951 resultados para waste water sludge
Resumo:
The aim of this project was to evaluate the present state and possible changes of water resources in Lake Ladoga and its drainage basin for the purposes of the sustainable development of North-Western Russia and Finland. The group assessed the state of the water resources in quantitative and qualitative terms, taking the system of sustainable development indicators suggested by the International Commission on Sustainable Development as a basis for assessment. These include pressure indicators (annual withdrawals of ground and surface water, domestic consumption of water per capita), state indicators (ground water reserves, concentration of faecalcoliform in fresh water, biochemical oxygen demand), and response indicators (waste-water treatment coverage, density of hydrological networks). The group proposed the following additional indicators and indices for the complex evaluation of the qualitative and quantitative state of the region's water resources: * Pressure indicators (external load, coefficient of anthropogenic pressure) * State indicators and indices (concentrations of chemicals in water, concentrations of chemicals in sediments, index of water pollution, critical load, critical limit, internal load, load/critical load, concentration/critical limit, internal load/external load, trophic state, biotic indicators and indices) * Response indicators (discharges of pure water, polluted water, partly treated water and the ratio between these, trans-boundary fluxes of pollutants, state expenditure on environmental protection, human life span) The assessment considered both temporal and spatial aspects and produced a regional classification of the area according to the index of water pollution. Mathematical models were developed to describe and forecast the processes under way in the lake and can be used to estimate the influence of climatic changes on the hydrological regime, as well as the influence of anthropogenic load on the trophic state of Lake Ladoga and to assess the consequences of accidental discharges of polluting admixtures of different kinds into the lake. The results of this mathematical modelling may be of use to decision-makers responsible for the management of water resources.
Resumo:
Antibiotics are emerging contaminants worldwide. Due to insufficient policy regulations, public awareness, and the constant exposure of the environment to antibiotic sources has created a major environmental concern. Wastewater treatment plants (WWTP) are not equipped to filter-out these compounds before the discharge of the disinfected effluent into water sources (e.g., lakes and streams) and current available technologies are not equipped to remediate these compounds from environmental sources. Hence, the challenge remains to establish a biological system to remove these antibiotics from wastewater. An invitro hydroponic remediation system was developed using vetiver grass (Chrysopogon zizanioides L. Nash) to remediate tetracycline (TC) from water. Comparative metabolomics studies were conducted to investigate the metabolites/pathways associated with tetracycline metabolism in plants and TC-degrading bacteria. The results show that vetiver plants effectively uptake tetracycline from water sources. Vetiver root-associated bacteria recovered during the hydroponic remediation trial were highly tolerant to TC (as high as 600 ppm) and could use TC as a sole carbon and energy source. Growth conditions (pH, temperature, and oxygen requirement) for TC-tolerant bacteria were optimized for higher TC remediation capability from water sources. The plant (roots and shoots) and bacterial species were further characterized for the metabolites produced during the TC degradation process using GC-MS to identify the possible biochemical mechanism involved. Also, the plant root zone was screened for metabolites/enzymes that were secreted during antibiotic degradation and could potentially enhance the degradation process. The root zone was selected for this analysis because this region of the plant has shown a greater capacity for antibiotic degradation compared to the shoot zone. The role of antioxidant enzymes in TC degradation process revealed glutathione-S-transferase (GSTs) as an important group of enzymes in both plant and bacteria potentially involved in TC degradation process. Metabolomics results also suggest potential GST activity in the TC remediation/ transformation process used by plants. This information could be useful in gaining insights for the application of biological remediation systems for the mitigation of antibiotics from waste-water.
Resumo:
Two groundwater bodies, Grazer Feld and Leibnitzer Feld, with surface areas of 166 and 103 km2 respectively are characterised for the first time by measuring the combination of d18O/d2H, 3H/3He, 85Kr, CFC-11, CFC-12 and hydrochemistry in 34 monitoring wells in 2009/2010. The timescales of groundwater recharge have been characterised by 131 d18O measurements of well and surface water sampled on a seasonal basis. Most monitoring wells show a seasonal variation or indicate variable contributions of the main river Mur (0–30%, max. 70%) and/or other rivers having their recharge areas in higher altitudes. Combined d18O/d2H-measurements indicate that 65–75% of groundwater recharge in the unusual wet year of 2009 was from precipitation in the summer based on values from the Graz meteorological station. Monitoring wells downstream of gravel pit lakes show a clear evaporation trend. A boron–nitrate differentiation plot shows more frequent boron-rich water in the more urbanised Grazer Feld and more frequent nitrate-rich water in the more agricultural used Leibnitzer Feld indicating that a some of the nitrate load in the Grazer Feld comes from urban sewer water. Several lumped parameter models based on tritium input data from Graz and monthly data from the river Mur (Spielfeld) since 1977 yield a Mean Residence Time (MRT) for the Mur-water itself between 3 and 4 years in this area. Data from d18O, 3H/3He measurements at the Wagna lysimeter station supports the conclusion that 90% of the groundwaters in the Grazer Feld and 73% in the Leibnitzer Feld have MRTs of <5 years. Only in a few groundwaters were MRTs of 6–10 or 11–25 years as a result of either a long-distance water inflow in the basins or due to longer flow path in somewhat deeper wells (>20 m) with relative thicker unsaturated zones. The young MRT of groundwater from two monitoring wells in the Leibnitzer Feld was confirmed by 85Kr-measurements. Most CFC-11 and CFC-12 concentrations in the groundwater exceed the equilibration concentrations of modern concentrations in water and are therefore unsuitable for dating purposes. An enrichment factor up to 100 compared to atmospheric equilibrium concentrations and the obvious correlation of CFC-12 with SO4, Na, Cl and B in the ground waters of the Grazer Feld suggest that waste water in contact with CFC-containing material above and below ground is the source for the contamination. The dominance of very young groundwater (<5 years) indicates a recent origin of the contamination by nitrate and many other components observed in parts of the groundwater bodies. Rapid measures to reduce those sources are needed to mitigate against further deterioration of these waters.
Resumo:
Aquaponics is the science of integrating intensive fish aquaculture with plant production in recirculating water systems. Although ion waste production by fish cannot satisfy all plant requirements, less is known about the relationship between total feed provided for fish and the production of milliequivalents (mEq) of different macronutrients for plants, especially for nutrient flow hydroponics used for strawberry production in Spain. That knowledge is essential to consider the amount of macronutrients available in aquaculture systems so that farmers can estimate how much nutrient needs to be supplemented in the waste water from fish, to produce viable plant growth. In the present experiment, tilapia (Oreochromis niloticus L.) were grown in a small-scale recirculating system at two different densities while growth and feed consumption were noted every week for five weeks. At the same time points, water samples were taken to measure pH, EC25, HCO3 – , Cl – , NH4 + , NO2 – , NO3 – , H2PO4 – , SO4 2– , Na + , K+ , Ca 2+ and Mg 2+ build up. The total increase in mEq of each ion per kg of feed provided to the fish was highest for NO3 - , followed, in decreasing order, by Ca 2+ , H2PO4 – , K+ , Mg 2+ and SO4 2– . The total amount of feed required per mEq ranged from 1.61- 13.1 kg for the four most abundant ions (NO3 – , Ca 2+ , H2PO4 – and K+ ) at a density of 2 kg fish m–3 , suggesting that it would be rather easy to maintain small populations of fish to reduce the cost of hydroponic solution supplementation for strawberries.
Resumo:
This paper explores the water-energy nexus of Spain and offers calculations for both the energy used in the water sector and the water required to run the energy sector. The article takes a prospective approach, offering evaluations of policy objectives for biofuels and expected renewable energy sources. Approximately 5.8% of total electricity demand in Spain is due to the water sector. Irrigated agriculture is one of the Spanish water sectors that show the largest growth in energy requirements. Searches for more efficient modes of farm water use, urban waste water treatment, and the use of desalinated water must henceforth include the energy component. Furthermore, biofuel production, to the levels targeted for 2020, would have an unbearable impact on the already stressed water resources in Spain. However, growing usage of renewable energy sources is not threatened by water scarcity, but legislative measures in water allocation and water markets will be required to meet the requirements of using these sources. Some of these measures, which are pushed by regional governments, are discussed in concluding sections.
Resumo:
En este trabajo, se han llevado a cabo distintos experimentos en laboratorio, con el objetivo de estudiar el efecto de la aplicación de residuos orgánicos como fuentes de P en las pérdidas de este elemento, que se producen en suelo, tanto por escorrentía superficial como por lixiviación. El interés por evaluar las pérdidas de P se debe a la necesidad de conocer mejor los factores que influyen en los procesos de pérdidas de este elemento y así, poder reducir los problemas de eutrofización de aguas, tanto superficiales como subterráneas, provocadas por un exceso de este nutriente, junto con otros como el nitrógeno. Los trabajos experimentales que se han llevado a cabo se detallan a continuación: Se ha realizado el estudio de las formas de P contenidas en una serie de 14 residuos orgánicos, de distinto origen y tratamiento (compost, lodos, purines y digestato), comparando la información aportada por tres protocolos de fraccionamientos de P diferentes, seleccionados entre los principales métodos utilizados: protocolo de fraccionamiento de Ruttemberg (1992), protocolo de Normas, medidas y ensayos (Ruban et al., 2001a) y protocolo de Huang et al. (2008). Todos los métodos de fraccionamiento empleados aportaron información útil para conocer las formas de P de los residuos, a pesar de que alguno de ellos fue descrito para sedimentos o suelos. Sin embargo, resulta difícil comparar los resultados entre unos y otros, ya que cada uno emplea extractantes y tiempos de ensayos diferentes. Las cantidades de P total determinadas por cada método mantienen una relación lineal, aunque el método SMT, por ser más directo, obtiene las cantidades más elevadas para todos los residuos. Los métodos secuenciales (métodos de Huang y Ruttemberg), a pesar de ser más largos y tediosos, aportan información más detallada de la disponibilidad de las formas de P, y con ello, permiten obtener una mejor estimación de las pérdidas potenciales de este elemento tras su aplicación en suelo. Se han encontrado relaciones positivas entre las fracciones determinadas por estos dos métodos. Así mismo, se encuentra una correlación entre las formas solubles de P y la concentración de los iones [Ca + Fe + Al] de los residuos, útiles como indicadores de la disponibilidad de este elemento. Sin embargo, el protocolo SMT, no obtiene información de la solubilidad o disponibilidad de las formas de P contenidas, ni las formas determinadas mantienen relaciones directas con las de los otros métodos, con excepción del P total. Para el estudio del comportamiento de los residuos aplicados en suelos, se pusieron a punto sistemas de lluvia simulada, con el objetivo de caracterizar las pérdidas de P en la escorrentía superficial generada. Por otra parte, se emplearon columnas de suelos enmendados con residuos orgánicos, para el estudio de las pérdidas de P por lixiviación. Los ensayos de simulación de lluvia se llevaron a cabo de acuerdo al “National Phosphorus Research proyect“ (2001), que consigue simular eventos sucesivos de lluvia en unas condiciones semejantes a la realidad, empleando cajas llenas de suelo del horizonte superficial, con residuos aplicados tanto superficialmente como mediante mezcla con el propio suelo. Los ensayos se realizaron con seis residuos de diferente naturaleza y sometidos a distintos tratamientos. Se encontraron diferencias significativas en las pérdidas de las formas de P analizadas, tanto disueltas como particuladas, en las aguas de escorrentía generadas. En general, las pérdidas en el primer evento de lluvia tras la aplicación de los residuos fueron mayores a las generadas en el segundo evento, predominando las formas de P particuladas respecto a las disueltas en ambos. Se encontró una relación positiva entre las pérdidas de P en las aguas de escorrentía generadas en cada ensayo, con los contenidos de P soluble en agua y fácilmente disponible de los residuos empleados, determinados por los protocolos de fraccionamientos secuenciales. Además, se emplearon los modelos matemáticos desarrollados por Vadas et al. (2005, 2007), de evaluación de las pérdidas de P por escorrentía para fertilizantes y estiércoles. La predicción de estos modelos no se cumple en el caso de todos los residuos. Las distintas propiedades físicas de los residuos pueden afectar a las diferencias entre las pérdidas experimentales y las esperadas. Los ensayos de simulación del proceso de lixiviación se llevaron a cabo en columnas de percolación, con suelos enmendados con residuos orgánicos, de acuerdo a la norma “CEN/TS 14405–2004: Caracterización de los residuos – Test de comportamiento de lixiviación – Test de flujo ascendente”. Las pérdidas de P por procesos de lixiviación de agua, han sido despreciadas durante mucho tiempo respecto a las pérdidas por escorrentía. Sin embargo, se ha demostrado que deben tenerse en consideración, principalmente en algunos tipos de suelos o zonas cercanas a acuíferos. Se utilizaron tres suelos de distinta procedencia para los ensayos, de manera que se pudo estudiar la influencia del tipo de suelo en las pérdidas de P para cada tipo de residuo (purín, compost, digestato y lodo de EDAR). Los índices de adsorción de P determinados para cada suelo permiten evaluar aquellos que presentarán más riesgo de producir pérdidas de este elemento al aplicarse fuentes externas de P, encontrando una relación positiva entre ambos. Las pérdidas de P en los lixiviados varían en función tanto del residuo como del suelo empleado. Para el compost, el purín y el lodo, se encontró una relación entre las pérdidas generadas en el agua lixiviada de las columnas y las formas de P soluble contenidas en los residuos. Sin embargo, en el caso del digestato, no existía esta correlación. Las pérdidas para este residuo fueron en todos los casos menores a las estimadas, considerando las formas de P contenido. El estudio de la mojabilidad, propiedad física del residuo que evalúa la capacidad de interacción residuo-agua, permitió explicar el comportamiento anómalo de este residuo, con una mayor resistencia a que el agua entrara en su estructura y por tanto, una mayor dificultad de solubilizar el P contenido en el propio residuo, que en el caso de otros residuos. En general, podemos considerar que el estudio de las formas de P más disponibles o solubles en agua, aporta información útil de las pérdidas potenciales de P. Sin embargo, es necesario estudiar las propiedades físicas de los residuos orgánicos aplicados y la capacidad de adsorción de P de los suelos, para estimar las pérdidas de P y con ello, colaborar a controlar los procesos de eutrofización en aguas. ABSTRACT This dissertation explores the effect of organic wastes application as sources of P in losses of this element that occur by both surface runoff and leaching in soil. To do so, diverse laboratory experiments are conducted and presented here. Evaluating P losses is necessary to better understand the factors that influence the processes behind the loss of this element. Reducing P losses reduces eutrophication problems of both surface water and groundwater caused by an excess of this nutrient, along with other as nitrogen. Details of the experiments are presented below: The first experiment studies the forms of P contained in a series of 14 organic wastes of different origin and treatment (compost, sludge, slurry and digestate), comparing the information provided by three methods of P fractionation. The methods selected were: Ruttemberg protocol (1992); Standards, Measurements and Testing protocol (Ruban et al., 2001a); and Huang protocol (Huang et al., 2008). All fractionation methods employed successfully contribute to our knowledge of P forms in wastes, even though one of them was originally described for sediments or soils information. However, it is difficult to compare results among each other, as each protocol employs different extractants and time in the trials. Total amounts of P obtained by each method show a linear relationship, although the SMT method, which is more direct, obtains the highest amounts for all residues. Sequential methods (Huang and Ruttemberg’s protocols), despite being longer and more tedious, provide more detailed information on the availability of the forms of P. Therefore, allow the estimation of the potential losses of P after application in soil. Furthermore, positive relationships have been found among fractions obtained by these methods. Positive relationship has been found also among soluble forms of P and the concentration of ions Fe + Ca + Al, which is useful as an indicator of the availability of this element. However, the SMT protocol does not collect information about solubility or availability of forms of P contained; neither do certain forms maintain direct relations with the forms from other methods, with the exception of total P methods. To study the behavior of wastes applied to soils two experiments were conducted. Simulated rain systems were prepared to characterize P losses in the surface runoff generated. In addition, columns of soils amended with organic waste were developed for the study of P leaching losses. Simulated rain systems were carried out according to the ’National Phosphorus Research Project’ (2001), which manages to simulate successive rainfall events in conditions resembling reality. The experiment uses boxes filled with soil from the surface horizon amended with residues, both superficially and by mixing with the soil. Tests were conducted with six residues of different type and subjected to diverse treatments. Findings show significant differences in losses of the P forms analyzed in the generated runoff water, in both solution and particulate forms. In general, losses in the first rainfall event after application of waste were higher than the losses generated in the second event, predominating particulate forms of P over dissolved forms in both events. In all trials, a positive relationship was found between various P forms determined by sequential fractionation protocols (water soluble P and readily available P forms) and P losses in runoff. Furthermore, results from Vadas´s mathematical models (Vadas et al., 2005; 2007) to assess P losses by runoff fertilizers and manures indicate that the prediction of this model is not fulfilled in the case of all residues. The diverse physical properties of wastes may affect the differences between experimental and expected losses. Finally, leaching simulation processes were carried out in percolation columns, filled with soils amended with organic wastes, following the ‘CEN/TS 14405-2004 standard: Characterization of waste - Leaching behavior test - Test Flow ascending ’. P losses by leaching have been neglected for a long time with respect to runoff losses. However, findings corroborate previous studies showing that these P losses have to be taken into account, especially in certain types of soils and in zones near aquifers. To study the influence of soil type on P losses, experiments were carried out with three different soils and for each type of waste (manure, compost, digestate and sludge WWTP). Each soil’s P adsorption rates allow assessing which soils imply a higher risk of P losses when external sources of P are applied. P losses in leachate vary according to the type of soil employed and according to the specific residue. In the case of compost, manure and sludge, there is a relationship between leaching losses and residues’ soluble forms of P. The exception being the digestate, where there was no such correlation. Digestate P losses by leaching were lower than expected in all cases considering the forms of P contained. Moreover, examining digestate wettability -- that is, the physical property of the residue that assesses the capacity of waste-water interaction -- allowed explaining the anomalous behavior of this residue. Digestate has a high resistance to water entering its structure and thus higher difficulty to solubilize the P contained. Overall, studying the more available or soluble P forms provides useful information about the potential loss of P. However, this dissertation shows that it is necessary to examine the physical properties of organic residues applied as well as the P adsorption capacity of soils to estimate P losses, and thus to control eutrophication in water.
Resumo:
Este trabajo tiene por objeto la implementación del modelo ADM1 (The IWA Anaerobic Digestion Model No.1), para evaluar su capacidad de simular el proceso de digestión anaerobia de lodos de agua residual. Para implementar el modelo ADM1 se eligió el software Matlab y su herramienta Simulink, por su capacidad para simular sistemas dinámicos. Los resultados demostraron que la simulación a través de la implementación del modelo ADM1, es capaz de predecir la mayoría de los valores medios correspondientes a los parámetros de control más comunes del proceso de digestión anaerobia que se lleva a cabo en la Estación de depuración de aguas residuales (EDAR) sur de Madrid. Se deduce del estudio que la implementación del modelo ADM1 desarrollada mediante Matlab/Simulink, es capaz de simular el proceso dinámico de digestión anaerobia de cualquier EDAR, si se ajustan algunos de los parámetros del modelo para cada caso concreto. Abstract This work aims at the implementation of The IWA Anaerobic Digestion Model No.1 (ADM1) in order to assess its ability to simulate the anaerobic digestion process of wastewater sludge. A Matlab/Simulink implementation of the ADM1 was developed, the simulations results shows that the ADM1 is able to predict the average values of the most common control parameters of the anaerobic digestion process that takes place in the Waste water treatment plant (WWTP) south of Madrid. It is deduced of the estudy that the Matlab implementation of the ADM1 developed, is able to simulate the anaerobic digestion dynamic process of a WWTP, if some of the model parameters are fitted for each specific case.
Resumo:
Debido al gran interés existente en el ahorro y recuperación de energía, y en el deseo de obtener productos que permitan usos beneficiosos del fango procedente de la depuración del agua residual, la digestión anaerobia es el proceso de estabilización de uso más extendido. El tiempo de retención de sólidos es un factor clave en el proceso de digestión anaerobia. En base al tiempo de retención de sólidos, se dimensiona el volumen de los digestores anaerobios para así obtener la reducción de materia orgánica deseada, con la correspondiente producción de biogás. La geometría del digestor y su sistema de agitación deben ser adecuados para alcanzar el tiempo de retención de sólidos de diseño. Los primeros trabajos sobre la agitación de los digestores realizaban únicamente experimentos con trazadores y otros métodos de medición. En otros casos, la mezcla era evaluada mediante la producción de biogás. Estas técnicas tenían el gran hándicap de no conocer lo que sucedía realmente dentro del digestor y sólo daban una idea aproximada de su funcionamiento. Mediante aplicación de la mecánica de fluidos computacional (CFD) es posible conocer con detalle las características del fluido objeto de estudio y, por lo tanto, simular perfectamente el movimiento del fango de un digestor anaerobio. En esta tesis se han simulado mediante CFD diferentes digestores a escala real (unos 2000 m3 de volumen) agitados con bomba/s de recirculación para alcanzar los siguientes objetivos: establecer la influencia de la relación entre el diámetro y la altura, de la pendiente de la solera, del número de bombas y del caudal de recirculación en dichos digestores, definir el campo de velocidades en la masa de fango y realizar un análisis energético y económico. Así, es posible conocer mejor cómo funciona el sistema de agitación de un digestor anaerobio a escala real equipado con bomba/s de recirculación. Los resultados obtenidos muestran que una relación diámetro/altura del digestor por encima de 1 empeora la agitación del mismo y que la pendiente en la solera del digestor favorece que la masa de fango esté mejor mezclada, siendo más determinante la esbeltez del tanque que la pendiente de su solera. No obstante, también es necesario elegir adecuadamente los parámetros de diseño del sistema de agitación, en este caso el caudal de recirculación de fango, para obtener una agitación completa sin apenas zonas muertas. En el caso de un digestor con una geometría inadecuada es posible mejorar su agitación aumentando el número de bombas de recirculación y el caudal de las mismas, pero no se llegará a alcanzar una agitación total de la masa de fango debido a su mal diseño original. Anaerobic digestion is the process for waste water treatment sludge stabilization of more widespread use due to the huge interest in saving and recovering energy and the wish to obtain products that allow beneficial uses for the sludge. The solids retention time is a key factor in the anaerobic digestion. Based on the solids retention time, volume anaerobic digester is sized to obtain the desired reduction in organic matter, with the corresponding production of biogas. The geometry of the digester and the stirring system should be adequate to achieve the design solid retention time. Early works on digesters stirring just performed tracer experiments and other measurement methods. In other cases, mixing was evaluated by biogas production. These techniques had the great handicap of not knowing what really happened inside the digester and they only gave a rough idea of its operation. By application of computational fluid dynamics (CFD), it is possible to know in detail the characteristics of the fluid under study and, therefore, simulate perfectly the sludge movement of an anaerobic digester. Different full-scale digesters (about 2000 m3 of volume) agitated with pump/s recirculation have been simulated by CFD in this thesis to achieve the following objectives: to establish the influence of the relationship between the diameter and height, the slope of the bottom, the number of pumps and the recirculation flow in such digesters, to define the velocity field in the mass of sludge and carry out an energy and economic analysis. Thus, it is possible to understand better how the agitation system of a full-scale anaerobic digester equipped with pump/s recirculation works. The results achieved show that a diameter/height ratio of the digester above 1 worsens its stirring and that the slope of the digester bottom favors that the mass of sludge is better mixed, being more decisive the tank slenderness than the slope of its bottom. However, it is also necessary to select properly the design parameters of the agitation system, in this case the sludge recirculation flow rate, for a complete agitation with little dead zones. In the case of a digester with inadequate geometry, its agitation can be improved by increasing the number of recirculation pumps and flow of them, but it will not reach a full agitation of the mass of sludge because of the poor original design.
Resumo:
En el estado de Veracruz, al sur de México, se ubican empresas dedicadas a la obtención de etanol a partir de melaza de azúcar de caña. Las más pequeñas, tienen una producción promedio de 20,000 L de alcohol/día. Los efluentes de la producción de etanol incluyen agua de enfriamiento de condensadores, agua del lavado de tanques de fermentación y vinazas, estas últimas son los efluentes más contaminantes en las destilerías, por su concentración de material orgánico biodegradable y no biodegradable. Las vinazas se generan en grandes volúmenes, produciéndose de 12 a 15 litros de vinazas por cada litro de alcohol destilado. Estos efluentes se caracterizan por tener altas temperaturas, pH ácido y una elevada concentración de DQO así como de sólidos totales. La determinación de la biodegradabilidad anaerobia de un agua residual, permite estimar la fracción de DQO que puede ser transformada potencialmente en metano y la DQO recalcitrante que queda en el efluente. Para el desarrollo de una prueba de biodegradabilidad, es importante considerar diversos factores relacionados con la composición del agua a tratar, composición de los lodos y las condiciones bajo las cuales se lleva a cabo la prueba. La digestión anaerobia de aguas residuales industriales es comúnmente usada en todo el mundo, ofrece significativas ventajas para el tratamiento de efluentes altamente cargados. Los sistemas anaerobios de tratamiento de aguas residuales industriales incluyen tecnologías con biopelículas, estos sistemas de tratamiento anaerobio con biopelícula son una tecnología bien establecida para el tratamiento de efluentes industriales. El Reactor de Lecho Fluidizado Inverso Anaerobio (LFI) ha sido diseñado para el tratamiento de aguas residuales de alta carga, teniendo como ventajas el empleo de un soporte que proporciona una gran superficie y un bajo requerimiento de energía para la fluidización del lecho. En el presente trabajo, se lleva a cabo el análisis de un proceso de producción de etanol, identificando a los efluentes que se generan en el mismo. Se encuentra que el efluente final está compuesto principalmente por las vinazas provenientes del proceso de destilación. En la caracterización de las vinazas provenientes del proceso de producción de etanol a partir de melaza de azúcar de caña, se encontraron valores promedio de DQO de 193.35 gDQO/L, para los sólidos totales 109.78 gST/L y pH de 4.64. Así mismo, en esta investigación se llevó a cabo una prueba de biodegradabilidad anaerobia, aplicada a la vinaza proveniente de la producción de etanol. En la caracterización de los lodos empleados en el ensayo se obtiene una Actividad Metanogénica Especifica de 0.14 g DQO/gSSV.d. El porcentaje de remoción de DQO de la vinaza fue de 62.7%, obteniéndose una k igual a 0.031 h-1 y una taza de consumo de sustrato de 1.26 gDQO/d. El rendimiento de metano fue de 0.19 LCH4/g DQOremovida y el porcentaje de biodegradabilidad de 54.1%. El presente trabajo también evalúa el desempeño de un LFI, empleando Extendospher® como soporte y tratando efluentes provenientes de la producción de etanol. El reactor se arrancó en batch y posteriormente se operó en continuo a diferentes Cargas Orgánicas Volumétricas de 0.5, 1.0, 3.3, 6.8 y 10.4 g DQO/L.d. Además, se evaluaron diferentes Tiempos de Residencia Hidráulica de 10, 5 y 1 días. El sistema alcanzó las siguientes eficiencias promedio de remoción de DQO: 81% para la operación en batch; 58, 67, 59 y 50 % para las cargas de 0.5, 1.0, 3.3, 6.8 g DQO/L.d respectivamente. Para la carga de 10.4 g DQO/L.d, la eficiencia promedio de remoción de DQO fue 38%, en esta condición el reactor presentó inestabilidad y disminución del rendimiento de metano. La generación de metano inició hasta los 110 días de operación del reactor a una carga de 1.0 g DQO/L.d. El sistema alcanzó un rendimiento de metano desde 0.15 hasta 0.34 LCH4/g DQO. Durante la operación del reactor a una carga constante de 6.4 g DQO/L.d, y un TRH de 1 día, se alcanzó una eficiencia promedio de remoción de DQO de 52%. In the state of Veracruz, to the south of Mexico, there are located companies dedicated to the production of ethanol from molasses of cane sugar. The smallest, have a average production of 20,000 L ethanol/day. The effluent of production of ethanol include water of condensers, water originated from the cleanliness of tanks of fermentation and vinasses, the above mentioned are more effluent pollutants in the distilleries, for the poor organic matter degradability. The vinasses are generated in high volumes, producing from 12 to 15 L of vinasses per every liter of distilled ethanol. These effluent are characterized by its high temperature, pH acid and a high concentration of DQO as well as high concentration of TS. The determination of the anaerobic degradability of a waste water, it allows to estimate the fraction of DQO that can be transformed potentially into methane and the recalcitrant DQO that stays in the effluent. For the development of degradability test, it is important to consider factors related to the composition of the water to be treated, composition of the sludge and the conditions under which the test is carried out. The anaerobic digestion of industrial wastes water is used commonly in the whole world, it offers significant advantages for the treatment of effluent highly loaded. The anaerobic treatment of industrial wastes water include technologies with biofilms, this anaerobic treatment whit biofilms systems, is a well-established technology for treatment of industrial effluents. The Anaerobic Inverse Fluidized Bed Reactor (IFBR) has been developed to provide biological treatment of high strength organic wastewater for their large specific surface and their low energy requirements for fluidization. In this work, there is carried out the analysis of a process of production of ethanol, identifying the effluent ones that are generated in the process. One determined that the effluent end is composed principally by the vinasses originated from the process of distillation. In the characterization of the vinasses originated from the process of production of ethanol from cane sugar molasses, there were average values of DQO of 193.35 gDQO/L, average values of solid of 109.78 gST/L and pH of 4.64. In this investigation there was carried out a anaerobic degradability test of the vinasses generated in the production of ethanol. In the characterization of the sludge used in the essay, the specific methanogenic activity (SMA) was 0.14 gDQO/gSSV.d. The average removal of DQO of the vinasses was 62.7 %, k equal to 0.031 h-1 was obtained one and a rate of removal substrate of 1.26 gDQO/d. The methane yield was 0.19 LCH4/gDQO removed and the anaerobic biodegradability was a 54.1 %. This study describes the performance of IFBR with Extendospher®, for the treatment of vinasses. The start-up was made in batch, increasing gradually the Organic Load Rate (OLR): 0.5, 1.0, 3.3, 6.8 and 10.4 g COD/L.d. Different Hydraulic Retention Times (HRT) were evaluated: 10, 5 and 1 days. During the operation in batch, the COD removal obtained was of 81 %, and for OLR of 0.5, 1.0, 3.3, 6.8 g COD/L.d the removal obtained was 58, 67, 59 and 50 % respectively. For a maximum OLR of 10.4 g COD/L.d, the COD removal was 38 %, and the system presented instability and decrease of the yield methane. The methane production initiated after 110 days of the start-up of the IFBR, to organic load rate of 1.0 g COD/L.d. The system reached values in the methane yield from 0.15 up to 0.34 LCH4/g CODremoved, for the different organic load rates. During the operation to a constant OLR of 6.4 g COD/L.d, and a HRT of 1 day, the Anaerobic Inverse Fluidized Bed Reactor reached a maximum efficiency of removal of 52 %.
Resumo:
Mode of access: Internet.
Resumo:
"Project 86/7005."
Resumo:
Mode of access: Internet.
Resumo:
This paper addresses advanced control of a biological nutrient removal (BNR) activated sludge process. Based on a previously validated distributed parameter model of the BNR activated sludge process, we present robust multivariable controller designs for the process, involving loop shaping of plant model, robust stability and performance analyses. Results from three design case studies showed that a multivariable controller with stability margins of 0.163, 0.492 and 1.062 measured by the normalised coprime factor, multiplicative and additive uncertainties respectively give the best results for meeting performance robustness specifications. The controller robustly stabilises effluent nutrients in the presence of uncertainties with the behaviour of phosphorus accumulating organisms as well as to effectively attenuate major disturbances introduced as step changes. This study also shows that, performance of the multivariable robust controller is superior to multi-loops SISO PI controllers for regulating the BNR activated sludge process in terms of robust stability and performance and controlling the process using inlet feed flowrate is infeasible. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
The spatial arrangement and metabolic activity of 'Candidatus Competibacter phosphatis' was investigated in granular sludge from an anaerobic-aerobic sequencing batch reactor enriched for glycogen-accumulating organisms. In this process, the electron donor (acetate) and the electron acceptor (oxygen) were supplied sequentially in each phase. The organism, identified by fluorescence in situ hybridisation, was present throughout the granules; however, metabolic activity was limited to a 100-mum-thick layer immediately below the surface of the granules. To investigate the cause of this, oxygen microsensors and a novel microscale biosensor for volatile fatty acids were used in conjunction with chemical staining for intracellular storage polymers. It was found that the limited distribution of activity was caused by mass transport limitation of oxygen into the granules during the aerobic phase. (C) 2003 Federation of European Microbiological Societies. Published by Elsevier B.V. All rights reserved.
Resumo:
The development of a strong, active granular sludge bed is necessary for optimal operation of upflow anaerobic sludge blanket reactors. The microbial and mechanical structure of the granules may have a strong influence on desirable properties such as growth rate, settling velocity and shear strength. Theories have been proposed for granule microbial structure based on the relative kinetics of substrate degradation, but contradict some observations from both modelling and microscopic studies. In this paper, the structures of four granule types were examined from full-scale UASB reactors, treating wastewater from a cannery, a slaughterhouse, and two breweries. Microbial structure was determined using fluorescence in situ hybridisation probing with 16S rRNA-directed oligonucleotide probes, and superficial structure and microbial density (volume occupied by cells and microbial debris) assessed using scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The granules were also modelled using a distributed parameter biofilm model, with a previously published biochemical model structure, biofilm modelling approach, and model parameters. The model results reflected the trophic structures observed, indicating that the structures were possibly determined by kinetics. Of particular interest were results from simulations of the protein grown granules, which were predicted to have slow growth rates, low microbial density, and no trophic layers, the last two of which were reflected by microscopic observations. The primary cause of this structure, as assessed by modelling, was the particulate nature of the wastewater, and the slow rate of particulate hydrolysis, rather than the presence of proteins in the wastewater. Because solids hydrolysis was rate limiting, soluble substrate concentrations were very low (below Monod half saturation concentration), which caused low growth rates. (C) 2003 Elsevier Ltd. All rights reserved.