964 resultados para true isidium
Resumo:
Folliculo-stellate cells are a nonendocrine, sustentacular-like complementary population of the anterior pituitary. They currently are considered as functionally and phenotypically heterogeneous, with one subpopulation of folliculo-stellate cells possibly representing resident adenohypophyseal macrophages. We took advantage of a limited T-cell mediated inflammatory reaction selectively involving tumor tissue in three cases of pituitary adenoma (2 prolactin cell adenomas, and 1 null cell adenoma) to test the hypothesis whether some folliculo-stellate cells within inflammatory foci would also assume monocytic/dendritic properties. Immunohistochemical double labeling for S-100 protein and the class II major histocompatibility antigen HLA-DR indeed showed several arborized cells to coexpress both epitopes. These were distributed both amidst adenomatous acini and along intratumoral vessels, and were morphologically undistinguishable from conventional folliculo-stellate cells. On the other hand, markers of follicular dendritic cells (CD21) and Langerhans' cells (CD1a) tested negative. Furthermore, no S-100/HLA-DR coexpressing folliculo-stellate cells were seen in either peritumoral parenchyma of the cases in point nor in control pituitary adenomas lacking inflammatory reaction. These findings suggest that a subset of folliculo-stellate cells may be induced by an appropriate local inflammatory microenvironment to assume a dendritic cell-like immunophenotype recognizable by their coexpression of S-100 protein and HLA-DR. By analogy with HLA-DR expressing cells in well-established extrapituitary inflammatory constellations, we speculate that folliculo-stellate cells with such immunophenotype may actually perform professional antigen presentation. A distinctly uncommon finding in pituitary adenomas, lymphocytic infiltrates may therefore be read as a manifestation of tumoral immunosurveillance.
Resumo:
Mutations in the FBN1 gene are the major cause of Marfan syndrome (MFS), an autosomal dominant connective tissue disorder, which displays variable manifestations in the cardiovascular, ocular, and skeletal systems. Current molecular genetic testing of FBN1 may miss mutations in the promoter region or in other noncoding sequences as well as partial or complete gene deletions and duplications. In this study, we tested for copy number variations by successively applying multiplex ligation-dependent probe amplification (MLPA) and the Affymetrix Human Mapping 500 K Array Set, which contains probes for approximately 500,000 single-nucleotide polymorphisms (SNPs) across the genome. By analyzing genomic DNA of 101 unrelated individuals with MFS or related phenotypes in whom standard genetic testing detected no mutation, we identified FBN1 deletions in two patients with MFS. Our high-resolution approach narrowed down the deletion breakpoints. Subsequent sequencing of the junctional fragments revealed the deletion sizes of 26,887 and 302,580 bp, respectively. Surprisingly, both deletions affect the putative regulatory and promoter region of the FBN1 gene, strongly indicating that they abolish transcription of the deleted allele. This expectation of complete loss of function of one allele, i.e. true haploinsufficiency, was confirmed by transcript analyses. Our findings not only emphasize the importance of screening for large genomic rearrangements in comprehensive genetic testing of FBN1 but, importantly, also extend the molecular etiology of MFS by providing hitherto unreported evidence that true haploinsufficiency is sufficient to cause MFS.
Resumo:
RATIONALE AND OBJECTIVES: A feasibility study on measuring kidney perfusion by a contrast-free magnetic resonance (MR) imaging technique is presented. MATERIALS AND METHODS: A flow-sensitive alternating inversion recovery (FAIR) prepared true fast imaging with steady-state precession (TrueFISP) arterial spin labeling sequence was used on a 3.0-T MR-scanner. The basis for quantification is a two-compartment exchange model proposed by Parkes that corrects for diverse assumptions in single-compartment standard models. RESULTS: Eleven healthy volunteers (mean age, 42.3 years; range 24-55) were examined. The calculated mean renal blood flow values for the exchange model (109 +/- 5 [medulla] and 245 +/- 11 [cortex] ml/min - 100 g) are in good agreement with the literature. Most important, the two-compartment exchange model exhibits a stabilizing effect on the evaluation of perfusion values if the finite permeability of the vessel wall and the venous outflow (fast solution) are considered: the values for the one-compartment standard model were 93 +/- 18 (medulla) and 208 +/- 37 (cortex) ml/min - 100 g. CONCLUSION: This improvement will increase the accuracy of contrast-free imaging of kidney perfusion in treatment renovascular disease.
Resumo:
A Montana Public Radio Commentary by Evan Barrett. Published newspaper columns written by Evan Barrett on this topic, which vary somewhat in content from this commentary, appeared in the following publications: Montana Standard, March 18, 2014 Ravalli Republic, March 22, 2014 Missoulian, March 26, 2014
Resumo:
INTRODUCTION: Cartilage defects are common pathologies and surgical cartilage repair shows promising results. In its postoperative evaluation, the magnetic resonance observation of cartilage repair tissue (MOCART) score, using different variables to describe the constitution of the cartilage repair tissue and the surrounding structures, is widely used. High-field magnetic resonance imaging (MRI) and 3-dimensional (3D) isotropic sequences may combine ideal preconditions to enhance the diagnostic performance of cartilage imaging.Aim of this study was to introduce an improved 3D MOCART score using the possibilities of an isotropic 3D true fast imaging with steady-state precession (True-FISP) sequence in the postoperative evaluation of patients after matrix-associated autologous chondrocyte transplantation (MACT) as well as to compare the results to the conventional 2D MOCART score using standard MR sequences. MATERIAL AND METHODS: The study had approval by the local ethics commission. One hundred consecutive MR scans in 60 patients at standard follow-up intervals of 1, 3, 6, 12, 24, and 60 months after MACT of the knee joint were prospectively included. The mean follow-up interval of this cross-sectional evaluation was 21.4 +/- 20.6 months; the mean age of the patients was 35.8 +/- 9.4 years. MRI was performed at a 3.0 Tesla unit. All variables of the standard 2D MOCART score where part of the new 3D MOCART score. Furthermore, additional variables and options were included with the aims to use the capabilities of isotropic MRI, to include the results of recent studies, and to adapt to the needs of patients and physician in a clinical routine examination. A proton-density turbo spin-echo sequence, a T2-weighted dual fast spin-echo (dual-FSE) sequence, and a T1-weighted turbo inversion recovery magnitude (TIRM) sequence were used to assess the standard 2D MOCART score; an isotropic 3D-TrueFISP sequence was prepared to evaluate the new 3D MOCART score. All 9 variables of the 2D MOCART score were compared with the corresponding variables obtained by the 3D MOCART score using the Pearson correlation coefficient; additionally the subjective quality and possible artifacts of the MR sequences were analyzed. RESULTS: The correlation between the standard 2D MOCART score and the new 3D MOCART showed for the 8 variables "defect fill," "cartilage interface," "surface," "adhesions," "structure," "signal intensity," "subchondral lamina," and "effusion"-a highly significant (P < 0.001) correlation with a Pearson coefficient between 0.566 and 0.932. The variable "bone marrow edema" correlated significantly (P < 0.05; Pearson coefficient: 0.257). The subjective quality of the 3 standard MR sequences was comparable to the isotropic 3D-TrueFISP sequence. Artifacts were more frequently visible within the 3D-TrueFISP sequence. CONCLUSION: In the clinical routine follow-up after cartilage repair, the 3D MOCART score, assessed by only 1 high-resolution isotropic MR sequence, provides comparable information than the standard 2D MOCART score. Hence, the new 3D MOCART score has the potential to combine the information of the standard 2D MOCART score with the possible advantages of isotropic 3D MRI at high-field. A clear limitation of the 3D-TrueFISP sequence was the high number of artifacts. Future studies have to prove the clinical benefits of a 3D MOCART score.
Resumo:
INTRODUCTION Patients who are lost to follow-up (LTFU) while on antiretroviral therapy (ART) pose challenges to the long-term success of ART programs. We describe the extent to which patients considered LTFU are misclassified as true disengagement from care when they are still alive on ART and explain reasons for ART discontinuation using our active tracing program to further improve ART retention programs and policies. METHODS We identified adult ART patients who missed clinic appointment by more than 3 weeks between January 2006 and December 2010, assuming that such patients would miss their doses of antiretroviral drugs. Patients considered LTFU who consented during ART registration were traced by phone or home visits; true ART status after tracing was documented. Reasons for ART discontinuation were also recorded for those who stopped ART. RESULTS Of the 4,560 suspected LTFU cases, 1,384 (30%) could not be traced. Of the 3,176 successfully traced patients, 952 (30%) were dead and 2,224 (70%) were alive, of which 2,183 (99.5%) started ART according to phone-based self-reports or physical verification during in-person interviews. Of those who started ART, 957 (44%) stopped ART and 1,226 (56%) reported still taking ART at the time of interview by sourcing drugs from another clinic, using alternative ART sources or making brief ART interruptions. Among 940 cases with reasons for ART discontinuations, failure to remember (17%), too weak/sick (12%), travel (46%), and lack of transport to the clinic (16%) were frequently cited; reasons differed by gender. CONCLUSION The LTFU category comprises sizeable proportions of patients still taking ART that may potentially bias retention estimates and misdirect resources at the clinic and national levels if not properly accounted for. Clinics should consider further decentralization efforts, increasing drug allocations for frequent travels, and improving communication on patient transfers between clinics to increase retention and adherence.
Resumo:
Pulmonary artery aneurysm in adults is a rare diagnosis. Most cases described in the literature are either associated with congenital heart disease or pulmonal arterial hypertension, respectively, or are not true aneurysms but rather pseudoaneurysms, which are usually iatrogenic. We present the case of a 68-year old female patient with the incidental finding of a true aneurysm of the right peripheral pulmonary artery with a maximum diameter of 4 cm. With increasing aneurysm diameter over time, the decision for a surgical resection was made. Complete resection of the aneurysm including lower lobe resection was performed. Histopathological examination showed necrotizing giant cell arteritis as the underlying cause. The postoperative course was uneventful and no signs of further disease activity were detected. To our knowledge, this is the first reported case of a pulmonary artery aneurysm caused by giant cell arteritis, whereas it should be noted that the distinction between Takayasu arteritis and giant cell arteritis is not clearly defined. Considering the high mortality associated with aneurysm rupture, surveillance is advocated for small aneurysms, whereas for larger aneurysms and those showing signs of progression in size despite medical therapy or even dissection, surgical intervention should be considered.
Resumo:
BACKGROUND Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. METHODS In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. RESULTS Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. CONCLUSIONS The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.
Resumo:
Previous analyses of aortic displacement and distension using computed tomography angiography (CTA) were performed on double-oblique multi-planar reformations and did not consider through-plane motion. The aim of this study was to overcome this limitation by using a novel computational approach for the assessment of thoracic aortic displacement and distension in their true four-dimensional extent. Vessel segmentation with landmark tracking was executed on CTA of 24 patients without evidence of aortic disease. Distension magnitudes and maximum displacement vectors (MDV) including their direction were analyzed at 5 aortic locations: left coronary artery (COR), mid-ascending aorta (ASC), brachiocephalic trunk (BCT), left subclavian artery (LSA), descending aorta (DES). Distension was highest for COR (2.3 ± 1.2 mm) and BCT (1.7 ± 1.1 mm) compared with ASC, LSA, and DES (p < 0.005). MDV decreased from COR to LSA (p < 0.005) and was highest for COR (6.2 ± 2.0 mm) and ASC (3.8 ± 1.9 mm). Displacement was directed towards left and anterior at COR and ASC. Craniocaudal displacement at COR and ASC was 1.3 ± 0.8 and 0.3 ± 0.3 mm. At BCT, LSA, and DES no predominant displacement direction was observable. Vessel displacement and wall distension are highest in the ascending aorta, and ascending aortic displacement is primarily directed towards left and anterior. Craniocaudal displacement remains low even close to the left cardiac ventricle.
Resumo:
by Michael Davitt
Resumo:
Although brand authenticity is gaining increasing interest in academia and managerial practice, empirical studies on its contribution to the branding literature are still limited. The authors therefore conceptually and empirically examine the emergence and outcomes of perceived brand authenticity (PBA). A prior multi-phase scale development process resulted in a 17-item PBA scale to measure its four dimensions of credibility, integrity, symbolism, and longevity. Brand authenticity perceptions are influenced by indexical, existential, and iconic cues, whereby the latter’s influence is moderated by consumers’ level of marketing skepticism. Further, PBA increases emotional brand attachment. This relationship is particularly strong for consumers with a high level of self-authenticity. In addition, PBA effects are stronger in a North American market context compared to a European context.