887 resultados para printed questionnaire
Resumo:
Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.
Resumo:
A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.
Resumo:
This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.
Resumo:
Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.
Resumo:
A novel surface molecularly-imprinted (MI) material to detect myoglobin (Myo) using gold screen printed electrodes (SPE) was developed. The sensitive detection was carry out by introducing a carboxylic polyvinyl chloride (PVC-COOH) layer on gold SPE surface. Myo was attached to the surface of gold SPE/PVC-COOH and the vacant spaces around it were filled by polymerizing acrylamide and N,N-methylenebisacrylamide (cross-linker). This polymerization was initiated by ammonium persulphate. After removing the template, the obtained material was able to rebind Myo and discriminate it among other interfering species. Various characterization techniques including electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) confirmed the surface modification. This sensor seemed a promising tool for screening Myo in point-of-care.
Resumo:
Several studies have shown that patients with congestive heart failure (CHF) have a compromised health-related quality of life (HRQL), and this, in recent years, has become a primary endpoint when considering the impact of treatment of chronic conditions such as CHF. OBJECTIVES: To evaluate the psychometric properties of the Portuguese version of a new specific instrument to measure HRQL in patients hospitalized for CHF: the Kansas City Cardiomyopathy Questionnaire (KCCQ). METHODS: The KCCQ was applied to a sample of 193 consecutive patients hospitalized for CHF. Of these, 105 repeated the assessment 3 months after admission, with no events during this period. Mean age was 64.4 +/- 12.4 years (21-88), and 72.5% were 72.5% male. CHF was of ischemic etiology in 4% of cases. RESULTS: This version of the KCCQ was subjected to statistical validation, with assessment of reliability and validity, similar to the American version. Reliability was assessed by the internal consistency of the domains and summary scores, which showed similar values of Cronbach alpha (0.50-0.94). Validity was assessed by convergence, sensitivity to differences between groups and sensitivity to changes in clinical condition. We evaluated the convergent validity of all domains related to functionality, through the relationship between them and a measure of functionality, the New York Heart Association (NYHA) classification. Significant correlations were found (p < 0.01) for this measure of functionality i patients with CHF. Analysis of variance between the physical limitation domain, the summary scores and NYHA class was performed and statistically significant differences were found (F = 23.4; F = 36.4; F = 37.4, p = 0.0001) in the ability to discriminate severity of clinical condition. A second evaluation was performed on 105 patients at the 3-month follow-up outpatient appointment, and significant changes were observed in the mean scores of the domains assessed between hospital admission and the clinic appointment (differences from 14.9 to 30.6 on a scale of 0-100), indicating that the domains assessed are sensitive to changes in clinical condition. The correlation between dimensions of quality of life in the KCCQ is moderate, suggesting that the dimensions are independent, supporting the multifactorial nature of HRQL and the suitability of this measure for its evaluation. CONCLUSION: The KCCQ is a valid instrument, sensitive to change and a specific measure of HRQL in a population with dilated cardiomyopathy and CHF.
Resumo:
The aim of this paper is to present the main Portuguese results from a multi-national study on reading format preferences and behaviors from undergraduate students from Polytechnic Institute of Porto (Portugal). For this purpose we apply an adaptation of the Academic Reading Questionnaire previously created by Mizrachi (2014). This survey instrument has 14 Likert-style statements regarding the format influence in the students reading behavior, including aspects such as ability to remember, feelings about access convenience, active engagement with the text by highlighting and annotating, and ability to review and concentrate on the text. The importance of the language and dimension of the text to determine the preference format is also inquired. Students are also asked about the electronic device they use to read digital documents. Finally, some demographic and academic data were gathered. The analysis of the results will be contextualized on a review of the literature concerning youngsters reading format preferences. The format (digital or print) in which a text is displayed and read can impact comprehension, which is an important information literacy skill. This is a quite relevant issue for class readings in academic context because it impacts learning. On the other hand, students preferences on reading formats will influence the use of library services. However, literature is not unanimous on this subject. Woody, Daniel and Baker (2010) concluded that the experience of reading is not the same in electronic or print context and that students prefer print books than e-books. This thesis is reinforced by Ji, Michaels and Waterman (2014) which report that among 101 undergraduates the large majority self-reported to read and learn more when they use printed format despite the fact that they prefer electronically supplied readings instead of those supplied in printed form. On the other side, Rockinson-Szapkiw, et al (2013) conducted a study were they demonstrate that e-textbook is as effective for learning as the traditional textbook and that students who choose e-textbook had significantly higher perceived learning than students who chose to use print textbooks.
Resumo:
A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.
Resumo:
RESUMO: Introdução: A asma brônquica é uma entidade frequente em idade pediátrica, apresentando uma grande heterogeneidade clínica e significativa morbilidade quando não controlada. A identificação de crianças sintomáticas pode atrasar ou até mesmo diminuir a ocorrência de algumas alterações estruturais. Reconhece-se a necessidade de questionários sobre sintomas respiratórios em língua portuguesa, devidamente validados, que tenham como população-alvo os grupos etários inferiores a 3 anos. Deste modo, será possível não só um conhecimento mais rigoroso da asma e da sibilância infantil mas também a uniformização de metodologias para o desenvolvimento de estratégias a nível nacional. Objetivos: Tradução com adaptação cultural para português e determinação da reprodutibilidade do Questionnaire on respiratory symptoms in preschool children de Strippoli e colaboradores. Material e métodos: A escolha do questionário obedeceu a vários critérios, entre os quais o grupo etário, o tipo e número de perguntas. O Questionnaire on respiratory symptoms in preschool children de Strippoli e colaboradores é um questionário de autopreenchimento, dirigido a crianças entre os 12 e os 24 meses de idade e destinado a estudos epidemiológicos ao nível da comunidade. Aborda aspetos referentes a sintomas respiratórios (sibilância, tosse crónica, sintomas das vias aéreas superiores), cuidados médicos, terapêutica, características ambientais, história familiar e situação social. Procedemos à sua tradução, com especial atenção para a adaptação do ponto de vista cultural e linguístico, utilizando o método da tradução / retroversão, amplamente utilizado e descrito na literatura internacional. Seguidamente determinámos a reprodutibilidade da versão final em língua portuguesa – Questionário de sintomas respiratórios em idade pré-escolar – utilizando o teste-reteste. Para tal, incluíram-se crianças entre os 12 e os 36 meses de idade recrutadas num Centro de Saúde e em creches de Lisboa. A distribuição dos questionários decorreu em duas fases: na primeira fase foram entregues pessoalmente nos locais de recrutamento e na segunda fase foram enviados por correio para os domicílios das crianças, respeitando-se um intervalo mínimo de 2 semanas entre ambos. Resultados: Na primeira fase foram distribuídos 180 questionários, com uma taxa de reposta de 41% (n=74). Na segunda fase enviaram-se para os respetivos domicílios 70 questionários,obtendo-se uma taxa de resposta de 66% (n=46). Para a análise de reprodutibilidade foram incluídos apenas os questionários preenchidos em ambos os momentos pelo mesmo indivíduo (mãe, pai ou representante legal) (n=41). A idade média das crianças foi, na primeira fase, de 22,5 meses e, na segunda fase, de 23,7 meses, com um predomínio do sexo feminino (F:M =1:0,6). A mediana do tempo decorrido entre os dois momentos de preenchimento dos questionários foi de 26 dias. Obtivemos valores de concordância globalmente bons a muito bons, à semelhança do sucedido no trabalho original. Conclusões: Procedemos à tradução e avaliação da reprodutibilidade do Questionnaire on respiratory symptoms in preschool children. Pretende-se que venha a ser uma ferramenta útil para estudos epidemiológicos e programas de rastreio na comunidade, contribuindo deste modo para uma otimização da abordagem da asma / sibilância infantil a nível nacional. -------------ABSTRACT: Background: Asthma is a very common feature in childhood, with important clinical heterogeneity and morbidity if not properly controlled. Identifying symptomatic children may delay or even reduce several structural changes. The development of questionnaires on respiratory symptoms in Portuguese for children under 3 years old will allow not only a more accurate knowledge of infantile asthma and recurrent wheezing but also the standardization of methodologies to develop nationwide strategies. Objectives: The aim of this study was to translate and adapt to the Portuguese culture and to determine the repeatability of the Questionnaire on respiratory symptoms in preschool children by Strippoli et al. Material and methods: The choice of the questionnaire took in consideration several criteria, among which the target age, the type and the number of questions. The Questionnaire on respiratory symptoms in preschool children by Strippoli et al is a parent-completed questionnaire for assessment of respiratory symptoms in 1 to 2-year-old children, developed for cross-sectional and longitudinal studies. It contains sections on respiratory symptoms (wheezing, chronic cough and upper airways symptoms), healthcare utilization, treatment, environmental exposure, family history and social situation. For the process of translation we used the method of translation and back-translation, with particular concern to cultural and linguistic adaptation. To assess the repeatability of the final Portuguese version - Questionário de sintomas respiratórios em idade pré-escolar - we used the test–retest analyses. The questionnaires were distributed to parents of children between 12 and 36 months old attending nurseries and a Primary Care Center of Lisbon. The distribution took place in two phases: the first questionnaires were delivered in person (phase one) and an identical questionnaire was posted to the families that participated in the first phase, 2 weeks after the first one was returned (phase two). Results: The response rates were 41% (180/74) in the first phase and 66% (70/46) in the second phase. For test–retest analyses, we included the 41 children with the same respondent (mother, father or legal representative) in both occasions. The median age of the children was 22,5 months at the first phase and 23,7 months at the second phase, with a predominance of girls (F:M = 1:0,6). The median time between the fillings of both questionnaires was 26 days. Globally, agreement values were good to excellent, similarly to the original work. Conclusion: In the present study we translated the Questionnaire on respiratory symptoms in preschool children and assessed its repeatability. Overall, we expect it to be a valuable tool for epidemiological studies and community-based screening programs, thus contributing to improve the management of infantile asthma / recurrent wheezing nationwide.
Resumo:
Introdução: A prática de atividade física tem vindo a ser incentivada por vários organismos nacionais e internacionais, visando a promoção de saúde. No entanto, não existe consenso em relação à influência e à intensidade ótima da atividade física durante a gravidez, tal facto pode dever-se à falta de instrumentos válidos que permitam a comparação entre os vários países do nível de atividade física das gestantes. Não foi identificado qualquer questionário válido que avaliasse a atividade física, durante a gravidez, para a população portuguesa. Objetivo: O objetivo deste estudo foi traduzir e adaptar o questionário PPAQ para a língua portuguesa e testar a fiabilidade e validade do mesmo. Métodos: A equivalência linguística foi obtida através da tradução e retrotradução e após a realização de um teste piloto a 6 mulheres grávidas. A fiabilidade foi obtida através do testereteste, com um intervalo de 7 dias, e analisada através do ICC, SEM e do método Bland Altman. A validade de critério foi testada, através dos resultados do PPAQ e do acelerómetro, pelo coeficiente de correlação de Pearson. Resultados: Os valores do ICC relativos à fiabilidade foram para o score total do PPAQ de 0,77, para as atividades sedentárias 0,87, para as atividade de baixa intensidade 0,76, para as atividades de intensidade moderada 0,76 e para as atividades de intensidade vigorosa 0,70. Na avaliação da validade obtivemos um valor de correlação de Pearson para atividade total de -0,030. Obtivemos correlação significante para as atividades de baixa intensidade (r=0,149; p=0,025), para as atividades de baixa intensidade em grávidas no 2º trimestre (r=0,256; p=0,010) e para as atividades de baixa intensidade e atividades vigorosas em mulheres no 3º trimestre gestacional (r=0,447; p=0,037 e r= 0,578; p=0,005, respetivamente). Conclusão: O PPAQ apresenta uma fiabilidade excelente e validade semelhante à versão original.
Resumo:
Dissertação para obtenção do Grau de Doutor em Química
Resumo:
Dissertação para obtenção do Grau de Mestre em Energias Renováveis – Conversão Eléctrica e Utilização Sustentável
Resumo:
Surveys of risky behavior relating to HIV/AIDS are generally made for groups at risk of infection, for which HIV/AIDS prevalence is usually expected to be higher than in the general population. Therefore, an educational homepage in Portuguese was created on the Internet to inform/ask internauts regarding knowledge and behavior. The internauts were classified as adolescents (13 to 25 years) and adults (>25 years). The number of STDs was reported as 1. 8 ± 2. 6 infections (range: 1 to 20 infections); 43% used condoms during sexual intercourse. Alcohol consumption was reported by 63% and illicit drug use by 32% (marijuana 24% and inhalants 15%). Among the adolescents, 31% did not classified alcohol as a drug. The adults more frequently reported homosexuality, anal intercourse and STDs, although the adolescents also presented high rates of risky behavior. These results show the need to reach out to internauts through better control strategies. Different types of strategies must be encouraged, in order to reach people that use this means of communication and entertainment.
Resumo:
This thesis reports the work performed in the optimization of deposition parameters of Multi – Walled Carbon Nanotubes (MWCNT) targeting the development of a Field Effect Transistors (FET) on paper substrates. The CNTs were dispersed in a water solution with sodium dodecyl sulphate (SDS) through ultrasonication, ultrasonic bath and a centrifugation to remove the supernatant and have a homogeneous solution. Several deposition tests were performed using different types of CNTs, dis-persants, papers substrates and deposition techniques, such as spray coating and inkjet printing. The characterization of CNTs was made by Scanning Electron Microscopy (SEM) and Hall Effect. The most suitable CNT coatings able to be used as semiconductor in FETs were deposited by spray coat-ing on a paper substrate with hydrophilic nanoporous surface (FS2) at 100 ºC, 4 bar, 10 cm height, 5 second of deposition time and 90 seconds of drying between steps (4 layers of CNTs were deposited). Planar electrolyte gated FETs were produced with these layers using gold-nickel gate, source and drain electrodes. Despite the small current modulation (Ion/Ioff ratio of 1.8) one of these devices have p-type conduction with a field effect mobility of 1.07 cm2/V.s.
Resumo:
In this work, cellulose-based electro and ionic conductive composites were developed for application in cellulose based printed electronics. Electroconductive inks were successfully formulated for screen-printing using carbon fibers (CFs) and multi-walled carbon nanotubes (MWCNTs) as conductive functional material and cellulose derivatives working as binder. The formulated inks were used to fabricate conductive flexible and disposable electrodes on paper-based substrates. Interesting results were obtained after 10 printing passes and drying at RT of the ink with 10 % wt. of pristine CFs and 3% wt. of carboxymethyl cellulose (CMC), exhibiting a resistivity of 1.03 Ωcm and a resolution of 400 μm. Also, a resistivity of 0.57 Ωcm was obtained for only one printing pass using an ink based on 0.5 % wt. MWCNTs and 3 % wt. CMC. It was also demonstrated that ionic conductive cellulose matrix hydrogel can be used in electrolyte-gated transistors (EGTs). The electrolytes revealed a double layer capacitance of 12.10 μFcm-2 and ionic conductivity of 3.56x10-7 Scm-1. EGTs with a planar configuration, using sputtered GIZO as semiconducting layer, reached an ON/OFF ratio of 3.47x105, a VON of 0.2 V and a charge carrier mobility of 2.32 cm2V-1s-1.