486 resultados para 1036
Resumo:
Wydział Biologii: Instytut Biologii Eksperymentalnej
Resumo:
6 hojas.
Resumo:
http://www.archive.org/details/bordenesreligiosas01maasrich/
Resumo:
Quantum dashes are elongated quantum dots. Polarized edge-photovoltage and spontaneous emission spectroscopy are used to study the anisotropy of optical properties in 1.5μm InGaAsP and AlGaInAs-based quantum dash lasers. Strain, which causes TM-polarized transitions to be suppressed at the band edge, coupled with carrier confinement and dash shape leads to an enhancement of the optical properties for light polarized along the dash long axis, in excellent agreement with theoretical results. An analysis of the integrated facet and spontaneous emission rate with total current and temperature reveals that, in both undoped and p-doped InGaAsP-based quantum dash lasers at room temperature, the threshold current and its temperature dependence remain dominated by Auger recombination. We also identify two processes which can limit the output power and propose that the effects of the dopant in p-doped InGaAsP-based lasers dominate at low temperature but decrease with increasing temperature. A high threshold current density in undoped AlGaInAs-based quantum dash laser samples studied, which degrade rapidly at low temperature, is not due to intrinsic carrier recombination processes. 1.3μm GaAs-based quantum dots lasers have been widely studied, but there remains issues as to the nature of the electronic structure. Polarized edge-photovoltage spectroscopy is used to investigate the energy distribution and nature of the energy states in InAs/GaAs quantum dot material. A non-negligible TM-polarized transition, which is often neglected in calculations and analyses, is measured close to the main TE-polarized ground state transition. Theory is in very good agreement with the experimental results and indicates that the measured low-energy TM-polarized transition is due to the strong spatial overlap between the ground state electron and the light-hole component of a low-lying excited hole state. Further calculations suggest that the TM-polarized transition reduces at the band edge as the quantum dot aspect ratio decreases.
Resumo:
Soft X-ray transients (SXTs) are a subgroup of low-mass X-ray binaries consisting of a neutron star or a black hole and a companion low-mass star. SXTs exhibit a sudden outburst by increasing the luminosity from ∼ 1033 to ∼ 1036−38ergs1. After spending a few months in outburst, SXTs switch back to quiescence. Optical study of the binary system during the quiescence state of SXTs provides an opportunity to discriminate between BH binaries and neutron star binaries. The first part ot this research is composed of result of 10 years joint project between Hubble space telescope and Chandra, to study SXTs in M31. The other part of this thesis focused on the light curve of bright SXTs in M31. Disc irradiation is thought to be capable of explaining the global behaviour of the light curves of SXTs. Depending on the strength of the central X-ray emission in irradiating the disc, the light curve may exhibit an exponential or a linear decay. The model predicts that in brighter transients a transition from exponential decline to a linear one may be detectable. In this study, having excluded super-soft sources and hard X-ray transients, a sample of bright SXTs in M31 (Lpeak > 1038ergs1) has been studied. The expected change in the shape of the decay function is only observed in two of the light curves from the six light curves in the sample. Also, a systematic correlation between the shape of the light curve and the X-ray luminosity has not been seen.
Resumo:
Belying the spectacular success of solid organ transplantation and improvements in immunosuppressive therapy is the reality that long-term graft survival rates remain relatively unchanged, in large part due to chronic and insidious alloantibody-mediated graft injury. Half of heart transplant recipients develop chronic rejection within 10 years - a daunting statistic, particularly for young patients expecting to achieve longevity by enduring the rigors of a transplant. The current immunosuppressive pharmacopeia is relatively ineffective in preventing late alloantibody-associated chronic rejection. In this issue of the JCI, Kelishadi et al. report that preemptive deletion of B cells prior to heart transplantation in cynomolgus monkeys, in addition to conventional posttransplant immunosuppressive therapy with cyclosporine, markedly attenuated not only acute graft rejection but also alloantibody elaboration and chronic graft rejection. The success of this preemptive strike implies a central role for B cells in graft rejection, and this approach may help to delay or prevent chronic rejection after solid organ transplantation.
Resumo:
This paper presents both modelling and experimental test data to characterise the performance of four non-destructive tests. The focus is on determining the presence and rough magnitude of thermal fatigue cracks within the solder joints for a surface mount resistor on a strip of FR4 PCB. The tests all operate by applying mechanical loads to the PCB and monitoring the strain response at the top of the resistor. The modelling results show that of the four tests investigated, three are sensitive to the presence of a crack in the joint and its magnitude. Hence these tests show promise in being able to detect cracking caused by accelerated testing. The experimental data supports these results although more validation is required.
Resumo:
Rapid, quantitative SERS analysis of nicotine at ppm/ppb levels has been carried out using stable and inexpensive polymer-encapsulated Ag nanoparticles (gel-colls). The strongest nicotine band (1030 cm(-1)) was measured against d(5)-pyridine internal standard (974 cm(-1)) which was introduced during preparation of the stock gel-colls. Calibration plots of I-nic/I-pyr against the concentration of nicotine were non-linear but plotting I-nic/I-pyr against [nicotine](x) (x = 0.6-0.75, depending on the exact experimental conditions) gave linear calibrations over the range (0.1-10 ppm) with R-2 typically ca. 0.998. The RMS prediction error was found to be 0.10 ppm when the gel-colls were used for quantitative determination of unknown nicotine samples in 1-5 ppm level. The main advantages of the method are that the gel-colls constitute a highly stable and reproducible SERS medium that allows high throughput (50 sample h(-1)) measurements.
Resumo:
In this paper, the leaky-mode theory is applied to take into account for the dielectric losses in millimetre waveband inhomogeneous leaky-wave antennas. A practical dielectric-filled cosine-tapered periodic leaky-wave antenna working in the 45GHz band is studied, showing how the desired sidelobes level and directivity are spoilt due to the effect of the losses. An iterative procedure is used to correct the negative effects of the losses in the radiation patterns of the leaky-wave structure. It is also shown the practical limits of the proposed correction approach. The leaky-mode theory is applied for the first time to compensate the losses in a practical leaky-wave antenna in hybrid waveguide printed circuit technology. This leaky-mode theory is validated with full-wave three-dimensional finite element method simulations of the designed antenna.
Resumo:
The application of fine-grain pipelining techniques in the design of high-performance wave digital filters (WDFs) is described. The problems of latency in feedback loops can be significantly reduced if computations are organized most significant, as opposed to least significant, bit first and if the results are fed back as soon as they are formed. The result is that chips can be designed which offer significantly higher sampling rates than otherwise can be obtained using conventional methods. How these concepts can be extended to the more challenging problem of WDFs is discussed. It is shown that significant increases in the sampling rate of bit-parallel circuits can be achieved using most significant bit first arithmetic.
Resumo:
Objective: The aim of this study was to investigate the effect of pre-treatment verification imaging with megavoltage (MV) X-rays on cancer and normal cell survival in vitro and to compare the findings with theoretically modelled data. Since the dose received from pre-treatment imaging can be significant, incorporation of this dose at the planning stage of treatment has been suggested.
Methods: The impact of imaging dose incorporation on cell survival was investigated by clonogenic assay, irradiating DU-145 prostate cancer, H460 non-small cell lung cancer and AGO-1522b normal tissue fibroblast cells. Clinically relevant imaging-to-treatment times of 7.5 minutes and 15 minutes were chosen for this study. The theoretical magnitude of the loss of radiobiological efficacy due to sublethal damage repair was investigated using the Lea-Catcheside dose protraction factor model.
Results: For the cell lines investigated, the experimental data showed that imaging dose incorporation had no significant impact upon cell survival. These findings were in close agreement with the theoretical results.
Conclusions: For the conditions investigated, the results suggest that allowance for the imaging dose at the planning stage of treatment should not adversely affect treatment efficacy.
Advances in Knowledge: There is a paucity of data in the literature on imaging effects in radiotherapy. This paper presents a systematic study of imaging dose effects on cancer and normal cell survival, providing both theoretical and experimental evidence for clinically relevant imaging doses and imaging-to-treatment times. The data provide a firm foundation for further study into this highly relevant area of research.