965 resultados para test protocol


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The break point of the curve of blood lactate vs exercise load has been called anaerobic threshold (AT) and is considered to be an important indicator of endurance exercise capacity in human subjects. There are few studies of AT determination in animals. We describe a protocol for AT determination by the "lactate minimum test" in rats during swimming exercise. The test is based on the premise that during an incremental exercise test, and after a bout of maximal exercise, blood lactate decreases to a minimum and then increases again. This minimum value indicates the intensity of the AT. Adult male (90 days) Wistar rats adapted to swimming for 2 weeks were used. The initial state of lactic acidosis was obtained by making the animals jump into the water and swim while carrying a load equivalent to 50% of body weight for 6 min (30-s exercise interrupted by a 30-s rest). After a 9-min rest, blood was collected and the incremental swimming test was started. The test consisted of swimming while supporting loads of 4.5, 5.0, 5.5, 6.0 and 7.0% of body weight. Each exercise load lasted 5 min and was followed by a 30-s rest during which blood samples were taken. The blood lactate minimum was determined from a zero-gradient tangent to a spline function fitting the blood lactate vs workload curve. AT was estimated to be 4.95 ± 0.10% of body weight while interpolated blood lactate was 7.17 ± 0.16 mmol/l. These results suggest the application of AT determination in animal studies concerning metabolism during exercise.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Malignant hyperthermia (MH) is a pharmacogenetic disease triggered by volatile anesthetics and succinylcholine. Deaths due to MH have been reported in Brazil. The first Malignant Hyperthermia Diagnostic and Research Center in Latin America was inaugurated in 1993 at the Federal University of Rio de Janeiro, Brazil. The center followed the diagnostic protocols of the North America MH Group, in which the contractures of biopsies from the vastus lateralis muscle are analyzed after exposure to caffeine and halothane (CHCT). CHCT was performed in individuals who survived, their relatives and those with signs/symptoms somewhat related to MH susceptibility (MHS). Here, we report data from 194 patients collected over 16 years. The Southeast (N = 110) and South (N = 71) represented the majority of patients. Median age was 25 (4-70) years, with similar numbers of males (104) and females (90). MHS was found in 90 patients and 104 patients were normal. Abnormal responses to both caffeine and halothane were observed in 59 patients and to caffeine or halothane in 20 and 11 patients, respectively. The contracture of biopsies from MHS exposed to caffeine and halothane was 1.027 ± 0.075 g (N = 285) and 4.021 ± 0.255 g (N = 226), respectively. MHS was found in patients with either low or high blood creatine kinase and also, with a low score on the clinical grading scale. Thus, these parameters cannot be used with certainty to predict MHS. We conclude that the CHCT protocol described by the North America MH Group contributed to identification of MHS in suspected individuals at an MH center in Brazil with 100% sensitivity and 65.7% specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The 6-minute walk test (6MWT) is a simple field test that is widely used in clinical settings to assess functional exercise capacity. However, studies with healthy subjects are scarce. We hypothesized that the 6MWT might be useful to assess exercise capacity in healthy subjects. The purpose of this study was to evaluate 6MWT intensity in middle-aged and older adults, as well as to develop a simple equation to predict oxygen uptake ( V ˙ O 2 ) from the 6-min walk distance (6MWD). Eighty-six participants, 40 men and 46 women, 40-74 years of age and with a mean body mass index of 28±6 kg/m2, performed the 6MWT according to American Thoracic Society guidelines. Physiological responses were evaluated during the 6MWT using a K4b2 Cosmed telemetry gas analyzer. On a different occasion, the subjects performed ramp protocol cardiopulmonary exercise testing (CPET) on a treadmill. Peak V ˙ O 2 in the 6MWT corresponded to 78±13% of the peak V ˙ O 2 during CPET, and the maximum heart rate corresponded to 80±23% of that obtained in CPET. Peak V ˙ O 2 in CPET was adequately predicted by the 6MWD by a linear regression equation: V ˙ O 2 mL·min-1·kg-1 = -2.863 + (0.0563×6MWDm) (R2=0.76). The 6MWT represents a moderate-to-high intensity activity in middle-aged and older adults and proved to be useful for predicting cardiorespiratory fitness in the present study. Our results suggest that the 6MWT may also be useful in asymptomatic individuals, and its use in walk-based conditioning programs should be encouraged.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to analyze the agreement between measurements of unloaded oxygen uptake and peak oxygen uptake based on equations proposed by Wasserman and on real measurements directly obtained with the ergospirometry system. We performed an incremental cardiopulmonary exercise test (CPET), which was applied to two groups of sedentary male subjects: one apparently healthy group (HG, n=12) and the other had stable coronary artery disease (n=16). The mean age in the HG was 47±4 years and that in the coronary artery disease group (CG) was 57±8 years. Both groups performed CPET on a cycle ergometer with a ramp-type protocol at an intensity that was calculated according to the Wasserman equation. In the HG, there was no significant difference between measurements predicted by the formula and real measurements obtained in CPET in the unloaded condition. However, at peak effort, a significant difference was observed between oxygen uptake (V˙O2)peak(predicted)and V˙O2peak(real)(nonparametric Wilcoxon test). In the CG, there was a significant difference of 116.26 mL/min between the predicted values by the formula and the real values obtained in the unloaded condition. A significant difference in peak effort was found, where V˙O2peak(real)was 40% lower than V˙O2peak(predicted)(nonparametric Wilcoxon test). There was no agreement between the real and predicted measurements as analyzed by Lin’s coefficient or the Bland and Altman model. The Wasserman formula does not appear to be appropriate for prediction of functional capacity of volunteers. Therefore, this formula cannot precisely predict the increase in power in incremental CPET on a cycle ergometer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Validation ofan Ice Skating Protocol to Predict Aerobic Power in Hockey Players In assessing the physiological capacity of ice hockey players, researchers have often reported the outcomes from different anaerobic skate tests, and the general physical fitness of participants. However, with respect to measuring the aerobic power of ice hockey players, few studies have reported a sport-specific protocol, and currently there is a lack of cohort-specific information describing aerobic power based on evaluations using an on-ice protocol. The Faught Aerobic Skating Test (FAST) uses an on-ice continuous skating protocol to induce a physical stress on a participant's aerobic energy system. The FAST incorporates the principle of increasing workloads at measured time intervals during a continuous skating exercise. Regression analysis was used to determine the estimate of aerobic power within gender and age level. Data were collected on 532 hockey players, (males=384, females=148) ranging in age between 9 and 25 years. Participants completed a laboratory test to measure aerobic power using a modified Bruce protocol, and the on-ice FAST. Regression equations were developed for six male and female, age-specific cohorts separately. The most consistent predictors were weight and final stage completed on the FAST. These results support the application of the FAST to estimate aerobic power among hockey players with R^ values ranging from 0.174 to 0.396 and SEE ranging from 5.65 to 8.58 ml kg' min'' depending on the cohort. Thus we conclude that FAST to be an accurate predictor of aerobic power in age and gender-specific hockey playing cohorts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 2003, prostate cancer (PCa) is estimated to be the most commonly diagnosed cancer and third leading cause of cancer death in Canada. During PCa population screening, approximately 25% of patients with a normal digital rectal examination (DRE) and intermediate serum prostate specific antigen (PSA) level have PCa. Since all patients typically undergo biopsy, it is expected that approximately 75% of these procedures are unnecessary. The purpose of this study was to compare the degree of efficacy of clinical tests and algorithms in stage II screening for PCa while preventing unnecessary biopsies from occurring. The sample consisted of 201 consecutive men who were suspected of PCa based on the results of a DRE and serum PSA. These men were referred for venipuncture and transrectal ultrasound (TRUS). Clinical tests included TRUS, agespecific reference range PSA (Age-PSA), prostate specific antigen density (PSAD), and free-to-total prostate specific antigen ratio (%fPSA). Clinical results were evaluated individually and within algorithms. Cutoffs of 0.12 and 0.15 ng/ml/cc were employed for PSAD. Cutoffs that would provide a minimum sensitivity of 0.90 and 0.95, respectively were utilized for %fPSA. Statistical analysis included ROC curve analysis, calculated sensitivity (Sens), specificity (Spec), and positive likelihood ratio (LR), with corresponding confidence intervals (Cl). The %fPSA, at a 23% cutoff ({ Sens=0.92; CI, 0.06}, {Spec=0.4l; CI, 0.09}, {LR=1.56; CI, O.ll}), proved to be the most efficacious independent clinical test. The combination of PSAD (cutoff 0.15 ng/ml/cc) and %fPSA (cutoff 23%) ({Sens=0.93; CI, 0.06}, {Spec=0.38; CI, 0.08}, {LR=1.50; CI, 0.10}) was the most efficacious clinical algorithm. This study advocates the use of %fPSA at a cutoff of 23% when screening patients with an intermediate serum PSA and benign DRE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The human neuromuscular system is susceptible to changes within the thermal environment. Cold extrinsic temperatures can significantly reduce muscle and nervous system function and communication, which can have consequences for motor performance. A repeated measures design protocol exposed participants to a 12°C cold water immersion (CWI) up to the ankle, knee, and hip to determine the effect that reduced skin and muscle temperature had on balance and strength task execution. Although a linear reduction in the ability to perform balance tasks was seen from the control condition through to the hip CWI, results from the study indicated a significant reduction in dynamic balance (Star Excursion Balance Test reach distance) performance from only the hip CWI (P<0.05). This reduced performance could have been due to an increase in joint stiffness, increased agonist-antagonist co-contraction, and/or reduced isokinetic muscular strength. Reduced physical performance due to cold temperature could negatively impact outdoor recreational athletics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As the number of processors in distributed-memory multiprocessors grows, efficiently supporting a shared-memory programming model becomes difficult. We have designed the Protocol for Hierarchical Directories (PHD) to allow shared-memory support for systems containing massive numbers of processors. PHD eliminates bandwidth problems by using a scalable network, decreases hot-spots by not relying on a single point to distribute blocks, and uses a scalable amount of space for its directories. PHD provides a shared-memory model by synthesizing a global shared memory from the local memories of processors. PHD supports sequentially consistent read, write, and test- and-set operations. This thesis also introduces a method of describing locality for hierarchical protocols and employs this method in the derivation of an abstract model of the protocol behavior. An embedded model, based on the work of Johnson[ISCA19], describes the protocol behavior when mapped to a k-ary n-cube. The thesis uses these two models to study the average height in the hierarchy that operations reach, the longest path messages travel, the number of messages that operations generate, the inter-transaction issue time, and the protocol overhead for different locality parameters, degrees of multithreading, and machine sizes. We determine that multithreading is only useful for approximately two to four threads; any additional interleaving does not decrease the overall latency. For small machines and high locality applications, this limitation is due mainly to the length of the running threads. For large machines with medium to low locality, this limitation is due mainly to the protocol overhead being too large. Our study using the embedded model shows that in situations where the run length between references to shared memory is at least an order of magnitude longer than the time to process a single state transition in the protocol, applications exhibit good performance. If separate controllers for processing protocol requests are included, the protocol scales to 32k processor machines as long as the application exhibits hierarchical locality: at least 22% of the global references must be able to be satisfied locally; at most 35% of the global references are allowed to reach the top level of the hierarchy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introducción La mutación genética Val30Met de la proteína transtiretina (TTR) es causante de la polineuropatía amiloidótica familiar, comprometiendo en fases iniciales las fibras nerviosas pequeñas (mielinizadas Aδ y amielínicas tipo C), involucradas en funciones autonómicas, nocicepción, percepción térmica y sudoración. Los métodos neurofisiológicos convencionales, no logran detectar dichas anormalidades, retardando el inicio de tratamientos específicos para la enfermedad. Metodología El objetivo principal fue evaluar el test de cuantificación sensitiva (QST) como método de detección temprana de anormalidades de fibra pequeña, en individuos Val30Met, seguidos en el Hospital Universitario Santa María, Lisboa. Se clasificaron los pacientes en 3 grupos, según sintomatología y examen neurológico. Se analizaron los umbrales para percepción de frío, dolor con el calor y vibración en los grupos, en correlación con controles sanos. Resultados 18 registros de controles sanos y 33 de individuos con la mutación, divididos en asintomáticos (24,2%), sintomáticos con examen neurológico normal (42,4%) y sintomáticos con examen neurológico anormal (33,3%). No se encontraron diferencias entre los pacientes asintomáticos y los controles. Los umbrales para frío (p=0,042) y en el dolor intermedio con el calor (HP 5) (p=0,007) se encuentran elevados en individuos Val30Met sintomáticos con examen normal. En los pacientes sintomáticos con alteraciones al examen, también se presentaron alteraciones en el intervalo entre el inicio y el dolor intermedio con el calor (HP 5-0,5) (p=0,009). Discusión Los umbrales de frío y de percepción de dolor con el calor, permiten detectar anormalidades en personas con la mutación TTR Val30Met, sintomáticos, incluyendo aquellos sin cambios objetivos al examen neurológico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a series of experiments the toxicity of lead to worms in soil was determined following the draft OECD earthworm reproduction toxicity protocol except that lead was added as solid lead nitrate, carbonate and sulphide rather than as lead nitrate solution as would normally be the case. The compounds were added to the test soil to give lead concentrations of 625-12500 pg Pb g-1 of soil. Calculated toxicities of the lead decreased in the order nitrate > carbonate > sulphide, the same order as the decrease in the solubility of the metal compounds used. The 7-day LC50 (lethal concentration when 50% of the population is killed) for the nitrate was 5321 +/- 275 mug Pb g(-1) of soil and this did not change with time. The LC50 values for carbonate and sulphide could not be determined at the concentration ranges used. The only parameter sensitive enough to distinguish the toxicities of the three compounds was cocoon (egg) production. The EC50S for cocoon production (the concentration to produce a 50% reduction in cocoon production) were 993, 8604 and 10 246 mug Pb g(-1) of soil for lead nitrate, carbonate and sulphide, respectively. Standard toxicity tests need to take into account the form in which the contaminant is present in the soil to be of environmental relevance. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A score test is developed for binary clinical trial data, which incorporates patient non-compliance while respecting randomization. It is assumed in this paper that compliance is all-or-nothing, in the sense that a patient either accepts all of the treatment assigned as specified in the protocol, or none of it. Direct analytic comparisons of the adjusted test statistic for both the score test and the likelihood ratio test are made with the corresponding test statistics that adhere to the intention-to-treat principle. It is shown that no gain in power is possible over the intention-to-treat analysis, by adjusting for patient non-compliance. Sample size formulae are derived and simulation studies are used to demonstrate that the sample size approximation holds. Copyright © 2003 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blood clotting response (BCR) resistance tests are available for a number of anticoagulant rodenticides. However, during the development of these tests many of the test parameters have been changed, making meaningful comparisons between results difficult. It was recognised that a standard methodology was urgently required for future BCR resistance tests and, accordingly, this document presents a reappraisal of published tests, and proposes a standard protocol for future use (see Appendix). The protocol can be used to provide information on the incidence and degree of resistance in a particular rodent population; to provide a simple comparison of resistance factors between active ingredients, thus giving clear information about cross-resistance for any given strain; and to provide comparisons of susceptibility or resistance between different populations. The methodology has a sound statistical basis in being based on the ED50 response, and requires many fewer animals than the resistance tests in current use. Most importantly, tests can be used to give a clear indication of the likely practical impact of the resistance on field efficacy. The present study was commissioned and funded by the Rodenticide Resistance Action Committee (RRAC) of CropLife International.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: UK National Institute of Health and Clinical Excellence guidelines for obsessive compulsive disorder (OCD) specify recommendations for the treatment and management of OCD using a stepped care approach. Steps three to six of this model recommend treatment options for people with OCD that range from low-intensity guided self-help (GSH) to more intensive psychological and pharmacological interventions. Cognitive behavioural therapy (CBT), including exposure and response prevention, is the recommended psychological treatment. However, whilst there is some preliminary evidence that self-managed therapy packages for OCD can be effective, a more robust evidence base of their clinical and cost effectiveness and acceptability is required. Methods/Design: Our proposed study will test two different self-help treatments for OCD: 1) computerised CBT (cCBT) using OCFighter, an internet-delivered OCD treatment package; and 2) GSH using a book. Both treatments will be accompanied by email or telephone support from a mental health professional. We will evaluate the effectiveness, cost and patient and health professional acceptability of the treatments. Discussion: This study will provide more robust evidence of efficacy, cost effectiveness and acceptability of self-help treatments for OCD. If cCBT and/or GSH prove effective, it will provide additional, more accessible treatment options for people with OCD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.