146 resultados para whiteness


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of high pressure homogenisation (HPH) and heat treatments on physicochemical properties and physical stability of almond and hazelnut milks was studied. Vegetable milks were obtained and homogenised by applying 62, 103 and 172 MPa (MF1, MF2 and MF3, respectively). Untreated and MF3 samples were also submitted to two different heat treatments (85 °C/30 min (LH) or 121 °C/15 min (HH)). Physical and structural properties of the products were greatly affected by heat treatments and HPH. In almond milk, homogenised samples showed a significant reduction in particle size, which turned from bimodal and polydisperse to monodisperse distributions. Particle surface charge, clarity and Whiteness Index were increased and physical stability of samples was improved, without affecting either viscosity or protein stability. Hazelnut beverages showed similar trends, but HPH notably increased their viscosity while change their rheological behaviour, which suggested changes in protein conformation. HH treatments caused an increment of particle size due to the formation oil droplet-protein body clusters, associated with protein denaturation. Samples submitted to the combined treatment MF3 and LH showed the greatest stability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate in vitro the effect of different in-office bleaching systems on the surface morphology of bovine dentin. Thirty tooth fragments measuring 4 x 4mm, containing enamel and dentin, were obtained from the crowns of extracted bovine incisors. Samples were subjected to simulated intracoronal bleaching techniques using conventional (Opalescence Endo (R) and Whiteness Super Endo (R)) and light-activated systems (Opalescence Xtra (R) and Whiteness HP Maxx (R)). Controls were treated with either sodium perborate mixed with 10% hydrogen peroxide or no bleaching agent. The samples were observed under SEM and the recorded images were evaluated for topographic alterations. The ultrastructural alterations of dentin observed in this study varied greatly between groups according to the products used. Higher pH products (Whiteness HP Maxx (R) and Opalescence Xtra (R)) associated with in-office techniques yielded better maintenance of dentin ultrastructure. Apparently, both low pH and hydrogen peroxide oxidation play a role in altering the ultrastructure of dentin during internal dental bleaching. The use of alkaline products with reduced time of application (in-office techniques) may decrease such morphological alterations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conqueror for Indigo is production treated with an active chemical to maximize the ink adhesion.ArjoWiggins has found that another chemical, the candidate compound, would improve the propertiesof the paper. ArjoWiggins therefore wish to replace the current compound. To strengthenthe patent requirements for ink adhesion needs to be determined. A theory is developed to whychemicals with certain properties maximize the ink adhesion. Experiments are performed but theresults are inaccurate. The reason for ink adhesion is still unknown.Paper treated with the candidate compound is produced in a production trial and the paper evaluated.The paper shows decreased ink adhesion compared to paper treated with current compoundbut gives higher whiteness, longer shelf life and the formulation is preferred by the milldue to health and safety reasons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project has been made in cooperation with Stora Enso Research Centre Falun (Research). Thebackground of the project is that Research has customers who demand a method to measure the quantityof varnish online in offset printing. The aim with the project is to investigate if any test method correlateswith the quantity of varnish and to improve the understanding of the variables in the varnishingunit. The goal with the project is to develop a functional method. Two printing trials have beenperformed. The aim with the first trial was to investigate how different factors in the printer influencedthe quantity of varnish using reduced factoranalysis. The aim of the second trial was to analyse onlya reduced numbers of factors in the varnishing unit. The methods that were used to measure the varnishingquantity are weighing, IR-analysis, gloss, whiteness and brightness. Results from the projectshow that the weighing method does not work in this study due to basis weight variations of the sheets.The results from weighing did not agree with the results from the other methods. On the other handthere is a strong correation between the IR- and the glossmethods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This degree project has been carried out on the commission of AB Borlänge Energi. The purpose of thisproject was to redesign the magazine Energitrycket. The magazine should inform about the current eventsat the company. The work consisted of redesign of the existing magazine and adjustment to copying andpublishing on the web.This project also contains a research about how paper and colour affect the print results. It shows thatthe maximum contrast and sharp image reproduction is best achieved on woodfree, coated, calenderedpaper with high whiteness. An uncoated, light yellow paper is however to recommend for a printed matterswith a lot of text.It also shows that every production unit reproduces colours differently. To get a good colour reproductionand a good communication between these units, they must be calibrated, and well-functioningICC-profiles must be created.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To make your company change from a conventional workflow to an ICC-based workflow you need tomake investments in time and money. On the other hand you get your reward in terms of a stable andquality safe production. To choose this way of adjusting your company to new routines requires accuracyas well as a great deal of commitment. It is not only about having the right equipment. There area lot of factors that affect the quality of production.Our ambition with this report is to bring out the importance of general thinking when it comes toICC-profiling and to discuss on which basis printing profiles should be created. Quality parameters asfor example roughness and whiteness of paper are also discussed. To be able to investigate these mattersin detail we have taken a closer look at two companies, which have chosen to commit themselvesto achive better quality through color management but still feel that they have some problems withtheir workflow.One of the conclusions that are made in this report is that both companies should extend their investmentsin education of employees to become less independent of consultants, but also to increase theinterest in changes within the company. It is also stressed that an ICC-profile only can be efficient if acompany commits itself to accuracy regarding routines, control and calibration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental bleaching is a simple and conservative procedure for aesthetic restoration of vital discoloured teeth. However, dental bleaching agents may represent a hazard to human health, especially by causing DNA strand breaks. Genotoxicity tests form an important part of cancer research and risk assessment of potential carcinogens. In the current study, the genotoxic potential associated with exposure to dental bleaching agents was assessed by the single cell gel (comet) assay in vitro. Six commercial dental bleaching agents (Clarigel Gold - Dentsply; Whitespeed - Discus Dental; Nite White - Discus Dental; Magic Bleaching - Vigodent; Whiteness HP - FGM and Lase Peroxide - DMC) were exposed to mouse lymphoma cells in vitro. The results pointed out that all dental bleaching agents tested contributed to the DNA damage as depicted by the mean tail moment. Clear concentration-related effects were obtained for DNA damaging, being the strongest effect observed at the highest dose of the hydrogen peroxide (Whiteness HP and Lase Peroxide, at 35% concentration). on the contrary, Whitespeed (Discus Dental) induced the lowest level of DNA breakage. Taken together, these results suggest that dental bleaching agents may be a factor that increases the level of DNA damage as detected by the single cell gel (comet) assay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The aim of this study was to assess the enamel microhardness treated with three in-office bleaching agents, containing 35% hydrogen peroxide with different acidity. Materials and methods. Bovine incisors were divided into three groups that received the following bleaching agents: Whiteness HP, Total Bleach and Opalescence Xtra. Three gel applications/10-min each, totaling 30-min of bleaching treatment, were made on the teeth and activated with a blue LED (1000 mW/470 nm) combined to a LASER (120 mW/795 nm) device (Easy Bleach-Clean Line). Vickers hardness (VH) was evaluated at baseline and after the bleaching procedure. The values of Hardness loss [HNL] (% reduction) were calculated. The two-sample t-test was used for comparison of the HNL of the three bleaching products (5% level of significance). Results. The Opalescence Xtra, which had the lowest pH value (pH = 4.30), showed a significant increase of HNL when compared with Total Bleach bleaching agent, which had the highest pH value (pH = 6.62). Conclusions. The 35% hydrogen peroxide bleaching agents resulted in a reduction in surface enamel microhardness and bleaching with the most acid agent resulted in a significant enamel hardness loss compared to the less acid agent (4.30 vs 6.62). Strategies proposed to reduce the enamel loss after bleaching treatment may include the use of daily fluoride therapy, mouth rinsing (fluoride, milk and sodium bicarbonate solution), fluoride/bicarbonate dentifrices without abrasives, do not toothbrush immediately after bleaching, fluorides and calcium add to bleaching agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental bleaching is a simple and conservative procedure for aesthetic restoration of vital and non-vital discolored teeth. Nevertheless, a number of studies have demonstrated the risk of tissue damage from the contact of these agents with the oral mucosa. In the current study, the genotoxic potential associated with exposure to dental bleaching agents was assessed by the single cell gel (comet) assay in vitro. Chinese hamster ovary (CHO) cells in vitro were exposed to six commercial dental bleaching agents (Clarigel Gold - Dentsply; Whitespeed - Discus Dental; Nite White - Discus Dental; Magic Bleaching - Vigodent; Whiteness HP - FGM and Lase Peroxide - DMC). The results pointed out that all dental bleaching agents tested contributed to DNA damage as depicted by the mean tail moment, being the strongest effect observed with the highest dose of hydrogen peroxide (Whiteness HP and Lase peroxide, at a 35% concentration). On the other hand, Magic Bleaching (Vigodent) induced the lowest level of DNA breakage. Negative and positive controls displayed absence and presence of DNA-damaging, respectively. Taken together, these results suggest that dental bleaching agents may be a factor that increases the level of DNA damage. A higher concentration of hydrogen peroxide produced higher noxious activities in the genome as detected by single cell gel (comet) assay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to evaluate the flexural resistance of three types of restorative materials: compomer (Freedom), resin-modified glass-ionomer (Vitremer) and composite resin (Esthet-X), observing whether the application of bleaching agent can cause alterations of their flexural properties. Sixty samples were made using a 10 x 1 x 1 mm brass mold, and divided into three groups: G1- Freedom (SDI); G2- Vitremer (3M ESPE); G3- Esthet-X (Dentsply). On half of the samples of each group (10 samples) the bleaching treatment was applied and the other half used as control, was stored in distilled water at a temperature of 37 degrees C. Whiteness HP Maxx bleaching system was applied on the sample surface following the manufacturer's recommendations, simulating the bleaching treatment at the clinic. After this period, a flexural strength (three-point bending) test was conducted using (EMIC DL 1000) machine until the samples fractured. The data were submitted to ANOVA and Tukey tests. Of the restorative materials studied, G3-(87.24 +/- 31.40 MPa) presented the highest flexural strength, followed by G1-(61.67 +/- 21.32 MPa) and G2-(61.67 +/- 21.32 MPa). There was a statistical difference in flexural strength after the bleaching treatment. It was concluded that the use of a beaching agent can promote significant alteration of the flexural strength of these restorative materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effects of five home bleaching products containing 15-16% carbamide peroxide on the microhardness of microhybrid composite resin Z-250 (3M/Espe). A total of 72 specimens were fabricated in cylindrical acrylic matrices (4 x 2 mm), filled with composite resin and photo-activated for 40 seconds. They were divided in 6 study groups (n = 12), according to the bleaching product: Review (SS White), Magic Bleaching (Vigodent), Opalescence (Ultradent), Whiteness Perfect (FGM), Claridex (Biodinâmica), and a control group (not bleached). Specimens were exposed to 1 cc of bleaching gel for 6 hours daily for 2 weeks. The control group specimens were kept in artificial saliva throughout this time. All the specimens were then analyzed in a microhardness tester. Knoop hardness measurements were performed, and the results were submitted to parametric statistical analysis (analysis of variance and Tukey's test). Mean Knoop values and standard deviation were: baseline, 68.52a (4.28); control, 63.42b (7.16); Whiteness Perfect, 57.57c (1.81); Magic Bleaching, 57.22c (3.84); Opalescence, 57.03cd (4.00); Claridex, 53.64de (3.33); Review 51.45e (2.82). Identical letters mean statistical equality according to Tukey's test at the 5% significance level. The products significantly decreased Z-250 (3M/Espe) microhardness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the effect of 10% and 16% carbamide peroxide bleaching agents on the surface microhardness of micro-particulate feldspathic ceramics (VM7 and VM13, Vita Zahnfabrik). Forty specimens (8-mm diameter, 2-mm thickness) were divided into four groups (n=10): GI-VM7 + 10% Whiteness, G2-VM7 + 16% Whiteness, G3-VM13 + 10% and G4-VM13 + 16% Whiteness. The home-use bleaching agents were applied for 8 hours on 15 days, and the specimens were stored in distilled water at 37 degrees C. The Vickers hardness number (HV) was determined for each specimen. Data were analyzed by the Wilcoxon and Mann-Whitney tests (p < 0.05). The microhardness values before exposure were: g1-433 (57); g2-486 (22); g3-509 (28); g4-518 (24), and after exposure: G1-349 (32); G2-496 (95); G3-519 (38); G4-502 (81). G2 exhibited a higher and significant difference than GI in VM7 groups, and the effect of bleaching concentration was shown to be significant by the Mann-Whitney test. And for VM13, both the Wilcoxon and Mann-Whitney tests showed no significant differences. When using 10% carbamide peroxide, the microhardness of VM7 ceramic was affected, and there were no effect on the microhardness between VM7 and VM13 ceramics when 16% carbamide peroxide was used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bleaching agents (10% and 16% carbamide peroxide) on the roughness of two dental ceramics in vitro, and to analyze the surface by scanning electronic microscopy (SEM). Two bleaching agents (10% and 16%/Whiteness, FGM Gel) and two microparticle feldspathic ceramics (Vita VM7 and Vita VM13) were used. Forty disks of Vita VM7 and Vita VM13 ceramic were manufactured, measuring 4 mm in diameter and 4 mm high, in accordance with the manufacturers' recommendations, and were divided into 4 groups (n = 10): (1) VM7 + Whiteness 10%; (2) VM7 + Whiteness 16%; (3) VM13 + Whiteness 10%; (4) VM13 + Whiteness 16%. The bleaching agent was applied for 8 hours a day for 15 days and during the intervals the test specimens were stored in distilled water at 37 degrees C. The roughness (Ra) of the test specimens was evaluated before and after exposure to the bleaching agents using a laser roughness meter and the topographic description was analyzed by SEM. The statistical analysis of roughness data showed significant differences in the VM7 groups, using paired t-test, p = 0.05 (VM7 + Whiteness 10%: p = 0.002; VM7 + Whiteness 16%: p = 0.001) and two-sample t-test (VM7 p = 0.047), and no significant difference was found among VM13 groups. The qualitative SEM analysis showed different degrees of surface changes. The results suggest that the roughness of the tested ceramic surfaces increased after exposure to the bleaching agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

People increasingly desire tooth whitening. Considering the wide range of whitening products on the market, this study evaluated the efficacy of whitening toothpastes and mouth rinses compared with the 10% carbamide peroxide (CP) whitening gel. We obtained 120 cylindrical specimens from bovine teeth, which were darkened for 24 hours in a coffee solution. The color measurement was performed by a spectrophotometer using the CIE L*a*b* system, and specimens were divided into six groups according to the use of the following agents: group 1, conventional fluoridated toothpaste; group 2, Close Up White Now; group 3, Listerine Whitening; group 4, Colgate Plax Whitening; group 5, experimental mouth rinse with Plasdone; and group 6, 10% CP Whiteness Perfect. After the simulation of 12 weeks of treatment for groups 1 to 5 and 14 days of treatment for group 6, the specimens were subjected to a new color reading. Data were subjected to one-way analysis of variance (α=0.05), which showed significant differences among groups after 12 weeks for ΔE (p=0.001). Results of the Tukey test revealed that groups 3, 4, and 6 presented significantly higher color alteration than groups 1, 2, and 5. The whitening toothpaste Close Up White Now and the experimental mouth rinse with Plasdone showed similar color alteration as conventional toothpaste after a 12-week treatment simulation. These groups presented significantly lower color alteration compared with whitening mouth rinses Listerine and Colgate Plax Whitening, which showed similar results to those observed after 14 days of bleaching with 10% CP treatment.