917 resultados para rheopheresis, recurring sensorineral hearing loss, LDL-fibrinogen apheresis
Resumo:
This paper describes a study assessing the sound levels and noise exposures of a municipal water treatment plant to determine the level of employee noise exposure dosages and to make any necessary recommendations regarding reducing the risk of noise induced hearing loss in employees.
Resumo:
This paper examines the risks of occupational noise induced hearing loss in firefighters. OSHA and National Institute for Occupational Safety and Health (NIOSH) guidelines are described and noise data collected from the Blue Island (Illinois) Fire Department is analyzed.
Resumo:
The purpose of this study is to compare three hearing aid manufacturers' recommended "First Fit" to the generic recommended fittings by DSL i/o and NAL-NL1 for a 12 month old child with varying degrees of sensorineural hearing loss.
Resumo:
An electromagnetic articulograph (EMA) system was used to provide a participant with congenital hearing loss visual biofeedback information on speech production. Five normally hearing listeners reported a change in their perception of the speech sound /æ/ in the various conditions of the study.
Resumo:
Siblings play a vital role in the health of a family as they adjust to having a child who is deaf or hard-of-hearing. In this project, a series of workshops has been designed for the siblings of children with a hearing loss to help better understand hearing loss and foster healthy sibling relationships.
Resumo:
The ability for individuals with hearing loss to accurately recognize correct versus incorrect verbal responses during traditional word recognition testing across four different listening conditions was assessed.
Resumo:
This paper examines the mainstreaming of hearing-impaired students in regular education classrooms. It evaluates the areas where teachers need more information regarding deafness, hearing loss and the teaching of hearing-impaired students. The paper also presents a list of resources to assist teachers in the education of hearing-impaired students in the mainstream classroom.
Resumo:
Objective: To determine the prevalence of occult hearing loss in elderly inpatients, to evaluate feasibility of opportunistic hearing screening and to determine subsequent provision of hearing aids. Materials and methods: Subjects (>65 years) were recruited from five elderly care wards. Hearing loss was detected by a ward-based hearing screen comprising patient-reported assessment of hearing disability and a whisper test. Subjects failing the whisper test or reporting hearing difficulties were offered formal audiological assessment. Results: Screening was performed on 51 patients aged between 70 and 95 years. Of the patients, 21 (41%) reported hearing loss and 16 (31%) failed the whisper test. A total of 37 patients (73%) were referred for audiological assessment with 17 (33%) found to have aidable hearing loss and 11 were fitted with hearing aids (22%). Discussion: This study highlights the high prevalence of occult hearing loss in elderly inpatients. Easy two-step screening can accurately identify patients with undiagnosed deafness resulting in significant proportions receiving hearing aids.
Resumo:
Little is known about the way speech in noise is processed along the auditory pathway. The purpose of this study was to evaluate the relation between listening in noise using the R-Space system and the neurophysiologic response of the speech-evoked auditory brainstem when recorded in quiet and noise in adult participants with mild to moderate hearing loss and normal hearing.
Resumo:
The primary goal of this study is to examine the ability of pediatric hearing-aid listeners, with mild to moderately-severe hearing loss, to perceive emotion and to discriminate talkers. These listeners’ performance is compared to that of similarly-aged listeners with normal hearing and who use cochlear implants.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJETIVO:Relatar o caso de um lactente com citomegalovírus congênito e disacusia neurossensorial progressiva, analisado por três métodos de avaliação auditiva.DESCRIÇÃO DO CASO:Na primeira avaliação auditiva, aos quatro meses de idade, o lactente apresentou ausência de Emissões Otoacústicas (EOA) e Potencial Evocado Auditivo de Tronco Encefálico (PEATE) dentro dos padrões de normalidade para a faixa etária, com limiar eletrofisiológico em 30dBnHL, bilateralmente. Com seis meses, apresentou ausência de PEATE bilateral em 100dBnHL. A avaliação comportamental da audição mostrou-se prejudicada devido ao atraso no desenvolvimento neuropsicomotor. Aos oito meses, foi submetido ao exame de Resposta Auditiva de Estado Estável (RAEE) e os limiares encontrados foram 50, 70, ausente em 110 e em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à direita, e 70, 90, 90 e ausente em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à esquerda.COMENTÁRIOS:Na primeira avaliação, o lactente apresentou alteração auditiva no exame de EOA e PEATE normal, que passou a ser alterado aos seis meses de idade. A intensidade da perda auditiva só pôde ser identificada pelo exame de RAEE, permitindo estabelecer a melhor conduta na adaptação de aparelho de amplificação sonora individual. Ressalta-se a importância do acompanhamento audiológico para crianças com CMV congênito.
The importance of retesting the hearing screening as an indicator of the real early hearing disorder
Resumo:
Early diagnosis of hearing loss minimizes its impact on child development. We studied factors that influence the effectiveness of screening programs. To investigate the relationship between gender, weight at birth, gestational age, risk factors for hearing loss, venue for newborn hearing screening and pass and fail results in the retest. Prospective cohort study was carried out in a tertiary referral hospital. The screening was performed in 565 newborns through transient evoked otoacoustic emissions in three admission units before hospital discharge and retest in the outpatient clinic. Gender, weight at birth, gestational age, presence of risk indicators for hearing loss and venue for newborn hearing screening were considered. Full-term infants comprised 86% of the cases, preterm 14%, and risk factors for hearing loss were identified in 11%. Considering the 165 newborns retested, only the venue for screening, Intermediate Care Unit, was related to fail result in the retest. Gender, weight at birth, gestational age and presence of risk factors for hearing loss were not related to pass and/or fail results in the retest. The screening performed in intermediate care units increases the chance of continued fail result in the Transient Otoacoustic Evoked Emissions test.
Resumo:
Presbycusis is a common disorder in the elderly, which causes hearing loss and may contribute to the development of some psychiatric disorders, leading to isolation clue to communication difficulties in the social environment. Objective: To identify through the WHOQOL (World Health Organization Quality of Life Questionnaire), the quality of life of hearing impaired individuals before and after hearing aid fittings. Method: We had 30 individuals with hearing loss, all over 60 years of age - patients from a Speech Therapy Clinic. The patients answered the WHOQOL questions without the use of hearing aids; and after the effective use of a sound amplification device for a period of three months they answered it again. The WHOQOL - Bref consists of 26 questions, two general quality-of-life questions and 24 associated with four aspects: physical, psychological, environmental and social relations. Results: There was a significant improvement in quality of life in general, as far as leisure activities were concerned, there were no major changes regarding the frequency of negative feelings; even after the hearing aid fitting, the patients continue to have such feelings. Conclusion: The use of hearing aids favored the overall quality of life of the individuals evaluated.
Resumo:
Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.