861 resultados para thermal comfort index


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents the results of a numerical and experimental study of phase change material (PCM) filled walls and roofs under real operational conditions to achieve passive thermal comfort. The numerical part of the study was based on a one-dimensional model for the phase change problem controlled by pure conduction. Real radiation data was used to determine the external face temperature. The numerical treatment was based upon using finite difference approximations and the ADI scheme. The results obtained were compared with field measurements. The experimental set-up consisted of a small room with movable roof and side wall. The roof was constructed in the traditional way but with the phase change material enclosed. Thermocouples were distributed across the cross section of the roof. Another roof, identical but without the PCM, was also used during comparative tests. The movable wall was also constructed as is done traditionally but with the PCM enclosed. Again, thermocouples were distributed across the wall thickness to enable measurement of the local temperatures. Another wall, identical but without the PCM, was also used during comparative tests. The PCM used in the numerical and experimental tests was composed of a mixture of two commercial grades of glycol in order to obtain the required fusion temperature range. Comparison between the simulation results and the experiments indicated good agreement. Field tests also indicated that the PCM used was adequate and that the concept was effective in maintaining the indoor temperature very close to the established comfort limits. Further economical analysis indicated that the concept could effectively help in reducing the electric energy consumption and improving the energy demand pattern. © 1997 by John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A methodology for analyzing the solar access and its influence on both air temperature and thermal comfort of the urban environment was here developed by applying the potentiality of GIS tools. Urban canyons in a specific area of a Brazilian medium sized city were studied. First, a computational algorithm was applied in order to allow the determination of sky view factors (SVF) and sun-paths in urban canyons. Then, air temperatures in 40 measurement points were collected within the study area. Solar radiation values of these canyons were determined and subsequently stored in a GIS database. The creation of thermal maps for the whole neighbourhood was possible due to a statistical treatment of the data, by promoting the interpolation of values. All data could then be spatially cross-examined. In addition, thermal comfort maps for summer and winter periods were generated. The methodology allowed the identification of thermal tendencies within the neighbourhood, what can be useful in the conception of guidelines for urban planning purposes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

ArcTech is a software being developed, applied and improved with the aim of becoming an efficient sensitization tool to support the teaching-learning process of Architecture courses. The application deals initially with the thermal comfort of buildings. The output generated by the software shows if a student is able to produce a pleasant environment, in terms of thermal sensation along a 24-hours period. Although one can find the very same characteristics in fully-developed commercial software, the reason to create ArcTech is related to the flexibility of the system to be adapted by the instructor and also to the need of simple tools for the evaluation of specific topics along the courses. The first part of ArcTech is dedicated to data management and that was developed using the visual programming language Delphi 7 and Firebird as the database management system. The second part contains the parameters that can be changed by the system administrator and those related to project visualization. The interface of the system, in which the student will learn how to implement and to evaluate the project alternatives, was built using Macromedia Flash. The software was applied to undergraduate students revealing its easy-learning and easy-teaching interface.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Poulty house typology and the materials used (mainly for roofing) are the determining factors for an appropriate thermal condition aiming at production. In this context, the main point of this paper was to identify differences in the internal environment of two poultry houses, using monitoring and afterwards using statistics for comparing the environmental variables. The data analyzed did not show evidence of better thermal comfort for the house which was covered with ceramic roofing tile, because this house did not have ridged vents, making the hot air exit from the house difficult by the chimney effect. The ammonia concentration measured inside both houses was within the comfort limit. The temperature and humidity index of the house covered with ceramic roofing tiles was higher than the house which was covered with cement asbestos roofing tile, even though lower temperature on the tiles' surfaces was verified, showing the positive effects of the use of ridge vents at the housing. Based on the results obtained it is recommended for the Bastos, SP region, that poulty houses should be built with the ridge vent and long eaves beyond the roof of ceramic tiles.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The introduction of wool sheep in warm temperature regions of Brazil has also raised concerns regarding the warm stress and its consequent decrease in animal production. The understanding of the physiology of thermal balance in sheep, as well as the consequences of this phenomenon, should be studied in order to improve animal thermal comfort in association with the production and reproduction indices of these animals. The majority of available research findings related to thermal balance in sheep is derived from countries with temperate climates and therefore might be different from those performed in our climate conditions. This essay presents a literature review that intends to discuss this theme.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The research aimed to evaluate the relationship between the thermal environment of the rest pens in a pig slaughterhouse and the surface temperature (ST) of the animals as well as the effect of intermittent water spraying on thermal comfort. There were two visits to slaughter industrial being in each selected three pens of rest, one for control treatment (no spray throughout the period) and two for the treatment of intermittent spraying water (30 minutes intervals with constant spray followed by 30 minutes then turned off). Assessments began at the time of discharging animals in which are taken the thermographic images from lots using an infrared thermographic camera. After housing in the pens, were registered the thermographic images and the respiratory frequency (RF) every five minutes for four hours. Were evaluated the temperature, relative humidity and temperature-humidity index (THI). Considering the values of THI was observed that the animals remained in a condition of comfort only at the time of his arrival at the slaughterhouse. The ST and RF of the animals kept in the pens without sprinkler system (control) showed a linear increase in function of time of day, with increasing temperature. The treatment with intermittent sprinkling of water was observed oscillatory behavior of the ST and RF, however it was always lower than the control treatment, even in times when the water sprinklers were turned off. The time required of spray to reduction and stabilization of the ST of the animals was limited to the combination of temperature and relative humidity, being estimated at 25 minutes at times of higher THI. The maximum environmental temperature during evaluation was 28.4 oC.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Arquitetura e Urbanismo - FAAC

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This research presents a study of roof thermal efficiency in individual housing for calves exposed to sun and shade through infrared thermography, internal temperature and thermal comfort indexes. Four different individual housing for calves covered with asbestos-free fiber-cement corrugated sheets were evaluated. Three of them were directly exposed to the sun: (i) corrugated sheets painted white in the external surface, (ii) corrugated sheets without painting and (iii) with screen shade fabric installed 0.10m under de internal surface of the corrugated sheet. The fourth individual housing was installed in the shade area and covered with unpainted corrugated fiber-cement sheets. The analysis was taken for 21 days at 11h00min, 14h00min and 17h00min. The results indicate significant variations in the roofing surface temperature and thermal comfort indexes among the treatments exposed to the sun and shade, for all the evaluations during the day. The infrared thermography images were effective for better understanding the heat transfer processes from the roof to the internal environment of the housing.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the impact of intra-urban atmospheric conditions on circulatory and respiratory diseases in elder adults. METHODS: Cross-sectional study based on data from 33,212 hospital admissions in adults over 60 years in the city of Sao Paulo, southeastern Brazil, from 2003 to 2007. The association between atmospheric variables from Congonhas airport and bioclimatic index, Physiological Equivalent Temperature, was analyzed according to the district's socioenvironmental profile. Descriptive statistical analysis and regression models were used. RESULTS: There was an increase in hospital admissions due to circulatory diseases as average and lowest temperatures decreased. The likelihood of being admitted to the hospital increased by 12% with 1 degrees C decrease in the bioclimatic index and with 1 degrees C increase in the highest temperatures in the group with lower socioenvironmental conditions. The risk of admission due to respiratory diseases increased with inadequate air quality in districts with higher socioenvironmental conditions. CONCLUSIONS: The associations between morbidity and climate variables and the comfort index varied in different groups and diseases. Lower and higher temperatures increased the risk of hospital admission in the elderly. Districts with lower socioenvironmental conditions showed greater adverse health impacts.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pregnant sows confinement systems were created in order to maximize the productivity, however there are problems concerning the animal welfare. The aim of this research was to evaluate pregnant sows in outdoors and in confinement systems in relation to the thermal environment and physiological animal responses. The experiment was conducted in a commercial farm in Monte Mor city, Sao Paulo, Brazil. The physiological evaluation was performed by recording physiological variables, such as respiratory frequency and skin temperature. Furthermore, variables like dry bulb temperature, wet bulb temperature, and black globe temperature were also evaluated to characterize the ambient by means of enthalpy and black globe humidity index. In each treatment six animals were evaluated. The experimental design was completely randomized in a split-plot version whose averages were compared by the Tukey test. The findings of the experiment revealed higher values for all the bioclimatic variables in the confined treatment. Hence, the outdoor system provided better thermal conditioning for pigs, resulting in a lower heat stress.