891 resultados para 3d Ultrasound
Resumo:
To evaluate several protocols for the application of ultrasound during removal of cast posts with varying core configurations cemented with zinc phosphate. Sixty maxillary canines were distributed into three groups (n = 20): group 1 - core with 5 mm diameter/height and post diameter of 1.3 mm; groups 2 and 3 - core with the same diameter as the post (1.3 mm) and heights of 5 mm and 3 mm, respectively. Posts/cores were cemented using a standard technique with zinc phosphate cement. Each group was divided into two subgroups according to the ultrasonic vibration mode: point vibration - ultrasonic vibration applied to the core surface for 5 s, on each face totalling 25 s; alternate vibration - intermittent application of ultrasonic vibration for 10 s to the labial and lingual surfaces, 10 s to the mesial and distal surfaces and 5 s to the incisal surface, totalling 25 s. The specimens were submitted to the tensile test using an Instron machine (1 mm min(-1)) and results were analysed by anova and t-test. The failure type was also analysed. Statistical analysis showed significant differences between groups relating to the core preparations (P < 0.05). The lowest mean values of traction force were obtained for group 3 (46.1 +/- 7.7 N), followed by group 2 (89.0 +/- 2.7 N) and group 1 (160.4 +/- 7.5 N). Regarding ultrasonic vibration, the lowest mean was observed with alternate vibration (81.1 +/- 10.1 N), which was significantly lower than the point vibration (115.9 +/- 9.5 N) (P < 0.05). Cohesive failure occurred in all cases. A reduction in core diameter/height and intermittent ultrasonic application improved the removal of cast posts cemented with zinc phosphate.
Resumo:
P>Aim To evaluate by 3D profilometry and scanning electron microscopy (SEM), the marginal adaptation of mineral trioxide aggregate (MTA) and Sealer 26 placed in root-end cavities with direct vision or under an optical microscope. Methodology The root ends of 52 root filled canine teeth were filled with MTA or Sealer 26 under direct vision or optical microscope (n = 13). In each group, eight specimens were analysed by profilometry for measurement of the area and depth of gaps. In the other five specimens, gap area was measured using SEM to verify marginal adaptation and surface characteristic. Data were analysed by parametric (anova and Tukey) and non-parametric (Kruskal-Wallis and Dunn) tests. Results The assessment of the adaptation of both materials to dentine was not influenced by the mode of visualization, which was confirmed by both profilometry and SEM observations. The voids measured with profilometry for Sealer 26 under direct vision were significantly wider and deeper than those for MTA under direct vision (P < 0.05). In SEM, significantly larger gap areas were observed with Sealer 26 (P < 0.05). Conclusion Root-end cavities filled with MTA had smaller gaps and better marginal adaptation than Sealer 26.
Resumo:
Geographical information systems (GIS) coupled to 3D visualisation technology is an emerging tool for urban planning and landscape design applications. The utility of 3D GIS for realistically visualising the built environment and proposed development scenarios is much advocated in the literature. Planners assess the merits of proposed changes using visual impact assessment (VIA). We have used Arcview GIS and visualisation software: called PolyTRIM from the University of Toronto, Centre for Landscape Research (CLR) to create a 3D scene for the entrance to a University campus. The paper investigates the thesis that to facilitate VIA in planning and design requires not only visualisation, but also a structured evaluation technique (Delphi) to arbitrate the decision-making process. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Growing evidence supports low-intensity pulsed ultrasound (US) as an osteogenic mechanical stimulus. Its effects on isolated bone cells and on fractured bone are established. However, its effects on osteoporosis are not clear. This study examined US effects on ovariectomy (OVX) induced bone changes within the rodent hindlimb (distal femur and proximal tibia), and on normal bone in animals following sham-OVX. Animals were exposed to daily unilateral active-US and contralateral inactive-US for 12 weeks. Bone status was assessed using dual energy X-ray absorptiometry and histomorphometry. Ovariectomy resulted in significant bone changes. Low-intensity pulsed US did not influence these changes. These results suggest that the US dose introduced may not be a beneficial treatment for osteoporosis, and that intact bone may be less sensitive to US than fractured bone and isolated bone cells. This may relate to the biophysical mechanisms of action of US, US-bone interactions and tissue level processes taking place.
Resumo:
Perineal ultrasound was used to detect and quantify levator activity by measuring the displacement of the internal urethral meatus against the inferoposterior margin of the symphysis pubis, Women who had previously been instructed in pelvic floor muscle exercises were more likely to contract the levator muscle when asked to do so than were those without previous instruction (P
Resumo:
A prospective clinical study was carried out to evaluate the influence of posture on perineal ultrasound imaging parameters. One hundred and thirty-two consecutive women presenting with symptoms of lower urinary tract dysfunction were examined by multichannel videourodynamics and perineal ultrasound, both supine and standing. Ultrasound included color Doppler imaging when available, i.e. in a subgroup of 99 patients. The position of the bladder neck at rest was higher in the supine position (P
Resumo:
In a prospective study 105 patients with symptoms of stress incontinence underwent video-urodynamic testing, including resting urethral pressure profilometry and translabial ultrasound. The urethral pressure profile (UPP) included maximum urethral closure pressure (MUCP), functional length (FL) and area under the curve (AUC). Ultrasound parameters included urethral thickness, urethral rotation and bladder neck descent, as well as funneling/opening of the internal urethral meatus on Valsalva maneuver. Levator contraction strength was assessed measuring the cranioventral displacement of the internal meatus. Negative correlations between UPP data and age, parity and previous surgery were observed which were consistent with literature data. There was a positive correlation :between the urethral AP diameter on ultrasound and the MUCP, which agrees with reports showing reduced sphincter thickness or volume in stress-incontinent women. Hypermobility on ultrasound did not correlate with UPP data. However, a lower MUCP correlated with extensive opening of the bladder neck. Finally, there was a trend towards poorer pelvic floor function with lower MUCP measurements.
Resumo:
If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.
Resumo:
We have established a realtime fetal tele-ultrasound consultation service in Queensland, which has been integrated into our routine clinical practice, The service, which uses ISDN transmission at 384 kbit/s, allows patients in Townsville to be examined by subspecialists in Brisbane, 1500 km away. For the 90 tele-ultrasound consultations performed for the first 71 patients, 90% of the babies have been delivered, and outcome data have been received on all the pregnancies. All significant anomalies and diagnoses have been confirmed. The referring clinicians would have physically referred 24 of the 71 patients to Brisbane in the absence of telemedicine. A crude cost-benefit calculation suggests that the tele-ultrasound service resulted in a net saving of A$6340, and at the same time enabled almost four times the number of consultations to be carried out.
Resumo:
Abnormal left ventricular (LV) filling is common, but not universal, in hypertensive LV hypertrophy (LVH). We sought to elucidate the relative contributions of myocardial structural changes, loading and hypertrophy to LV dysfunction in 113 patients: 85 with hypertensive LVH and 28 controls without LVH and with normal filling. Patients with normal dobutamine stress echocardiography and no history of coronary artery disease were selected, in order to exclude a contribution from ischaemia or scar. Abnormal LV filling was identified in 65 LVH patients, based on Doppler measurement of transmitral filling and annular velocities. All patients underwent grey-scale and colour tissue Doppler imaging from three apical views, which were stored and analysed off line. Integrated backscatter (113) and strain rate imaging were used to detect changes in structure and function; average cyclic variation of 113, strain rate and peak systolic strain were calculated by averaging each segment. Calibrated 113 intensity, corrected for pericardial 113 intensity, was measured in the septum and posterior wall from the parasternal long-axis view. Patients with LVH differed significantly from controls with respect to all backscatter and strain parameters, irrespective of the presence or absence of abnormal LV filling. LVH patients with and without abnormal LV filling differed with regard to age, LV mass and incidence of diabetes mellitus, but also showed significant differences in cyclic variation (P < 0.01), calibrated 113 in the posterior wall (P < 0.05) and strain rate (P < 0.01), although blood pressure, heart rate and LV systolic function were similar. Multivariate logistic regression analysis demonstrated that age, LV mass index and calibrated IB in the posterior wall were independent determinants of abnormal LV filling in patients with LVH. Thus structural and functional abnormalities can be detected in hypertensive patients with LVH with and without abnormal LV filling. In addition to age and LVH, structural (not functional) abnormalities are likely to contribute to abnormal LV filling, and may be an early sign of LV damage. 113 is useful for the detection of myocardial abnormalities in patients with hypertensive LVH.
Resumo:
Objectives To assess the detection rate of congenital fetal malformations and specific problems related to routine ultrasound screening in women with pre-existing diabetes. Methods A retrospective study was carried out to assess the performance of routine ultrasound screening in women with pre-existing diabetes (Types 1 and 2) within a tertiary institution. The incidence, type and risk factors for congenital fetal malformations were determined. The detection rate of fetal anomalies for diabetic women was compared with that for the low-risk population. Factors affecting these detection rates were evaluated. Results During the study period, 12 169 low-risk pregnant women and 130 women with pre-existing diabetes had routine ultrasound screening performed within the institution. A total of 10 major anomalies (7.7%) and three minor anomalies (2.3%) were present in the fetuses of the diabetic women. Central nervous system and cardiovascular system anomalies accounted for 60% of the major anomalies. Peri-conceptional hemoglobin A 1 c of more than 9% was associated with a high prevalence of major anomalies (14311000). Women who had fetuses with major anomalies bad a significantly higher incidence of obesity (78% vs. 37%; P < 0.05). Ultrasound examination of these diabetic pregnancies showed high incidences of suboptimal image quality (37%), incomplete examinations, and repeat examinations (17%). Compared to the 'low-risk' non-diabetic population from the same institution, the relative risk for a major congenital anomaly among the diabetic women was 5.9-fold higher (95% confidence interval, 2.9-11.9). The detection rate for major fetal anomalies was significantly lower for diabetic women (30% vs. 73%; P < 0.01), and the mean body mass index for the diabetic group was significantly higher (29 vs. 23 kg/m(2); P < 0.001). Conclusion The incidence of congenital anomalies is higher in diabetic pregnancies. Unfortunately, the detection rate for fetal anomalies by antenatal ultrasound scan was significantly, worse than that for the low-risk population. This is likely to be related to the maternal body habitus and unsatisfactory examinations. Methods to overcome these difficulties are discussed.
Resumo:
We compared the quality of realtime fetal ultrasound images transmitted using ISDN and IP networks. Four experienced obstetric ultrasound specialists viewed standard recordings in a randomized trial and rated the appearance of 30 fetal anatomical landmarks, each on a seven-point scale. A total of 12 evaluations were performed for various combinations of bandwidths (128, 384 or 768 kbit/s) and networks (ISDN or IF). The intraobserver coefficient of variation was 2.9%, 5.0%, 12.7% and 14.7% for the four observers. The mean overall ratings by each of the four observers were 4.6, 4.8, 5.0 and 5.3, respectively (a rating of 4 indicated satisfactory visualization and 7 indicated as good as the original recording). Analysis of variance showed that there were no significant interobserver variations nor significant differences in the mean scores for the different types of videoconferencing machines used. The most significant variable affecting the mean score was the bandwidth used. For ISDN, the mean score was 3.7 at 128 kbit/s, which was significantly worse than the mean score of 4.9 at 384 kbit/s, which was in turn significantly worse than the mean score of 5.9 at 768 kbit/s. The mean score for transmission using IP was about 0.5 points lower than that using ISDN across all the different bandwidths, but the differences were not significant. It appears that IP transmission in a private (non-shared) network is an acceptable alternative to ISDN for fetal tele-ultrasound and one deserving further study.
Resumo:
Most external assessments of cervical range of motion assess the upper and lower cervical regions simultaneously. This study investigated the within and between days reliability of the clinical method used to bias this movement to the upper cervical region, namely measuring rotation of the head and neck in a position of full cervical flexion. Measurements were made using the Fastrak measurement system and were conducted by one operator. Results indicated high levels of within and between days repeatability (range of ICC2,1 values: 0.85-0.95). The ranges of axial rotation to right and left, measured with the neck positioned in full flexion, were approximately 56% and 50%, respectively of total cervical rotation, which relates well to the proportional division of rotation in the upper and lower cervical regions. These results suggest that this method of measuring rotation would be appropriate for use in subject studies where movement dysfunction is present in the upper cervical region, such as those with cervicogenic headache. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
To investigate the ability of ultrasonography to estimate musactivity, we measured architectural parameters (pennation angles, fascicle lengths, and muscle thickness) of several human muscles (tibialis anterior, biceps brachii, brachialis, transversus abdominis, obliquus internus abdominis, and obliquus externus abdominis) during isometric contractions of from 0 to 100% maximal voluntary contraction (MVC). Concurrently, electromyographic (EMG) activity was measured with surface (tibialis anterior only) or fine-wire electrodes. Most architectural parameters changed markedly with contractions up to 30% MVC but changed little at higher levels of contraction. Thus, ultrasound imaging can be used to detect low levels of muscle activity but cannot discriminate between moderate and strong contractions. Ultrasound measures could reliably detect changes in EMG of as little as 4% MVC (biceps muscle thickness), 5% MVC (brachialis muscle thickness), or 9% MVC (tibialis anterior pennation angle). They were generally less sensitive to changes in abdominal muscle activity, but it was possible to reliably detect contractions of 12% MVC in transversus abdominis (muscle length) and 22% MVC in obliquus internus (muscle thickness). Obliquus externus abdominis thickness did not change consistently with muscle contraction, so ultrasound measures of thickness cannot be used to detect activity of this muscle. Ultrasound imaging can thus provide a non-invasive method of detecting isometric muscle contractions of certain individual muscles.
Resumo:
Pectus excavatum is the most common congenital deformity of the anterior thoracic wall. The surgical correction of such deformity, using Nuss procedure, consists in the placement of a personalized convex prosthesis into sub-sternal position to correct the deformity. The aim of this work is the CT-scan substitution by ultrasound imaging for the pre-operative diagnosis and pre-modeling of the prosthesis, in order to avoid patient radiation exposure. To accomplish this, ultrasound images are acquired along an axial plane, followed by a rigid registration method to obtain the spatial transformation between subsequent images. These images are overlapped to reconstruct an axial plane equivalent to a CT-slice. A phantom was used to conduct preliminary experiments and the achieved results were compared with the corresponding CT-data, showing that the proposed methodology can be capable to create a valid approximation of the anterior thoracic wall, which can be used to model/bend the prosthesis