966 resultados para volumetric mass-transfer coefficient


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to estimate the first-order intrinsic kinetic constant (k(1)) and the liquid-phase mass transfer coefficient (k(c)) in a bench-scale anaerobic sequencing batch biofilm reactor (ASBBR) fed with glucose. A dynamic heterogeneous mathematical model, considering two phases (liquid and solid), was developed through mass balances in the liquid and solid phases. The model was adjusted to experimental data obtained from the ASBBR applied for the treatment of glucose-based synthetic wastewater with approximately 500 mg L-1 of glucose, operating in 8 h batch cycles, at 30 degrees C and 300 rpm. The values of the parameters obtained were 0.8911 min(-1) for k(1) and 0.7644 cm min(-1) for kc. The model was validated utilizing the estimated parameters with data obtained from the ASBBR operating in 3 h batch cycles, with a good representation of the experimental behavior. The solid-phase mass transfer flux was found to be the limiting step of the overall glucose conversion rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 2(3-1) factorial experimental design was used to evaluate the performance of a perforated rotating disc contactor to extract alpha-toxin from the fermented broth of Clostridium perfringens Type A by aqueous two-phase system of polyethylene glycol-phosphate salts. The influence of three independent variables, specifically the dispersed phase flowrate, the continuous phase flowrate and the disc rotational speed, was investigated on the hold up, the mass transfer coefficient, the separation efficiency and the purification factor, taken as the response variables. The optimum dispersed phase flowrate was 3.0 mL/min for all these responses. Besides, maximum values of hold up (0.80), separation efficiency (0. 10) and purification factor (2.4) were obtained at this flowrate using the lowest disc rotational speed (35 rpm), while the optimum mass transfer coefficient (0. 165 h(-1)) was achieved at the highest agitation level (140 rpm). The results of this study demonstrated that the dispersed phase flowrate strongly influenced the performance of PRDC, in that both the mass transfer coefficient and hold up increased with this parameter. (c) 2007 Elsevier B. V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation demonstrates the capability of a bench-scale sequencing batch reactor (SBR) to biodegrade an inhibitory substrate at a high loading rate. A SBR loading rate of 3.12 kg phenol.m(-3)d(-1) (2.1 g COD.g(-1) MLVSS d(-1)) with a COD removal efficiency of 97% at a SRT of 4 days and a HRT of 10 hours was achieved; this rate was not reached before. The SBR was operated at 4 hours cycle, including 3 hours react phase. The synthetic wastewater of 1300 mg/L phenol was the sole carbon source. Oxygen uptake rates (OUR) were monitored in-situ at various stages of the SBR. The oxygen mass transfer coefficient, K(L)a, of 12.6 h(-1) was derived from respirometry. Use of respirometry in SBR aided the tracking of the soluble substrate through OUR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work reports a relatively rapid procedure for the forecasting of the remediation time (RT) of sandy soils contaminated with cyclohexane using vapour extraction. The RT estimated through the mathematical fitting of experimental results was compared with that of real soils. The main objectives were: (i) to predict the RT of soils with natural organic matter (NOM) and water contents different from those used in experiments; and (ii) to analyse the time and efficiency of remediation, and the distribution of contaminants into the soil matrix after the remediation process, according to the soil contents of: (ii1) NOM; and (ii2) water. For sandy soils with negligible clay contents, artificially contaminated with cyclohexane before vapour extraction, it was concluded that: (i) if the NOM and water contents belonged to the range of the prepared soils, the RT of real soils could be predicted with relative differences not higher than 12%; (ii1) the increase of NOM content from 0% to 7.5% increased the RT (1.8–13 h) and decreased the remediation efficiency (RE) (99–90%) and (ii2) the increase of soil water content from 0% to 6% increased the RT (1.8–4.9 h) and decreased the RE (99–97%). NOM increases the monolayer capacity leading to a higher sorption into the solid phase. Increasing of soil water content reduces the mass transfer coefficient between phases. Concluding, NOM and water contents influence negatively the remediation process, turning it less efficient and more time consuming, and consequently more expensive.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for column design for any type of packing and contaminant which avoids the necessity of an arbitrary chosen diameter. It also avoids the employment of the usual graphical Eckert correlations for pressure drop. The hydraulic features are previously chosen as a project criterion. The design procedure was translated into a convenient algorithm in C++ language. A column was built in order to test the design, the theoretical steady-state and dynamic behaviour. The experiments were conducted using a solution of chloroform in distilled water. The results allowed for a correction in the theoretical global mass transfer coefficient previously estimated by the Onda correlations, which depend on several parameters that are not easy to control in experiments. For best describe the column behaviour in stationary and dynamic conditions, an original mathematical model was developed. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting ODE can be solved by analytical methods, and in dynamic state the discretization of the PDE by finite differences allows for the overcoming of this difficulty. To estimate the contaminant concentrations in both phases in the column, a numerical algorithm was used. The high number of resulting algebraic equations and the impossibility of generating a recursive procedure did not allow the construction of a generalized programme. But an iterative procedure developed in an electronic worksheet allowed for the simulation. The solution is stable only for similar discretizations values. If different values for time/space discretization parameters are used, the solution easily becomes unstable. The system dynamic behaviour was simulated for the common liquid phase perturbations: step, impulse, rectangular pulse and sinusoidal. The final results do not configure strange or non-predictable behaviours.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A potentially renewable and sustainable source of energy is the chemical energy associated with solvation of salts. Mixing of two aqueous streams with different saline concentrations is spontaneous and releases energy. The global theoretically obtainable power from salinity gradient energy due to World’s rivers discharge into the oceans has been estimated to be within the range of 1.4-2.6 TW. Reverse electrodialysis (RED) is one of the emerging, membrane-based, technologies for harvesting the salinity gradient energy. A common RED stack is composed by alternately-arranged cation- and anion-exchange membranes, stacked between two electrodes. The compartments between the membranes are alternately fed with concentrated (e.g., sea water) and dilute (e.g., river water) saline solutions. Migration of the respective counter-ions through the membranes leads to ionic current between the electrodes, where an appropriate redox pair converts the chemical salinity gradient energy into electrical energy. Given the importance of the need for new sources of energy for power generation, the present study aims at better understanding and solving current challenges, associated with the RED stack design, fluid dynamics, ionic mass transfer and long-term RED stack performance with natural saline solutions as feedwaters. Chronopotentiometry was used to determinate diffusion boundary layer (DBL) thickness from diffusion relaxation data and the flow entrance effects on mass transfer were found to avail a power generation increase in RED stacks. Increasing the linear flow velocity also leads to a decrease of DBL thickness but on the cost of a higher pressure drop. Pressure drop inside RED stacks was successfully simulated by the developed mathematical model, in which contribution of several pressure drops, that until now have not been considered, was included. The effect of each pressure drop on the RED stack performance was identified and rationalized and guidelines for planning and/or optimization of RED stacks were derived. The design of new profiled membranes, with a chevron corrugation structure, was proposed using computational fluid dynamics (CFD) modeling. The performance of the suggested corrugation geometry was compared with the already existing ones, as well as with the use of conductive and non-conductive spacers. According to the estimations, use of chevron structures grants the highest net power density values, at the best compromise between the mass transfer coefficient and the pressure drop values. Finally, long-term experiments with natural waters were performed, during which fouling was experienced. For the first time, 2D fluorescence spectroscopy was used to monitor RED stack performance, with a dedicated focus on following fouling on ion-exchange membrane surfaces. To extract relevant information from fluorescence spectra, parallel factor analysis (PARAFAC) was performed. Moreover, the information obtained was then used to predict net power density, stack electric resistance and pressure drop by multivariate statistical models based on projection to latent structures (PLS) modeling. The use in such models of 2D fluorescence data, containing hidden, but extractable by PARAFAC, information about fouling on membrane surfaces, considerably improved the models fitting to the experimental data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examined the effects of riparian vegetation removal on algal dynamics and stream nutrient retention efficiency by comparing NH4-N and PO4-P uptake lengths from a logged and an unlogged reach in Riera Major, a forested Mediterranean stream in northeastern Spain. From June to September 1995, we executed 6 short-term additions of N (as NH4Cl) and P (as Na2HPO4) in a 200-m section to measure nutrient uptake lengths. The study site included 2 clearly differentiated reaches in terms of canopy cover by riparian trees: the first 100 m were completely logged (i.e., the logged reach) and the remaining 100 m were left intact (i.e., the shaded reach). Trees were removed from the banks of the logged reach in the winter previous to our sampling. In the shaded reach, riparian vegetation was dominated by alders (Alnus glutinosa). The study was conducted during summer and fall months when differences in light availability between the 2 reaches were greatest because of forest canopy conditions. Algal biomass and % of stream surface covered by algae were higher in the logged than in the shaded reach, indicating that logging had a stimulatory effect on algae in the stream. Overall, nutrient retention efficiency was higher (i.e., shorter uptake lengths) in the logged than in the shaded reach, especially for PO4-P. Despite a greater increase in PO4-P retention efficiency relative to that of NH4-N following logging, retention efficiency for NH4-N was higher than for PO4-P in both study reaches. The PO4-P mass-transfer coefficient was correlated with primary production in both study reaches, indicating that algal activity plays an important role in controlling PO4-P dynamics in this stream. In contrast, the NH4-N mass-transfer coefficient showed a positive relation-ship only with % of algal coverage in the logged reach, and was not correlated with any algal-related parameter in the shaded reach. The lack of correlation with algal production suggests that mechanisms other than algal activity (i.e., microbial heterotrophic processes or abiotic mechanisms) may also influence NH4-N retention in this stream. Overall, this study shows that logging disturbances in small shaded streams may alter in-stream ecological features that lead to changes in stream nutrient retention efficiency. Moreover, it emphasizes that alteration of the tight linkage between the stream channel and the adjacent riparian zone may directly and indirectly impact biogeochemical processes with implications for stream ecosystem functioning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työssä tutkittiin, mikä on kustannustehokkain tapa lisätä ilmastuskapasiteettia ja selvitettiin, saostaako vesilaitokselta flotaatioaltaasta poistettava ferrisulfaattisakka jäteveden fosforia esiselkeyttimessä. Työssä määritettiin teoreettinen hapentarve ilmastusaltaassa maksimikuormituksen aikana ja hapensiirtonopeus jäteveteen olemassa olevalla laitteistolla. Hapensiirtonopeuden funktion korjauskertoimet  ja  sekä kokonaishapensiirtokerroin määritettiin laboratorio-olosuhteissa. Lisäksi laskettiin kuinka paljon nykyisten ilmastimien kautta saadaan happea jäteveteen liukenemaan ja verrattiin tätä lukua teoreettiseen hapentarpeeseen. Jälkimmäistä menettelytapaa käyttäen arvioitiin lisähapen tarve. Tulokseksi saatiin, että maksimi BOD-kuormituksen aikana happea tarvitsee saada jäteveteen liuotettua 5200 m³/d lisää. Ilmastuskapasiteetin lisäyksen kustannuslaskelmassa verrattiin neljää vaihtoehtoa: puhdasta happea liuotettuna happimattojen kautta tai OKI-ilmastimen kautta, onsite-happilaitoksen puhdasta happea liuotettuna OKI-ilmastimen kautta tai ilman happea liuotettuna jäteveteen EDI-ilmastimien kautta. Laskelmat osoittivat uusien EDI-ilmastimien hankinnan olevan edullisin vaihtoehto pitkällä aikavälillä. Vaikka EDI-ilmastimien investointikustannukset ovat korkeat, tulevat ne käyttökustannuksiltaan kaikkein edullisimmaksi. Vesilaitokselta tulevan rautasuolasakan fosforia saostavaa vaikutusta tutkittiin laboratoriossa astiakokein. Näytteet otettiin vesilaitokselta jätevesilaitokselle menevästä rautasuolasakasta sekä esiselkeyttimen kirkasteesta. Näitä eri suhteissa keskenään sekoittamalla saatiin selville, että rautasuolasakka ja sakan mukana tuleva reagoimaton rautasuola saostavat liukoista ja kokonaisfosforia esiselkeytyksessä.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microreactors have proven to be versatile tools for process intensification. Over recent decades, they have increasingly been used for product and process development in chemical industries. Enhanced heat and mass transfer in the reactors due to the extremely high surfacearea- to-volume ratio and interfacial area allow chemical processes to be operated at extreme conditions. Safety is improved by the small holdup volume of the reactors and effective control of pressure and temperature. Hydrogen peroxide is a powerful green oxidant that is used in a wide range of industries. Reduction and auto-oxidation of anthraquinones is currently the main process for hydrogen peroxide production. Direct synthesis is a green alternative and has potential for on-site production. However, there are two limitations: safety concerns because of the explosive gas mixture produced and low selectivity of the process. The aim of this thesis was to develop a process for direct synthesis of hydrogen peroxide utilizing microreactor technology. Experimental and numerical approaches were applied for development of the microreactor. Development of a novel microreactor was commenced by studying the hydrodynamics and mass transfer in prototype microreactor plates. The prototypes were designed and fabricated with the assistance of CFD modeling to optimize the shape and size of the microstructure. Empirical correlations for the mass transfer coefficient were derived. The pressure drop in micro T-mixers was investigated experimentally and numerically. Correlations describing the friction factor for different flow regimes were developed and predicted values were in good agreement with experimental results. Experimental studies were conducted to develop a highly active and selective catalyst with a proper form for the microreactor. Pd catalysts supported on activated carbon cloths were prepared by different treatments during the catalyst preparation. A variety of characterization methods were used for catalyst investigation. The surface chemistry of the support and the oxidation state of the metallic phase in the catalyst play important roles in catalyst activity and selectivity for the direct synthesis. The direct synthesis of hydrogen peroxide was investigated in a bench-scale continuous process using the novel microreactor developed. The microreactor was fabricated based on the hydrodynamic and mass transfer studies and provided a high interfacial area and high mass transfer coefficient. The catalysts were prepared under optimum treatment conditions. The direct synthesis was conducted at various conditions. The thesis represents a step towards a commercially viable direct synthesis. The focus is on the two main challenges: mitigating the safety problem by utilization of microprocess technology and improving the selectivity by catalyst development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study combines several projects related to the flows in vessels with complex shapes representing different chemical apparata. Three major cases were studied. The first one is a two-phase plate reactor with a complex structure of intersecting micro channels engraved on one plate which is covered by another plain plate. The second case is a tubular microreactor, consisting of two subcases. The first subcase is a multi-channel two-component commercial micromixer (slit interdigital) used to mix two liquid reagents before they enter the reactor. The second subcase is a micro-tube, where the distribution of the heat generated by the reaction was studied. The third case is a conventionally packed column. However, flow, reactions or mass transfer were not modeled. Instead, the research focused on how to describe mathematically the realistic geometry of the column packing, which is rather random and can not be created using conventional computeraided design or engineering (CAD/CAE) methods. Several modeling approaches were used to describe the performance of the processes in the considered vessels. Computational fluid dynamics (CFD) was used to describe the details of the flow in the plate microreactor and micromixer. A space-averaged mass transfer model based on Fick’s law was used to describe the exchange of the species through the gas-liquid interface in the microreactor. This model utilized data, namely the values of the interfacial area, obtained by the corresponding CFD model. A common heat transfer model was used to find the heat distribution in the micro-tube. To generate the column packing, an additional multibody dynamic model was implemented. Auxiliary simulation was carried out to determine the position and orientation of every packing element in the column. This data was then exported into a CAD system to generate desirable geometry, which could further be used for CFD simulations. The results demonstrated that the CFD model of the microreactor could predict the flow pattern well enough and agreed with experiments. The mass transfer model allowed to estimate the mass transfer coefficient. Modeling for the second case showed that the flow in the micromixer and the heat transfer in the tube could be excluded from the larger model which describes the chemical kinetics in the reactor. Results of the third case demonstrated that the auxiliary simulation could successfully generate complex random packing not only for the column but also for other similar cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dins dels processos de recuperació de metalls de dissolucions diluïdes s'ha realitzat un estudi del procés d'extracció d'or i de zinc mitjançant resines amberlite XAD-2 impregnades amb sulfur de triisobutil fosfina (TIBPS) i àcid di-(2-etilhexil) fosfòric (DEHPA) respectivament. S'ha realitzat un estudi de l'equilibri de l'adsorció d'espècies metàl·liques d'aquests metalls amb les resines indicades anteriorment. Amb la metodologia emprada per a la determinació dels punts d'equilibri dels experiments en batch i en columna, s'ha vist que una única isoterma no podia descriure el fenomen global d'equilibri i que en funció de la metodologia emprada s'obtenien isotermes diferents. Es va introduir una nova variable per poder explicar el fenomen observat, i per tant, amb aquesta nova variable l'equació de la isoterma es converteix amb l'equació d'una supèrfície que s'ha definit com a Superfície d'Equilibri. S'han determinat les equacions de les Suprfícies d'Equilibri dels sistemes d'adsorció estudiats (Au(III) TIBPS/XAD-2 i Zn(II) DEHPA/XAD-2) observan una bona coincidència de tots els punts d'equilibri obtinguts sobre la superfície, així com, un bon ajust de totes les isotermes obtingudes en funció de les diferents metodologies emprades sobre les respectives superfícies d'equilibri. Aquest nou concepte generalitza el concepte d'isoterma d'un procés d'adsorció. Fimalment, s'ha plantejat un model matemàtic d'adsorció per a determinar el coeficient efectiu de difusió (De) i el coeficient de transferància de matèria (kf) per ambdós sistemes d'adsorció estudiats mitjançant l'aplicació del model de difusió de sòlid homogeni (HSDM), utilitzant com a condició de contorn en el model la isoterma de Langmuir obtinguda mitjançant els experiments en columna de llit fix i emprant també l'equació obtinguda mitjançant el nou concepte de Superfície d'Equilibri. Els resultats obtinguts són molt satisfactoris, per tant, es pot concloure que la Superfície d'Equilibri és una bona eina per a descriure l'equilibri en els processos d'adsorció d'or i zinc amb les resines amberlite XAD-2 impregnades amb TIBPS i DEHPA respectivament.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports experiments involving the electrochemical combustion of humic acid (HA) and removal of algae from pond water. An electrochemical flow reactor with a boron-doped diamond film anode was used and constant current experiments were conducted in batch recirculation mode. The mass transfer characteristics of the electrochemical device were determined by voltammetric experiments in the potential region of water stability, followed by a controlled current experiment in the potential region of oxygen evolution. The average mass transfer coefficient was 5.2 x 10(-5) m s(-1). The pond water was then processed to remove HA and algae in the conditions in which the reaction combustion occurred under mass transfer control. To this end, the mass transfer coefficient was used to estimate the initial limiting current density applied in the electrolytic experiments. As expected, all the parameters analyzed here-solution absorbance at 270 nm, total phenol concentration and total organic carbon concentration-decayed according to first-order kinetics. Since the diamond film anode successfully incinerated organic matter, the electrochemical system proved to be predictable and programmable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study were projected, built and tested an electric solar dryer consisting of a solar collector, a drying chamber, an exhaust fan and a fan to promote forced hot air convection. Banana drying experiments were also carried out in a static column dryer to model the drying and to obtain parameters that can be used as a first approximation in the modeling of an electric solar dryer, depending on the similarity of the experimental conditions between the two drying systems. From the banana drying experiments conducted in the static column dryer, we obtained food weight data as a function of aqueous concentration and temperature. Simplified mathematical models of the banana drying were made, based on Fick s and Fourier s second equations, which were tested with the experimental data. We determined and/or modeled parameters such as banana moisture content, density, thin layer drying curves, equilibrium moisture content, molecular diffusivity of the water in banana DAB, external mass transfer coefficient kM, specific heat Cp, thermal conductivity k, latent heat of water evaporation in the food Lfood, time to heat food, and minimum energy and power required to heat the food and evaporate the water. When we considered the shrinkage of radius R of a banana, the calculated values of DAB and kM generally better represent the phenomenon of water diffusion in a solid. The latent heat of water evaporation in the food Lfood calculated by modeling is higher than the latent heat of pure water evaporation Lwater. The values calculated for DAB and KM that best represent the drying were obtained with the analytical model of the present paper. These values had good agreement with those assessed with a numeric model described in the literature, in which convective boundary condition and food shrinkage are considered. Using parameters such as Cp, DAB, k, kM and Lfood, one can elaborate the preliminary dryer project and calculate the economy using only solar energy rather than using solar energy along with electrical energy

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mössbauer Spektroskopie ist ein unverzichtbares Instrument für die Bestimmung von Oxidationszuständen und für die Analyse von lokalen Ordnungsphänomenen von Mössbauer aktiven Atomen. Weil es sich um eine lokale Methode handelt können sowohl kristalline als auch amorphe Materialien untersucht werden. Die Kombination von lokaler Prüfung mit Mössbauer Spektroskopie und globaler Untersuchung z.B. mit Röntgendiffraktometrie ermöglicht die Studie von Ordnungseffekten von statistisch besetzten Positionen in einer geordneten Matrix. Das wurde hier eingesetzt um die lokale Umgebung in zwei Serien von Heuslerverbindungen, Co2-xFe1+xSi and Co2Mn1-xFexAl zu untersuchen. Für die Co2Mn1-xFexAl Serie wurde eine L21 geordnete Phase in einer insgesamt B2 geordneten Probe detektiert. Ein Wechsel von der AlCu2Mn zu der CuHg2Ti Struktur wurde für die Co2-xFe1+xSi Proben gefunden. Die Transformation von einem Glas zu einem keramischen Material wurde mit 119Sn Mössbauer Spektroskopie untersucht. Die höhere Ordnung in der Keramik wurde von einer kleiner werdenden Mössbauerlinienbreite begleitet. Demzufolge geben die Modifikationen der Sn Umgebungen klar die Transformation des gesamten Materials wieder. Ist die lokale Umgebung von unregelmäßig auftretenden Atomen in einer amorphen Matrix von Interesse, sind lokal prüfende Methoden die zuverlässigsten Methoden die zur Verfügung stehen. In dieser Arbeit wurde 119Sn Mössbauer Spektroskopie eingesetzt um die Oxidationszustände, die lokalen Umgebungen und relativen Intensitäten von Zinn Atomen in einer Silikatmatrix zu bestimmen. Modifikationen dieser Parameter als Funktion von Prozess bestimmenden Parametern wie der Sauerstoffpartialdruck, die Temperatur, die Behandlungsdauer und der Abkühlprozess genauso wie der SnO2 Gehalt sind von Interesse, weil durch Reduktions- und Diffusionsprozesse Änderungen des Koordinations- und des Oxidationszustands der Zinnatome auftreten. Da diese Änderungen in der Glasmatrix verursachen, die das fertige Produkt im industriellen Fertigungsprozess ruinieren können sind diese feinen Veränderungen sehr wichtig. Wenigstens zwei Mössbauerlinien korrespondierend mit zwei verschiedenen Umgebungen für Sn2+ und Sn4+ sind für eine Analyse mit ausreichender Qualität notwendig. Durch Vergleich von den bestimmten Hyperfein Parametern mit den Parametern von Modelsubstanzen werden lokale Umgebungen der Zinnatome entworfen. Für Sn2+ werden zwei auf einer trigonalen Pyramide basierende Umgebungen mit variierender Anzahl von bindenden und nicht-bindenden Sauerstoffatomen formuliert. Für Sn4+ wurde eine tetraedrische und eine oktaedrische Umgebung postuliert. Die relativen Intensitäten der vier Mössbauerlinien wurden um ein Diffusions- und Reaktionsmodell zu entwickeln und um einen Satz von Diffusions- und Transferkoeffizienten zu bestimmen eingesetzt. Die bestimmten Diffusionskoeffizienten stimmen mit den Literaturdaten überein. Der Massentransferkoeffizient ist kleiner als der bestimmte Wert, aber immer noch in der gleichen Größenordnung. Im Gegensatz zu den Erwartungen ist der präsentierte Diffusionskoeffizient für Sn4+ bestimmt als der von Sn2+. Das wiederum kann durch Berücksichtigung von Elektronhoppingprozessen erklärt werden.