314 resultados para renovation
Resumo:
Intense tectonic renovation has occurred in the eastern continent of china since Mesozoic, as evidenced by the high heat flow, widespread magma extrusion and volcanic activities, and development of large sedimentary basins. To explain the cause and mechanism for the tectonic process in this period, some researchers have put forward various models, such as mantle plume, subduction of the Pacific slab, Yangtze Block-North China Block collision, etc. Their seismological evidence, however, is still scarce..During the period from 2000 to 2003, large temporary seismic arrays were established in North China by the Institute of the Geology and Geophysics, Chinese Academy of Sciences. Total 129 portable seismic stations were linearly emplaced across the western and eastern boundaries of the Bohai Bay Basin, and accumulated a large amount of high-quality data. Moreover, abundant data were also collected at the capital digital seismic network established in the ninth five-year period of national economic and social development. These provide an unprecedented opportunity for us to study the deep structure and associated geodynamic mechanism of lithospheric processes in North China using seismological techniques.Seismology is a kind of observation-based science. The development of seismic observations greatly promotes the improvement of seismologic theory and methodology. At the beginning of this thesis, I review the history of seismic observation progress, and present some routine processing techniques used in the array seismology. I also introduce two popular seismic imaging methods (receiver function method and seismic tomography).Receiver function method has been widely used to study the crustal and upper mantle structures, and many relevant research results have been published. In this thesis I elaborate the theory of this method, including the basic concept of receiver functions and the methodology for data pre-processing, stacking and migration. I also address some problems often encountered in practical applications of receiver function imaging.By using the teleseismic data collected at the temporary seismic arrays in North China, in particular, the traveltime information of P-to-S conversion and multiple reverberations of the Moho discontinuity, I obtain the distributions of the crustal thickness and the poisson ratio at the northwest boundary area of the Bohai Bay Basin and discuss the geological implications of the results.Through detailed intestigations on the crustal structural feature around the middle part of the Tanlu fault, considerable disparity in poisson ratios is found in the western and eastern sides of the Tanlu fault. Moreover, an obvious Moho offset is coincidently observed at the same surface location. A reasonable density model for the Tanlu fault area is also derived by simulating the observed gravity variations. Both receiver function study and gravity anomaly modeling suggest that the crustal difference between the western and eastern sides of the Tanlu fault is mainly resulted from their different compositions.With common conversion point imaging of receiver functions, I estimate the depths of the upper and lower boundaries of the mantle transition zone, i.e., the 410 and 660 km discontinuities, beneath most part of the North China continent The thickness of the transition zone (TTZ) in the study area is calculated by subtracting the depth of .410 km discontinuity from that of the 660km discontinuity. The resultant TTZ is 10-15 km larger in the east than in the west of the study area. Phase transitions at the 410 km and the 660 km discontinuities are known to have different Clapeyron slopes. Therefore, the TTZ is sensitive to the temperature changes in the transition zone. Previous studies have shown that the TTZ would be smaller in the mantle plume areas and become larger when the remnants of subducted slabs are present The hypothesis of mantle plume cannot give a reasonable interpretation to the observed TTZ beneath North China, Instead, the receiver function imaging results favor a dynamic model that correlates the thermal structure of the mantle transition zone and associated upper mantle dynamics of North China to the Pacific plate subduction process.
Resumo:
Os mercados e os desafios para producao animal a pasto; Mercado; Eliminacao da pratica do extrativismo; Equacionamento da oferta de forragem de qualidade durante todo o ano; Integracao dos sistemas de producao de graos e carne.
Resumo:
Estetyka w archeologii. Antropomorfizacje w pradziejach i starożytności, eds. E. Bugaj, A. P. Kowalski, Poznań: Wydawnictwo Poznańskie.
Resumo:
The Duke University Medical Center Library and Archives is located in the heart of the Duke Medicine campus, surrounded by Duke Hospital, ambulatory clinics, and numerous research facilities. Its location is considered prime real estate, given its adjacency to patient care, research, and educational activities. In 2005, the Duke University Library Space Planning Committee had recommended creating a learning center in the library that would support a variety of educational activities. However, the health system needed to convert the library's top floor into office space to make way for expansion of the hospital and cancer center. The library had only five months to plan the storage and consolidation of its journal and book collections, while working with the facilities design office and architect on the replacement of key user spaces on the top floor. Library staff worked together to develop plans for storing, weeding, and consolidating the collections and provided input into renovation plans for users spaces on its mezzanine level. The library lost 15,238 square feet (29%) of its net assignable square footage and a total of 16,897 (30%) gross square feet. This included 50% of the total space allotted to collections and over 15% of user spaces. The top-floor space now houses offices for Duke Medicine oncology faculty and staff. By storing a large portion of its collection off-site, the library was able to remove more stacks on the remaining stack level and convert them to user spaces, a long-term goal for the library. Additional space on the mezzanine level had to be converted to replace lost study and conference room spaces. While this project did not match the recommended space plans for the library, it underscored the need for the library to think creatively about the future of its facility and to work toward a more cohesive master plan.
Resumo:
Being a member of the thriving ASEAN and successfully implementing economic renovation (Doi Moi) have drawn the world's attention on Vietnam around the turn of the millennium. Some even expected a much faster pace of transformation, and renewed economic, AND political, reforms in Vietnam, or Doi Moi II.However, in the recent transition turmoil the Vietnamese economy has experienced some significant setback, and the solution for getting the country out of the downward spiral of low productivity, waning purchasing power and increasing costs of doing business cannot be worked out without addressing those political economy issues that have shaped the modus operandi of the nation's economic system. This article discusses the post-Doi Moi political economy in Vietnam, from 1986 to 2016 – when the 12th Congress of the Communist Party of Vietnam takes place – and prospects of reviving reform momentum in subsequent years.
Resumo:
Analyses the Family Division decision in Q v Q on the competing claims of a father and son to beneficial ownership of a house in which the father sought to on a secret agreement entered into with his sons when transferring the property into their joint names, intended to subvert the inheritance tax rules on lifetime gifts by retaining the right to have the property transferred back to him, and the son relied on a later agreement with his brother to transfer the house into his sole name, in reliance on which he and his wife had acted to their detriment by paying for its upkeep and renovation.
Resumo:
Mesenchymal stem cells (MSCs) reside within the bone marrow cavity and serve as a reservoir for the continuous renovation of various mesenchymal tissues. Recent efforts suggest that MSCs modulate the immune reactions in vitro and escape the immune surveillance in vivo. We provide herein a discussion of the issues including the current research progress on the in vitro interactions of MSCs with multiple subsets of immune cells (dendritic cells, T cells, B cells and natural killer cells), in vivo transplantation outcomes, the possible underlying mechanisms, future research directions as well as potential clinical implications.
Resumo:
This work presents a review of applicable sewer rehabilitation options using trenchless technology in Malaysia. The typical problems faced in wastewater collection systems are analysed and factors that determine the selection method are outlined. This study also highlights the necessary steps to be taken prior to the rehabilitation work. The trenchless technology reviewed here comprises repair, renovation and replacement options. The cost-effectiveness of different rehabilitation methods was identified to assess the economic viability of various options in the Malaysian context. This study reveals that not all the trenchless technologies available in the market are suitable for use in Malaysia, mainly due to incompatibility of the rehabilitation materials used. Furthermore, as trenchless rehabilitation generally involves higher capital outlay than open-cut methods, the choice of rehabilitation method has to be made on a case-to-case basis.
Resumo:
Using conjoint choice experiments, we surveyed 473 Swiss homeowners about their preferences for energy efficiency home renovations.We find that homeowners are responsive to the upfront costs of the renovation projects, governmentoffered rebates, savings in energy expenses, time horizon over which such savings would be realized, and thermal comfort improvement. The implicit discount rate is low, ranging from 1.5 to 3%, depending on model specification. This is consistent with Hassett and Metcalf (1993) and Metcalf and Rosenthal (1995), and with the fact that our scenarios contain no uncertainty. Respondents who feel completely uncertain about future energy prices are more likely to select the status quo (no renovations) in any given choice task and weight the costs of the investments more heavily than the financial gains (subsidies and savings on the energy bills). Renovations are more likely when respondents believe that climate change considerations are important determinants of home renovations. Copyright © 2013 by the IAEE. All rights reserved.
Resumo:
Archaeological excavation has provided an alternative source of evidence for the development of the late medieval peasant house. It is argued that whilst there was a significant change in building techniques in the decades around 1200 with the adoption of ground-set timbers, the most important factor which led to the survival of houses was a fall in real wages during the thirteenth century. This encouraged peasants to repair existing buildings, rather than replace them with new ones. Alternative traditions of building are also investigated. Stone construction was adopted in a number of areas of England, but in spite of the durability of the material, few medieval peasant buildings of this type have survived in use because of the failure to use lime mortar. Decisions about whether to invest in a building’s renovation will depend on the capital initially expended upon it. This interpretation is considered against the data from the fifteenth century and found to conform satisfactorily. Its implications are considered for the period between 1200 and 1350. Data collected from archaeological excavations combined with the results of dendrochronology on a growing number of closely dated standing buildings suggest that there was a significant ‘cull’ of houses in the period after 1350 as new dwellings were constructed.
Resumo:
We examine the effect of energy efficiency incentives on household energy efficiency home improvements. Starting in February 2007, Italian homeowners have been able to avail themselves of tax credits on the purchase and installation costs of certain types of energy efficiency renovations. We examine two such renovations—door/window replacements and heating system replacements—using multi-year cross-section data from the Italian Consumer Expenditure Survey and focusing on a narrow period around the introduction of the tax credits. Our regressions control for dwelling and household characteristics and economy-wide factors likely to influence the replacement rates. The effects of the policy are different for the two types of renovations. With window replacements, the policy is generally associated with a 30 % or stronger increase in the renovation rates and number of renovations. In the simplest econometric models, the effect is not statistically significant, but the results get stronger when we allow for heterogeneous effects across the country. With heating system replacements, simpler models suggest that the tax credits policy had no effect whatsoever or that free riding was rampant, i.e., people are now accepting subsidies for replacements that they would have done anyway. Further examination suggests a strong degree of heterogeneity in the effects across warmer and colder parts of the country, and effects in the colder areas that are even more pronounced than those for window replacements. These results should, however, be interpreted with caution due to the low rates of renovations, which imply that the effects are estimated relatively imprecisely.
Resumo:
A aposta na sustentabilidade tem conduzido o mercado da construção a procurar novas soluções técnicas e novos materiais, que por serem mais eficientes, conseguem dar resposta aos requisitos cada vez mais exigentes deste sector. A aplicação dos conceitos de sustentabilidade não se pode restringir a novas construções, tendo que prever também as renovações e a reabilitação de edifícios antigos. Assim, novos materiais que sejam desenvolvidos, devem contemplar todas estas vertentes de utilização. Neste trabalho desenvolveram-se argamassas com novas funcionalidades, que contribuem para melhorar os níveis de sustentabilidade dos edifícios, através da incorporação de nanomateriais para armazenamento de calor latente e degradação de poluentes do ar interior. Estudou-se não só o impacto da incorporação destas nanopartículas no estado fresco e endurecido, mas também o seu desempenho do ponto de vista funcional quando integrados na estrutura da argamassa. É possível obter argamassas com capacidade para armazenar calor latente através da incorporação de um material de mudança de fase. Este material constituído por uma mistura de parafinas, consegue armazenar calor e libertálo posteriormente. As composições desenvolvidas podem ser aplicadas em novos projectos ou na reabilitação de edifícios contribuindo para reduzir o consumo energético, melhorando o conforto térmico no interior. Com a redução da factura energética obtém-se uma efectiva diminuição do impacto ambiental, energético e económico do edifício. Para além do armazenamento de calor latente, também se desenvolveram argamassas capazes de eliminar poluentes do ar interior e, simultaneamente, com capacidade de auto-limpeza. Utilizaram-se nanopartículas de dióxido de titânio como aditivo fotocatalítico, tendo-se analisado o efeito da introdução deste aditivo nas argamassas. As composições testadas demonstraram elevada capacidade fotocatalítica e de auto-limpeza, sem comprometer as suas propriedades no estado endurecido. Ao aplicar estas composições na camada de acabamento interior melhora-se a qualidade do ar no interior das habitações e reduz-se a necessidade de utilização de sistemas de ventilação. As argamassas funcionais contribuem para melhorar os níveis de sustentabilidade da construção, tendo impacto económico e ambiental em todo o ciclo de vida do edifício.
Resumo:
Dissertação para a obtenção do Grau de Mestre em Contabilidade e Finanças Orientador: Mestre Adalmiro Álvaro Malheiro de Castro Andrade Pereira
Resumo:
Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.
Resumo:
Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Vias de Comunicação e Transportes