968 resultados para wrist monitor
Resumo:
Completion of DNA replication before mitosis is essential for genome stability and cell viability. Cellular controls called checkpoints act as surveillance mechanisms capable of detecting errors and blocking cell cycle progression to allow time for those errors to be corrected. An important question in the cell cycle field is whether eukaryotic cells possess mechanisms that monitor ongoing DNA replication and make sure that all chromosomes are fully replicated before entering mitosis, that is whether a replication-completion checkpoint exists. From recent studies with smc5–smc6 mutants it appears that yeast cells can enter anaphase without noticing that replication in the ribosomal DNA array was unfinished. smc5–smc6 mutants are proficient in all known cellular checkpoints, namely the S phase checkpoint, DNA-damage checkpoint, and spindle checkpoint, thus suggesting that none of these checkpoints can monitor the presence of unreplicated segments or the unhindered progression of forks in rDNA. Therefore, these results strongly suggest that normal yeast cells do not contain a DNA replication-completion checkpoint.
Resumo:
BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.
Resumo:
Background: Antiretroviral therapy has changed the natural history of human immunodeficiency virus (HIV) infection in developed countries, where it has become a chronic disease. This clinical scenario requires a new approach to simplify follow-up appointments and facilitate access to healthcare professionals. Methodology: We developed a new internet-based home care model covering the entire management of chronic HIV-infected patients. This was called Virtual Hospital. We report the results of a prospective randomised study performed over two years, comparing standard care received by HIV-infected patients with Virtual Hospital care. HIV-infected patients with access to a computer and broadband were randomised to be monitored either through Virtual Hospital (Arm I) or through standard care at the day hospital (Arm II). After one year of follow up, patients switched their care to the other arm. Virtual Hospital offered four main services: Virtual Consultations, Telepharmacy, Virtual Library and Virtual Community. A technical and clinical evaluation of Virtual Hospital was carried out. Findings: Of the 83 randomised patients, 42 were monitored during the first year through Virtual Hospital (Arm I) and 41 through standard care (Arm II). Baseline characteristics of patients were similar in the two arms. The level of technical satisfaction with the virtual system was high: 85% of patients considered that Virtual Hospital improved their access to clinical data and they felt comfortable with the videoconference system. Neither clinical parameters [level of CD4 + T lymphocytes, proportion of patients with an undetectable level of viral load (p = 0.21) and compliance levels 90% (p = 0.58)] nor the evaluation of quality of life or psychological questionnaires changed significantly between the two types of care. Conclusions: Virtual Hospital is a feasible and safe tool for the multidisciplinary home care of chronic HIV patients. Telemedicine should be considered as an appropriate support service for the management of chronic HIV infection.
Resumo:
Brain injury is frequently observed after sepsis and may be primarily related to the direct effects of the septic insult on the brain (e.g., brain edema, ischemia, seizures) or to secondary/indirect injuries (e.g., hypotension, hypoxemia, hypocapnia, hyperglycemia). Management of brain injury in septic patients is first focused to exclude structural intracranial complications (e.g., ischemic/hemorrhagic stroke) and possible confounders (e.g., electrolyte alterations or metabolic disorders, such as dysglycemia). Sepsis-associated brain dysfunction is frequently a heterogeneous syndrome. Despite increasing understanding of main pathophysiologic determinants, therapy is essentially limited to protect the brain against further cerebral damage, by way of "simple" therapeutic manipulations of cerebral perfusion and oxygenation and by avoiding over-sedation. Non-invasive monitoring of cerebral perfusion and oxygenation with transcranial Doppler (TCD) and near-infrared spectroscopy (NIRS) is feasible in septic patients. Electroencephalography (EEG) allows detection of sepsis-related seizures and holds promise also as sedation monitoring. Brain CT-scan detects intra-cerebral structural lesions, while magnetic resonance imaging (MRI) provides important insights into primary mechanisms of sepsis-related direct brain injury, (e.g., cytotoxic vs. vasogenic edema) and the development of posterior reversible encephalopathy. Together with EEG and evoked potentials (EP), MRI is also important for coma prognostication. Emerging clinical evidence suggests monitoring of the brain in septic patients can be implemented in the ICU. The objective of this review was to summarize recent clinical data about the role of brain monitoring - including TCD, NIRS, EEG, EP, CT, and MRI - in patients with sepsis and to illustrate its potential utility for the diagnosis, management and prognostication.
Resumo:
RATIONALE: Limited-channel portable monitors (PMs) are increasingly used as an alternative to polysomnography (PSG) for the diagnosis of obstructive sleep apnoea (OSA). However, recommendations for the scoring of PM recordings are still lacking. Pulse-wave amplitude (PWA) drops, considered as surrogates for EEG arousals, may increase the detection sensitivity for respiratory events in PM recordings. OBJECTIVES: To investigate the performance of four different hypopnoea scoring criteria, using 3% or 4% oxygen desaturation levels, including or not PWA drops as surrogates for EEG arousals, and to determine the impact of measured versus reported sleep time on OSA diagnosis. METHODS: Subjects drawn from a population-based cohort underwent a complete home PSG. The PSG recordings were scored using the 2012 American Academy of Sleep Medicine criteria to determine the apnoea-hypopnoea index (AHI). Recordings were then rescored using only parameters available on type 3 PM devices according to different hypopnoea criteria and patients-reported sleep duration to determine the 'portable monitor AHIs' (PM-AHIs). MAIN RESULTS: 312 subjects were included. Overall, PM-AHIs showed a good concordance with the PSG-based AHI although it tended to slightly underestimate it. The PM-AHI using 3% desaturation without PWA drops showed the best diagnostic accuracy for AHI thresholds of ≥5/h and ≥15/h (correctly classifying 94.55% and 93.27% of subjects, respectively, vs 80.13% and 87.50% with PWA drops). There was a significant but modest correlation between PWA drops and EEG arousals (r=0.20, p=0.0004). CONCLUSION: Interpretation of PM recordings using hypopnoea criteria which include 3% desaturation without PWA drops as EEG arousal surrogate showed the best diagnosis accuracy compared with full PSG.
Resumo:
Wastewater-based epidemiology consists in acquiring relevant information about the lifestyle and health status of the population through the analysis of wastewater samples collected at the influent of a wastewater treatment plant. Whilst being a very young discipline, it has experienced an astonishing development since its firs application in 2005. The possibility to gather community-wide information about drug use has been among the major field of application. The wide resonance of the first results sparked the interest of scientists from various disciplines. Since then, research has broadened in innumerable directions. Although being praised as a revolutionary approach, there was a need to critically assess its added value, with regard to the existing indicators used to monitor illicit drug use. The main, and explicit, objective of this research was to evaluate the added value of wastewater-based epidemiology with regards to two particular, although interconnected, dimensions of illicit drug use. The first is related to trying to understand the added value of the discipline from an epidemiological, or societal, perspective. In other terms, to evaluate if and how it completes our current vision about the extent of illicit drug use at the population level, and if it can guide the planning of future prevention measures and drug policies. The second dimension is the criminal one, with a particular focus on the networks which develop around the large demand in illicit drugs. The goal here was to assess if wastewater-based epidemiology, combined to indicators stemming from the epidemiological dimension, could provide additional clues about the structure of drug distribution networks and the size of their market. This research had also an implicit objective, which focused on initiating the path of wastewater- based epidemiology at the Ecole des Sciences Criminelles of the University of Lausanne. This consisted in gathering the necessary knowledge about the collection, preparation, and analysis of wastewater samples and, most importantly, to understand how to interpret the acquired data and produce useful information. In the first phase of this research, it was possible to determine that ammonium loads, measured directly in the wastewater stream, could be used to monitor the dynamics of the population served by the wastewater treatment plant. Furthermore, it was shown that on the long term, the population did not have a substantial impact on consumption patterns measured through wastewater analysis. Focussing on methadone, for which precise prescription data was available, it was possible to show that reliable consumption estimates could be obtained via wastewater analysis. This allowed to validate the selected sampling strategy, which was then used to monitor the consumption of heroin, through the measurement of morphine. The latter, in combination to prescription and sales data, provided estimates of heroin consumption in line with other indicators. These results, combined to epidemiological data, highlighted the good correspondence between measurements and expectations and, furthermore, suggested that the dark figure of heroin users evading harm-reduction programs, which would thus not be measured by conventional indicators, is likely limited. In the third part, which consisted in a collaborative study aiming at extensively investigating geographical differences in drug use, wastewater analysis was shown to be a useful complement to existing indicators. In particular for stigmatised drugs, such as cocaine and heroin, it allowed to decipher the complex picture derived from surveys and crime statistics. Globally, it provided relevant information to better understand the drug market, both from an epidemiological and repressive perspective. The fourth part focused on cannabis and on the potential of combining wastewater and survey data to overcome some of their respective limitations. Using a hierarchical inference model, it was possible to refine current estimates of cannabis prevalence in the metropolitan area of Lausanne. Wastewater results suggested that the actual prevalence is substantially higher compared to existing figures, thus supporting the common belief that surveys tend to underestimate cannabis use. Whilst being affected by several biases, the information collected through surveys allowed to overcome some of the limitations linked to the analysis of cannabis markers in wastewater (i.e., stability and limited excretion data). These findings highlighted the importance and utility of combining wastewater-based epidemiology to existing indicators about drug use. Similarly, the fifth part of the research was centred on assessing the potential uses of wastewater-based epidemiology from a law enforcement perspective. Through three concrete examples, it was shown that results from wastewater analysis can be used to produce highly relevant intelligence, allowing drug enforcement to assess the structure and operations of drug distribution networks and, ultimately, guide their decisions at the tactical and/or operational level. Finally, the potential to implement wastewater-based epidemiology to monitor the use of harmful, prohibited and counterfeit pharmaceuticals was illustrated through the analysis of sibutramine, and its urinary metabolite, in wastewater samples. The results of this research have highlighted that wastewater-based epidemiology is a useful and powerful approach with numerous scopes. Faced with the complexity of measuring a hidden phenomenon like illicit drug use, it is a major addition to the panoply of existing indicators. -- L'épidémiologie basée sur l'analyse des eaux usées (ou, selon sa définition anglaise, « wastewater-based epidemiology ») consiste en l'acquisition d'informations portant sur le mode de vie et l'état de santé d'une population via l'analyse d'échantillons d'eaux usées récoltés à l'entrée des stations d'épuration. Bien qu'il s'agisse d'une discipline récente, elle a vécu des développements importants depuis sa première mise en oeuvre en 2005, notamment dans le domaine de l'analyse des résidus de stupéfiants. Suite aux retombées médiatiques des premiers résultats de ces analyses de métabolites dans les eaux usées, de nombreux scientifiques provenant de différentes disciplines ont rejoint les rangs de cette nouvelle discipline en développant plusieurs axes de recherche distincts. Bien que reconnu pour son coté objectif et révolutionnaire, il était nécessaire d'évaluer sa valeur ajoutée en regard des indicateurs couramment utilisés pour mesurer la consommation de stupéfiants. En se focalisant sur deux dimensions spécifiques de la consommation de stupéfiants, l'objectif principal de cette recherche était focalisé sur l'évaluation de la valeur ajoutée de l'épidémiologie basée sur l'analyse des eaux usées. La première dimension abordée était celle épidémiologique ou sociétale. En d'autres termes, il s'agissait de comprendre si et comment l'analyse des eaux usées permettait de compléter la vision actuelle sur la problématique, ainsi que déterminer son utilité dans la planification des mesures préventives et des politiques en matière de stupéfiants actuelles et futures. La seconde dimension abordée était celle criminelle, en particulier, l'étude des réseaux qui se développent autour du trafic de produits stupéfiants. L'objectif était de déterminer si cette nouvelle approche combinée aux indicateurs conventionnels, fournissait de nouveaux indices quant à la structure et l'organisation des réseaux de distribution ainsi que sur les dimensions du marché. Cette recherche avait aussi un objectif implicite, développer et d'évaluer la mise en place de l'épidémiologie basée sur l'analyse des eaux usées. En particulier, il s'agissait d'acquérir les connaissances nécessaires quant à la manière de collecter, traiter et analyser des échantillons d'eaux usées, mais surtout, de comprendre comment interpréter les données afin d'en extraire les informations les plus pertinentes. Dans la première phase de cette recherche, il y pu être mis en évidence que les charges en ammonium, mesurées directement dans les eaux usées permettait de suivre la dynamique des mouvements de la population contributrice aux eaux usées de la station d'épuration de la zone étudiée. De plus, il a pu être démontré que, sur le long terme, les mouvements de la population n'avaient pas d'influence substantielle sur le pattern de consommation mesuré dans les eaux usées. En se focalisant sur la méthadone, une substance pour laquelle des données précises sur le nombre de prescriptions étaient disponibles, il a pu être démontré que des estimations exactes sur la consommation pouvaient être tirées de l'analyse des eaux usées. Ceci a permis de valider la stratégie d'échantillonnage adoptée, qui, par le bais de la morphine, a ensuite été utilisée pour suivre la consommation d'héroïne. Combinée aux données de vente et de prescription, l'analyse de la morphine a permis d'obtenir des estimations sur la consommation d'héroïne en accord avec des indicateurs conventionnels. Ces résultats, combinés aux données épidémiologiques ont permis de montrer une bonne adéquation entre les projections des deux approches et ainsi démontrer que le chiffre noir des consommateurs qui échappent aux mesures de réduction de risque, et qui ne seraient donc pas mesurés par ces indicateurs, est vraisemblablement limité. La troisième partie du travail a été réalisée dans le cadre d'une étude collaborative qui avait pour but d'investiguer la valeur ajoutée de l'analyse des eaux usées à mettre en évidence des différences géographiques dans la consommation de stupéfiants. En particulier pour des substances stigmatisées, telles la cocaïne et l'héroïne, l'approche a permis d'objectiver et de préciser la vision obtenue avec les indicateurs traditionnels du type sondages ou les statistiques policières. Globalement, l'analyse des eaux usées s'est montrée être un outil très utile pour mieux comprendre le marché des stupéfiants, à la fois sous l'angle épidémiologique et répressif. La quatrième partie du travail était focalisée sur la problématique du cannabis ainsi que sur le potentiel de combiner l'analyse des eaux usées aux données de sondage afin de surmonter, en partie, leurs limitations. En utilisant un modèle d'inférence hiérarchique, il a été possible d'affiner les actuelles estimations sur la prévalence de l'utilisation de cannabis dans la zone métropolitaine de la ville de Lausanne. Les résultats ont démontré que celle-ci est plus haute que ce que l'on s'attendait, confirmant ainsi l'hypothèse que les sondages ont tendance à sous-estimer la consommation de cannabis. Bien que biaisés, les données récoltées par les sondages ont permis de surmonter certaines des limitations liées à l'analyse des marqueurs du cannabis dans les eaux usées (i.e., stabilité et manque de données sur l'excrétion). Ces résultats mettent en évidence l'importance et l'utilité de combiner les résultats de l'analyse des eaux usées aux indicateurs existants. De la même façon, la cinquième partie du travail était centrée sur l'apport de l'analyse des eaux usées du point de vue de la police. Au travers de trois exemples, l'utilisation de l'indicateur pour produire du renseignement concernant la structure et les activités des réseaux de distribution de stupéfiants, ainsi que pour guider les choix stratégiques et opérationnels de la police, a été mise en évidence. Dans la dernière partie, la possibilité d'utiliser cette approche pour suivre la consommation de produits pharmaceutiques dangereux, interdits ou contrefaits, a été démontrée par l'analyse dans les eaux usées de la sibutramine et ses métabolites. Les résultats de cette recherche ont mis en évidence que l'épidémiologie par l'analyse des eaux usées est une approche pertinente et puissante, ayant de nombreux domaines d'application. Face à la complexité de mesurer un phénomène caché comme la consommation de stupéfiants, la valeur ajoutée de cette approche a ainsi pu être démontrée.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
L’objectiu d’aquest projecte és desenvolupar una aplicació per a mòbils Android que permeti visualitzar missatges curts en un monitor d’ordinador o TV. Els missatges es gestionaran a partir d’una aplicació de mòbil que inclourà la generació, gestió i transmissió dels missatges al monitor
Resumo:
Controlar la frecuencia cardiaca fetal y la dinámica uterina durante el proceso del embarazo y el parto resulta de particular importancia para conocer el estado de salud de la madre y el niño. Hoy en día existen aparatos muy novedosos para este fin de uso generalizado en los hospitales españoles. De este tema se ocupa la Ficha de Utillaje de este mes analizando en qué consiste este monitor; cómo se utiliza, los pasos a seguir; etc.
Resumo:
Controlar la frecuencia cardiaca fetal y la dinámica uterina durante el proceso del embarazo y el parto resulta de particular importancia para conocer el estado de salud de la madre y el niño. Hoy en día existen aparatos muy novedosos para este fin de uso generalizado en los hospitales españoles. De este tema se ocupa la Ficha de Utillaje de este mes analizando en qué consiste este monitor; cómo se utiliza, los pasos a seguir; etc.
Resumo:
Controlar la frecuencia cardiaca fetal y la dinámica uterina durante el proceso del embarazo y el parto resulta de particular importancia para conocer el estado de salud de la madre y el niño. Hoy en día existen aparatos muy novedosos para este fin de uso generalizado en los hospitales españoles. De este tema se ocupa la Ficha de Utillaje de este mes analizando en qué consiste este monitor; cómo se utiliza, los pasos a seguir; etc.
Resumo:
Um dos entraves para a maior expansão da agricultura de precisão está, principalmente, no elevado custo dos equipamentos a serem utilizados. A geração de mapas de produtividade é a fase de mais fácil execução na agricultura de precisão. Entretanto, quando várias colhedoras operam simultaneamente em uma determinada área, nem sempre é possível dispor de monitores de colheita em todas as máquinas. Assim, neste trabalho, foi avaliado o decréscimo da precisão em mapas de produtividade obtidos a partir de áreas onde se utilizaram colhedoras não-equipadas com monitor de colheita associadas a colhedoras monitoradas. Também foram comparados os métodos de interpolação "inverso da distância ao quadrado" e "krigagem". Inicialmente, a interpolação do mapa com todos os pontos de amostragem (original) foi gerada e, a partir dessa, foi feita a eliminação de passadas de modo a obter os mapas simulados. Na comparação entre os mapas simulados e o original, foi utilizado o coeficiente de desvio relativo - CDR, e o índice kappa. O número de passadas eliminadas diminuiu a precisão dos mapas em ambos os métodos de interpolação. Sendo assim, a quantidade mínima necessária de monitores em um conjunto de colhedoras depende da precisão desejada. Portanto, as máquinas devem ser intercaladas de maneira que as amostras sejam coletadas uniformemente por toda a área a ser colhida.
Resumo:
12 x 20 cm