917 resultados para precision of distribution seeds
Morphological and anatomical studies of the seeds and seedlings of Eucalyptus pilularis and E. umbra
Resumo:
Morphological and anatomical aspects of seeds and seedlings of Eucalyptus pilularis Sm. and E. umbra R.T. Baker were studied in detail and fovnd to be similar, wlth the exception of sorne anatomical features of the testa and the average length of the fertile seeds, which is significantly different for the two species.
Resumo:
'Brasilia' is a cultivar of carrot with characteristics suiting cultivation under hot conditions but with problems in seed production, arising from the conflicting requirements of root and seed production. One solution is to select cultivars requiring vernalisation and then to use GA(3) to induce flowering where the climate prevents this. There is, however, little information on plant population, seed maturity and harvesting time on which to base such a procedure. Accordingly this research was carried out to study the physiological quality and production of the seeds in plant populations from 25,000 to 800,000 plants/ha, in the seed-to-seed method of cv. Brasilia in Anapolis, GO, Brazil. In each population, two harvest methods (from first and second orders of umbels, or selected harvest, and remaining orders, or total harvest) and two stages of maturity (brownish, or mature seeds, and yellowish, or immature ones) were also evaluated. Two trials were carried out, with and without gibberellic acid. Seed was evaluated for physical characters, germination, vigour, 1000-seed weight, water content, dry matter and productivity. Seed was produced in both experiments (with or without GA3 spraying). Mature seed showed germination at least 30% greater than immature, and seed from the selected harvest showed germination 16% greater than from the total harvest. In increasing plant population to 200,000 plants/ha, seed quality was not affected, but productivity increased.
Resumo:
This experiment was carried out at Plant Production Sector, Agronomical Science College-Botucatu, S.P., Brazil, in March, 2000. The aim of this assay was to determine the yield of essential oil of fennel (Foeniculum vulgare Miller) in different stages of development. Essential oils were prepared by hydrodistillation from the seeds using of Clevenger apparatus. The water utilized for the extraction of essential oil was sufficient to cover 100 g of seeds and the mixture was distilled for three hours. The volume of essential oil in the graduated side -arm of Clevenger apparatus was observed. There were no significative difference statistic was observed (Tukey 5%) in percentage (v/m) of oil content, based on dry weight of green seeds compared with dry weight of mature seeds, when they were harvested in two different stages of development. There was significative difference statistic between data obtained of humidity content of green seeds when these were compared with mature seeds. These results shows that others specifics studies about adaptation of fennel in tropical conditions are necessary, because the obtained data were different of data described on literature.
Resumo:
This paper presents a new methodology to evaluate in a predictive way the reliability of distribution systems, considering the impact of automatic recloser switches. The developed algorithm is based on state enumeration techniques with Markovian models and on the minimal cut set theory. Some computational aspects related with the implementation of the proposed algorithm in typical distribution networks are also discussed. The description of the proposed approach is carried out using a sample test system. The results obtained with a typical configuration of a Brazilian system (EDP Bandeirante Energia S.A.) are presented and discussed.
Resumo:
In this work a new method is proposed of separated estimation for the ARMA spectral model based on the modified Yule-Walker equations and on the least squares method. The proposal of the new method consists of performing an AR filtering in the random process generated obtaining a new random estimate, which will reestimate the ARMA model parameters, given a better spectrum estimate. Some numerical examples will be presented in order to ilustrate the performance of the method proposed, which is evaluated by the relative error and the average variation coefficient.
Resumo:
This article presents an automatic methodology for extraction of road seeds from high-resolution aerial images. The method is based on a set of four road objects and another set of connection rules among road objects. Each road object is a local representation of an approximately straight road fragment and its construction is based on a combination of polygons describing all relevant image edges, according to some rules embodying road knowledge. Each one of the road seeds is composed by a sequence of connected road objects, in which each sequence of this type can be geometrically structured as a chain of contiguous quadrilaterals. Experiments carried out with high-resolution aerial images showed that the proposed methodology is very promising in extracting road seeds. This article presents the fundamentals of the method and the experimental results, as well.
Resumo:
Low flexibility and reliability in the operation of radial distribution networks make those systems be constructed with extra equipment as sectionalising switches in order to reconfigure the network, so the operation quality of the network can be improved. Thus, sectionalising switches are used for fault isolation and for configuration management (reconfiguration). Moreover, distribution systems are being impacted by the increasing insertion of distributed generators. Hence, distributed generation became one of the relevant parameters in the evaluation of systems reconfiguration. Distributed generation may affect distribution networks operation in various ways, causing noticeable impacts depending on its location. Thus, the loss allocation problem becomes more important considering the possibility of open access to the distribution networks. In this work, a graphic simulator for distribution networks with reconfiguration and loss allocation functions, is presented. Reconfiguration problem is solved through a heuristic methodology, using a robust power flow algorithm based on the current summation backward-forward technique, considering distributed generation. Four different loss allocation methods (Zbus, Direct Loss Coefficient, Substitution and Marginal Loss Coefficient) are implemented and compared. Results for a 32-bus medium voltage distribution network, are presented and discussed.
Resumo:
Regulatory authorities in many countries, in order to maintain an acceptable balance between appropriate customer service qualities and costs, are introducing a performance-based regulation. These regulations impose penalties, and in some cases rewards, which introduce a component of financial risk to an electric power utility due to the uncertainty associated with preserving a specific level of system reliability. In Brazil, for instance, one of the reliability indices receiving special attention by the utilities is the Maximum Continuous Interruption Duration per customer (MCID). This paper describes a chronological Monte Carlo simulation approach to evaluate probability distributions of reliability indices, including the MCID, and the corresponding penalties. In order to get the desired efficiency, modern computational techniques are used for modeling (UML -Unified Modeling Language) as well as for programming (Object- Oriented Programming). Case studies on a simple distribution network and on real Brazilian distribution systems are presented and discussed. © Copyright KTH 2006.
Resumo:
Objective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.
Resumo:
In this paper a genetic algorithm based reconfiguration method is proposed to minimize the real power losses of distribution systems. The main innovation of this research work is that new types of crossover and mutation operators are proposed, such that the best possible results are obtained, with an acceptable computational effort. The crossover and mutation operators were developed so as to take advantage of the particular characteristics of distribution systems (as the radial topology). Simulation results indicate that the proposed method is very efficient, being able to find excellent configurations, with low computational effort, especially for larger systems. ©2007 IEEE.
Resumo:
In an evermore competitive environment, power distribution companies need to continuously monitor and improve the reliability indices of their systems. The network reconfiguration (NR) of a distribution system is a technique that well adapts to this new deregulated environment for it allows improvement of system reliability indices without the onus involved in procuring new equipment. This paper presents a reliability-based NR methodology that uses metaheuristic techniques to search for the optimal network configuration. Three metaheuristics, i.e. Tabu Search, Evolution Strategy, and Differential Evolution, are tested using a Brazilian distribution network and the results are discussed. © 2009 IEEE.
Resumo:
Purpose: The purpose of this paper is to characterize lychee seeds regarding their centesimal composition, and also to evaluate their antioxidant potential and fatty acid profile. Design/methodology/approach: To obtain the extract, dehydrated and grinded seeds were extracted with ethyl alcohol for 30 min, at a proportion of 1:3 of seeds:ethyl alcohol, under continuous agitation, at room temperature. Afterwards, the mixture was filtered and the supernatant subjected to a rotoevaporator at 40
Resumo:
This paper presents an efficient tabu search algorithm (TSA) to solve the problem of feeder reconfiguration of distribution systems. The main characteristics that make the proposed TSA particularly efficient are a) the way in which the neighborhood of the current solution was defined; b) the way in which the objective function value was estimated; and c) the reduction of the neighborhood using heuristic criteria. Four electrical systems, described in detail in the specialized literature, were used to test the proposed TSA. The result demonstrate that it is computationally very fast and finds the best solutions known in the specialized literature. © 2012 IEEE.
Resumo:
This study was conducted to evaluate the morphologic modifications in tissues of the fruit and seed of the crambe (Crambe abyssinica Hochst. Ex R.E. Fr.) after drying at different temperatures. Fruits with a water content of 0.38 kg water/kg dry matter were harvested and manually homogenized. Drying was accomplished at 35, 45, 60, 75, and 90°C and at 21,9,7,5, and 2% relative humidity, respectively. After drying, the structure of the pericarp and tegument of the seed were evaluated and the embryo was removed from the fruit/seed for morphological analysis (structural and ultrastructural and the histolocalization of reserve substances). Drying at different temperatures did not affect the cellular structure of the tissues composing the pericarp of the fruits, but it disorganized the structure of the seed tegument. The cells of the tegument and cotyledons presented a contraction in their volumes. The lowest contractions in the cellular volumes of both the tegument and cotyledons occurred after drying at 35 and 45°C. The cytoplasm of the cotyledon cells contains oil drops and the protein bodies contain protein granules and starch grains. There were no changes in the cellular walls of the embryos of the fruits dried at different temperatures; however, ungluing of the medium lamella occurred. This damage occurred with greater intensity after drying at temperatures above 60°C. The form of the oil drops in the cytoplasm of the cotyledon cells was altered after drying. At temperatures above 60°C, the drops broke up and coalesced. After drying at 45 and 60°C, the form of some protein bodies was altered, whereas at 75 and 90°C coalescence of the protein bodies occurred in some cells. It was concluded that the identified alterations can affect the physiologic quality of crambe seeds. © 2013 Copyright Taylor and Francis Group, LLC.
Resumo:
In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.