917 resultados para reliability test system


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Online dynamic load modeling has become possible with the availability of Static Voltage Compensator (SVC) and Phasor Measurement Unit (PMU) devices. The power of the load response to the small random bounded voltage fluctuations caused from SVC can be measured by PMU for modelling purposes. The aim of this paper is to illustrate the capability of identifying an aggregated load model from high voltage substation level in the online environment. The induction motor is used as the main test subject since it contributes the majority of the dynamic loads. A test system representing simple electromechanical generator model serving dynamic loads through the transmission network is used to verify the proposed method. Also, dynamic load with multiple induction motors are modeled to achieve a better realistic load representation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to develop and trial a method to monitor the evolution of clinical reasoning in a PBL curriculum that is suitable for use in a large medical school. Termed Clinical Reasoning Problems (CRPs), it is based on the notion that clinical reasoning is dependent on the identification and correct interpretation of certain critical clinical features. Each problem consists of a clinical scenario comprising presentation, history and physical examination. Based on this information, subjects are asked to nominate the two most likely diagnoses and to list the clinical features that they considered in formulating their diagnoses, indicating whether these features supported or opposed the nominated diagnoses. Students at different levels of medical training completed a set of 10 CRPs as well as the Diagnostic Thinking Inventory, a self-reporting questionnaire designed to assess reasoning style. Responses were scored against those of a reference group of general practitioners. Results indicate that the CRPs are an easily administered, reliable and valid assessment of clinical reasoning, able to successfully monitor its development throughout medical training. Consequently, they can be employed to assess clinical reasoning skill in individual students and to evaluate the success of undergraduate medical schools in providing effective tuition in clinical reasoning.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A laminated composite plate model based on first order shear deformation theory is implemented using the finite element method.Matrix cracks are introduced into the finite element model by considering changes in the A, B and D matrices of composites. The effects of different boundary conditions, laminate types and ply angles on the behavior of composite plates with matrix cracks are studied.Finally, the effect of material property uncertainty, which is important for composite material on the composite plate, is investigated using Monte Carlo simulations. Probabilistic estimates of damage detection reliability in composite plates are made for static and dynamic measurements. It is found that the effect of uncertainty must be considered for accurate damage detection in composite structures. The estimates of variance obtained for observable system properties due to uncertainty can be used for developing more robust damage detection algorithms. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The ability of Static Var Compensators (SVCs) to rapidly and continuously control reactive power in response to changing system conditions can result in the improvement of system stability and also increase the power transfer in the transmission system. This paper concerns the application of strategically located SVCs to enhance the transient stability limits and the direct evaluation of the effect of these SVCs on transient stability using a Structure Preserving Energy Function (SPEF). The SVC control system can be modelled from the steady- state control characteristic to accurately simulate its effect on transient stability. Treating the SVC as a voltage-dependent reactive power load leads to the derivation of a path-independent SPEF for the SVC. Case studies on a 10-machine test system using multiple SVCs illustrate the effects of SVCs on transient stability and its accurate prediction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nanoindentation is applied to the two polymorphs of aspirin to examine and differentiate their interaction anisotropy and shear instability. Aspirin provides an excellent test system for the technique because: (i) polymorphs I and II exhibit structural similarity in two dimensions, thereby facilitating clear examination of the differences in mechanical response in relation to well-defined differences between the two crystal structures; (ii) single crystals of the metastable polymorph II have only recently become accessible; (iii) shear instability has been proposed for II. Different elastic moduli and hardness values determined for the two polymorphs are correlated with their crystal structures, and the interpretation is supported by measured thermal expansion coefficients. The stress-induced transformation of the metastable polymorph II to the stable polymorph I can be brought about rapidly by mechanical milling, and proceeds via a slip mechanism. This work establishes that nanoindentation provides ``signature'' responses for the two aspirin polymorphs, despite their very similar crystal structures. It also demonstrates the value of the technique to quantify stability relationships and phase transformations in molecular crystals, enabling a deeper understanding of polymorphism in the context of crystal engineering.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work is an attempt to study crack initiation in nuclear grade, 9Cr-1Mo ferritic steel using AE as an online NDE tool. Laboratory experiments were conducted on 5 heat treated Compact Tension (CT) specimens made out of nuclear grade 9Cr-1Mo ferritic steel by subjecting them to cyclic tensile load. The CT Specimens were of 12.5 mm thickness. The Acoustic emission test system was setup to acquire the data continuously during the test by mounting AE sensor on one of the surfaces of the specimen. This was done to characterize AE data pertaining to crack initiation and then discriminate the samples in terms of their heat treatment processes based on AE data. The AE signatures at crack initiation could conclusively bring to fore the heat treatment distinction on a sample to sample basis in a qualitative sense.Thus, the results obtained through these investigations establish a step forward in utilizing AE technique as an on-line measurement tool for accurate detection and understanding of crack initiation and its profile in 9Cr-1Mo nuclear grade steel subjected to different processes of heat treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper addresses the problem of curtailing the number of control actions using fuzzy expert approach for voltage/reactive power dispatch. It presents an approach using fuzzy set theory for reactive power control with the purpose of improving the voltage profile of a power system. To minimize the voltage deviations from pre-desired values of all the load buses, using the sensitivities with respect to reactive power control variables form the basis of the proposed Fuzzy Logic Control (FLC). Control variables considered are switchable VAR compensators, On Load Tap Changing (OLTC) transformers and generator excitations. Voltage deviations and controlling variables are translated into fuzzy set notations to formulate the relation between voltage deviations and controlling ability of controlling devices. The developed fuzzy system is tested on a few simulated practical Indian power systems and modified IEEE-30 bus system. The performance of the fuzzy system is compared with conventional optimization technique and results obtained are encouraging. Results obtained for a modified IEEE-30 bus test system and a 205-node equivalent EHV system a part of Indian southern grid are presented for illustration purposes. The proposed fuzzy-expert technique is found suitable for on-line applications in energy control centre as the solution is obtained fast with significant speedups with few number of controllers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Effective network overload alleviation is very much essential in order to maintain security and integrity from the operational viewpoint of deregulated power systems. This paper aims at developing a methodology to reschedule the active power generation from the sources in order to manage the network congestion under normal/contingency conditions. An effective method has been proposed using fuzzy rule based inference system. Using virtual flows concept, which provides partial contributions/counter flows in the network elements is used as a basis in the proposed method to manage network congestions to the possible extent. The proposed method is illustrated on a sample 6 bus test system and on modified IEEE 39 bus system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Wind power, as an alternative to fossil fuels, is plentiful, renewable, widely distributed, clean, produces no greenhouse gas emissions during operation, and uses little land. In operation, the overall cost per unit of energy produced is similar to the cost for new coal and natural gas installations. However, the stochastic behaviour of wind speeds leads to significant disharmony between wind energy production and electricity demand. Wind generation suffers from an intermittent characteristics due to the own diurnal and seasonal patterns of the wind behaviour. Both reactive power and voltage control are important under varying operating conditions of wind farm. To optimize reactive power flow and to keep voltages in limit, an optimization method is proposed in this paper. The objective proposed is minimization of the voltage deviations of the load buses (Vdesired). The approach considers the reactive power limits of wind generators and co-ordinates the transformer taps. This algorithm has been tested under practically varying conditions simulated on a test system. The results are obtained on a system of 50-bus real life equivalent power network. The result shows the efficiency of the proposed method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: The present study was conducted to overcome the disadvantages associated with the poor water solubility and low bioavailability of curcumin by synthesizing nanotized curcumin and demonstrating its efficacy in treating malaria. Materials and methods: Nanotized curcumin was prepared by a modified emulsion-diffusion-evaporation method and was characterized by means of transmission electron microscopy, atomic force microscopy, dynamic light scattering, Zetasizer, Fourier transform infrared spectroscopy, and differential thermal analysis. The novelty of the prepared nanoformulation lies in the fact that it was devoid of any polymeric matrices used in conventional carriers. The antimalarial efficacy of the prepared nanotized curcumin was then checked both in vitro and in vivo. Results: The nanopreparation was found to be non-toxic and had a particle size distribution of 20-50 nm along with improved aqueous dispersibility and an entrapment efficiency of 45%. Nanotized curcumin (half maximal inhibitory concentration IC50]: 0.5 mu M) was also found to be ten-fold more effective for growth inhibition of Plasmodium falciparum in vitro as compared to its native counterpart (IC50: 5 mu M). Oral bioavailability of nanotized curcumin was found to be superior to that of its native counterpart. Moreover, when Plasmodium berghei-infected mice were orally treated with nanotized curcumin, it prolonged their survival by more than 2 months with complete clearance of parasites in comparison to the untreated animals, which survived for 8 days only. Conclusion: Nanotized curcumin holds a considerable promise in therapeutics as demonstrated here for treating malaria as a test system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Estimation of the dissociation constant, or pK(a), of weak acids continues to be a central goal in theoretical chemistry. Here we show that ab initio Car-Parrinello molecular dynamics simulations in conjunction with metadynamics calculations of the free energy profile of the dissociation reaction can provide reasonable estimates of the successive pK(a) values of polyprotic acids. We use the distance-dependent coordination number of the protons bound to the hydroxyl oxygen of the carboxylic group as the collective variable to explore the free energy profile of the dissociation process. Water molecules, sufficient to complete three hydration shells surrounding the acid molecule, were included explicitly in the computation procedure. Two distinct minima corresponding to the dissociated and un-dissociated states of the acid are observed and the difference in their free energy values provides the estimate for pK(a), the acid dissociation constant. We show that the method predicts the pK(a) value of benzoic acid in good agreement with experiment and then show using phthalic acid (benzene dicarboxylic acid) as a test system that both the first and second pK(a) values as well, as the subtle difference in their values for different isomers can be predicted in reasonable agreement with experimental data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The liquefaction of loess under dynamic loading is studied experimentally with a dynamic triaxial test system. The effects of over-consolidation ratio (OCR), saturation degree and the frequency of dynamic loading upon loess liquefaction are investigated. The development of pore pressure within loess samples is also discussed. Based on the experimental results, the empirical relationship between pore pressure ratio and loading cycle number ratio is established for normal consolidated saturated loess.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A test system was developed for measuring the pore pressure in porous media, and a new model was devised for the pore pressure testing in both saturated and unsaturated rock-soil. Laboratory experiments were carried out to determine the pore pressure during water level fluctuation. The variations of transient pore pressure vs. time at different locations of the simulated rock-soil system were acquired and processed, and meanwhile the deformation and failure of the model are observed. The experiment results show that whether the porous media are saturated or not, the transient pore pressure is mainly dependent on the water level fluctuation, and coupled with the variation of the stress field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A large number of chemical pollutants can be found in the marine environment. So it is necessary to obtain informations about the toxic effects of this contaminant mixtures in general and especially on single cell level. We used an organic extract of a marine sediment from the North Sea to investigate its cyto- and genotoxicity with an in vitro system, the comet assay or single cell gel electrophoresis (SCGE). The comet assay can be applied for estimating genotoxic effects of chemicals on single cell level. First results confirm the sensitivity of this assay and its applicability in assessing genotoxic load in environmental samples. A permant cell line, the EPC (Ephithelioma papulosum cyprini) was used for the experiments. It was possible to demonstrate the suitability of this in vitro test system for assessing genotoxic and cytotoxic effects of marine sediment extracts on EPC cells.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este estudo teve por objetivo investigar a relação trabalho / saúde em trabalhadores de cozinhas industriais, focalizando o aspecto socioeconômico e outras dimensões da vida social (estresse no trabalho e eventos de vida produtores de estresse), incluindo-se morbidade (obesidade, doenças crônicas e transtornos mentais comuns), condição laboral (incômodos ambientais e acidentes de trabalho) e comportamentos relacionados à saúde (consumo alimentar, tabagismo e álcool). Utilizando dados coletados nos nove Restaurantes Populares do Estado do Rio de Janeiro, apresentam-se três artigos. O primeiro descreve a população de estudo, considerando três grupos ocupacionais: Administrativos, Cozinheiros e Copeiros, e os Auxiliares de Serviços Gerais. O segundo artigo investiga a associação entre as características psicossociais e o impedimento laboral por motivos de saúde, considerando uma análise hierarquizada e, finalmente, o terceiro artigo discute a certificação da reprodutibilidade, na população de estudo, do questionário sueco da versão para o português do Demand-Control Questionnaire (DCQ), utilizado para avaliar estresse no ambiente de trabalho. Os homens representaram 62,7% do total de trabalhadores. A idade média dos funcionários foi de 35,1 anos, (DP=10,3). A renda familiar líquida foi de até dois salários mínimos para 60% dos trabalhadores. Obteve-se para o tempo de trabalho em cozinhas, uma média de 59,8 meses, tendo variado de um mínimo de 2 meses e máximo de 30 anos. A prevalência de doenças que tinham diagnóstico médico foi de 15,0% para Doença Osteomusculares Relacionadas ao Trabalho (DORT); 14,3% para Hipertensão Arterial Sistêmica; 12,7% para Gastrite; e, 2,1% para Diabete Mellitus tipo II. O acidente de trabalho corte foi relatado por 20,2% dos trabalhadores, seguido de contusão com 16,0%. A prevalência de acidentes de trabalho foi mais expressiva entre os ASG. A prevalência de impedimento laboral por motivos de saúde foi de 10,8%. Os modelos resultantes das análises multivariadas de associação entre impedimentos das atividades laborais e as variáveis que permaneceram no modelo final após o ajustes das variáveis indicaram que aqueles que referiram estado geral de saúde regular e ruim tiveram uma razão de prevalência de três para impedimento das atividades laborais comparados aos de muito bom e bom estado geral de saúde (RP: 3,59; IC:1,44-8,97). Os trabalhadores que exerciam suas atividades nos restaurante localizados na área 2 (Bangu, Central do Brasil, Maracanã e Niterói) apresentaram RP:2,38; IC:1,15-4,91) para ausências no trabalho quando comparados aos da área 1 (Barra Mansa, Campos, Itaboraí, Duque de Caxias e Nova Iguaçu). A confiabilidade da escala do DCQ, teste-reteste, produziu um Coeficiente de Correlação Intraclasse para as dimensões: demanda psicológica, controle do trabalho e apoio social no trabalho de 0,70, 0,68 e 0,80, respectivamente, sendo considerados bom. Este estudo reforça a importância dos aspectos psicossociais na ocorrência do impedimento por motivos de saúde e contribui para o conhecimento dessas relações. Sugere-se realizar estudos com desenho longitudinal, que permitam aprofundar o conhecimento sobre os determinantes psicossociais do trabalho e o absenteísmo.