574 resultados para refrigeração otimizada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The term refrigeration solar refers to any air conditioning system that uses solar energy as a primary energy source. The use of solar radiation for cooling purposes is divided according to their technological possibilities which are distinguished from one another as the way that energy is involved in the cycle, work or heat. The first case is related to vapor compression cycles, in which the work input is provided by the photovoltaic conversion of solar energy into electrical energy. In the second case, an absorption refrigeration cycle is used and the thermal energy collected from the solar radiation is provided at the generator of this cycle.. In this work a system with an absorption cycle using the pair BrLi-water, using solar energy as input is modeled. It is considered a simple refrigeration cycle whose the equations of mass and energy conservation in each component are developed in order to obtain an algebraic equation set and a simulation routine using the EES software. Although the simulation operates under certain specified thermal load it is possible to estimate the necessary areas of heat exchangers and solar collectors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to determine the most suitable type of heat exchanger to be applied to the water cooling the mold of a continuous casting process. Basically been studied four types of heat exchangers: shell and tube operating in counterflow, shell and tube operating in parallel flow, plate type and operating counterflow and plates operating in parallel flow. Initially is displayed design of heat exchangers for the conditions of the proposed application. With the heat exchangers dimensioned comparisons were made in order to set the heat exchanger more suitable for application. In the study, one comes to the conclusion that the plate type heat exchangers operating shows counterflow major advantage for this application

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a study of the absorption refrigeration system and the modeling and evaluation of two cycles using the binary solutions water-lithium bromide and ammonia-water for an equipment to be used in small size plants like residences. The study and evaluation aims the complete understanding of all parts of the system and the influence of each one of them as well as the spread of the knowledge to raise the use of this type of equipment in all sizes in order to decrease the energetic consumption of plants of all scales and making viable the alternative sources. The study is done in each element of the cycle separately and in some auxiliary equipments required in the operation such as the main power source, the solar collector. The software used for modeling, with emphasis on thermal part, was the EES (Engineering Equation Solver), that permitted the thermal balance calculus and acquisition of the used fluids properties. The results obtained for the equipment shows the system is more complex than the widely used in business, however, it can be viable and represents an alternative to increase the energetic efficiency

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because the routine use of frozen semen has some limitation that don´t permit its use in a large-scale, it is necessary to use the cooled semen. The equine cooled semen is normally used to enable that a genetic material with high quality be spread over long distances. When it reaches the temperature of refrigeration, the sperm metabolic activity decreases and the free radicals formation minimize. These ones cause irreversible damages to the sperm cells and, so, its lower formation is very advantageous. However, when we manipulate the semen using conservation techniques, like refrigeration, it is necessary to be aware about the sperm characteristics and fragilities, because, if performed erroneously, this technique can be harmful to the sperm function as well as to the time of sperm capacitation and acrosome reaction. It is necessary that cooling rate is slow and that the time and the storage temperature of the sperm obey the ranges that are already established. Moreover, we should make use of diluents and obtain the ideal sperm dilution, so that its use can be optimized. It´s also important to emphasize that to obtain good fertility rates, the semen, after processed (collected and diluted) must be conditioned in recipients specially developed for this purpose

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nine swines of the White Large race were used for study of the process of bony repair after osteotomy with rotating instruments of low and high-speed, with and without liquid refrigeration. The authors observed, through double blind histopathological analysis, that in every analyzed operative time, the bony repair was processed more appropriately when the osteotomies were accomplished with liquid refrigeration. In the final postoperative times, of fourteen and twenty-eight days, the best results of bony repair were observed in the osteotomy accomplished with drills of low rotation and with liquid refrigeration, while in the postoperative time of seven days, the results of the bony repair of osteotomy accomplished with drills of high rotation and with liquid refrigeration they were better. The authors consider, still, that the process of bony repair in swine display larger proximity in the histological pictures among the studied variables, when compared with other biological models. As most of the works told in the literature it refers the use of dogs, the authors consider that the present work guarantees your importance in the sense of looking for a closer model of the man.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The physical (pH) and microbiological (psychotrofi c microorganisms and lactic bacteria) characteristics of beef outside round (m. Biceps femoris) injected (15%) with brines free of polyphosphates containing and sodium lactate or sodium lactate and sodium diacetate and liquid bovine plasma (PLL and PLO) or dehydrated bovine plasma (PDL, PDO) were evaluated along with beef cuts injected with brines free from plasma, but containing polyphosphates and bacteriostatic agents (CL and CO) and non injected beef cuts (IN), comprising seven treatments of cooked and vacuum packaged beef steaks stored under refrigeration (6ºC) during 43 days. No differences in pH were detected among raw or cooked injected treatments, although IN showed lower pH value in raw beef cuts. The addition of liquid or dehydrated bovine plasma did not affect the microbial load after whole muscles pasteurization, but increased the bacterial counts in cooked beef steaks during refrigerated storage, comparing to treatments with no plasma addition (CL and CO). The storage temperature (6ºC), usually found during commercialization of meat increased the microorganisms growth rate affecting the microbiological quality, especially when plasma was added to the brine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Milk that is adequate for consumption must be of hygienic quality, nutritional value, and should maintain its organoleptic properties. Isolation of fecal and/or total coliforms from bovine milk is considered an indicator of hygiene and good management practices, and can be used as a quality indicator. This study aimed to isolate, identify, and assess the resistance profile of coliforms isolated from collective bulk tanks and individual milk tanks. A total of 89 milk samples were collected from collective bulk tanks and, from these, 21 Klebsiella spp., one E. coli, and 29 Enterobacter spp. were isolated, whereas 102 milk samples from individual tanks showed isolation of one Klebsiella spp. and seven Enterobacter spp. In collective bulk tanks, at least 47% of Klebsiella spp. and Enterobacter spp. were resistant to cephalexin and 30% to ampicillin. From these, at least 24% showed multidrug resistance. Among the microorganisms isolated from the individual tanks, 85% or more were resistant to ampicillin. The ESBL phenotype and the blaTEM gene were detected in strains of Klebsiella spp. isolated from both tanks. It was concluded that contamination of milk with resistant total coliforms, and especially the storage of raw milk from several small producers in the collective bulk tank increase the risk of contamination.