881 resultados para micro-epidemic
Resumo:
This paper presents a micro power light energy harvesting system for indoor environments. Light energy is collected by amorphous silicon photovoltaic (a-Si:H PV) cells, processed by a switched capacitor (SC) voltage doubler circuit with maximum power point tracking (MPPT), and finally stored in a large capacitor. The MPPT fractional open circuit voltage (V-OC) technique is implemented by an asynchronous state machine (ASM) that creates and dynamically adjusts the clock frequency of the step-up SC circuit, matching the input impedance of the SC circuit to the maximum power point condition of the PV cells. The ASM has a separate local power supply to make it robust against load variations. In order to reduce the area occupied by the SC circuit, while maintaining an acceptable efficiency value, the SC circuit uses MOSFET capacitors with a charge sharing scheme for the bottom plate parasitic capacitors. The circuit occupies an area of 0.31 mm(2) in a 130 nm CMOS technology. The system was designed in order to work under realistic indoor light intensities. Experimental results show that the proposed system, using PV cells with an area of 14 cm(2), is capable of starting-up from a 0 V condition, with an irradiance of only 0.32 W/m(2). After starting-up, the system requires an irradiance of only 0.18 W/m(2) (18 mu W/cm(2)) to remain operating. The ASM circuit can operate correctly using a local power supply voltage of 453 mV, dissipating only 0.085 mu W. These values are, to the best of the authors' knowledge, the lowest reported in the literature. The maximum efficiency of the SC converter is 70.3 % for an input power of 48 mu W, which is comparable with reported values from circuits operating at similar power levels.
Resumo:
OBJECTIVE To assess the validity of dengue fever reports and how they relate to the definition of case and severity. METHODS Diagnostic test assessment was conducted using cross-sectional sampling from a universe of 13,873 patients treated during the fifth epidemiological period in health institutions from 11 Colombian departments in 2013. The test under analyses was the reporting to the National Public Health Surveillance System, and the reference standard was the review of histories identified by active institutional search. We reviewed all histories of patients diagnosed with dengue fever, as well as a random sample of patients with febrile syndromes. The specificity and sensitivity of reports were estimated for this purpose, considering the inverse of the probability of being selected for weighting. The concordance between reporting and the findings of the active institutional search was calculated using Kappa statistics. RESULTS We included 4,359 febrile patients, and 31.7% were classified as compatible with dengue fever (17 with severe dengue fever; 461 with dengue fever and warning signs; 904 with dengue fever and no warning signs). The global sensitivity of reports was 13.2% (95%CI 10.9;15.4) and specificity was 98.4% (95%CI 97.9;98.9). Sensitivity varied according to severity: 12.1% (95%CI 9.3;14.8) for patients presenting dengue fever with no warning signs; 14.5% (95%CI 10.6;18.4) for those presenting dengue fever with warning signs, and 40.0% (95%CI 9.6;70.4) for those with severe dengue fever. Concordance between reporting and the findings of the active institutional search resulted in a Kappa of 10.1%. CONCLUSIONS Low concordance was observed between reporting and the review of clinical histories, which was associated with the low reporting of dengue fever compatible cases, especially milder cases.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia dos Materiais
Resumo:
This work demonstrates the feasibility of using polymeric micro- and nanofiber-composed films and liquid crystals as electrically switchable scattering light shutters. We present a concept of electro-optic device based on an innovative combination of two mature technologies: optics of nematic liquid crystals and electrospinning of nanofibers. These devices have electric and optical characteristics far superior to other comparable methods. The simulation presented shows results that are highly consistent with those of experiments and that explain the working mechanism of the devices.
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.
Resumo:
ABSTRACT OBJECTIVE To describe the increase in cases of malaria in Mozambique. METHODS Cross-sectional study conducted in 2014, in Mozambique with national weekly epidemiological bulletin data. I analyzed the number of recorded cases in the 2009-2013 period, which led to the creation of an endemic channel using the quartile and C-Sum methods. Monthly incidence rates were calculated for the first half of 2014, making it possible to determine the pattern of endemicity. Months in which the incidence rates exceeded the third quartile or line C-sum were declared as epidemic months. RESULTS The provinces of Nampula, Zambezia, Sofala, and Inhambane accounted for 52.7% of all cases in the first half of 2014. Also during this period, the provinces of Nampula, Sofala and Tete were responsible for 54.9% of the deaths from malaria. The incidence rates of malaria in children, and in all ages, have showed patterns in the epidemic zone. For all ages, the incidence rate has peaked in April (2,573 cases/100,000 inhabitants). CONCLUSIONS The results suggest the occurrence of an epidemic pattern of malaria in the first half of 2014 in Mozambique. It is strategic to have a more accurate surveillance at all levels (central, provincial and district) to target prevention and control interventions in a timely manner.
Resumo:
Nanocrystalline diamond (NCD) coatings offer an excellent alternative for tribological applications, preserving most of the intrinsic mechanical properties of polycrystalline CVD diamond and adding to it an extreme surface smoothness. Silicon nitride (Si3N4) ceramics are reported to guarantee high adhesion levels to CVD microcrystalline diamond coatings, but the NCD adhesion to Si3N4 is not yet well established. Micro-abrasion tests are appropriate for evaluating the abrasive wear resistance of a given surface, but they also provide information on thin film/substrate interfacial resistance, i.e., film adhesion. In this study, a comparison is made between the behaviour of NCD films deposited by hot-filament chemical vapour deposition (HFCVD) and microwave plasma assisted chemical vapour deposition (MPCVD) techniques. Silicon nitride (Si3N4) ceramic discs were selected as substrates. The NCD depositions by HFCVD and MPCVD were carried out using H2–CH4 and H2–CH4–N2 gas mixtures, respectively. An adequate set of growth parameters was chosen for each CVD technique, resulting in NCD films having a final thickness of 5 m. A micro-abrasion tribometer was used, with 3 m diamond grit as the abrasive slurry element. Experiments were carried out at a constant rotational speed (80 r.p.m.) and by varying the applied load in the range of 0.25–0.75 N. The wear rate for MPCVD NCD (3.7±0.8 × 10−5 m3N−1m−1) is compatible with those reported for microcrystalline CVD diamond. The HFCVD films displayed poorer adhesion to the Si3N4 ceramic substrates than the MPCVD ones. However, the HFCVD films show better wear resistance as a result of their higher crystallinity according to the UV Raman data, despite evidencing premature adhesion failure.
Resumo:
Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.
Resumo:
The injection process of glass fibres reinforced plastics promotes the moulds surface degradation by erosion. In order to improve its wear resistance, several kinds of PVD thin hard coatings were used. It is well-known that nanostructures present a better compromise between hardness and toughness. Indeed, when the coating is constituted by a large number of ultra-thin different layers, cracks and interface troubles tend to decrease. However, it is not clear that these nanostructures present a better wear behaviour in erosion processes. In order to study its wear behaviour, a sputtered PVD nanostructured TiAlCrSiN coating was used. The substrate and film surfaces topography were analyzed by profilometry and atomic force microscopy techniques. Film adhesion to the substrate was evaluated by scratch tests. The surface hardness was measured with a Vickers micro-hardness tester. The wear resistance was evaluated by micro-abrasion with a rotating ball tribometer tests. Slurry of SiC particles in distilled water was used in order to provoke the surface abrasion. Different duration tests were performed in order to analyze the wear evolution. After these tests, the wear mechanisms developed were analyzed by scanning electron microscopy. Wear craters were measured and the wear rate was calculated and discussed. With the same purpose, coated inserts were mounted in an injection mould working with a 30% glass fibres reinforced polypropylene. After 45 000 cycles no relevant wear was registered.
Resumo:
The paper presents a study on business micro-location behaviour as well as corresponding factors of influence, conducted in two metropolitan areas, Bucharest-Ilfov (Romania) and Greater Porto (Portugal). By business micro-location we refer to a specific site such as a building or facility, accommodating a business within a small, compact geographical area (e.g. metropolitan area). At this geographical scale, the macroeconomic layer factors were excluded, applicable when discern between regions or countries. The factors derived from location theory and previous empirical studies were surveyed, completing a cross-sectional analysis in order to find out the specific weights of the location factors and preferences, by region and by industry. Based on already established firms’ feedback on location, the specific weights were granted by each industry to the main location factors, types of areas, and types of accommodation facilities. The authors also suggested a model to integrate these results into a Geographical Information System (GIS).
Resumo:
Dissertação apresentada para cumprimento dos requisitos necessários à obtenção do grau de Doutor em Sociologia.
Resumo:
Laboratorial studies were carried out on 3178 patients with signs and symptoms suggestive of dengue infection from April 1986 to December 1987 in the State of Rio de Janeiro, Brazil. The epidemic had two peaks following the first virus isolation and affected the inhabitants of 17 counties. Both sex and all age groups were affected. Dengue virus type 1 was isolated from 1039 sera and the number of confirmed cases was increased to 1874 (59%) by MAC-ELISA. Isolation rate confirmed cases reached 80% in the specimens obtained until the 4th day after the onset of disease and viraemia ranged from 10 3.0 to 10(8.5) TCID50/ml.
Resumo:
Between March and July, 1992, we screened for Vibrio all fecal samples submitted for bacteriologic diagnosis at a private clinical laboratory in Recife. Of 1435 cultures examined only 1 (0.07%) was positive for V.cholerae 01, biovar Eltor, serovar Inaba, but 17 (1.2%) yielded non-cholera Vibrio (V.cholerae non-01; V.fluvialis; V.furnissii, V.parahaemolyticus and Vibrio spp). Thus, V.cholerae 01, differently of other enteropathogenic vibrios, spared individuals of good socioeconomic conditions even during the cholera epidemic, which made hundreds of victims in the neighboring slums.
Resumo:
This research is part of a larger project focused on producing a History of the Popularization of Science and Technology in Portugal. The goal is to find out how scientific knowledge reached the common people in the nineteenth century, using newspapers as the main source of information. Keeping in mind the population’s limited access to written material, nevertheless each newspaper could be read daily by an estimate 30.000 people in Lisbon, which places this source as probably the most widespread vehicle to divulge the latest scientific news at the time to an unspecialised audience. With a cholera morbus epidemic which affected the second largest Portuguese town and all the northern regions, as well as the Algarve, news and reports on its evolution were considered essential. A large database was built in order to analyse the news concerning this disease in 1855 and 1856, especially the ones about prevention and treatment. These are important historical sources that give us real information on the scientific knowledge of the time and the way it was used by society.
Resumo:
An outbreak of dengue 4 occurred in the Yucatán, México in 1984. During the course of the outbreak, 538 of 5486 reported cases of dengue-like illness were studied; 200 were confirmed as dengue serologically and/or virologically. Dengue 4 virus was isolated from 34 patients and dengue 1 from one. Severe haemorrhagic symptoms were observed in 9 laboratory confirmed patients, including four deaths. Thus, the outbreak in Yucatán is the second dengue epidemic in the Americas after the Cuban epidemic in 1981 in which a number of patients suffered from haemorrhagic complications. It was notable that 5 of 9 hospitalized, severe cases were young adults and that only one met the WHO criteria of DHF, in contrast to primary pediatric nature of DHF in Southeast Asia. In this paper we describe clinical, serologic, and virologic studies conducted during the outbreak.