875 resultados para vacuum aspiratory technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of the nipple-areola complex (NAC) is the last stage of breast reconstruction and represents the search for symmetry in regard to the contralateral breast. The objective of this study was to present an areola reconstruction technique with local skin graft to improve the texture and aspect of the reconstructed areola, searching for a natural look. This technique was performed on 122 patients who in the period from January 2000 to December 2005 were submitted to nipple and areola reconstruction. Once the position of the new nipple was determined, markings were made for the reconstruction of the areola. Then the external limit of the new areola was incised and the skin was centripetally deepidermized up to 85% of its diameter. After this procedure the detached skin was repositioned in its bed as a graft and sutured with 4.0 mononylon thread. Incisions with an 11-blade scalpel were then made in V and C forms associated with the detachment of this skin of the receptor area along the local graft so that at the end of the healing process they would determine alterations in the areolar texture mimicking the texture of a normal areola. All patients underwent tattooing 3 months after reconstruction of the NAC taking into account the different shades of the contralateral areola and nipple colors. The use of a local skin graft associated with C and V incisions allowed alteration in the texture of the reconstructed areola. The use of different ink shades for tattooing helped to give a tridimensional aspect to this areola. These factors determined a good aesthetic result in these patients. This areola reconstruction using a local skin graft allows change in the areola texture and a tridimensional aspect similar to that of a normal areola without the inconvenience of grafting from a distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirty-one patients with unilateral long-standing facial palsy underwent I-stage reanimation with free gracilis muscle transplant innervated by the masseteric branch of the trigeminal nerve. They were divided into 2 nonrandomized groups according to insertion technique: group 1 (9 patients), interrupted suture between the free flap and the orbicularis oris of the upper and lower lip on the paralyzed side; group It (22 patients), palmaris longus tendon graft placed between the gracilis free flap and the orbicularis oris of the upper and lower lip on the nonparalyzed side. Qualitative evaluation of the smile demonstrated better results in patients from group II. Comparing the position Of the Cupid`s bow at rest, pre- and postoperatively in each patient, we observed significant improvement of facial symmetry in both groups. During smile, however, there was a significantly higher rate of centralization of the Cupid`s bow in patients submitted to reanimation with the use of the palmaris longus tendon (group II).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The steady-state resonance fluorescence spectrum of a two-level atom driven by a bichromatic field in a broadband squeezed vacuum is studied. When the carrier frequency of the squeezed vacuum is tuned to the frequency of the central spectral line, anomalous spectral features, such as hole burning and dispersive profiles, can occur at the central line. We show that these features appear for wider, and experimentally more convenient, ranges of the parameters than in the case of monochromatic excitation. ?he absence of a coherent spectral component at the central line makes any experimental attempt to observe these features much easier. We also discuss the general features of the spectrum. When the carrier frequency of the squeezed vacuum is tuned to the first odd or even sidebands, the spectrum is asymmetric and only the sidebands an sensitive to phase. For appropriate choices of the phase the linewidths or only the odd or even sidebands can be reduced. A dressed-stale interpretation is provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fluorescence spectrum of a strongly driven two-level atom located inside an optical cavity damped by a narrow-bandwidth squeezed vacuum is studied. We use a dressed atom model approach, first applied to squeezed vacuum problems by Yeoman and Barnett, to derive the master equation of the system and discuss the role of the cavity and the squeezed vacuum in the narrowing of the spectral lines and the population trapping effect. We find that in the presence of a single-mode cavity the effect of squeezing on the fluorescence spectrum is more evident in the linewidths of the Rabi sidebands rather than in the linewidth of the central component. Even in the absence of squeezing, the cavity can reduce the linewidth of the central component almost to zero, whereas the Rabi sidebands can be narrowed only to some finite value. In the presence of a two-mode cavity and a two-mode squeezed vacuum the signature of squeezing is evident in the linewidths of all spectral lines. We also establish that the narrowing of the spectral lines is very sensitive to the detuning of the driving field from the atomic resonance. Moreover, we find that the population trapping effect, predicted for the broadband squeezed vacuum case, may appear in a narrow-bandwidth case only if the input squeezed modes are perfectly matched to the cavity modes and if there is non-zero squeezing at the Rabi sidebands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Advantages of the bicaval versus the biatrial technique have been reported, emphasizing atrial electrical stability and less tricuspid regurgitation. Objective. To analyze the impact of the surgical technique on long-term pulmonary pressures, contractility, and graft valvular behavior after heart transplantation. Methods. Among 400 orthotopic heart transplantation recipients from 1985 to 2010, we selected 30 consecutive patients who had survived beyond 3 years. The biatrial versus bicaval surgical technique groups included 15 patients each. Their preoperative clinical characteristics were similar. None of the patients displayed a pulmonary vascular resistance or pulmonary artery pressure over 6U Wood or 60 mm Hg, respectively. We evaluated invasive hemodynamic parameters during routine endomyocardial biopsies. Two-dimensional echocardiographic parameters were obtained from routine examinations. Results. There were no significant differences regarding right atrial pressure, systolic pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, cardiac index, systolic blood pressure, left ventricular ejection fraction, and mitral regurgitation (P > .05). Tricuspid regurgitation increased significantly over the 3 years of observation only among the biatrial group (P = .0212). In both groups, the right atrial pressure, pulmonary wedge capillary pressure, transpulmonary gradient, and pulmonary vascular resistance decreased significantly (P < .05) from the pre- to the postoperative examination. In both groups cardiac index and systemic blood pressure increased significantly after transplantation (P < .05). Comparative analysis of the groups only showed significant differences regarding right atrial pressure and degree of tricuspid regurgitation; the bicaval group showing the best performance. Conclusions. Both surgical techniques ensure adequate left ventricular function in the long term; however, the bicaval technique provided better trends in hemodynamic performance, as well as a lower incidence and severity of tricuspid valve dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flux of a compound across a membrane from any formulation, whether it contains penetration enhancers or not, is limited by its saturated solubility in the vehicle. Under such conditions the concentration of the permeant in the outer layers of the stratum corneum is also saturated. Consequently, when the permeation of a drug from a supersaturated solution leads to enhanced penetration, the concentration of the drug in the outer layers of the membrane is also supersaturated. Therefore, the stratum corneum may possess antinucleant properties which inhibit or retard the crystallisation process. In this study, the enhanced in vitro permeation of supersaturated solutions of piroxicam across human skin in diffusion cells was demonstrated. The amount of permeant in the stratum corneum was determined using a tape stripping technique. Supersaturated solutions up to four degrees of saturation were investigated which produced a linear relationship between the degree of saturation and the amount of piroxicam in the stratum corneum (R-2 = 0.970). Furthermore, the amount of piroxicam in the viable layers of the skin also increased with increasing degree of saturation. An analysis of the results suggested that enhanced penetration across human skin from supersaturated solutions of piroxicam may occur as a result of the antinucleating ability of the intercellular lipids of the stratum corneum. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Annular pancreas is a rare congenital anomaly, which is only surgically treated in symptomatic cases. Surgical treatment consists of bypassing the duodenal transit by gastrojejunal or duodenal-jejunal anastomosis. In the absolute majority of published cases, laparotomy is the most widely used access technique. The aim of this article is to report a case of an annular pancreas and describe the technical steps involved in carrying out a laparoscopic duodenal-jejunal anastomosis, for correction of the duodenal obstruction. The patient`s recovery was uneventful; she was discharged on the fourth postoperative day and remained asymptomatic for the 2-year, outpatient follow-up period. Laparoscopic duodenal-jejunal bypass is shown to be feasible and safe, and produce less surgical trauma, when carried out by an experienced surgeon who is duly trained and familiar with the laparoscopic technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time evolution of the populations of the collective states of a two-atom system in a squeezed vacuum can exhibit quantum beats. We show that the effect appears only when the carrier frequency of the squeezed field is detuned from the atomic resonance. Moreover, we find that the quantum beats are not present for the case in which the two-photon correlation strength is the maximum possible for a field with a classical analog. We also show that the population inversion between the excited collective states, found for the resonant squeezed vacuum, is sensitive to the detuning and the two-photon correlations. For large detunings or a field with a classical analog there is no inversion between the collective states. Observation of the quantum beats or the population inversion would confirm the essentially quantum-mechanical nature of the squeezed vacuum. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine subnatural phase-dependent linewidths in the fluorescence spectrum of a three-level atom damped by a narrow-bandwidth squeezed vacuum in a cavity. Using the dressed-atom model approach of a strongly driven three-level cascade system, we derive the master equation of the system from which we obtain simple analytical expressions for the fluorescence spectrum. We show that the phase effects depend on the bandwidths of the squeezed vacuum and the cavity relative to the Rabi frequency of the driving fields. When the squeezing bandwidth is much larger than the Rabi frequency, the spectrum consists of five lines with only the central and outer sidebands dependent on the phase. For a squeezing bandwidth much smaller than the Rabi frequency the number of lines in the spectrum and their phase properties depend on the frequency at which the squeezing and cavity modes are centered. When the squeezing and cavity modes are centered on the inner Rabi sidebands, the spectrum exhibits five lines that are completely independent of the squeezing phase with only the inner Rabi sidebands dependent on the squeezing correlations. Matching the squeezing and cavity modes to the outer Rabi sidebands leads to the disappearance of the inner Rabi sidebands and a strong phase dependence of the central line and the outer Rabi sidebands. We find that in this case the system behaves as an individual two-level system that reveals exactly the noise distribution in the input squeezed vacuum. [S1050-2947(97)00111-X].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although various techniques have been used for breast conservation surgery reconstruction, there are few studies describing a logical approach to reconstruction of these defects. The objectives of this study were to establish a classification system for partial breast defects and to develop a reconstructive algorithm. Methods: The authors reviewed a 7-year experience with 209 immediate breast conservation surgery reconstructions. Mean follow-up was 31 months. Type I defects include tissue resection in smaller breasts (bra size A/B), including type IA, which involves minimal defects that do not cause distortion; type III, which involves moderate defects that cause moderate distortion; and type IC, which involves large defects that cause significant deformities. Type II includes tissue resection in medium-sized breasts with or without ptosis (bra size C), and type III includes tissue resection in large breasts with ptosis (bra size D). Results: Eighteen percent of patients presented type I, where a lateral thoracodorsal flap and a latissimus dorsi flap were performed in 68 percent. Forty-five percent presented type II defects, where bilateral mastopexy was performed in 52 percent. Thirty-seven percent of patients presented type III distortion, where bilateral reduction mammaplasty was performed in 67 percent. Thirty-five percent of patients presented complications, and most were minor. Conclusions: An algorithm based on breast size in relation to tumor location and extension of resection can be followed to determine the best approach to reconstruction. The authors` results have demonstrated that the complications were similar to those in other clinical series. Success depends on patient selection, coordinated planning with the oncologic surgeon, and careful intraoperative management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Several studies have already reported the utilization of fibrin glue in microvascular anastomoses to minimize the number of sutures and to decrease the operative time. Despite the good results obtained in most of these experiments, its clinical application has not launched. The aim of this study was to clarify the controversies around the safeness of fibrin glue application in microvascular anastomoses, and also to demonstrate the potential benefits of fibrin glue application in a realistic free flap model. Methods: Twenty-seven rabbits were used in this study The experimental model consisted of a free groin flap transfer to the anterior cervical region. The flap`s circulation was restored by means of an end-to-side anastomosis between the femoral and carotid arteries, and an end-to-end anastomosis between the femoral and external jugular veins. The animals were divided into two groups (n = 10) according to the anastomosis technique: Group I (conventional suture) and group 11 (fibrin glue). Results: The number of sutures required to complete the arterial and venous anastomoses was reduced in 39 and 37% in group 11, respectively. Despite this reduction, the anastomoses maintained adequate patency rates and mechanical strength. Both arterial and venous anastomoses benefited from fibrin glue application, which made them easier and faster to perform. The flaps` ischemic time and the total operative time were also significantly shortened. Conclusions: In this study, the application of fibrin glue in microvascular anastomoses was safe and reliable. The risk-benefit ratio of fibrin glue application in microvascular anastomoses is favorable for its use. (c) 2008 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Bariatric surgery (BS) was recognized as the only treatment for morbid obesity in adolescents. Classic surgical procedures are based on mechanical restriction and/or malabsorption, resulting in a large number of possible complications and demanding lifelong medical attention. A novel BS design, the Santoro III procedure, relies on modifying secretion of the satiogenic hormones GLP-1 and PYY. This approach avoids common BS complications such as prostheses, narrow anastomoses, excluded segments, and malabsorption. This study describes the 1-year follow-up of the first ten adolescents operated on using the Santoro III technique in a pediatric surgical service. Methods Ten adolescents, mean age 16.1 +/- 1.7 years with body mass index (BMI) greater than 40 kg/m(2) (range 44 to 72 kg/m(2)), refractory to at least 2 years of medical weight loss treatment were selected by a multidisciplinary team to undergo BS. This operation consists of a sleeve gastrectomy with enteroomentectomy and partial gastro-ileal derivation. Results After 1 year, mean body weight decreased from 140.3 to 88.6 kg, and BMI decreased from 52.8 +/- 9.5 kg/m(2) to 33.4 +/- 7.7 kg/m(2), with percent of excess BMI lost as 83.9 +/- 17.1%. Glucose, insulin, total cholesterol, LDL-cholesterol, and triglyceride levels decreased significantly, while HDL-cholesterol, hemoglobin, and albumin levels remained unchanged. There were no mortalities or reoperations. The two complications that presented during the trial (intraperitoneal abscess and polyneuritis) resolved with medical treatment without sequelae. All the patients returned to their normal activities and their BMI began to stabilize approximately 2 years following surgery. Conclusions The Santoro III procedure is an attractive option for adolescent BS, with promising 1-year follow-up results. These initial studies should be monitored for long-term outcomes and confirmed on a larger group of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and study aims In many patients, percutaneous endoscopic gastrostomy (PEG) can be limited by digestive tract stenosis. PEG placement using an introducer is the safest alternative for this group of patients, but the available devices are difficult to implement and require smaller-caliber tubes. The aim of this study was to evaluate the modification of an introducer technique device for PEG placement with regard to the following: procedure feasibility, possibility of using a 20-Fr balloon gastrostomy tube, tube-related function and problems, complications, procedure safety, and mortality. Patients and methods Between March 2007 and February 2008, 30 consecutive patients with head and neck malignancies underwent introducer PEG placement with the modified device and gastropexy. Each patient was evaluated for 60 days after the procedure for the success of the procedure, infection, pain, complications, mortality, and problems with the procedure. Results The procedure was successful in all cases with no perioperative complications. No signs of stomal infection were observed using the combined infection score. The majority of patients experienced mild-to-moderate pain both in the immediate postoperative period and at 72 hours. One major early complication (3.3%) and two minor complications (6.7%) were observed. No procedure-related deaths occurred during the first 60 days after the procedure. Conclusion The device modification for PEG using the introducer technique is feasible, safe, and efficient in outpatients with obstructive head and neck cancer. In this series, it allowed the use of a larger-caliber tube with low complication rates and no procedure-related mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/purpose: The introduction of the piggyback technique for reconstruction of the liver outflow in reduced-size liver transplants for pediatric patients has increased the incidence of hepatic venous outflow block (HVOB). Here, we proposed a new technique for hepatic venous reconstruction in pediatric living-donor liver transplantation. Methods: Three techniques were used: direct anastomosis of the orifice of the donor hepatic veins and the orifice of the recipient hepatic veins (group 1); triangular anastomosis after creating a wide triangular orifice in the recipient inferior vena cava at the confluence of all the hepatic veins (group 2); and a new technique, which is a wide longitudinal anastomosis performed at the anterior wall of the inferior vena cava (group 3). Results: In groups 1 and 2, the incidences of HVOB were 27.7% and 5.7%, respectively. In group 3, no patient presented HVOB (P = .001). No difference was noted between groups 2 and 3. Conclusions: Hepatic venous reconstruction in pediatric living-donor liver transplantation must be preferentially performed by using a wide longitudinal incision at the anterior wall of the recipient inferior vena cava. As an alternative technique, triangulation of the recipient inferior vena cava, including the orifices of the 3 hepatic veins, may be used. Published by Elsevier Inc.