966 resultados para rectangular duct
Resumo:
A new technique is reported for micro-machining millimetre-wave rectangular waveguide components. S-parameter measurements on these structures show that they achieve lower loss than those produced using any other on-chip fabrication technique, have highly accurate dimensions, are physically robust, and are cheap and easy to manufacture.
Resumo:
A novel technique for micro-machining millimeter and submillimeter-wave rectangular waveguide components is reported. These are fabricated in two halves which simply snap together, utilizing locating pins and holes, and are physically robust, and cheap, and easy to manufacture. In addition, S-parameter measurements on these structures are reported for the first time and display lower loss than previously reported micro-machined rectangular waveguides.
Resumo:
In this work, a boundary element formulation to analyse plates reinforced by rectangular beams, with columns defined in the domain is proposed. The model is based on Kirchhoff hypothesis and the beams are not required to be displayed over the plate surface, therefore eccentricity effects are taken into account. The presented boundary element method formulation is derived by applying the reciprocity theorem to zoned plates, where beams are treated as thin sub-regions with larger rigidities. The integral representations derived for this complex structural element consider the bending and stretching effects of both structural elements working together. The standard equilibrium and compatibility conditions along interface are naturally imposed, being the bending tractions eliminated along interfaces. The in-plane tractions and the bending and in-plane displacements are approximated along the beam width, reducing the number of degrees of freedom. The columns are introduced into the formulation by considering domain points where tractions can be prescribed. Some examples are then shown to illustrate the accuracy of the formulation, comparing the obtained results with other numerical solutions.
Resumo:
Purpose: The aim of this study was to evaluate the clinical outcome of patients with mandibular angle fractures treated by intraoral access and a rectangular grid miniplate with 4 holes and stabilized with monocortical screws.Patients and Methods: This study included 45 patients with mandibular angle fractures from the Department of Oral and Maxillofacial Surgery São Paulo State University, Araraquara, Brazil, and from the Clinic of Oral and Maxillofacial Surgery at the University of Frankfurt, Germany. The 45 fractures of the mandibular angle were treated with a rectangular grid miniplate of a 2.0-mm system by an intraoral approach with monocortical screws. Clinical evaluations were postoperatively performed at 15 and 30 days and 3 and 6 months, and the complications encountered were recorded and treated.Results: The infection rate was 4.44% (2 patients), and in 1 patient it was necessary to replace hardware. This patient also had a fracture of the left mandibular body; 3 patients (6.66%) had minor occlusal changes that have been resolved with small occlusal adjustments. Before surgery, 15 patients (33.33%) presented with hypoesthesia of the inferior alveolar nerve; 4 (8.88%) had this change until the last clinical control, at 6 months.Conclusions: The rectangular grid miniplate used in this study was stable for the treatment of simple mandibular angle fractures through intraoral access, with low complication rates, easy handling, and easy adjustment, with a low cost. Concomitant mandibular fracture may increase the rate of complications. This plate should be indicated in fractures with sufficient interfragmentaty contact. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69:1436-1441, 2011
Resumo:
In this paper, we discuss the tunneling time of a quantum particle through a rectangular barrier. The reflection and transmission times associated with the wave packets representing the particle are discussed. By using an initial Gaussian momentum distribution, we carry out a comparative analysis of the stationary phases of the incident, reflected, and transmitted wave packets leading to the reflection and transmission times at, and Delta t(T), respectively. In the present treatment of this old and very known problem we take into account the deformations of the reflected and transmitted momentum distributions. These deformations produce a dependence of the reflection and transmission times on the location of the initial wave packet. In a parallel calculation, by numerically monitoring the time evolution of the system, we characterize a reflection and a transmission time. Such times agree with the ones obtained via the stationary phase method. [S1050-2947(98)07912-8].
Resumo:
The excretory duct in the silk gland of the sugarcane borer Diatraea saccharalis consists of two morphologically distinct regions, recognized by scanning and transmission electron microscopy. The thin posterior region, adjacent to the glandular region, presents a regular surface. Secretory vesicles containing either electron-dense or fibrillar cuticular-like materials are observed in their apical cytoplasm; the same cuticular materials were detected as extracellular deposits among the microvilli. The short anterior region, near the common duct, exhibits surface protrusions; there are no secretory vesicles in their apical cytoplasm. These results show that only the duct cells at the posterior region are involved in the secretion of the cuticular intima elements. Desmosome-like structures were visualized linking together adjacent microvillar membranes only in the cells of anterior duct region, with unknown function. The transition between the duct and the glandular region is abrupt; the cells of the glandular and posterior duct regions present large amounts of microtubules. Nerve fibers can be observed between the duct cells in their two regions, suggesting that control of silk secretion may occur in the excretory duct via neurotransmitter liberation. (C) 2002 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Extrahepatic obstruction in cat,can be caused by cholelithiasis, inspissated bile, pancreatic inflammation or fibrosis, duodenal inflammation, bile duct carcinoma or liver fluke infection (Amphimerus pseudofelineus e Platynosomurn concinum). A three-year-old, female neutered siames cat was present with a two-month history of progressive letargy, anorexia and emaciation. She had severe icterus of the mucous membranes, skin, and sclerae. A diagnosis of extrahepataic biliary obstruction was made based on the increased levels of conjugated bilirubin in the serum and the ultrasonography. Hepatic fluke eggs were not diagnosed in the feces because the fibrotic bile ducts were occluded and no eggs were shed into the intestine. Cholecystoduodenostomy was done to relieve posthepatic-biliary obstruction.