925 resultados para visual sensitivity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine whether teletherapy with 6-mV photons can reduce visual loss in patients with subfoveal choroidal neovascularization in age-related macular degeneration. Design: A multicenter, single-masked, randomized controlled trial of 12 Gy of external beam radiation therapy delivered to the macula of an affected eye vs observation only. Setting: Three United Kingdom-based hospital units. Participants: Patients with age-related macular degeneration, aged 60 years and older, who had subfoveal choroidal neovascularization and a visual acuity of 20/200 (logMAR 1.0) or better. Methods: Two hundred three patients were randomly assigned to radiotherapy or observation. Treatment was undertaken at designated radiotherapy centers, and patients assigned to the treatment group received a total dosage of 12 Gy of 6-mV photons in 6 fractions. Follow-up was scheduled at 3, 6, 12, and 24 months. After excluding protocol violators, the data from 199 patients were analyzed. Main Outcome Measures: The primary outcome measure was mean loss of distance visual acuity in the study eye at 12 and 24 months. Other outcome variables analyzed were near visual acuity and contrast sensitivity. The proportions of patients losing 3 or more or 6 or more lines of distance and near acuity and 0.3 or more or 0.6 or more log units of contrast sensitivity at each follow-up were also analyzed. Results: At all time points, mean distance visual acuity was better in the radiotherapy-treated group than in the control group, but the differences did not reach statistical significance. At 24 months, analysis of the proportions of patients with loss of 3 or more (moderate) (P=.08) or 6 or more (severe) (P=.29) lines of distance vision showed that fewer treated patients had severe losses, but there was no statistically significant difference between groups. For near visual acuity, although there was no evidence of treatment benefit at 12 and 24 months, a significant difference in favor of treatment was present at 6 months (P=.048). When analyzed by the proportions of patients losing 3 lines of contrast sensitivity, there was a significant difference in favor of treatment at 24 months (P=.02). No adverse retinal effects were observed during the study, but transient disturbance of the precorneal tear film was noted in treated patients. Conclusion: The results of the present trial do not support the routine clinical use of external beam radiation therapy in subjects with subfoveal choroidal neovascularization in age-related macular degeneration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To compare the ability of Glaucoma Progression Analysis (GPA) and Threshold Noiseless Trend (TNT) programs to detect visual-field deterioration.

METHODS: Patients with open-angle glaucoma followed for a minimum of 2 years and a minimum of seven reliable visual fields were included. Progression was assessed subjectively by four masked glaucoma experts, and compared with GPA and TNT results. Each case was judged to be stable, deteriorated or suspicious of deterioration

RESULTS: A total of 56 eyes of 42 patients were followed with a mean of 7.8 (SD 1.0) tests over an average of 5.5 (1.04) years. Interobserver agreement to detect progression was good (mean kappa = 0.57). Progression was detected in 10-19 eyes by the experts, in six by GPA and in 24 by TNT. Using the consensus expert opinion as the gold standard (four clinicians detected progression), the GPA sensitivity and specificity were 75% and 83%, respectively, while the TNT sensitivity and specificity was 100% and 77%, respectively.

CONCLUSION: TNT showed greater concordance with the experts than GPA in the detection of visual-field deterioration. GPA showed a high specificity but lower sensitivity, mainly detecting cases of high focality and pronounced mean defect slopes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the changes in the Visual Field Index (VFI) in eyes with perimetric glaucomatous progression, and to compare these against stable glaucoma patients.

PATIENTS AND METHODS: Consecutive patients with open angle glaucoma with a minimum of 6 reliable visual fields and 2 years of follow-up were identified. Perimetric progression was assessed by 4 masked glaucoma experts from different units, and classified into 3 categories: "definite progression," "suspected progression," or "no progression." This was compared with the Glaucoma Progression Analysis (GPA) II and VFI linear regression analysis, where progression was defined as a negative slope with significance of <5%.

RESULTS: Three hundred ninety-seven visual fields from 51 eyes of 39 patients were assessed. The mean number of visual fields was 7.8 (SD 1.1) per eye, and the mean follow-up duration was 63.7 (SD 13.4) months. The mean VFI linear regression slope showed an overall statistically significant difference (P<0.001, analysis of variance) for each category of progression. Using expert consensus opinion as the reference standard, both VFI analysis and GPA II had high specificity (0.93 and 0.90, respectively), but relatively low sensitivity (0.45 and 0.41, respectively).

CONCLUSIONS: The mean VFI regression slope in our cohort of eyes without perimetric progression showed a statistically significant difference compared with those with suspected and definite progression. VFI analysis and GPA II both had similarly high specificity but low sensitivity when compared with expert consensus opinion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare two fast threshold strategies of visual field assessment; SITA Fast (HSF) and Tendency Orientated Perimetry (TOP), in detecting visual field loss in patients with glaucoma. Methods: Seventy-six glaucoma, ocular hypertensive and normal patients had HSF and TOP performed in random order. Quantitative comparisons for the global visual field indices - mean deviation and defect (MD) for HSF and TOP, and pattern standard deviation (PSD) for HSF and loss variance (LV) for TOP - were made using correlation coefficients. Humphrey global parameters were converted to Octopus equivalents, and method comparison analysis was used to determine agreement between the two strategies. Test duration times were compared using t-test. Sensitivity and specificity for these two algorithms were determined according to predetermined criteria. Results: High correlation coefficient values were obtained for MD measurements between HSF and TOP (r=-0.89, P

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deficits in sensitivity to visual stimuli of low spatial frequency and high temporal frequency (so-called frequency-doubled gratings) have been demonstrated both in schizophrenia and in autism spectrum disorder (ASD). Such basic perceptual functions are ideal candidates for molecular genetic study, because the underlying neural mechanisms are well characterized; but they have sometimes been overlooked in favor of cognitive and neurophysiological endophenotypes, for which neural substrates are often unknown. Here, we report a genome-wide association study of a basic visual endophenotype associated with psychological disorder. Sensitivity to frequency-doubled gratings was measured in 1060 healthy young adults, and analyzed for association with genotype using linear regression at 642758 single nucleotide polymorphism (SNP) markers. A significant association (P=7.9×10) was found with the SNP marker rs1797052, situated in the 5′-untranslated region of PDZK1; each additional copy of the minor allele was associated with an increase in sensitivity equivalent to more than half a standard deviation. A permutation procedure, which accounts for multiple testing, showed that the association was significant at the α=0.005 level. The region on chromosome 1q21.1 surrounding PDZK1 is an established susceptibility locus both for schizophrenia and for ASD, mirroring the common association of the visual endophenotype with the two disorders. PDZK1 interacts with N-methyl-d-aspartate receptors and neuroligins, which have been implicated in the etiologies of schizophrenia and ASD. These findings suggest that perceptual abnormalities observed in two different disorders may be linked by common genetic elements. © 2013 John Wiley & Sons Ltd and International Behavioural and Neural Genetics Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A prototype scotopic sensitivity machine was used to evaluate pupillary and visual thresholds for 295 Indonesian children aged 1-5 y, most of whom were initially vitamin A-deficient. Subjects were tested 6 and 9 mo after receiving a high dose of vitamin A. A group of 136 older children was tested at 6 mo after dosing; all subjects underwent testing at 9 mo. After testing at 9 mo, children randomly received either a second high dose of vitamin A or placebo and were tested a final time 2 wk later. Children with abnormal pupillary thresholds had significantly higher relative dose responses (RDRs) (P < 0.01) and significantly lower serum retinol values (P = 0.05) than did normal children. The mean pupillary threshold rose (eg, retinal sensitivity fell) as vitamin A status deteriorated between 6 and 9 mo after initial dosing, and was significantly different from a group of normal American children tested previously (P < 0.001). After placebo-controlled dosing, the decline in pupillary and visual thresholds (rise in retinal sensitivity) was significant for children receiving vitamin A but not for children receiving placebo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mouse has emerged as an animal model for many diseases. At IRO, we have used this animal to understand the development of many eye diseases and treatment of some of them. Precise evaluation of vision is a prerequisite for both these approaches. In this unit we describe three ways to measure vision: testing the optokinetic response, and evaluating the fundus by direct observation and by fluorescent angiography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the contrast visual processing of concentric sinusoidal gratings stimuli between adolescents and adults. The study included 20 volunteers divided into two groups: 10 adolescents aged 13-19 years (M=16.5, SD=1.65) and 10 adults aged 20-26 years (M=21.8, SD=2.04). In order to measure the contrast sensitivity at spatial frequencies of 0.6, 2.5, 5 and 20 degrees of visual angle (cpd), it was used the psychophysical method of two alternative forced choice (2AFC). A One Way ANOVA performance showed a significant difference in the comparison between groups: F [(4, 237)=3.74, p<.05]. The post-hoc Tukey HSD showed a significant difference between the frequencies of 0.6 (p <.05) and 20 cpd (p<.05). Thus, the results showed that the visual perception behaves differently with regard to the sensory mechanisms that render the contrast towards adolescents and adults. These results are useful to better characterize and comprehend human vision development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent theories propose that semantic representation and sensorimotor processing have a common substrate via simulation. We tested the prediction that comprehension interacts with perception, using a standard psychophysics methodology.While passively listening to verbs that referred to upward or downward motion, and to control verbs that did not refer to motion, 20 subjects performed a motion-detection task, indicating whether or not they saw motion in visual stimuli containing threshold levels of coherent vertical motion. A signal detection analysis revealed that when verbs were directionally incongruent with the motion signal, perceptual sensitivity was impaired. Word comprehension also affected decision criteria and reaction times, but in different ways. The results are discussed with reference to existing explanations of embodied processing and the potential of psychophysical methods for assessing interactions between language and perception.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous climate model simulations have shown that the configuration of the Earth's orbit during the early to mid-Holocene (approximately 10–5 kyr) can account for the generally warmer-than-present conditions experienced by the high latitudes of the northern hemisphere. New simulations for 6 kyr with two atmospheric/mixed-layer ocean models (Community Climate Model, version 1, CCMl, and Global ENvironmental and Ecological Simulation of Interactive Systems, version 2, GENESIS 2) are presented here and compared with results from two previous simulations with GENESIS 1 that were obtained with and without the albedo feedback due to climate-induced poleward expansion of the boreal forest. The climate model results are summarized in the form of potential vegetation maps obtained with the global BIOME model, which facilitates visual comparisons both among models and with pollen and plant macrofossil data recording shifts of the forest-tundra boundary. A preliminary synthesis shows that the forest limit was shifted 100–200 km north in most sectors. Both CCMl and GENESIS 2 produced a shift of this magnitude. GENESIS 1 however produced too small a shift, except when the boreal forest albedo feedback was included. The feedback in this case was estimated to have amplified forest expansion by approximately 50%. The forest limit changes also show meridional patterns (greatest expansion in central Siberia and little or none in Alaska and Labrador) which have yet to be reproduced by models. Further progress in understanding of the processes involved in the response of climate and vegetation to orbital forcing will require both the deployment of coupled atmosphere-biosphere-ocean models and the development of more comprehensive observational data sets

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of visual stimuli intensity on manual reaction time (RT) was investigated under two different attentional settings: high (Experiment 1) and low (Experiment 2) stimulus location predictability. These two experiments were also run under both binocular and monocular viewing conditions. We observed that RT decreased as stimulus intensity increased. It also decreased as the viewing condition was changed from monocular to binocular as well as the location predictability shifted from low to high. A significant interaction was found between stimulus intensity and viewing condition, but no interaction was observed between neither of these factors and location predictability. These findings support the idea that the stimulus intensity effect arises from purely sensory, pre-attentive mechanisms rather than deriving from more efficient attentional capture. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The spectral absorption characteristics of the retinal photoreceptors of the blue tit (Pal trs caeruleus) and blackbird (Turdus merula) were investigated using microspectrophotometry. The retinae of both species contained rods, double cones and four spectrally distinct types of single cone. Whilst the visual pigments and cone oil droplets in the other receptor types are very similar in both species, the wavelength of maximum sensitivity (lambda(max)) of long-wavelength-sensitive single and double cone visual pigment occurs at a shorter wavelength (557 nm) in the blackbird than in the blue tit (563 nm). Oil droplets located in the long-wavelength-sensitive-single cones of both species cut off wavelengths below 570-573 nm, theoretically shifting cone peak spectral sensitivity some 40 nm towards the long-wavelength end of the spectrum. This raises the possibility that the precise lambda(max) of the long-wavelength-sensitive visual pigment is optimised for the visual function of the double cones. The distribution of cone photoreceptors across the retina, determined using conventional light and fluorescence microscopy also varies between the two species and may reflect differences in their visual ecology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Effective visual communication requires signals that are easy to detect, transmit, receive, and discriminate. Animals can increase the probability that their visual signals would be detected by evolving signals that contrast with their visual background. Animals can further enhance this contrast by behaviorally modifying the existing visual background. Male golden-collared manakins (Manacus vitellinus) clear leaf litter from the ground to form courts, which are used as display arenas. Using reflectance measures of the signal (male plumage) and the visual background (cleared court and adjacent litter), the irradiance measures of ambient light during display, and published measures of photoreceptor sensitivity of a Passerine, we test the hypothesis that court-clearing augments the contrast between male plumage and the visual background. We find that the chromatic and brightness contrasts of golden patches used during courtship are greater against the cleared court than against adjacent litter. In addition, we find that cleared courts provide a less variable background for these color patches, resulting in displays that consistently contrast the visual background. These results suggest that behavioral modification of the visual background may act to increase the conspicuousness of colorful male plumage during display, providing an explanation for why golden-collared manakins, and possibly other species, build or clear display courts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To compare frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) for detecting glaucomatous visual field progression in a longitudinal prospective study.

METHODS. One eye of patients with open-angle glaucoma was tested every 6 months with both FDT and SAP. A minimum of 6 examinations with each perimetric technique was required for inclusion. Visual field progression was determined by two methods: glaucoma change probability (GCP) analysis and linear regression analysis (LRA). For GCP, several criteria for progression were used. The number of locations required to classify progression with FDT compared with SAP, respectively, was 1:2 (least conservative), 1:3, 2:3, 2:4, 2:6, 2:7, 3:6, 3:7, and 3:10 (most conservative). The number of consecutive examinations required to confirm progression was 2-of-3, 2-of-2, and 3-of-3. For LRA, the progression criterion was any significant decline in mean threshold sensitivity over time in each of the following three visual field subdivisions: (1) all test locations, (2) locations in the central 10° and the superior and inferior hemifields, and (3) locations in each quadrant. Using these criteria, the proportion of patients classified as showing progression with each perimetric technique was calculated and, in the case of progression with both, the differences in time to progression were determined.

RESULTS. Sixty-five patients were followed for a median of 3.5 years (median number of examinations, 9). For the least conservative GCP criterion, 32 (49%) patients were found to have progressing visual fields with FDT and 32 (49%) patients with SAP. Only 16 (25%) patients showed progression with both methods, and in most of those patients, FDT identified progression before SAP (median, 12 months earlier). The majority of GCP progression criteria (15/27), classified more patients as showing progression with FDT than with SAP. Contrary to this, more patients showed progression with SAP than FDT, when analysed with LRA; e.g., using quadrant LRA 20 (31%) patients showed progression with FDT, 23 (35%) with SAP, and only 10 (15%) with both.

CONCLUSIONS. FDT perimetry detected glaucomatous visual field progression. However, the proportion of patients who showed progression with both FDT and SAP was small, possibly indicating that the two techniques identify different subgroups of patients. Using GCP, more patients showed progression with FDT than with SAP, yet the opposite occurred using LRA. As there is no independent qualifier of progression, FDT and SAP progression rates vary depending on the method of analysis and the criterion used.