997 resultados para radiographic images


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mammography is a diagnostic imaging method in which interpretation depends on knowledge of radiological aspects as well as the clinical exam and pathophysiology of breast diseases. In this work a mammography phantom was developed to be used for training in the operation of mammographic x-ray equipment, image quality evaluation, self-examination and clinical examination of palpation. Polyurethane was used for the production of the phantoms for its physical and chemical properties and because it is one of the components normally used in prostheses. According to the range of flexibility of the polyurethane, it was possible to simulate breasts with higher or lower amount of adipose tissue. Pathologies such as areolar necrosis and tissue rejection due to surgery reconstruction after partial mastectomy were also simulated. Calcifications and nodules were simulated using the following materials: polyethylene, poly (methyl methacrylate), polyamide, polyurethane and poly (dimethyl silicone). Among these, polyethylene was able to simulate characteristics of calcification as well as breast nodules. The results from mammographic techniques used in this paper for the evaluation of the phantoms are in agreement with data found in the literature. The image analyses of four phantoms indicated significant similarities with the human skin texture and the female breast parenchyma. It was possible to detect in the radiographic images produced regions of high and low radiographic optical density, which are characteristic of breasts with regions of different amount of adipose tissue. The stiffnesses of breast phantoms were adjusted according to the formulation of the polyurethane which enabled the production of phantoms with distinct radiographic features and texture similar to human female breast parenchyma. Clinical palpation exam of the phantoms developed in this work indicated characteristics similar to human breast in skin texture, areolar region and parenchyma

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interactive documents for use with the World Wide Web have been developed for viewing multi-dimensional radiographic and visual images of human anatomy, derived from the Visible Human Project. Emphasis has been placed on user-controlled features and selections. The purpose was to develop an interface which was independent of host operating system and browser software which would allow viewing of information by multiple users. The interfaces were implemented using HyperText Markup Language (HTML) forms, C programming language and Perl scripting language. Images were pre-processed using ANALYZE and stored on a Web server in CompuServe GIF format. Viewing options were included in the document design, such as interactive thresholding and two-dimensional slice direction. The interface is an example of what may be achieved using the World Wide Web. Key applications envisaged for such software include education, research and accessing of information through internal databases and simultaneous sharing of images by remote computers by health personnel for diagnostic purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background It has been proposed that the feral horse foot is a benchmark model for foot health in horses. However, the foot health of feral horses has not been formally investigated. Objectives To investigate the foot health of Australian feral horses and determine if foot health is affected by environmental factors, such as substrate properties and distance travelled. Methods Twenty adult feral horses from five populations (n = 100) were investigated. Populations were selected on the basis of substrate hardness and the amount of travel typical for the population. Feet were radiographed and photographed, and digital images were surveyed by two experienced assessors blinded to each other's assessment and to the population origin. Lamellar samples from 15 feet from three populations were investigated histologically for evidence of laminitis. Results There was a total of 377 gross foot abnormalities identified in 100 left forefeet. There were no abnormalities detected in three of the feet surveyed. Each population had a comparable prevalence of foot abnormalities, although the type and severity of abnormality varied among populations. Of the three populations surveyed by histopathology, the prevalence of chronic laminitis ranged between 40% and 93%. Conclusions Foot health appeared to be affected by the environment inhabited by the horses. The observed chronic laminitis may be attributable to either nutritional or traumatic causes. Given the overwhelming evidence of suboptimal foot health, it may not be appropriate for the feral horse foot to be the benchmark model for equine foot health.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'un des principaux défis de l'interprétation radiographique réside dans la compréhension de l’anatomie radiographique, laquelle est intrinsèquement liée à la disposition tridimensionnelle des structures anatomiques et à l’impact du positionnement du tube radiogène vis-à-vis de ces structures lors de l'acquisition de l'image. Traditionnellement, des radiographies obtenues selon des projections standard sont employées pour enseigner l'anatomie radiographique en médecine vétérinaire. La tomodensitométrie − ou communément appelée CT (Computed Tomography) − partage plusieurs des caractéristiques de la radiographie en ce qui a trait à la génération des images. À l’aide d'un plug-in spécialement développé (ORS Visual ©), la matrice contenant les images CT est déformée pour reproduire les effets géométriques propres au positionnement du tube et du détecteur vis-à-vis du patient radiographié, tout particulièrement les effets de magnification et de distorsion. Afin d'évaluer le rendu des images simulées, différentes régions corporelles ont été imagées au CT chez deux chiens, un chat et un cheval, avant d'être radiographiées suivant des protocoles d'examens standards. Pour valider le potentiel éducatif des simulations, dix radiologistes certifiés ont comparé à l'aveugle neuf séries d'images radiographiques simulées aux séries radiographiques standard. Plusieurs critères ont été évalués, soient le grade de visualisation des marqueurs anatomiques, le réalisme et la qualité radiographique des images, le positionnement du patient et le potentiel éducatif de celles-ci pour différents niveaux de formation vétérinaire. Les résultats généraux indiquent que les images radiographiques simulées à partir de ce modèle sont suffisamment représentatives de la réalité pour être employées dans l’enseignement de l’anatomie radiographique en médecine vétérinaire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the construction of a homogeneous phantom to be used in simulating the scattering and absorption of X-rays by a standard patient chest and skull when irradiated laterally. This phantom consisted of Incite and aluminium plates with their thickness determined by a tomographic exploratory method applied to the anthropomorphic phantom. Using this phantom, an optimized radiographic technique was established for chest and skull of standard sized patient in lateral view. Images generated with this optimized technique demonstrated improved image quality and reduced radiation doses. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen's kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. on the other hand, radiographic examination and laser fluorescence were less efficient when used alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to conduct radiographic and histomorphometric analysis of bone healing in the calvaria of rabbits, using an autogenous graft associated with PRP obtained by 2 different methods. Thirty rabbits were divided into control and experimental groups. Lesions were produced in the calvaria and filled with autogenous graft ( control) or autogenous graft and PRP obtained by the Anitua or modified Sonnleitner methods. The animals were humanely killed 15 days after surgery and the calvarias were radiographed. The radiographs were digitized to assess the radiographic density. By histologic images of the lesion, the bone matrix was quantified. There were no significant differences in the radiographic density and the bone matrix area between the groups. The association of PRP with autogenous bone did not improve the healing process, irrespective of the method used early during healing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the influence of coronal filling and apical perforation on the induction of periapical inflammation. Methodology: Fifty-eight root canals in the teeth of dogs were divided into four groups. Groups I and II: root canals were exposed for 180 days; groups III and IV: root canals were exposed for 7 days and then the access cavity filled for 53 days. The root apices of groups I and III were perforated after the coronal opening, whilst those of groups II and IV remained intact. Standard radiographs were taken before and after the experimental periods. Digital images of the radiographs were created and then analysed by three examiners. After induction of periapical inflammation, the root canal contents were collected using paper points. Microbiologic evaluation of the type of microorganism was carried out by culture in different growth media. The radiographic and microbiologic data were statistically analysed using ANOVA at a 5% significance level. Results: There were a greater total number of microorganisms in groups I and II (P < 0.05). The number of anaerobes was greater than the number of aerobes (P < 0.05). The size of the periapical radiolucencies were not significantly different between the experimental groups. Conclusions: The different methods analysed induced similar areas of periapical radiolucency in dogs with predominantly anaerobic bacteria. However, the time required for induction was less when the method with coronal filling was used. © 2005 International Endodontic Journal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The radiopacity of esthetic restorative materials has been established as an important requirement, improving the radiographic diagnosis. The aim of this study was to evaluate the radiopacity of six restorative materials using a direct digital image system, comparing them to the dental tissues (enamel-dentin), expressed as equivalent thickness of aluminum (millimeters of aluminum). Five specimens of each material were made. Three 2-mm thick longitudinal sections were cut from an intact extracted permanent molar tooth (including enamel and dentin). An aluminum step wedge with 9 steps was used. The samples of different materials were placed on a phosphor plate together with a tooth section, aluminum step wedge and metal code letter, and were exposed using a dental x-ray unit. Five measurements of radiographic density were obtained from each image of each item assessed (restorative material, enamel, dentin, each step of the aluminum step wedge) and the mean of these values was calculated. Radiopacity values were subsequently calculated as equivalents of aluminum thickness. Analysis of variance (ANOVA) indicated significant differences in radiopacity values among the materials (P<0.0001). The radiopacity values of the restorative materials evaluated were, in decreasing order: TPH, F2000, Synergy, Prisma Flow, Degufill, Luxat. Only Luxat had significantly lower radiopacity values than dentin. One material (Degufill) had similar radiopacity values to enamel and four (TPH, F2000, Synergy and Prisma Flow) had significantly higher radiopacity values than enamel. In conclusion, to assess the adequacy of posterior composite restorations it is important that the restorative material to be used has enough radiopacity, in order to be easily distinguished from the tooth structure in the radiographic image. Knowledge on the radiopacity of different materials helps professionals to select the most suitable material, along with other properties such as biocompatibility, adhesion and esthetic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To assess the bone mineral density on conventional and digitized images, comparing whether different parameters of digitization and storage change these values. Methods: Twenty radiographs were taken from five partially dentulous dry mandibles with an aluminum 7-mm stepwedge placed on the superior edge of the film. After processing, the films were digitized with a resolution of 600 and 2,400 d.p.i. and saved as TIFF and JPEG files. On every conventional and digitized image, circular regions of interest were selected for densitometry and radiographic contrast analysis. Results: Pearson's correlation coefficient showed a significant and strong mean gray values association between digitized and conventional images, differing from radiographic contrast that did not show a significant association. ANOVA did not reveal a statistically significant difference in bone density and radiographic contrast among the four digitized image groups, but the conventional image contrast was significantly lower. Conclusions: Bone mineral density did not differ in both conventional and digitized images. The parameters of image compression and resolution, tested in this study, did not change the results of densitometry and digitization process increased the radiographic contrast.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the correlations between clinical-radiographical aspects and histomorphometric-molecular parameters of endosseous dental implant sites in humans. Material and methods: The study sample consisted of bone implant sites from the jawbones of 32 volunteers, which were classified according to two different systems: (1) based only on periapical and panoramic images (PP); (2) as proposed by Lekholm & Zarb (L&Z). Bone biopsies were removed using trephine during the first drilling for implant placement. Samples were stained with haematoxylin-eosin (HE), and histomorphometric analysis was performed to obtain the following parameters: trabecular thickness (Tb.Th), trabecular number, bone volume density (BV/TV), bone specific surface (BS/BV), bone surface density and trabecular separation (Tb.Sp). In addition, immunohistochemistry analysis was performed on bone tissue samples for the proteins, Receptor activator of nuclear factor kappa-B (RANK), RANK ligand (RANKL), osteoprotegerin (OPG) and Osteocalcin (OC). Also, the determination of the relative levels of gene expression was performed using Reverse transcription-real-time Polymerase Chain Reaction (RT-PCR). Results: PP and L&Z classification systems revealed a moderate correlation with BV/TV, BS/BV, Tb.Th and Tb.Sp. L&Z's system identified differences among bone types when BV/TV, BS/BV, Tb.Th and Tb.Sp were compared. A weak correlation between PP/L&Z classifications and the expression of bone metabolism regulators (RANK, RANKL, OPG e OC) was found. The analysis of mRNA expression showed no difference between the bone types evaluated. Conclusions: Our results suggest that PP and L&Z subjective bone-type classification systems are related to histomorphometric aspects. These data may contribute to the validation of these classifications. Bone remodelling regulatory molecules do not seem to influence morphological aspects of the jawbone © 2011 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An 8-month-old Lhasa Apso female dog was referred to the Veterinary Hospital, FMVZ, Unesp, Botucatu Campus, with suspected congenital renal disorder. Ultrasound images revealed higher renal echogenicity, loss of corticomedullary demarcation and diverticular mineralization on the right kidney. The mucosal lining of the stomach was hyperechoic and radiographic examination demonstrated mineralization of wall and folds, which is consistent with uremic gastropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of digitization parameters on periapical radiographic image quality, with regard to anatomic landmarks. Digitized images (n = 160) were obtained using a flatbed scanner with resolutions of 300, 600 and 2400 dpi. The radiographs of 2400 dpi were decreased to 300 and 600 dpi before storage. Digitizations were performed with and without black masking using 8-bit and 16-bit grayscale and saved in TIFF format. Four anatomic landmarks were classified by two observers (very good, good, moderate, regular, poor), in two random sessions. Intraobserver and interobserver agreements were evaluated by Kappa statistics. Inter and intraobserver agreements ranged according to the anatomic landmarks and resolution used. The results obtained demonstrated that the cement enamel junction was the anatomic landmark that presented the poorest concordance. The use of black masking provided better results in the digitized image. The use of a mask to cover radiographs during digitization is necessary. Therefore, the concordance ranged from regular to moderate for the intraobserver evaluation and concordance ranged from regular to poor for interobserver evaluation.