995 resultados para oral implants


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Immediate and early loading of dental implants can simplify treatment and increase overall patient satisfaction. The purpose of this 3-year prospective randomized-controlled multicenter study was to assess the differences in survival rates and bone level changes between immediately and early-loaded implants with a new chemically modified surface (SLActive). This investigation shows interim results obtained after 5 months. MATERIAL AND METHODS: Patients > or =18 years of age missing at least one tooth in the posterior maxilla or mandible were enrolled in the study. Following implant placement, patients received a temporary restoration either on the day of surgery (immediate loading) or 28-34 days after surgery (early loading); restorations consisted of single crowns or two to four unit fixed dental prostheses. Permanent restorations were placed 20-23 weeks following surgery. The primary efficacy variable was change in bone level (assessed by standardized radiographs) from baseline to 5 months; secondary variables included implant survival and success rates. RESULTS: A total of 266 patients were enrolled (118 males and 148 females), and a total of 383 implants were placed (197 and 186 in the immediate and early loading groups, respectively). Mean patient age was 46.3+/-12.8 years. After 5 months, implant survival rates were 98% in the immediate group and 97% in the early group. Mean bone level change from baseline was 0.81+/-0.89 mm in the immediate group and 0.56+/-0.73 mm in the early group (P<0.05). Statistical analysis revealed a significant center effect (P<0.0001) and a significant treatment x center interaction (P=0.008). CONCLUSIONS: The results suggested that Straumann implants with an SLActive can be used predictably in time-critical (early or immediate) loading treatment protocols when appropriate patient selection criteria are observed. The mean bone level changes observed from baseline to 5 months (0.56 and 0.81 mm) corresponded to physiological observations from other studies, i.e., were not clinically significant. The presence of a significant center effect and treatment x center interaction indicated that the differences in bone level changes between the two groups were center dependent.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIMS: (i) To assess the pattern of early bacterial colonization on titanium oral implants after installation, at 12 weeks and at 12 months, (ii) to compare the microbiota at submucosal implant sites and adjacent subgingival tooth sites and (iii) to assess whether or not early colonization was predictive of 12-month colonization patterns. MATERIAL AND METHODS: Submucosal/subgingival plaque samples from 17 titanium oral implants and adjacent teeth were analyzed by checkerboard DNA-DNA hybridization 30 min, 12 weeks and 12 months after implant installation. RESULTS: At 12 months, none of the inserted implants had been lost or presented with signs of peri-implantitis. The distribution of sites at implants and teeth with bleeding on probing varied between 2% and 11%. Probing pocket depths < or =3 mm were found at 75% of implant sites. At 12 months, the sum of the bacterial counts of 40 species was statistically significantly higher at tooth compared with implant sites (mean difference: 34.4 x 10(5), 95% confidence interval -0.4 to 69.4, P<0.05). At 12 months, higher individual bacterial counts at tooth sites were found for 7/40 species compared with implant sites. Detection or lack of detection of Staphylococcus aureus at implant sites at 12 weeks resulted in the highest positive (e.g. 80%) and negative (e.g. 90%) predictive values, respectively. Between 12 weeks and 12 months, the prevalence of Tannerella forsythia increased statistically significantly at implant sites (P<0.05). Lack of detection of Porphyromonas gingivalis at 12 weeks yielded a negative predictive value of 93.1% of this microorganism being undetectable at implant sites at 12 months. CONCLUSIONS: Within the limits of this study, the findings showed (i) a few differences in the prevalence of bacterial species between implant and adjacent tooth sites at 12 months and (ii) high positive and negative predictive values for selected bacterial species.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIM: To evaluate the healing outcome of soft tissue dehiscence coverage at implant sites. MATERIAL AND METHODS: Ten patients with one mucosal recession defect at an implant site and a contralateral unrestored clinical crown without recession were recruited. The soft tissue recessions were surgically covered using a coronally advanced flap in combination with a free connective tissue graft. Healing was studied at 1, 3 and 6 months post-operatively. RESULTS: Soft tissue dehiscences were covered with a coronal overcompensation of the flap margin up to 1.2 mm after the procedure. After 1 month, the coverage shrank to a mean of 75%, after 3 months to 70% and after 6 months to 66%. CONCLUSIONS: The implant sites revealed a substantial, clinically significant improvement following coronal mucosal displacement in combination with connective tissue grafting, but in none of the sites, a could complete implant soft tissue dehiscence coverage be achieved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIMS: To assess the impact of different implant systems on the clinical conditions and the microbiota at implants, and whether the presence of bacteria at tooth sites was predictive of the presence at implant sites. MATERIALS AND METHODS: Subjects with either AstraTech or Brånemark in function for 7 years were enrolled. Sub-gingival bacterial samples at tooth and implant sites were collected with sterile endodontic paper points, and analyzed by the checkerboard DNA-DNA hybridization method (40 species). RESULTS: Fifty-four subjects, 27 supplied with AstraTech (n=132 implants) and 27 with Brånemark (n=102) implants, were studied. Test tooth sites had significantly less evidence of bleeding on probing (P<0.001) and presence of plaque (P<0.001) than implant test sites. Implant sites presented with deeper probing pocket depth than tooth sites (mean difference: 1.1 mm, standard error of differences: 0.08, 95% confidence intervals (CI): 0.9-1.3, P<0.001). Tannerella forsythia (P<0.05), Capnocytophaga sputigena (P<0.05), Actinomyces israelii (P<0.05) and Lactobacillus acidophilus (P<0.05) were found at higher levels at tooth surfaces. No differences in bacterial load for any species were found between the two implant systems. The odds of being present/absent at tooth and implants sites were only significant for Staphylococcus aureus [odds ratio (OR): 5.2 : 1, 95% CI: 1.4-18.9, P<0.01]. CONCLUSIONS: After 7 years in function, implants presented with deeper probing depths than teeth. S. aureus was commonly present at both teeth and implants sites. S. aureus at tooth sites was predictive of also being present at implant sites.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: The aim of the present split-mouth study is to assess the peri-implant conditions around early-loaded sandblasted and acid-etched (SLA) implants, 5 years after abutment connection and to compare, in the same patients, the results obtained with a standard protocol using identical implants with a TPS surface. MATERIAL AND METHODS: Surgical procedure was performed by the same operator and was identical at test (SLA) and control (TPS) sites, in 32 healthy patients. Abutment connection was carried out at 35 N cm 6 weeks postsurgery for test sites and 12 weeks for the controls. Patients were seen regularly, for control and professional cleaning. At 60 months, clinical measures and radiographic bone changes were recorded by the same operator, blind to the type of surface of the implant, on 27 patients, as five patients were lost to follow-up. RESULTS: A total number of 106 implants were examined. No implant was lost. No significant differences were found with respect to the presence of plaque [modified plaque index (mPI) 0.27+/-0.56 vs. 0.32+/-0.54], bleeding on probing (29% vs. 32%), mean pocket depth (3.2+/-1 vs. 3.2+/-1 mm) or mean marginal bone loss (0.32+/-1.04 vs. 0.44+/-1.12 mm) between test and control. Four implants that presented 'spinning' at the time of abutment connection presented no significant differences from the rest of the test sites. CONCLUSION: The results of this prospective study confirm that SLA implants, under defined conditions, are suitable for early loading at 6 weeks in both the mandible and the maxilla. Limited implant spinning, occasionally found at abutment connection, produces no detrimental effect on the clinical outcome when properly handled.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Various imaging techniques, including conventional radiography and computed tomography, are proposed to localize the mandibular canal prior to implant surgery. The aim of this study is to determine the incidence of altered mental nerve sensation after implant placement in the posterior segment of the mandible when a panoramic radiograph is the only preoperative imaging technique used. MATERIAL AND METHODS: The study included 1527 partially and totally edentulous patients who had consecutively received 2584 implants in the posterior segment of the mandible. Preoperative bone height was evaluated from the top of the alveolar crest to the superior border of the mandibular canal on a standard panoramic radiograph. A graduated implant scale from the implant manufacturer was used and 2 mm were subtracted as a safety margin to determine the length of the implant to be inserted. RESULTS: No permanent sensory disturbances of the inferior alveolar nerve were observed. There were two cases of postoperative paresthesia, representing 2/2584 (0.08%) of implants inserted in the posterior segment of the mandible or 2/1527 (0.13%) of patients. These sensory disturbances were minor, lasted for 3 and 6 weeks and resolved spontaneously. CONCLUSIONS: Panoramic examination can be considered a safe preoperative evaluation procedure for routine posterior mandibular implant placement. Panoramic radiography is a quick, simple, low-cost and low-dose presurgical diagnostic tool. When a safety margin of at least 2 mm above the mandibular canal is respected, panoramic radiography appears to be sufficient to evaluate available bone height prior to insertion of posterior mandibular implants; cross-sectional imaging techniques may not be necessary.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: To assess retrospectively, over at least 5 years, the incidences of technical and biological complications and failures in young adult patients with birth defects affecting the formation of teeth. MATERIAL AND METHODS: All insurance cases with a birth defect that had crowns and fixed dental prostheses (FDPs) inserted more than 5 years ago were contacted and asked to participate in a reexamination. RESULTS: The median age of the patients was 19.3 years (range 16.6-24.7 years) when prosthetic treatment was initiated. Over the median observation period of 15.7 years (range 7.4-24.9 years) and considering the treatment needs at the reexamination, 19 out of 33 patients (58%) with reconstructions on teeth remained free from all failures or complications. From the patients with FDPs and single unit crowns (SCs) on implants followed over a median observation period of 8 years (range 4.6-15.3 years), eight out of 17% or 47% needed a retreatment or repair at some point due to a failure or a complication. From the three groups of patients, the cases with amelogenesis/dentinogenesis imperfecta demonstrated the highest failure and complication rates. In the cases with cleft lip, alveolus and palate (CLAP) or hypodontia/oligodontia, 71% of the SCs and 73% of the FDPs on teeth (FDP T) remained complication free over a median observation period of about 16 years. Sixty-two percent of the SCs and 64% of the FDPs on implants remained complication free over 8 years. Complications occurred earlier with implant-supported reconstructions. CONCLUSIONS: Because healthy, pristine teeth can be left unprepared, implant-supported SCs and FDPs are the treatment choice in young adults with birth defects resulting in tooth agenesis and in whom the edentulous spaces cannot be closed by means of orthodontic therapy. However, the trend for earlier and more frequent complications with implant-supported reconstructions in young adults, expecting many years of function with the reconstructions, has to be weighed against the benefits of keeping teeth unprepared. In cases with CLAP in which anatomical conditions render implant placement difficult and in which teeth adjacent to the cleft require esthetic corrections, the conventional FDP T still remains the treatment of choice.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In modern implant dentistry there are several clinical indications for laser surgery. Different laser systems have a considerable spectrum of application in soft and hard peri-implant tissues. The literature was searched for clinical application of different laser wavelengths in peri-implant tissues: second-stage surgery of submerged implants, treatment of infrabony defects, removal of peri-implant hyperplastic overgrowths, and, possibly, the preparation of bone cavities for implant placement. This report describes the state-of-the-art application of different laser systems in modern implant dentistry for the treatment of peri-implant lesions and decontamination of implant surfaces. Our study evaluated in vitro examinations, clinical experience and long-term clinical studies. The exact selection of the appropriate laser system and wavelength was dependent on the scientific evaluation of recent literature and the level of changes in implant and tissue temperatures during laser application. The significant reduction in bacteria on the implant surface and the peri-implant tissues during irradiation and the cutting effects associated with the coagulation properties of the lasers are the main reasons for laser application in the treatment of peri-implant lesions and the successful long-term prognosis of failing oral implants. The various applications of lasers in implant dentistry are dependent on the wavelength and laser-tissue interactions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIM: To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. MATERIAL AND METHODS: For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. RESULTS: All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. CONCLUSIONS: The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES Abstracts of systematic reviews are of critical importance, as consumers of research often do not access the full text. This study aimed to assess the reporting quality of systematic review (SR) abstracts in leading oral implantology journals. METHODS Six specialty journals were screened for SRs between 2008 and 2012. A 16-item checklist, based on the PRISMA statement, was used to examine the completeness of abstract reporting. RESULTS Ninety-three SR abstracts were included in this study. The majority were published in Clinical Oral Implants Research (43%). The mean overall reporting quality score was 72.5% (95% CI: 70.8-74.2). Most abstracts were structured (97.9%), adequately reporting objectives (97.9%) and conclusions (93.6%). Conversely, inadequate reporting of methods of the study, background (79.6%), appraisal (65.6%), and data synthesis (65.6%) were observed. Registration of reviews was not reported in any of the included abstracts. Multivariate analysis revealed no difference in reporting quality with respect to continent, number of authors, or meta-analysis conduct. CONCLUSIONS The results of this study suggest that the reporting quality of systematic review abstracts in implantology journals requires further improvement. CLINICAL SIGNIFICANCE Better reporting of SR abstracts is particularly important in ensuring the reliability of research findings, ultimately promoting the practice of evidence-based dentistry. Optimal reporting of SR abstracts should be encouraged, preferably by endorsing the PRISMA for abstracts guidelines.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE Crohn's disease is a chronic inflammatory process that has recently been associated with a higher risk of early implant failure. Herein we provide information on the impact of colitis on peri-implant bone formation using preclinical models of chemically induced colitis. METHODS Colitis was induced by intrarectal instillation of 2,4,6-trinitro-benzene-sulfonic-acid (TNBS). Colitis was also induced by feeding rats dextran-sodium-sulfate (DSS) in drinking water. One week after disease induction, titanium miniscrews were inserted into the tibia. Four weeks after implantation, peri-implant bone volume per tissue volume (BV/TV) and bone-to-implant contacts (BIC) were determined by histomorphometric analysis. RESULTS Cortical histomorphometric parameters were similar in the control (n = 10), DSS (n = 10) and TNBS (n = 8) groups. Cortical BV/TV was 92.2 ± 3.7%, 92.0 ± 3.0% and 92.6 ± 2.7%. Cortical BIC was 81.3 ± 8.8%, 83.2 ± 8.4% and 84.0 ± 7.0%, respectively. No significant differences were observed when comparing the medullary BV/TV and BIC (19.5 ± 6.4%, 16.2 ± 5.6% and 15.4 ± 9.0%) and (48.8 ± 12.9%, 49.2 ± 6.2 and 41.9 ± 11.7%), respectively. Successful induction of colitis was confirmed by loss of body weight and colon morphology. CONCLUSIONS The results suggest bone regeneration around implants is not impaired in chemically induced colitis models. Considering that Crohn's disease can affect any part of the gastrointestinal tract including the mouth, our model only partially reflects the clinical situation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIM Abstracts of randomized clinical trials are extremely important as trial appraisal is often based on the information included here. The objective of this study was to assess the quality of the reporting of RCT abstracts in journals of Oral Implantology. MATERIAL AND METHODS Six leading Implantology journals were screened for RCTs between years 2008 and 2012. A 21-item modified CONSORT for abstracts checklist was used to examine the completeness of abstract reporting. Descriptive statistics and linear regression modeling were employed for data analysis. RESULTS One hundred and sixty three RCT abstracts were included in this study. The majority of the RCTs were published in the Clinical Oral Implants Research (42.9%). The mean overall reporting quality score was 58.6% (95% CI: 57.6-59.7). The highest score was noted in the European Journal of Oral Implantology (63.8%; 95% CI: 61.8-65.8). Multivariate analysis demonstrated that abstract quality score was related to publication journal and number of research centers involved. Most abstracts adequately reported interventions (89.0%), objectives (77.9%) and conclusions (74.8%) while failed to report randomization procedures, allocation concealment, effect estimate, confidence intervals, and funding. Registration of RCTs was not reported in any of the abstracts. CONCLUSIONS The reporting quality in abstracts of RCTs published in Oral Implantology journals needs to be improved. Editors and authors should be encouraged to endorse the CONSORT for abstracts guidelines in order to achieve optimal quality in abstract reporting.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIM The aim of this prospective, randomized, controlled multicenter study was to determine the 3-year efficacy and stability of the soft and hard tissues at implants with a different geometry that were placed in fresh extraction sockets. MATERIAL AND METHODS Implants with two different configurations, cylindrical (Group A) or conical/cylindrical (Group B) were installed, and healing abutments were attached. Sixteen weeks after implant placement, subjects returned for a re-entry procedure. Prosthetic restorations were delivered 22 weeks after implant placement. Each subject was placed in a 3-year follow-up program, including examinations at yearly visits including various soft tissue and bone level parameters. RESULTS The percentage of sites that were considered inflamed during the follow-up period was stable and varied between 8.8% and 10.2%. The radiographic examinations documented improved bone levels at the final examination and the mean improvement from baseline (placement of permanent restoration; PR) amounted to 0.17 ± 0.67 mm. More than 70% (54 of 76) of the implants monitored in this study suffered no bone loss during the maintenance period. Moreover, there was an obvious "gain" of interproximal soft tissue volume and at the 3-year examination around 25% of all embrasure gaps were completely filled with "papillae". CONCLUSIONS Both conical/cylindrical and cylindrical implants placed in fresh extraction sockets allowed proper soft and hard tissue healing to occur. At both types of implants, mucosal inflammation was infrequent, marginal bone levels were maintained, and soft tissue volume increased gradually after the placement of the permanent restoration.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible. MATERIAL AND METHODS Twenty-three patients received a total of 48 short implants (5 × 5.5 mm and 5 × 7 mm) and 42 regular implants (4 × 10 mm and 4 × 11.5 mm) in the posterior mandible. Patients who received short implants had <10 mm of bone height measured from the bone crest to the outer wall of the mandibular canal. Resonance frequency analysis (RFA) was performed at time intervals T0 (immediately after implant placement), T1 (after 15 days), T2 (after 30 days), T3 (after 60 days), and T4 (after 90 days). RESULTS The survival rate after 90 days was 87.5% for the short implants and 100% for regular implants (P < 0.05). There was no significant difference between the implants in time intervals T1, T2, T3, and T4. In T0, the RFA values of 5 × 5.5 implants were higher than values of 5 × 7 and 4 × 11.5 implants (P < 0.05). A total of six short implants that were placed in four patients were lost (three of 5 × 5.5 mm and three of 5 × 7 mm). Three lost implants started with high ISQ values, which progressively decreased. The other three lost implants started with a slightly lower ISQ value, which rose and then began to fall. CONCLUSIONS Survival rate of short implants after 90 days was lower than that of regular implants. However, short implants may be considered a reasonable alternative for rehabilitation of severely resorbed mandibles with reduced height, to avoid performing bone reconstruction before implant placement. Patients need to be aware of the reduced survival rate compared with regular implants before implant placement to avoid disappointments.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE The aim of this work was to study the peri-implant soft tissues response, by evaluating both the recession and the papilla indexes, of patients treated with implants with two different configurations. In addition, data were stratified by tooth category, smoking habit and thickness of buccal bone wall. MATERIALS AND METHODS The clinical trial was designed as a prospective, randomized-controlled multicenter study. Adults in need of one or more implants replacing teeth to be removed in the maxilla within the region 15-25 were recruited. Following tooth extraction, the site was randomly allocated to receive either a cylindrical or conical/cylindrical implant. The following parameters were studied: (i) Soft tissue recession (REC) measured by comparing the gingival zenith (GZ) score at baseline (permanent restoration) with that of the yearly follow-up visits over a period of 3 years (V1, V2 and V3). (ii) Interdental Papilla Index (PI): PI measurements were performed at baseline and compared with that of the follow-up visits. In addition, data were stratified by different variables: tooth category: anterior (incisors and canine) and posterior (first and second premolar); smoking habit: patient smoker (habitual or occasional smoker at inclusion) or non-smoker (non-smoker or ex-smoker at inclusion) and thickness of buccal bone wall (TB): TB ≤ 1 mm (thin buccal wall) or TB > 1 mm (thick buccal wall). RESULTS A total of 93 patients were treated with 93 implants. At the surgical re-entry one implant was mobile and then removed; moreover, one patient was lost to follow-up. Ninety-one patients were restored with 91 implant-supported permanent single crowns. After the 3-year follow-up, a mean gain of 0.23 mm of GZ was measured; moreover, 79% and 72% of mesial and distal papillae were classified as >50%/ complete, respectively. From the stratification analysis, not significant differences were found between the mean GZ scores of implants with TB ≤ 1 mm (thin buccal wall) and TB > 1 mm (thick buccal wall), respectively (P < 0.05, Mann-Whitney U-test) at baseline, at V1, V2 and V3 follow-up visits. Also, the other variables did not seem to influence GZ changes over the follow-up period. Moreover, a re-growth of the interproximal mesial and distal papillae was the general trend observed independently from the variables studied. CONCLUSIONS Immediate single implant treatment may be considered a predictable option regarding soft tissue stability over a period of 3 years of follow-up. An overall buccal soft tissue stability was observed during the GZ changes from the baseline to the 3 years of follow-up with a mean GZ reduction of 0.23 mm. A nearly full papillary re-growth can be detectable over a minimum period of 2 years of follow-up for both cylindrical and conical/cylindrical implants. Both the interproximal papilla filling and the midfacial mucosa stability were not influenced by variables such as type of fixture configuration, tooth category, smoke habit, and thickness of buccal bone wall of ≤ 1 mm (thin buccal wall).