983 resultados para stiffness
Resumo:
Superconducting journal bearings have been investigated for use in flywheel systems. We report on the zero-field cooled and field-cooled stiffness of these bearings. They are made up of radial magnet rings with alternating polarities, a pole pitch of 11 mm and a surface field of 0.1 T. Field-cooled stiffness of the journal bearings increased four times over the zero-field-cooled stiffness. © 2005 IEEE.
Resumo:
This paper proposes a simple method to include superstructure stiffness in foundation analyses. The method involves extracting a small "condensed structural matrix" from finite element models of the superstructure, which can then be incorporated into pile group or piled raft analyses using common approaches such as elastic continuum or load transfer methods. The matrix condensation method directly couples structural and geotechnical analyses, and eliminates the need for iterative analyses between structural and geotechnical engineers. Effectiveness of the approach is illustrated through analyses of several buildings designed with a typical floor plan but with varying heights. The parametric study illustrates that superstructure stiffness can have a significant influence on foundation settlement estimates, and the stiffening effects are dominated by the lower stories of the superstructure. The proposed method aims to bridge the gap between structural and geotechnical analyses. Also, being a computationally simple and accurate approach, it is applicable to parametric or optimization studies that would otherwise involve large amounts of analyses. © 2010 ASCE.
Resumo:
This study compared the mechanisms of adaptation to stable and unstable dynamics from the perspective of changes in joint mechanics. Subjects were instructed to make point to point movements in force fields generated by a robotic manipulandum which interacted with the arm in either a stable or an unstable manner. After subjects adjusted to the initial disturbing effects of the force fields they were able to produce normal straight movements to the target. In the case of the stable interaction, subjects modified the joint torques in order to appropriately compensate for the force field. No change in joint torque or endpoint force was required or observed in the case of the unstable interaction. After adaptation, the endpoint stiffness of the arm was measured by applying displacements to the hand in eight different directions midway through the movements. This was compared to the stiffness measured similarly during movements in a null force field. After adaptation, the endpoint stiffness under both the stable and unstable dynamics was modified relative to the null field. Adaptation to unstable dynamics was achieved by selective modification of endpoint stiffness in the direction of the instability. To investigate whether the change in endpoint stiffness could be accounted for by change in joint torque or endpoint force, we estimated the change in stiffness on each trial based on the change in joint torque relative to the null field. For stable dynamics the change in endpoint stiffness was accurately predicted. However, for unstable dynamics the change in endpoint stiffness could not be reproduced. In fact, the predicted endpoint stiffness was similar to that in the null force field. Thus, the change in endpoint stiffness seen after adaptation to stable dynamics was directly related to changes in net joint torque necessary to compensate for the dynamics in contrast to adaptation to unstable dynamics, where a selective change in endpoint stiffness occurred without any modification of net joint torque.
Resumo:
The goal of this work was to investigate stability in relation to the magnitude and direction of forces applied by the hand. The endpoint stiffness and joint stiffness of the arm were measured during a postural task in which subjects exerted up to 30% maximum voluntary force in each of four directions while controlling the position of the hand. All four coefficients of the joint stiffness matrix were found to vary linearly with both elbow and shoulder torque. This contrasts with the results of a previous study, which employed a force control task and concluded that the joint stiffness coefficients varied linearly with either shoulder or elbow torque but not both. Joint stiffness was transformed into endpoint stiffness to compare the effect on stability as endpoint force increased. When the joint stiffness coefficients were modeled as varying with the net torque at only one joint, as in the previous study, we found that hand position became unstable if endpoint force exceeded about 22 N in a specific direction. This did not occur when the joint stiffness coefficients were modeled as varying with the net torque at both joints, as in the present study. Rather, hand position became increasingly more stable as endpoint force increased for all directions of applied force. Our analysis suggests that co-contraction of biarticular muscles was primarily responsible for the increased stability. This clearly demonstrates how the central nervous system can selectively adapt the impedance of the arm in a specific direction to stabilize hand position when the force applied by the hand has a destabilizing effect in that direction.
Resumo:
It has been shown that during arm movement, humans selectively change the endpoint stiffness of their arm to compensate for the instability in an unstable environment. When the direction of the instability is rotated with respect to the direction of movement, it was found that humans modify the antisymmetric component of their endpoint stiffness. The antisymmetric component of stiffness arises due to reflex responses suggesting that the subjects may have tuned their reflex responses as part of the feedforward adaptive control. The goal of this study was to examine whether the CNS modulates the gain of the reflex response for selective tuning of endpoint impedance. Subjects performed reaching movements in three unstable force fields produced by a robotic manipulandum, each field differing only in the rotational component. After subjects had learned to compensate for the field, allowing them to make unperturbed movements to the target, the endpoint stiffness of the arm was estimated in the middle of the movements. At the same time electromyographic activity (EMG) of six arm muscles was recorded. Analysis of the EMG revealed differences across force fields in the reflex gain of these muscles consistent with stiffness changes. This study suggests that the CNS modulates the reflex gain as part of the adaptive feedforward command in which the endpoint impedance is selectively tuned to overcome environmental instability. © 2008 Springer-Verlag Berlin Heidelberg.
Resumo:
The technique presented in this paper enables a simple, accurate and unbiased measurement of hand stiffness during human arm movements. Using a computer-controlled mechanical interface, the hand is shifted relative to a prediction of the undisturbed trajectory. Stiffness is then computed as the restoring force divided by the position amplitude of the perturbation. A precise prediction algorithm insures the measurement quality. We used this technique to measure stiffness in free movements and after adaptation to a linear velocity dependent force field. The subjects compensated for the external force by co-contracting muscles selectively. The stiffness geometry changed with learning and stiffness tended to increase in the direction of the external force.
Resumo:
Loose saturated sandy soils may undergo liquefaction under cyclic loading, generating positive excess pore pressures due to their contractile nature and inability to dissipate pore pressures rapidly during earthquake loading. These liquefied soils have a near-zero effective stress state, and hence have very low strength and stiffness, causing severe damage to structures founded upon them. The duration for which this near-zero effective stress state persists is a function of the rate of reconsolidation of the liquefied soil, which in turn is a function of the permeability and stiffness of the soil at this very low effective stress. Existing literature based on observation of physical model tests suggests that the consolidation coefficient C v associated with this reconsolidation of liquefied sand is significantly lower than that of the same soil at moderate stress levels. In this paper, the results of a series of novel fluidisation tests in which permeability k and coefficient of consolidation C v were independently measured will be presented. These results allow calculation of the variation of stiffness E 0 and permeability k with effective stress. It is shown that while permeability increases markedly at very low effective stresses, the simultaneous drop in stiffness measured results in a decrease in consolidation coefficient and hence an increase in the duration for which the soil remains liquefied.
Resumo:
Bone is a complex material with a hierarchical multi-scale organization from the molecule to the organ scale. The genetic bone disease, osteogenesis imperfecta, is primarily caused by mutations in the collagen type I genes, resulting in bone fragility. Because the basis of the disease is molecular with ramifications at the whole bone level, it provides a platform for investigating the relationship between structure, composition, and mechanics throughout the hierarchy. Prior studies have individually shown that OI leads to: 1. increased bone mineralization, 2. decreased elastic modulus, and 3. smaller apatite crystal size. However, these have not been studied together and the mechanism for how mineral structure influences tissue mechanics has not been identified. This lack of understanding inhibits the development of more accurate models and therapies. To address this research gap, we used a mouse model of the disease (oim) to measure these outcomes together in order to propose an underlying mechanism for the changes in properties. Our main finding was that despite increased mineralization, oim bones have lower stiffness that may result from the poorly organized mineral matrix with significantly smaller, highly packed and disoriented apatite crystals. Using a composite framework, we interpret the lower oim bone matrix elasticity observed as the result of a change in the aspect ratio of apatite crystals and a disruption of the crystal connectivity.