985 resultados para partial discharge measurement
Resumo:
Surface treatment of polymers by discharge plasmas has increasingly found industrial applications due to its capability of modifying uniformly the surface without changing the material bulk properties. This work deals with surface modification of polyethylene terephthalate (PET) by a dielectric barrier discharge (DBD) at atmospheric pressure. The treatments were conducted in air, nitrogen or argon plasma. The polymer surface was characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The results show that the plasma treatment introduces oxygen-and nitrogen-related polar groups on the polymer surface and promotes the surface roughening. Both plasma-induced surface modifications contribute to the enhancement of the polymer wettability.
Resumo:
CONTEXTO: A síndrome HELLP é uma grave complicação da gestação caracterizada por hemólise, elevação das enzimas hepáticas e plaquetopenia. Algumas gestantes desenvolvem somente uma ou duas dessas características da síndrome HELLP. Esse quadro é denominado de síndrome HELLP parcial (SHP). OBJETIVO: O objetivo deste estudo foi avaliar as repercussões maternas e perinatais das mulheres que desenvolveram SHP e comparar os resultados com mulheres que tiveram hipertensão gestacional ou pré-eclâmpsia sem alterações dos exames laboratoriais para síndrome HELLP. TIPO DE ESTUDO: Observacional, retrospectivo e analítico. LOCAL: Maternidade do Hospital das Clínicas da Faculdade de Medicina de Botucatu, Universidade Estadual Paulista, Botucatu, São Paulo, Brasil. AMOSTRA: Foram selecionadas gestantes ou puérperas que tiveram elevação dos níveis pressóricos detectada pela primeira vez após a primeira metade da gestação com ou sem proteinúria entre janeiro/1990 a dezembro/1995. As mulheres foram divididas em dois grupos: Grupo SHP quando as mulheres com hipertensão arterial tinham pelo menos uma, mas não todas as alterações de exames que demonstravam hemólise, elevação das enzimas hepáticas ou plaquetopenia e Grupo Hipertensas pacientes com hipertensão sem alterações nos exames laboratoriais para síndrome HELLP. PRINCIPAIS VARIÁVEIS: Analisamos idade materna, raça, paridade, classificação da hipertensão, idade gestacional no diagnóstico da SHP, alterações nos exames laboratoriais para síndrome HELLP, tempo de permanência no hospital, complicações maternas, via de parto, incidência de prematuridade, restrição de crescimento intra-uterino, natimortos e neomortos. RESULTADOS: 318 mulheres foram selecionadas, das quais 41 (12,9%) tiveram SHP e 277 (87,1%) não desenvolveram alterações dos exames laboratoriais que compõem o diagnóstico da síndrome HELLP. A pré-eclâmpsia foi um tipo de hipertensão mais freqüente no grupo SHP que no grupo hipertensas. Não houve pacientes com hipertensão crônica isolada que desenvolveram SHP. A taxa de cesárea, eclâmpsia e de partos prematuros foi significativamente mais freqüente no grupo SHP que no grupo hipertensas. CONCLUSÃO: Observamos uma conduta agressiva nas pacientes com SHP, que resultou na interrupção imediata da gestação, com elevada taxa de cesárea e de recém-nascido pré-termo. Esta conduta deve ser revista para a redução desses índices.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A Streptomyces was isolated from poultry plant wastewater, showed high keratinolytic activity when cultured on feather meal medium. Optimum keratinolytic activity was observed at 40°C and pH 8.0. The enzyme also showed to be stable between 40 and 60°C. The keratinolytic activity was not inhibited by EDTA, DMSO and Tween 80. On the other hand, CaCl2, ZnCl2, and BaCl2 slightly inhibited the keratinolytic activity. The Streptomyces isolated might be useful in leather, keratin waste treatment, animal feeding industry, and also cosmetic industry. © 2008 Academic Journals.
Resumo:
The class of piezoelectric actuators considered in this paper consists of a multi-flexible structure actuated by two or more piezoceramic devices that must generate different output displacements and forces at different specified points of the domain and in different directions. The devices were modeled by finite element using the software ANSYS and the topology optimization method. The following XY actuators were build to achieve maximum displacement in the X and Y directions with a minimum crosstalk between them. The actuator prototypes are composed of an aluminum structure, manufactured by using a wire Electrical Discharge Machining, which are bonded to rectangular PZT5A piezoceramic blocks by using epoxy resin. Multi-actuator piezoelectric device displacements can be measured by using optical interferometry, since it allows dynamic measurements in the kHz range, which is of the order of the first resonance frequency of these piezomechanisms. A Michelson-type interferometer, with a He-Ne laser source, is used to measure the displacement amplitudes in nanometric range. A new optical phase demodulation technique is applied, based on the properties of the triangular waveform drive voltage applied to the XY piezoelectric nanopositioner. This is a low-phase-modulation-depth-like technique that allows the rapid interferometer auto-calibration. The measurements were performed at 100 Hz frequency, and revealed that the device is linear voltage range utilized in this work. The ratio between the generated and coupled output displacements and the drive voltages is equal to 10.97 nm/V and 1.76 nm/V, respectively, which corresponds to a 16% coupling rate. © 2010 IEEE.
Resumo:
Patient discharge from post-anesthetic recovery (PAR) depends, among other factors, on normothermia and the patient's score on the Aldrete-Kroulik index. The objective of this study was to verify the relationship between the Aldrete-Kroulik index and body temperature in patients. This study was performed at the University of Sao Paulo University Hospital. Convenience sampling was used, and the sample consisted of 60 patients of ages between 18 and 60 years who underwent general anesthesia. The patients' body temperature was obtained by tympanic measurement, and the Aldrete-Kroulik index was measured on admission and at discharge from post-anesthetic recovery. The data were processed using SPSS, considering a significance level of 5%, and the Spearman and Wilcoxon tests were applied. In conclusion, no significant correlation was found between the two parameters for discharge.
Resumo:
We propose a new method for fitting proportional hazards models with error-prone covariates. Regression coefficients are estimated by solving an estimating equation that is the average of the partial likelihood scores based on imputed true covariates. For the purpose of imputation, a linear spline model is assumed on the baseline hazard. We discuss consistency and asymptotic normality of the resulting estimators, and propose a stochastic approximation scheme to obtain the estimates. The algorithm is easy to implement, and reduces to the ordinary Cox partial likelihood approach when the measurement error has a degenerative distribution. Simulations indicate high efficiency and robustness. We consider the special case where error-prone replicates are available on the unobserved true covariates. As expected, increasing the number of replicate for the unobserved covariates increases efficiency and reduces bias. We illustrate the practical utility of the proposed method with an Eastern Cooperative Oncology Group clinical trial where a genetic marker, c-myc expression level, is subject to measurement error.
Resumo:
Intensive care unit (ICU) patients are ell known to be highly susceptible for nosocomial (i.e. hospital-acquired) infections due to their poor health and many invasive therapeutic treatments. The effects of acquiring such infections in ICU on mortality are however ill understood. Our goal is to quantify these effects using data from the National Surveillance Study of Nosocomial Infections in Intensive Care Units (Belgium). This is a challenging problem because of the presence of time-dependent confounders (such as exposure to mechanical ventilation)which lie on the causal path from infection to mortality. Standard statistical analyses may be severely misleading in such settings and have shown contradicting results. While inverse probability weighting for marginal structural models can be used to accommodate time-dependent confounders, inference for the effect of ?ICU acquired infections on mortality under such models is further complicated (a) by the fact that marginal structural models infer the effect of acquiring infection on a given, fixed day ?in ICU?, which is not well defined when ICU discharge comes prior to that day; (b) by informative censoring of the survival time due to hospital discharge; and (c) by the instability of the inverse weighting estimation procedure. We accommodate these problems by developing inference under a new class of marginal structural models which describe the hazard of death for patients if, possibly contrary to fact, they stayed in the ICU for at least a given number of days s and acquired infection or not on that day. Using these models we estimate that, if patients stayed in the ICU for at least s days, the effect of acquiring infection on day s would be to multiply the subsequent hazard of death by 2.74 (95 per cent conservative CI 1.48; 5.09).
Resumo:
This dissertation represents experimental and numerical investigations of combustion initiation trigged by electrical-discharge-induced plasma within lean and dilute methane air mixture. This research topic is of interest due to its potential to further promote the understanding and prediction of spark ignition quality in high efficiency gasoline engines, which operate with lean and dilute fuel-air mixture. It is specified in this dissertation that the plasma to flame transition is the key process during the spark ignition event, yet it is also the most complicated and least understood procedure. Therefore the investigation is focused on the overlapped periods when plasma and flame both exists in the system. Experimental study is divided into two parts. Experiments in Part I focuses on the flame kernel resulting from the electrical discharge. A number of external factors are found to affect the growth of the flame kernel, resulting in complex correlations between discharge and flame kernel. Heat loss from the flame kernel to code ambient is found to be a dominant factor that quenches the flame kernel. Another experimental focus is on the plasma channel. Electrical discharges into gases induce intense and highly transient plasma. Detailed observation of the size and contents of the discharge-induced plasma channel is performed. Given the complex correlation and the multi-discipline physical/chemical processes involved in the plasma-flame transition, the modeling principle is taken to reproduce detailed transitions numerically with minimum analytical assumptions. Detailed measurement obtained from experimental work facilitates the more accurate description of initial reaction conditions. The novel and unique spark source considering both energy and species deposition is defined in a justified manner, which is the key feature of this Ignition by Plasma (IBP) model. The results of numerical simulation are intuitive and the potential of numerical simulation to better resolve the complex spark ignition mechanism is presented. Meanwhile, imperfections of the IBP model and numerical simulation have been specified and will address future attentions.
Resumo:
DCE-MRI is an important technique in the study of small animal cancer models because its sensitivity to vascular changes opens the possibility of quantitative assessment of early therapeutic response. However, extraction of physiologically descriptive parameters from DCE-MRI data relies upon measurement of the vascular input function (VIF), which represents the contrast agent concentration time course in the blood plasma. This is difficult in small animal models due to artifacts associated with partial volume, inflow enhancement, and the limited temporal resolution achievable with MR imaging. In this work, the development of a suite of techniques for high temporal resolution, artifact resistant measurement of the VIF in mice is described. One obstacle in VIF measurement is inflow enhancement, which decreases the sensitivity of the MR signal to the presence of contrast agent. Because the traditional techniques used to suppress inflow enhancement degrade the achievable spatiotemporal resolution of the pulse sequence, improvements can be achieved by reducing the time required for the suppression. Thus, a novel RF pulse which provides spatial presaturation contemporaneously with the RF excitation was implemented and evaluated. This maximizes the achievable temporal resolution by removing the additional RF and gradient pulses typically required for suppression of inflow enhancement. A second challenge is achieving the temporal resolution required for accurate characterization of the VIF, which exceeds what can be achieved with conventional imaging techniques while maintaining adequate spatial resolution and tumor coverage. Thus, an anatomically constrained reconstruction strategy was developed that allows for sampling of the VIF at extremely high acceleration factors, permitting capture of the initial pass of the contrast agent in mice. Simulation, phantom, and in vivo validation of all components were performed. Finally, the two components were used to perform VIF measurement in the murine heart. An in vivo study of the VIF reproducibility was performed, and an improvement in the measured injection-to-injection variation was observed. This will lead to improvements in the reliability of quantitative DCE-MRI measurements and increase their sensitivity.
Resumo:
We present an independent calibration model for the determination of biogenic silica (BSi) in sediments, developed from analysis of synthetic sediment mixtures and application of Fourier transform infrared spectroscopy (FTIRS) and partial least squares regression (PLSR) modeling. In contrast to current FTIRS applications for quantifying BSi, this new calibration is independent from conventional wet-chemical techniques and their associated measurement uncertainties. This approach also removes the need for developing internal calibrations between the two methods for individual sediments records. For the independent calibration, we produced six series of different synthetic sediment mixtures using two purified diatom extracts, with one extract mixed with quartz sand, calcite, 60/40 quartz/calcite and two different natural sediments, and a second extract mixed with one of the natural sediments. A total of 306 samples—51 samples per series—yielded BSi contents ranging from 0 to 100 %. The resulting PLSR calibration model between the FTIR spectral information and the defined BSi concentration of the synthetic sediment mixtures exhibits a strong cross-validated correlation ( R2cv = 0.97) and a low root-mean square error of cross-validation (RMSECV = 4.7 %). Application of the independent calibration to natural lacustrine and marine sediments yields robust BSi reconstructions. At present, the synthetic mixtures do not include the variation in organic matter that occurs in natural samples, which may explain the somewhat lower prediction accuracy of the calibration model for organic-rich samples.
Resumo:
OBJECTIVE To determine neurologic outcome and factors influencing outcome after thoracolumbar partial lateral corpectomy (PLC) in dogs with intervertebral disc disease (IVDD) causing ventral spinal cord compression. STUDY DESIGN Retrospective case series. ANIMALS Dogs with IVDD (n = 72; 87 PLC). METHODS Dogs with IVDD between T9 and L5 were included if treated by at least 1 PLC. Exclusion criteria were: previous spinal surgery, combination of PLC with another surgical procedure. Neurologic outcome was assessed by: (1) modified Frankel score (MFS) based on neurologic examinations at 4 time points (before surgery, immediately after PLC, at discharge and 4 weeks after PLC); and (2) owner questionnaire. The association of the following factors with neurologic outcome was analyzed: age, body weight, duration of current neurologic dysfunction (acute, chronic), IVDD localization, breed (chondrodystrophic, nonchondrodystrophic), number of PLCs, degree of presurgical spinal cord compression and postsurgical decompression, slot depth, presurgical MFS. Presurgical spinal cord compression was determined by CT myelography (71 dogs) or MRI (1 dog), whereas postsurgical decompression and slot depth were determined on CT myelography (69 dogs). RESULTS MFS was improved in 18.7%, 31.7%, and 64.2% of dogs at the 3 postsurgical assessments, whereas it was unchanged in 62.6%, 52.8%, and 32.0% at corresponding time points. Based on owner questionnaire, 91.4% of dogs were ambulatory 6 months postsurgically with 74.5% having a normal gait. Most improvement in neurologic function developed within 6 months after surgery. Presurgical MFS was the only variable significantly associated with several neurologic outcome measurements (P < .01). CONCLUSIONS PLC is an option for decompression in ventrally compressing thoracolumbar IVDD. Prognosis is associated with presurgical neurologic condition.
Resumo:
Submitted in partial fulfillment of the requirements for a Certificate in Orthodontics, Dept. of Orthodontics, University of Connecticut Health Center, 1992