819 resultados para pattern matching protocols


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to evaluate Y-TZP surface after different airborne particle abrasion protocols. Seventy-six Y-TZP ceramic blocks (5×4×4) mm3 were sintered and polished. Specimens were randomly divided into 19 groups (n=4) according to control group and 3 factors: a) protocol duration (2 and 4 s); b) particle size (30 μm, alumina coated silica particle; 45 μm, alumina particle; and 145 μm, alumina particle) and; c) pressure (1.5, 2.5 and 4.5 bar). Airborne particle abrasion was performed following a strict protocol. For qualitative and quantitative results, topography surfaces were analyzed in a digital optical profilometer (Interference Microscopic), using different roughness parameters (Ra, Rq, Rz, X-crossing, Mr1, Mr2 and Sdr) and 3D images. Surface roughness also was analyzed following the primer and silane applications on Y-TZP surfaces. One-way ANOVA revealed that treatments (application period, particle size and pressure of particle blasting) provided significant difference for all roughness parameters. The Tukey test determined that the significant differences between groups were different among roughness parameters. In qualitative analysis, the bonding agent application reduced roughness, filing the valleys in the surface. The protocols performed in this study verified that application period, particle size and pressure influenced the topographic pattern and amplitude of roughness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this retrospective study was to compare, by means of lateral cephalograms, the facial growth pattern changes due to the treatment with and without extractions of four first premolars in dolichofacial individuals. METHODS: Groups 1 and 2 were constituted of 23 dolichofacial patients each, with Class II malocclusion, division 1 and initial age average of 12.36 and 12.29 years, respectively. Patients from Group 1 were treated without extractions and Group 2 was treated with extraction of the four first premolars, given that both used occipital headgear. Groups were compatibilized according to age, treatment period, gender and malocclusion severity. The t test was applied for intergroups comparison. RESULTS: Most variables (SN.PP, SN.Ocl and FMA) did not present statistically significant difference between groups. CONCLUSION: Although the treatment with extractions tend to reduce the mandibular plane angle (SN.GoGn) and the facial axis (NS.Gn), the analyzed treatment protocols did not affect in a clinically relevant way the facial growth pattern.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Ectopic calcification and mediacalcinosis can be promoted by corticosteroid use. Aim of the present investigation is to describe macrovascular disease features in patients with long-term corticosteroid therapy and symptomatic lower limb peripheral arterial occlusive disease (PAD). METHODS: A consecutive series of 2783 patients undergoing clinical and angiographic work-up of PAD were screened for long-term (>5 years) corticosteroid use (group A). Comparison was performed to a randomly selected age-, sex- and risk factor-matched PAD control cohort from the same series without corticosteroid use (group B). Patients with diabetes mellitus or severe renal failure were excluded. Arterial calcification was evaluated by qualitative assessment on radiographic images. Severity of atherosclerotic lesions was analysed from angiographic images using a semi-quantitative score (Bollinger score). RESULTS: In general, 12 patients (5 males, mean age 78.5 +/- 9.0 years) with 15 ischaemic limbs qualified to be enrolled in group A and were compared to 23 matching control patients (6 2 males, mean age 79.5 +/- 6 years) with 32 ischaemic limbs. Incompressibility of ankle arteries determined by measurement of the ankle-brachial index was seen in 12 limbs (80%) in group A compared to 3 limbs (9%) in group B (p = 0.0009). No significant difference was found comparing group A and B for segmental calcification, whereas comparison of the atherosclerotic burden using the angiographic severity score showed a significantly higher score at the infragenicular arterial level in group A (p = 0.001). CONCLUSION: Findings suggest that the long-term corticosteroid therapy is associated with a distally accentuated, calcifying peripheral atherosclerosis inducing arterial incompressibility. This occlusion pattern is comparable to patients with renal failure or diabetes. Further research is required to support our observations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This book will serve as a foundation for a variety of useful applications of graph theory to computer vision, pattern recognition, and related areas. It covers a representative set of novel graph-theoretic methods for complex computer vision and pattern recognition tasks. The first part of the book presents the application of graph theory to low-level processing of digital images such as a new method for partitioning a given image into a hierarchy of homogeneous areas using graph pyramids, or a study of the relationship between graph theory and digital topology. Part II presents graph-theoretic learning algorithms for high-level computer vision and pattern recognition applications, including a survey of graph based methodologies for pattern recognition and computer vision, a presentation of a series of computationally efficient algorithms for testing graph isomorphism and related graph matching tasks in pattern recognition and a new graph distance measure to be used for solving graph matching problems. Finally, Part III provides detailed descriptions of several applications of graph-based methods to real-world pattern recognition tasks. It includes a critical review of the main graph-based and structural methods for fingerprint classification, a new method to visualize time series of graphs, and potential applications in computer network monitoring and abnormal event detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To systematically review the available literature on the influence of dental implant placement and loading protocols on peri-implant innervation. MATERIAL AND METHODS The database MEDLINE, Cochrane, EMBASE, Web of Science, LILACS, OpenGrey and hand searching were used to identify the studies published up to July 2013, with a populations, exposures and outcomes (PEO) search strategy using MeSH keywords, focusing on the question: Is there, and if so, what is the effect of time between tooth extraction and implant placement or implant loading on neural fibre content in the peri-implant hard and soft tissues? RESULTS Of 683 titles retrieved based on the standardized search strategy, only 10 articles fulfilled the inclusion criteria, five evaluating the innervation of peri-implant epithelium, five elucidating the sensory function in peri-implant bone. Three included studies were considered having a methodology of medium quality and the rest were at low quality. All those papers reported a sensory innervation around osseointegrated implants, either in the bone-implant interface or peri-implant epithelium, which expressed a particular innervation pattern. Compared to unloaded implants or extraction sites without implantation, a significant higher density of nerve fibres around loaded dental implants was confirmed. CONCLUSIONS To date, the published literature describes peri-implant innervation with a distinct pattern in hard and soft tissues. Implant loading seems to increase the density of nerve fibres in peri-implant tissues, with insufficient evidence to distinguish between the innervation patterns following immediate and delayed implant placement and loading protocols. Variability in study design and loading protocols across the literature and a high risk of bias in the studies included may contribute to this inconsistency, revealing the need for more uniformity in reporting, randomized controlled trials, longer observation periods and standardization of protocols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interest in commercially farmed rabbit welfare has increased in recent years. As a result, new alternative housing systems have been developed, although they require evaluation in order to demonstrate their potential for improving welfare. The aim of this trial was to study the behavioural traits of rabbit does housed in 2 different types of cage (TC): conventional vs. alternative with an elevated platform, at different physiological stages (PS); lactation and gestation. Behavioural observations were carried out on 12 rabbit commercial does using continuous 24 h video recording. Independently of PS and TC, rabbit does spent most of their time on foot mats (on av. 57.7%). However, due to the use of platforms (on av. 23.0% of time), lactating does spent 36.6% less time on foot mats (P<0.001) and gestating does spent 27.0% less time on wire mesh (P<0.001) in alternative cages than in conventional cages. Alternative cages allowed for standing posture, but this behaviour was only observed in gestating does (on av. 4.6 times a day). Frequency of drinking was higher in conventional than in alternative cages (24.6 vs. 19.1 times a day; P<0.05). Gestating does housed in conventional cages reached the highest duration and frequency of interacting with neighbours (276 s/d and 4.6 times/d; P<0.05). The frequency of interacting with kits was lower in alternative than in conventional cages (2.4 vs. 8.6 times a day; P<0.01). Doe behaviour was influenced by the time of day, with less activity during the midday hours. During dark hours, rabbit does more frequently performed restless behaviour such as hyperactivity or nursing, matching the time at which rabbit does spent more time on the platform. The platform was frequently used by rabbit does, regardless of their physiological stage, and during late lactation phase, when mothers were not receptive to nursing, does housed in alternative cages used the platform as a mean to flee from kits trying to suckle. Use of the platform might lead to hygienic problems due to retained faeces on the platform and faeces and urine falling onto animals located in the lower part of the cage. The absence of stereotypies in rabbit does of this trial, suggested that animal welfare was not compromised by the type of housing (conventional or alternative cages).