitro study, QC-20 and Lucitone 550 specimens exhibited significantly lower hardness values after disinfection regardless of the disinfectant solution used.
Resumo:
A model describing dissociation of monoprotonic acid and a method for the determination of its pK value are presented. The model is based on a mean field approximation. The Poisson-Boltzmann equation, adopting spherical symmetry, is numerically solved, and the solution of its linearized form is written. By use of the pH values of a dilution experiment of galacturonic acid as the entry data, the proposed method allowed estimation of the value of pK = 3.25 at a temperature of 25 degrees C. Values for the complex dimensions and dissociation degree are calculated using experimental pH values for solution concentration values ranging from 0.1 to 60 mM. The present analysis leads to the conclusion that the Poisson-Boltzmann equation or its linear form is equally suited for the description of such systems.