988 resultados para uneven lighting image correction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This contribution discusses the effects of camera aperture correction in broadcast video on colour-based keying. The aperture correction is used to ’sharpen’ an image and is one element that distinguishes the ’TV-look’ from ’film-look’. ’If a very high level of sharpening is applied, as is the case in many TV productions then this significantly shifts the colours around object boundaries with hight contrast. This paper discusses these effects and their impact on keying and describes a simple low-pass filter to compensate for them. Tests with colour-based segmentation algorithms show that the proposed compensation is an effective way of decreasing the keying artefacts on object boundaries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to display a homogeneous image using multiple projectors, differences in the projected intensities must be compensated. In this paper, we present novel approaches to combine and extend existing techniques for edge blending and luminance harmonization to achieve a detailed luminance control. Furthermore, we apply techniques for improving the contrast ratio of multi-segmented displays also to the black offset correction. We also present a simple scheme to involve the displayed context in the correction process to dynamically improve the contrast in brighter images. In addition, we present a metric to evaluate the different methods and their influence on the visual quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water flow and solute transport through soils are strongly influenced by the spatial arrangement of soil materials with different hydraulic and chemical properties. Knowing the specific or statistical arrangement of these materials is considered as a key toward improved predictions of solute transport. Our aim was to obtain two-dimensional material maps from photographs of exposed profiles. We developed a segmentation and classification procedure and applied it to the images of a very heterogeneous sand tank, which was used for a series of flow and transport experiments. The segmentation was based on thresholds of soil color, estimated from local median gray values, and of soil texture, estimated from local coefficients of variation of gray values. Important steps were the correction of inhomogeneous illumination and reflection, and the incorporation of prior knowledge in filters used to extract the image features and to smooth the results morphologically. We could check and confirm the success of our mapping by comparing the estimated with the designed sand distribution in the tank. The resulting material map was used later as input to model flow and transport through the sand tank. Similar segmentation procedures may be applied to any high-density raster data, including photographs or spectral scans of field profiles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Quantitative myocardial PET perfusion imaging requires partial volume corrections. METHODS: Patients underwent ECG-gated, rest-dipyridamole, myocardial perfusion PET using Rb-82 decay corrected in Bq/cc for diastolic, systolic, and combined whole cycle ungated images. Diastolic partial volume correction relative to systole was determined from the systolic/diastolic activity ratio, systolic partial volume correction from phantom dimensions comparable to systolic LV wall thicknesses and whole heart cycle partial volume correction for ungated images from fractional systolic-diastolic duration for systolic and diastolic partial volume corrections. RESULTS: For 264 PET perfusion images from 159 patients (105 rest-stress image pairs, 54 individual rest or stress images), average resting diastolic partial volume correction relative to systole was 1.14 ± 0.04, independent of heart rate and within ±1.8% of stress images (1.16 ± 0.04). Diastolic partial volume corrections combined with those for phantom dimensions comparable to systolic LV wall thickness gave an average whole heart cycle partial volume correction for ungated images of 1.23 for Rb-82 compared to 1.14 if positron range were negligible as for F-18. CONCLUSION: Quantitative myocardial PET perfusion imaging requires partial volume correction, herein demonstrated clinically from systolic/diastolic absolute activity ratios combined with phantom data accounting for Rb-82 positron range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Source materials like fine art, over-sized, fragile maps, and delicate artifacts have traditionally been digitally converted through the use of controlled lighting and high resolution scanners and camera backs. In addition the capture of items such as general and special collections bound monographs has recently grown both through consortial efforts like the Internet Archive's Open Content Alliance and locally at the individual institution level. These projects, in turn, have introduced increasingly higher resolution consumer-grade digital single lens reflex cameras or "DSLRs" as a significant part of the general cultural heritage digital conversion workflow. Central to the authors' discussion is the fact that both camera backs and DSLRs commonly share the ability to capture native raw file formats. Because these formats include such advantages as access to an image's raw mosaic sensor data within their architecture, many institutions choose raw for initial capture due to its high bit-level and unprocessed nature. However to date these same raw formats, so important to many at the point of capture, have yet to be considered "archival" within most published still imaging standards, if they are considered at all. Throughout many workflows raw files are deleted and thrown away after more traditionally "archival" uncompressed TIFF or JPEG 2000 files have been derived downstream from their raw source formats [1][2]. As a result, the authors examine the nature of raw anew and consider the basic questions, Should raw files be retained? What might their role be? Might they in fact form a new archival format space? Included in the discussion is a survey of assorted raw file types and their attributes. Also addressed are various sustainability issues as they pertain to archival formats with a special emphasis on both raw's positive and negative characteristics as they apply to archival practices. Current common archival workflows versus possible raw-based ones are investigated as well. These comparisons are noted in the context of each approach's differing levels of usable captured image data, various preservation virtues, and the divergent ideas of strictly fixed renditions versus the potential for improved renditions over time. Special attention is given to the DNG raw format through a detailed inspection of a number of its various structural components and the roles that they play in the format's latest specification. Finally an evaluation is drawn of both proprietary raw formats in general and DNG in particular as possible alternative archival formats for still imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Accurate projection of implanted subdural electrode contacts in presurgical evaluation of pharmacoresistant epilepsy cases by invasive EEG is highly relevant. Linear fusion of CT and MRI images may display the contacts in the wrong position due to brain shift effects. OBJECTIVE: A retrospective study in five patients with pharmacoresistant epilepsy was performed to evaluate whether an elastic image fusion algorithm can provide a more accurate projection of the electrode contacts on the pre-implantation MRI as compared to linear fusion. METHODS: An automated elastic image fusion algorithm (AEF), a guided elastic image fusion algorithm (GEF), and a standard linear fusion algorithm (LF) were used on preoperative MRI and post-implantation CT scans. Vertical correction of virtual contact positions, total virtual contact shift, corrections of midline shift and brain shifts due to pneumencephalus were measured. RESULTS: Both AEF and GEF worked well with all 5 cases. An average midline shift of 1.7mm (SD 1.25) was corrected to 0.4mm (SD 0.8) after AEF and to 0.0mm (SD 0) after GEF. Median virtual distances between contacts and cortical surface were corrected by a significant amount, from 2.3mm after LF to 0.0mm after AEF and GEF (p<.001). Mean total relative corrections of 3.1 mm (SD 1.85) after AEF and 3.0mm (SD 1.77) after GEF were achieved. The tested version of GEF did not achieve a satisfying virtual correction of pneumencephalus. CONCLUSION: The technique provided a clear improvement in fusion of pre- and post-implantation scans, although the accuracy is difficult to evaluate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To investigate if non-rigid image-registration reduces motion artifacts in triggered and non-triggered diffusion tensor imaging (DTI) of native kidneys. A secondary aim was to determine, if improvements through registration allow for omitting respiratory-triggering. METHODS: Twenty volunteers underwent coronal DTI of the kidneys with nine b-values (10-700 s/mm2 ) at 3 Tesla. Image-registration was performed using a multimodal nonrigid registration algorithm. Data processing yielded the apparent diffusion coefficient (ADC), the contribution of perfusion (FP ), and the fractional anisotropy (FA). For comparison of the data stability, the root mean square error (RMSE) of the fitting and the standard deviations within the regions of interest (SDROI ) were evaluated. RESULTS: RMSEs decreased significantly after registration for triggered and also for non-triggered scans (P < 0.05). SDROI for ADC, FA, and FP were significantly lower after registration in both medulla and cortex of triggered scans (P < 0.01). Similarly the SDROI of FA and FP decreased significantly in non-triggered scans after registration (P < 0.05). RMSEs were significantly lower in triggered than in non-triggered scans, both with and without registration (P < 0.05). CONCLUSION: Respiratory motion correction by registration of individual echo-planar images leads to clearly reduced signal variations in renal DTI for both triggered and particularly non-triggered scans. Secondarily, the results suggest that respiratory-triggering still seems advantageous.J. Magn. Reson. Imaging 2014. (c) 2014 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aberrations of the acoustic wave front, caused by spatial variations of the speed-of-sound, are a main limiting factor to the diagnostic power of medical ultrasound imaging. If not accounted for, aberrations result in low resolution and increased side lobe level, over all reducing contrast in deep tissue imaging. Various techniques have been proposed for quantifying aberrations by analysing the arrival time of coherent echoes from so-called guide stars or beacons. In situations where a guide star is missing, aperture-based techniques may give ambiguous results. Moreover, they are conceptually focused on aberrators that can be approximated as a phase screen in front of the probe. We propose a novel technique, where the effect of aberration is detected in the reconstructed image as opposed to the aperture data. The varying local echo phase when changing the transmit beam steering angle directly reflects the varying arrival time of the transmit wave front. This allows sensing the angle-dependent aberration delay in a spatially resolved way, and thus aberration correction for a spatially distributed volume aberrator. In phantoms containing a cylindrical aberrator, we achieved location-independent diffraction-limited resolution as well as accurate display of echo location based on reconstructing the speed-of-sound spatially resolved. First successful volunteer results confirm the clinical potential of the proposed technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Wadden Sea is located in the southeastern part of the North Sea forming an extended intertidal area along the Dutch, German and Danish coast. It is a highly dynamic and largely natural ecosystem influenced by climatic changes and anthropogenic use of the North Sea. Changes in the environment of the Wadden Sea, natural or anthropogenic origin, cannot be monitored by the standard measurement methods alone, because large-area surveys of the intertidal flats are often difficult due to tides, tidal channels and unstable underground. For this reason, remote sensing offers effective monitoring tools. In this study a multi-sensor concept for classification of intertidal areas in the Wadden Sea has been developed. Basis for this method is a combined analysis of RapidEye (RE) and TerraSAR-X (TSX) satellite data coupled with ancillary vector data about the distribution of vegetation, mussel beds and sediments. The classification of the vegetation and mussel beds is based on a decision tree and a set of hierarchically structured algorithms which use object and texture features. The sediments are classified by an algorithm which uses thresholds and a majority filter. Further improvements focus on radiometric enhancement and atmospheric correction. First results show that we are able to identify vegetation and mussel beds with the use of multi-sensor remote sensing. The classification of the sediments in the tidal flats is a challenge compared to vegetation and mussel beds. The results demonstrate that the sediments cannot be classified with high accuracy by their spectral properties alone due to their similarity which is predominately caused by their water content.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This airborne hyperspectral (19 bands) image data of Heron Reef, Great Barrier Reef, Australia is derived from Compact Airborne Spectrographic Imager (CASI) data acquired on 1st and 3rd of July 2002, latitude -23.45, longitude 151.92. Processing and correction to at-surface data was completed by Karen Joyce (Joyce, 2004). Raw imagery consisted several images corresponding to the number of flight paths taken to cover the entire Heron Reef. Spatial resolution is one meter. Radiometric corrections converted the at-sensor digital number values to at surface spectral radiance values using sensor specific calibration coefficients and CSIRO's c-WomBat-c atmospheric correction software. Geometric corrections were done using field collected coordinates of features identified in the image. Projection used was Universal Transverse Mercator Zone 56 South and Datum used was WGS 84. Image data is in TIFF format.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for fast colour and geometric correction of a tiled display system is presented in this paper. Such kind of displays are a common choice for virtual reality applications and simulators, where a high resolution image is required. They are the cheapest and more flexible alternative for large image generation but they require a precise geometric and colour correction. The purpose of the proposed method is to correct the projection system as fast as possible so in case the system needs to be recalibrated it doesn’t interfere with the normal operation of the simulator or virtual reality application. This technique makes use of a single conventional webcam for both geometric and photometric correction. Some previous assumptions are made, like planar projection surface and negligibleintra-projector colour variation and black-offset levels. If these assumptions hold true, geometric and photometric seamlessness can be achievedfor this kind of display systems. The method described in this paper is scalable for an undefined number of projectors and completely automatic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Determination of the soil coverage by crop residues after ploughing is a fundamental element of Conservation Agriculture. This paper presents the application of genetic algorithms employed during the fine tuning of the segmentation process of a digital image with the aim of automatically quantifying the residue coverage. In other words, the objective is to achieve a segmentation that would permit the discrimination of the texture of the residue so that the output of the segmentation process is a binary image in which residue zones are isolated from the rest. The RGB images used come from a sample of images in which sections of terrain were photographed with a conventional camera positioned in zenith orientation atop a tripod. The images were taken outdoors under uncontrolled lighting conditions. Up to 92% similarity was achieved between the images obtained by the segmentation process proposed in this paper and the templates made by an elaborate manual tracing process. In addition to the proposed segmentation procedure and the fine tuning procedure that was developed, a global quantification of the soil coverage by residues for the sampled area was achieved that differed by only 0.85% from the quantification obtained using template images. Moreover, the proposed method does not depend on the type of residue present in the image. The study was conducted at the experimental farm “El Encín” in Alcalá de Henares (Madrid, Spain).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a computer vision system that successfully discriminates between weed patches and crop rows under uncontrolled lighting in real-time. The system consists of two independent subsystems, a fast image processing delivering results in real-time (Fast Image Processing, FIP), and a slower and more accurate processing (Robust Crop Row Detection, RCRD) that is used to correct the first subsystem's mistakes. This combination produces a system that achieves very good results under a wide variety of conditions. Tested on several maize videos taken of different fields and during different years, the system successfully detects an average of 95% of weeds and 80% of crops under different illumination, soil humidity and weed/crop growth conditions. Moreover, the system has been shown to produce acceptable results even under very difficult conditions, such as in the presence of dramatic sowing errors or abrupt camera movements. The computer vision system has been developed for integration into a treatment system because the ideal setup for any weed sprayer system would include a tool that could provide information on the weeds and crops present at each point in real-time, while the tractor mounting the spraying bar is moving

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different procedures for monitoring the evolution of leafy vegetables, under plastic covers during cold storage, have been studied. Fifteen spinach leaves were put inside Petri dishes covered with three different plastic films and stored at 4 °C for 21 days. Hyperspectral images were taken during this storage. A radiometric correction is proposed in order to avoid the variation in transmittance of the plastic films during time in the hyperspectral images. Afterwards, three spectral pre-processing procedures (no pre-process, Savitsky–Golay and Standard Normal Variate, combined with Principal Component Analysis) were applied to obtain different models. The corresponding artificial images of scores were studied by means of Analysis of Variance to compare their ability to sense the aging of the leaves. All models were able to monitor the aging through storage. Radiometric correction seemed to work properly and could allow the supervision of shelf-life in leafy vegetables through commercial transparent films.